Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sodium Pool Fire Phenomena, Sodium Pool Fire Modeling in SOFIRE II, and SOFIRE II Calculations for the AFR-100

The SOFIRE II computer code for the calculation of sodium pool fires has been obtained from the Reactor Safety Information Computational Center and the SOFIRE II ONE CELL version has been implemented at Argonne National Laboratory (ANL). A critical review of literature relevant to sodium pool fires has been carried out with the objectives of understanding sodium pool fire phenomena and how well specific phenomena are modeled or neglected in SOFIRE II. Significant predictions about sodium pool fires can be made on the basis of first principles analyses alone making use of the existing experiment database and knowledge base. In implementing SOFIRE II ONE CELL, minor modifications were necessary to compile and execute the code on a personal computer (PC) and to verify the results of the test case problem. The code was applied to the AFR-100 Sodium-Cooled Fast Reactor (SFR) design to calculate a sodium pool fire following a postulated failure of the sodium storage vessel of one of the four intermediate sodium heat transport circuits and the subsequent release of sodium onto the floor of the steel-lined compartment in which the sodium storage vessel is located. SOFIRE II calculates that only a small fraction of the released sodium burns due to the rapid consumption of the available oxygen inside of the closed compartment. The preliminary results demonstrate the effects of the heat sinks provided by the compartment floor, walls, and ceiling in reducing the temperature of the sodium pool with time.

Sienicki, James J.↗

Ames T-3 fire test facility - Aircraft crash fire simulation

There is a need to characterize the thermal response of materials exposed to aircraft fuel fires. Large scale open fire tests are costly and pollute the local environment. This paper describes the construction and operation of a subscale fire test that simulates the heat flux levels and thermochemistry of typical open pool fires. It has been termed the Ames T-3 Test and has been used extensively by NASA since 1969 to observe the behavior of materials exposed to JP-4 fuel fires.

Fish, R. H.↗

Analysis of JP-4 fire test data and development of a simple fire model

A series of field experiments involving JP-4 fires of 7.6m dia and 15.2m dia was conducted under the sponsorship of NASA. The temperature inside the fire, the specie composition and vertical axial velocity were measured at several height locations and radial positions. The peak temperature recorded is 1400-1500 K; the velocities at 6m height are 11-12 m/s. The oxygen-to-nitrogen mass ratio along the vertical axis was found to be nearly a constant at 0.05. Significant necking of the fire was observed. A simple theoretical model was developed that predicts the experimental data on the velocity and vertical temperature distribution well. The model is based on the partial combustion of entrained air and assumed top-hat distributions for various property and flow parameters inside the fire. Quantitative agreement is obtained by using a value of 0.15 for the entrainment coefficient and 0.45 for the mixing efficiency factor. The model also predicts the fire necking.

Raj, P. K.↗

NASA's Fire Information for Resource Management System (FIRMS): Near Real-Time Global Fire Monitoring Using Data from MODIS and VIIRS

NASA's Fire Information for Resource Management System (FIRMS) provides near-real time active fire / hotspot products from MODIS and VIIRS to users in over 160 countries. The goal of FIRMS is to meet the needs of natural resource and protected area managers that face considerable challenges in obtaining timely satellite-derived information on fires burning within and around their management area. FIRMS has been reliably providing active fire / hotspot data in easy to use formats since its inception in 2006. Fire information is provided through a web map interface, email alerts, a web mapping service, and a range of downloadable files (SHP, CSV, KML and JSON). FIRMS data are used directly by end users and by brokers who take the data and add value to it before re-distributing it.FIRMS was initially developed by the University of Maryland in 2006; it was funded by the United Nations FAO and NASA's Applied sciences program under a NASA ROSES call. In 2012 FIRMS became integrated in to NASA's Land Atmosphere Near real-time Capability for EOS (LANCE); a virtual system that leverages NASAs existing science processing capabilities to deliver NRT data from ten instruments within 3 hours of satellite overpass. This presentation will describe the FIRMS system, provide an overview of the system, briefly describe some of the known applications and describe plans to further integrate the data in to NASA's Global Imagery Browse Services (GIBS) public mapping services and Worldview website.

active fire/hotspots↗

Simulation of an Industrial Tangentially Fired Boiler Firing Metallurgical Gases

In industrial environments, boiler units are widely used to supply heat and electrical power. At an integrated steel mill, industrial boilers combust a variable mixture of metallurgical gases combined with additional fuels to generate high-pressure superheated steam. Most tangentially fired boilers have experienced water wall tube failures in the combustion zone, which are thought to be caused by some deficiency in the combustion process. The challenge faced in this present process is that there are very limited means to observe the boiler operation. In our study, a three-dimensional computational fluid dynamics (CFD) modeling and simulation of an industrial tangentially fired boiler firing metallurgical gases was conducted. Eddy dissipation combustion model was applied on this multiple fuel combustion process. Simulation results obtained from the developed CFD model were validated by industrial experiments. Furthermore, a quick comparison of the flame shape from the simulation to the actual flame in the boiler showed a good agreement. We also analyzed the flow field and temperature distribution inside the tangentially fired boiler under the operation conditions, and a wall water tube overheating problem was observed and directly related to the flow

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparison of Geospatially Modeled Fire Behavior and Potential Application to Fire and Fuels Management for the Savannah River Site

This study evaluates modeled fire behavior for the Savannah River Site in the Atlantic Coastal Plain of the southeastern U.S. using three data sources: FCCS, LANDFIRE, and SWRA. The Fuel Characteristic Classification System (FCCS) was used to build fuelbeds from intensive field sampling of 629 plots. Custom fire behavior fuel models were derived from these fuelbeds. LANDFIRE developed surface fire behavior fuel models and canopy attributes for the U.S. using satellite imagery informed by field data. The Southern Wildfire Risk Assessment (SWRA) developed surface fire behavior fuel models and canopy cover for the southeastern U.S. using satellite imagery.

60 APPLIED LIFE SCIENCES↗

Fire compartment partitioning approaches for fire probabilistic safety analysis of a high-temperature gas-cooled reactor - 18545

Fire compartment partitioning is the foundational task in Fire Probabilistic Safety Analysis (FPSA), that requires approaches able to balance analytical accuracy and computational burden. In this work, two fire compartment partitioning approaches are illustrated and applied to an electric building of a High-Temperature Gas-Cooled Reactor (HTGR, e.g., HTR-PM), and the quantified risks of the compartments obtained with the two approaches are compared. The results show that risk is insensitive to the utilized fire compartment partitioning approach, making the FPSA tasks easier to be performed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rare earth minerals in a "no tonstein" section of the Dean (Fire Clay) coal, Knox County, Kentucky

The Dean (Fire Clay) coal in Knox County, Kentucky, does not contain the megascopically-visible ash-fall tonstein present in most other sections of the coal bed. Like the Fire Clay tonstein, a low-ash portion of the coal is enriched in rare earth elements (>2400ppm, on ash basis). In addition to kaolinite produced in the diagenesis of volcanic glass, transmission electron microscopy studies indicate the coal contains primary kaolinite, La Ce Nd Th monazite, barium niobate, native gold, and Fe Ni Cr spinels. The mineral assemblages, particularly the kaolinite-monazite association and its similarity to the tonsteins in coal to the east, demonstrate the coal was subject to the REE-enriched volcanic ash fall, apparently just at a more dilute level than at locations where the tonstein is present.

coal, rare earth, tonstein↗

Metal toxin threat in wildland fires determined by geology and fire severity

Accentuated by climate change, catastrophic wildfires are a growing, distributed global public health risk from inhalation of smoke and dust. Underrecognized, however, are the health threats arising from fire-altered toxic metals natural to soils and plants. Here, we demonstrate that high temperatures during California wildfires catalyzed widespread transformation of chromium to its carcinogenic form in soil and ash, as hexavalent chromium, particularly in areas with metal-rich geologies (e.g., serpentinite). In wildfire ash, we observed dangerous levels (327-13,100 µg kg -1 ) of reactive hexavalent chromium in wind-dispersible particulates. Relatively dry post-fire weather contributed to the persistence of elevated hexavalent chromium in surficial soil layers for up to ten months post-fire. The geographic distribution of metal-rich soils and fire incidents illustrate the broad global threat of wildfire smoke- and dust-born metals to populations. Our findings provide new insights into why wildfire smoke exposure appears to be more hazardous to humans than pollution from other sources.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evidence for an unorthodox firing sequence employed by the Berlin Painter. Deciphering ancient ceramic firing conditions through high-resolution material characterization and replication

XANES spectroscopy was used to complement the results previously obtained with Raman spectroscopy by the same group to determine the firing conditions used in the production of a single vessel painted by the Berlin Painter in the 5th century B.C. The vessel, part of the collection of the J. Paul Getty Museum, presents a complicated layered architecture of black and red gloss, with different stratigraphies present on the interior and exterior surfaces. The study of two samples, one each from the interior and exterior surface of the vessel, was performed with the complementary analytical techniques of X-ray nano- and micro-spectroscopy (X-ray fluorescence spectroscopy (XRF) and full-field transmission X-ray micro-spectroscopy (FF-XANES) across the Fe K edge), and supported by a replication study. The replicates, made in a laboratory furnace providing complete control over the firing temperature and oxygen partial pressure, provided a paradigm for the comparison of the mineralogical phases observed in the ancient samples, which led to a deeper understanding of the firing conditions necessary for the production of the Berlin Painter's vessel. Our results confirm the necessity of multiple firings and painting applications to obtain the Berlin Painter's architecture and provide a further example of the multiplicity of techniques and practices employed by the potters of the Kerameikos in ancient Athens.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature and heat flux datasets of a complex object in a fire plume for the validation of fire and thermal response codes.

It is necessary to improve understanding and develop temporally- and spatially-resolved integral scale validation data of the heat flux incident to a complex object in addition to measuring the thermal response of said object located within the fire plume for the validation of the SIERRA/FUEGO/SYRINX fire and SIERRA/CALORE codes. To meet this objective, a complex calorimeter with sufficient instrumentation to allow validation of the coupling between FUEGO/SYRINX/CALORE has been designed, fabricated, and tested in the Fire Laboratory for Accreditation of Models and Experiments (FLAME) facility. Validation experiments are specifically designed for direct comparison with the computational predictions. Making meaningful comparison between the computational and experimental results requires careful characterization and control of the experimental features or parameters used as inputs into the computational model. Validation experiments must be designed to capture the essential physical phenomena, including all relevant initial and boundary conditions. This report presents the data validation steps and processes, the results of the penlight radiant heat experiments (for the purpose of validating the CALORE heat transfer modeling of the complex calorimeter), and the results of the fire tests in FLAME.

99 GENERAL AND MISCELLANEOUS↗

Analysis of NASA JP-4 fire tests data and development of a simple fire model

The temperature, velocity and species concentration data obtained during the NASA fire tests (3m, 7.5m and 15m diameter JP-4 fires) were analyzed. Utilizing the data analysis, a sample theoretical model was formulated to predict the temperature and velocity profiles in JP-4 fires. The theoretical model, which does not take into account the detailed chemistry of combustion, is capable of predicting the extent of necking of the fire near its base.

Raj, P.↗

The Elimination of Fire Hazard Due to Back Fires

A critical study was made of the operation of a type of back-fire arrester used to reduce the fire hazard of aircraft engines. A flame arrester consisting of a pack or plug of alternate flat and corrugated plates of thin metal was installed in the intake pipe of a gasoline engines; an auxiliary spark plug inserted in the intake manifold permitted the production of artificial back fires at will. It was found possible to design a plug which prevented all back fires from reaching the carburetor.

Theodorsen, Theodore↗

MODIS airborne simulator visible and near-infrared calibration, 1991 FIRE-Cirrus field experiment. Calibration version: FIRE King 1.1

Calibration of the visible and near-infrared channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1991 FIRE-Cirrus field experiment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Laboratory tests during the FIRE Cirrus field experiment were conducted to calibrate the hemisphere and from the hemisphere to the MAS. The purpose of this report is to summarize the FIRE-Cirrus hemisphere calibration, and then describe how the MAS was calibrated from observations of the hemisphere data. All MAS calibration measurements are presented, and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. Thermal sensitivity of the MAS visible and near-infrared calibration is also discussed. Typically, the MAS in-flight is 30 to 60 degrees C colder than the room temperature laboratory calibration. Results from in-flight temperature measurements and tests of the MAS in a cold chamber are given, and from these, equations are derived to adjust the MAS in-flight data to what the value would be at laboratory conditions. For FIRE-Cirrus data, only channels 3 through 6 were found to be temperature sensitive. The final section of this report describes comparisons to an independent MAS (room temperature) calibration by Ames personnel using their 30-inch integrating sphere.

Arnold, G. Thomas↗

Comparative Analysis of Daytime Fire Detection Algorithms, Using AVHRR Data for the 1995 Fire Season in Canda: Perspective for MODIS

Two fixed-threshold Canada Centre for Remote Sensing and European Space Agency (CCRS and ESA) and three contextual GIGLIO, International Geosphere and Biosphere Project, and Moderate Resolution Imaging Spectroradiometer (GIGLIO, IGBP, and MODIS) algorithms were used for fire detection with Advanced Very High Resolution Radiometer (AVHRR) data acquired over Canada during the 1995 fire season. The CCRS algorithm was developed for the boreal ecosystem, while the other four are for global application. The MODIS algorithm, although developed specifically for use with the MODIS sensor data, was applied to AVHRR in this study for comparative purposes. Fire detection accuracy assessment for the algorithms was based on comparisons with available 1995 burned area ground survey maps covering five Canadian provinces. Overall accuracy estimations in terms of omission (CCRS=46%, ESA=81%, GIGLIO=75%, IGBP=51%, MODIS=81%) and commission (CCRS=0.35%, ESA=0.08%, GIGLIO=0.56%, IGBP=0.75%, MODIS=0.08%) errors over forested areas revealed large differences in performance between the algorithms, with no relevance to type (fixed-threshold or contextual). CCRS performed best in detecting real forest fires, with the least omission error, while ESA and MODIS produced the highest omission error, probably because of their relatively high threshold values designed for global application. The commission error values appear small because the area of pixels falsely identified by each algorithm was expressed as a ratio of the vast unburned forest area. More detailed study shows that most commission errors in all the algorithms were incurred in nonforest agricultural areas, especially on days with very high surface temperatures. The advantage of the high thresholds in ESA and MODIS was that they incurred the least commission errors.

Ichoku, Charles↗

Fire Analysis of the Thomas Fire in California Using NASA Data in a GIS

These maps are an analysis of the Thomas Fire that occurred in California during December 2017. Using a variety of NASA Earth science data from five National Aeronautics and Space Administration (NASA) sources (including four Earth Observing System Data and Information System Distributed Active Archive Centers and NASA Fire Information for Resource Management System), as well as ancillary data from Ventura County, Santa Barbara County, and the Department of Homeland Security, this analysis sought to identify forest fire risk zones, create a fire occurrence density map, examine the vegetation and subsequent burn scar, capture the affected parcels, and capture the affected vegetation.

Bagwell, Ross↗