At least 91 records · Page 5

BayoTech Risk and Modeling Support

This white paper describes the work performed by Sandia National Laboratories in the New Mexico Small Business Agreement with BayoTech. BayoTech is a hydrogen generation and distribution company that is located in Albuquerque, NM. Their goal is to distribute hydrogen via their hydrogen systems which utilize the core design that was developed by Sandia. However, because the hydrogen economy is in its nascency, the safety and operation of the generating systems require independent validation. Additionally, in their pursuit of permitting at various locations around the nation, they require fire protection engineering support in discussions with local fire marshals and neighboring industrial entities. Sandia National Laboratories has subject matter expertise in hydrogen risk modeling of consequence (overpressure and dispersion) as well as fire protection engineering. Throughout this project, Sandia has worked with BayoTech to provide our expertise in these subject areas to facilitate the market entry of their hydrogen generation project to address the dire need for decarbonization due to climate change. The general approach of the support by Sandia is outlined in the main body, while the location specific evaluation for the Port of Stockton is contained in Appendix A.

08 HYDROGEN↗

Alternative approach for fire suppression of class A, B and C fires in gloveboxes

Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, is capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.

99 GENERAL AND MISCELLANEOUS↗

Research Needs in Fire Safety for the Human Exploration and Utilization of Space: Proceedings and Research Plan

The purpose of the workshop documented in this publication was to bring together personnel responsible for the design and operations of the International Space Station (ISS) and the fire protection research community to review the current knowledge in fire safety relative to spacecraft. From this review, research needs were identified that were then used to formulate a research plan with specific objectives. In this document, I have attempted to capture the very informative and lively discussions that occurred in the plenary sessions and the working groups. I hope that it will be useful to readers and serve as a significant step in assuring fire protection for the crews of current and future spacecraft.

Ruff, Gary A.↗

Safety Related Concerns with Installation and Use of Switch-Rated Plug/Receptacle Combinations in Lieu of Metal-Enclosed Disconnect Switches

The manufacturers of Nationally Recognized Testing Laboratory (NRTL) listed, switch-rated, plug and receptacle combinations tout their convenience, reliability, efficiency, and compliance with both the National Fire Protection Association (NFPA) 70®, National Electric Code (NEC), and National Fire Protection Association 70E®, The Standard for Electrical Safety in the Workplace, as advantages to using these products in lieu of traditional metal-enclosed disconnect switches. The purpose of this paper is to raise awareness of several unintended consequences that can result when replacement involves high energy cord and plug connected equipment. This paper describes several possible issues in complying with the NFPA 70 Articles 110 and 400 and NFPA 70E Articles 110 and 130 that should be considered when using load rated plug/receptacle combinations. This paper is intended to address high energy circuits typically associated with 480 volt pin and sleeve type connections in applications where incident energy levels may exceed 1.2 calories/centimeter² (cal/cm²).

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

Thermochemical characterization of intumescent materials and their application in FEM models using Aria

Intumescent materials are in wide use as protective coatings in fire protection or thermal management applications. These materials undergo chemical reactions occurring from approximately 300°C to 900°C, which outgas and expand the material, providing an appreciable increase in insulative performance. However, the complicated chemical mechanisms and large changes in materials properties complicate the incorporation of these materials into predictive thermal models. This document serves to outline the thermochemical characterization of select intumescent materials, the extraction of relevant parameters, and the incorporation of these parameters into the ChemEQ reaction model implemented in Aria. This work was performed in 2016 and documented in a draft SAND report in March 2017. In 2022, the draft SAND report was discovered and put through R&A.

36 MATERIALS SCIENCE↗

Convective Melting of Particles in Flow Under Microgravity Conditions

Study of melting of dispersed or packed solid particles in a fluid under gravity and microgravity conditions provides benchmark information for many engineering applications such as material processing, environmental assessment and protection and space fire protection. During such processes, packed or dispersed solid particles are interacting with fluid flow at above-melting temperatures. By unmasking the buoyancy effects in coupled flow, phase change and heat transport phenomena, a better understanding of melting rate in non-thermal equilibrium, convective conditions can be studied. A series of flight experiments were conducted onboard the NASA KC-135 Microgravity Research Airplane. The Particle Melting in Plow (PMF) module was designed to allow flow through the initially packed ice particles at controlled temperature and velocity. To achieve this, a close-loop flow system was designed. Video images were taken to record the visualization of the melting process, from which a time variation of packed particle thickness distribution at different times can be obtained by the image analysis method. The fluid temperature distribution within the melting zone is measured by thermocouples. An infrared camera was mounted from the top of the test section to record the ice-water thermal images at a given location. The results from thermal images yield local temperature variation between melting solid and liquid and local Stephan number. Typical results for a number of cases are presented. The mathematical model, describing mass, energy, and momentum balance equations for the liquid and solid phases, is presented. It is found that melting rate is influenced mainly by the ratio of Reynolds number (based on the initial particle diameter) to the Froud number, and Stephan number. At the absence of gravity, Froud number approaches zero, Reynolds number and Stephan number become dominant factors governing the melting rate. The numerically determined results are compared with the experimental ones. It is found that the discrepancy between the predicted and measured melting rate is largely due to the inaccuracy in the constitutive equations for effective thermal physical properties, such as effective thermal conductivity and diffusivity, and transport properties, such as particle interaction coefficient, and local heat transfer coefficient of particles.

Stewart, C.↗

Phase II Testing of Liquid Cooling Garments Using a Sweating Manikin, Controlled by a Human Physiological Model

An Advanced Automotive Manikin (ADAM) developed at the National Renewable Energy Laboratory (NREL) is used to evaluate NASA's liquid cooling garments (LCGs) used in advanced space suits for extravehicular applications. The manikin has 120 separate heated/sweating zones and is controlled by a finite element physiological model of the human thermoregulatory system. Previous testing showed the thermal sensation and comfort followed the expected trends as the LCG inlet fluid temperature was changed. The Phase II test data demonstrates the repeatability of ADAM by retesting the baseline LCG. Skin and core temperature predictions using ADAM in an LCG/Arctic suit combination are compared to NASA physiological data to validate the manikin/model. Additional LCG configurations are assessed using the manikin and compared to the baseline LCG. Results can extend to other personal protective clothing, including HAZMAT suits, nuclear/biological/chemical protective suits, and fire protection suits.

Paul, Heather↗

High-Volume Airborne Fluids Handling Technologies to Fight Wildfires

NASA recently partnered with the U.S. Forest Service (USFS) on a project to examine mission suitability and recommend policies and procedures for the use of very large aerial firefighting aircraft such as the Boeing 747 and DC-10 aerial retardant delivery aircraft. The aircraft under study included a 10Tanker DC-10 and an Evergreen B-747. NASA's Dryden Flight Research Center and Ames Research Center worked with the USFS to help determine the safe flight envelope for these Very Large Air Tanker (VLAT) aircraft for the USFS and the Department of the Interior (DOI). This new generation of supertankers includes aircraft like these that have as much as four times the delivery capacity of the previous generation of aerial firefighting aircraft. Dryden performed operational test and evaluation assessments and reported findings and recommendations on these aircraft in cooperation with Ames. The team developed, implemented, and directed an evaluation test plan for use in flight test and in simulation. Ames provided support using pilot-in-the-loop simulations and coordinated simulator models, flight profiles, and data analysis with Dryden. The test plan was designed to evaluate the suitability of VLAT aircraft as a function of mission environment. Based on this analysis, NASA generated interim flight envelope limitations to enhance safety and operational utility in the fire-retardant delivery mission. These recommended flight limitations were adopted by the USFS. The 10Tanker DC-10 has been in use for several years with the California Department of Forestry and Fire Protection(Cal-Fire), but until NASA took on the challenge of reviewing VLAT capabilities and limitations, the USFS was hesitant to add them to the federal wildfire arsenal. The DC-10 delivery system is based on an externally mounted set of tanks and a bomb-bay style set of clamshell doors that are opened in precisely calibrated ways to deliver the amounts and concentrations of retardant called for by the specific wildfire situation. The system was manufactured by Jordan Air of Central Point, OR, and was installed by Victorville Aerospace in Victorville, CA. It can deliver 12,000 gallons (45.4 kL) of retardant in as little as eight seconds. The aircraft can deliver a partial load of retardant and make multiple drops on the same flight, or the entire load can be rapidly delivered in one pass if required for maximum coverage. The Evergreen 747 uses internal tankage and a pressurized delivery system to enable volume and coverage levels that also meet USFS requirements, but enables computer control of flow for desired precision. This system was designed and built by Adaptive Aerospace of Tehachapi, CA and can deliver about 20,000 gallons (75.7 kL) of retardant in approximately ten seconds. The 747 can also make multiple independent drops, or deliver the entire load at once. NASA found that both of these VLAT aircraft are compatible with the wildfire suppression mission when used to supplement other aerial retardant delivery platforms. The major recommendations for deployment that resulted from this study relate to terrain clearance, the type of terrain in the drop area, availability of qualified lead planes to guide the VLAT approach to the drop area, and low-altitude maneuvering limitations. NASA s analysis suggests that with the appropriate flight procedures, these aircraft will provide a powerful set of tools to fight wildfires.

Dickerson, Mark↗

Optimization of aircraft seat cushion fire blocking layers

This report describes work completed by the National Aeronautics and Space Administration - for the Federal Aviation Administration Technical Center. The purpose of this work was to examine the potential of fire blocking mechanisms for aircraft seat cushions in order to provide an optimized seat configuration with adequate fire protection and minimum weight. Aluminized thermally stable fabrics were found to provide adequate fire protection when used in conjunction with urethane foams, while maintaining minimum weight and cost penalty.

Kourtides, D. A.↗

Fire safety practices in the Shuttle and the Space Station Freedom

The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

Friedman, Robert↗

Convergent spray process for environmentally friendly coatings

Conventional spray application processes have poor transfer efficiencies, resulting in an exorbitant loss in materials, solvents, and time. Also, with ever tightening Environmental Protection Agency (EPA) regulations and Occupational Safety and Health Administration requirements, the low transfer efficiencies have a significant impact on the quantities of materials and solvents that are released into the environment. High solids spray processes are also limited by material viscosities, thus requiring many passes over the surface to achieve a thickness in the 0.125 -inch range. This results in high application costs and a negative impact on the environment. Until recently, requirements for a 100 percent solid sprayable, environmentally friendly, lightweight thermal protection system that can be applied in a thick (greater than 0.125 inch) single-pass operation exceeded the capability of existing systems. Such coatings must be applied by hand lay-up techniques, especially for thermal and/or fire protection systems. The current formulation of these coatings has presented many problems such as worker safety, environmental hazards, waste, high cost, and application constraints. A system which can apply coatings without using hazardous materials would alleviate many of these problems. Potential applications include the aerospace thermal protective specialty coatings, chemical and petroleum industries that require fire-protection coatings that resist impact, chemicals, and weather. These markets can be penetrated by offering customized coatings applied by automated processes that are environmentally friendly.

Scarpa, Jack↗

Antimisting kerosene: Base fuel effects, blending and quality control techniques

The problems associated with blending of the AMK additive with Jet A, and the base fuel effects on AMK properties are addressed. The results from the evaluation of some of the quality control techniques for AMK are presented. The principal conclusions of this investigation are: significant compositional differences for base fuel (Jet A) within the ASTM specification DI655; higher aromatic content of the base fuel was found to be beneficial for the polymer dissolution at ambient (20 C) temperature; using static mixer technology, the antimisting additive (FM-9) is in-line blended with Jet A, producing AMK which has adequate fire-protection properties 15 to 20 minutes after blending; degradability of freshly blended and equilibrated AMK indicated that maximum degradability is reached after adequate fire protection is obtained; the results of AMK degradability as measured by filter ratio, confirmed previous RAE data that power requirements to decade freshly blended AMK are significantly higher than equilibrated AMK; blending of the additive by using FM-9 concentrate in Jet A produces equilibrated AMK almost instantly; nephelometry offers a simple continuous monitoring capability and is used as a real time quality control device for AMK; and trajectory (jet thurst) and pressure drop tests are useful laboratory techniques for evaluating AMK quality.

Yavrouian, A. H.↗

Emergency Response Capability Baseline Needs Assessment - Compliance Assessment

This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016 BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.

99 GENERAL AND MISCELLANEOUS↗

Effects of Irradiation on Thermal Properties of Polyurethane Foam

Polyurethane foam is used as a thermal insulator, fire protective material, and impact absorber in the 9977 shipping package. The 9977 shipping package is used to transport special nuclear materials (SNM), and store SNM in the K-area complex at the Savannah River Site. The primary fire-retardant mechanism in the foam is that it produces intumescent char when exposed to high temperatures. Intumescence occurs in the direction of heat application and can allow the foam to “repair” cracks in the event of a mechanical impact, in addition to serving as a secondary thermal barrier with decreased heat conductivity. Because the foam is being used for long-term storage applications, it is vital that it retain its physical, thermal, and mechanical properties over the course of time and with the events of exposure of heat and irradiation. The goal of this project was to determine the effects of gamma irradiation on the thermal properties of polyurethane foam, both in terms of cumulative irradiation and rate of irradiation. At the dose rates and cumulative doses of irradiation measured, there was no correlation between higher cumulative irradiation and thermal stability, specific heat capacity, or chemical structure. Based on the results of the experiments, the fire protective properties in the 9977 shipping containers should be retained with the expected amount of radiation exposure.

36 MATERIALS SCIENCE↗

NASA Issues Related to use of Halon: Past, Present, Future

NASA began an official halon phaseout program in 1990. NASA has led the way in halon bank management and has participated in the search for halon alternatives. NASA representatives participate in technical committees of the National Fire Protection Association and United Nations Environment Program providing guidance on Halon Phaseout and acceptance, design, installation, and maintenance of Halon Alternatives. This paper addresses some of the key issues that are leading the agency away from dependence on halons for fire protection.

Collins, Michelle M.↗

Life Support and Habitation Systems: Crew Support and Protection for Human Exploration Missions Beyond Low Earth Orbit

Life Support and Habitation Systems (LSHS) is one of 10 Foundational Domains as part of the National Aeronautics and Space Administration s proposed Enabling Technology Development and Demonstration (ETDD) Program. LSHS will develop and mature technologies to sustain life on long duration human missions beyond Low Earth Orbit that are reliable, have minimal logistics supply and increase self-sufficiency. For long duration exploration missions, further closure of life support systems is paramount, including focus on key technologies for atmosphere revitalization, water recovery, waste management, thermal control and crew accommodation that recover additional consumable mass, reduce requirements for power, volume, heat rejection, crew involvement, and which have increased reliability and capability. Other areas of focus include technologies for radiation protection, environmental monitoring and fire protection. Beyond LEO, return to Earth will be constrained. The potability of recycled water and purity of regenerated air must be measured and certified aboard the spacecraft. Missions must be able to recover from fire events through early detection, use of non-toxic suppression agents, and operation of recovery systems that protect on-board Environmental Control and Life Support (ECLS) hardware. Without the protection of the Earth s geomagnetic field, missions beyond LEO must have improved radiation shielding and dosimetry, as well as warning systems to protect the crew against solar particle events. This paper will describe plans for the new LSHS Foundational Domain and mission factors that will shape its technology development portfolio.

Barta, Daniel J.↗

Airborne Projection of Burning Embers – Planning and Controls for Los Alamos National Laboratory Facilities

As a result of the Las Conchas Fire, the Department of Energy in correspondence SO:32CK 372899 (DOE 2011) requested that LANS take the following action: Evaluate the Las Conchas fire experience and other data on airborne projection of burning embers and the appropriate planning and controls for Los Alamos National Laboratory (LANL) facilities, including nuclear and high hazard facilities. This paper addresses the DOE action by evaluating 1) the meteorology at the time of the accident and implications for new wild land fires; 2) the ability of LANL facilities to withstand fires as a result of burning embers, and 3) LANL programs in place to mitigate the effects of wild land fires. The spread of fire as a result of burning embers is a known and important mechanism. Both empirical and computational studies have been performed, and it is recognized that these studies should continue (Kim 2009, Koo 2010, Sardoy 2007). Due to the locale and environs of LANL, burning brands or embers from forest fires are a credible risk at LANL. With the exception of the Area G TRU Waste Facility, LANL nuclear facilities have fire resistant exteriors with UL Class A roofs. Waste at Area G is stored in fire resistant containers. The laboratory has comprehensive Emergency Operations and Fire Protection Programs, which includes assessing wildland fire risk and mitigating the spread of fires, for example, by maintaining fire breaks and additional defensible buffer areas free of combustibles around LANL facilities and limits on combustible loading. Vegetation is cut-back to at least national consensus standards on a regular basis around nuclear facilities. Fire Department services are provided by Los Alamos County through an agreement with the Department of Energy. The interface between the Fire Department and LANL during emergencies is the Emergency Operations Division. The ability of LANL facilities to withstand a wildland fire was tested by both the Cerro Grande fire in 2000 as well as the Las Conchas fire. No nuclear or high-hazard facilities were damaged even though the Cerro Grande fire burned around a number of the facilities. Since then, the laboratory has strengthened programs to protect against wildland fires.