Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Evaluation of a single cell and candidate materials with high water content hydrogen in a generic solid oxide fuel cell stack test fixture, Part II: materials and interface characterization

A generic solid oxide fuel cell (SOFC) test fixture was developed to evaluate candidate materials under realistic conditions. A commerical 50 mm x 50 mm NiO-YSZ anode supported thin YSZ electrolyte cell with lanthanum strontium manganite (LSM) cathode was tested to evaluate the stability of candidate materials. The cell was tested in two stages at 800oC: stage I of low (~3% H2O) humidity and stage II of high (~30% H2O) humidity hydrogen fuel at constant voltage or constant current mode. Part I of the work was published earlier with information of the generic test fixture design, materials, cell performance, and optical post-mortem analysis. In part II, detailed microstructure and interfacial characterizations are reported regarding the SOFC candidate materials: (Mn,Co)-spinel conductive coating, alumina coating for sealing area, ferritic stainless steel interconnect, refractory sealing glass, and their interactions with each other. Overall, the (Mn,Co)-spinel coating was very effective in minimizing Cr migration. No Cr was identified in the cathode after 1720h at 800oC. Aluminization of metallic interconnect also proved to be chemically compatible with alkaline-earth silicate sealing glass. The details of interfacial reaction and microstructure development are discussed.

(Mn,Co)-spinel↗

SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

60 APPLIED LIFE SCIENCES↗

Characterizing Dynamic Test Fixtures Through the Modal Projection Error

Across many industries and engineering disciplines, physical components and systems of components are designed and deployed into their environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will survive its physical environment or if it will fail due to mechanical stresses. One method to determine if the component will survive the environment is to expose the component to a simulation of the environment in a laboratory. One difficulty in doing this is that the component may not have the same boundary condition in the laboratory as is in the field configuration. This paper presents a novel method of quantifying the error in the modal domain that occurs from the impedance difference between the laboratory test fixture and the next level of assembly in the field configuration. The error is calculated from the projection from one mode shape space to the other, and the error is in terms of each mode of the field configuration. This provides insight into the effectiveness of the test fixture with respect to the ability to recreate the mode shapes of the field configuration. A case study is presented to show that the error in the modal projection between two configurations is a lower limit for the error that can be achieved by a laboratory test.

42 ENGINEERING↗

140° Line of Sight (LOS) Mounting Fixture Prototype for ZNeutron Time of Flight (Z-NToF)

The 140° Line of Sight (LOS) Mounting Fixture Prototype for the Z-Neutron Time of Flight diagnostic (Z-NToF) is a prototype support structure for the NToF Jac Black that will be fielded at Sandia’s Z-Machine. The Mounting Fixture will allow the detector to be properly positioned and aligned horizontally from the load, with manual horizontal and vertical translation capabilities, and a limited manual rotation capability. It attaches overhead I-beams at Sandia’s Z machine 140° location approximately 18m from the average source location. The assembly (1011219955) is shown in Figure 1 below. It is capable of rotating ±20° about the vertical axis of the Jac Black detector and translating ±37.5mm horizontally along the Mounting Plate. Vertical adjustments of ±76.2mm can be made using the Lead Screw. Coarser adjustments are possible by changing the number of plates between the I-Beam Hanger Assemblies and the 5in and changing the position of the clamps on the I-beams at Z.

42 ENGINEERING↗

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-aligning fixture used in lathe chuck jaw refacing

Self-aligning tool positions and rigidly holds lathe chuck jaws for refacing and truing of the clamping surface. The jaws clamp the fixture in the manner of clamping a workpiece. The fixture can be modified to accommodate four-jawed checks.

Linn, C. C.↗

Multisurface fixture permits easy grinding of tool bit angles

Multisurface fixture with a tool holder permits accurate grinding and finishing of right and left hand single point threading tools. All angles are ground by changing the fixture position to rest at various references angles without removing the tool from the holder.

Jones, C. R.↗

Cable clamp bolt fixture facilitates assembly in close quarters

Cable clamp bolt holding fixture facilitates forming of electrical cable runs in limited equipment space. The fixture engages the threads of the short clamp bolt through the clamp and maintains tension against clamp tendency to open while the operator installs the nut without difficulty.

Sunderland, G. H.↗

Machine tools and fixtures: A compilation

As part of NASA's Technology Utilizations Program, a compilation was made of technological developments regarding machine tools, jigs, and fixtures that have been produced, modified, or adapted to meet requirements of the aerospace program. The compilation is divided into three sections that include: (1) a variety of machine tool applications that offer easier and more efficient production techniques; (2) methods, techniques, and hardware that aid in the setup, alignment, and control of machines and machine tools to further quality assurance in finished products: and (3) jigs, fixtures, and adapters that are ancillary to basic machine tools and aid in realizing their greatest potential.

Source record↗

Spacecraft utensil/hand cleansing fixture

A system concept for an inflight utensil/hand cleansing fixture is described which includes the following features: (1) capability for efficient cleansing and rinsing of utensils or hands, and (2) provision for general waste fluid disposal. The design concept provides for the capability of functioning for a 30 day shuttle mission containing seven occupants/users. The long range goal is to provide a functioning system capable of operating for missions of at least 120 days. The fixture is a self-contained unit that can be installed in the standard water interface requirements. Service to the unit is a single source of unheated potable water and water is discharged from the unit into a single return waste connection. In addition, the design includes provisions for the intake and discharge of purge air and the discharge of evolved gases. Both the air and the gases are filtered or processed in the assembly before releasing them into the habitability area.

Rosener, A. A.↗

"Three-dimensional" vibration fixture

Simple cube-shaped fixture reduces vibration-test time to one-third required previously. Three units are supported at once. During one run each unit is tested along one of axes. Units are repositioned on second run for tests along different axes. Three runs complete test; fixture can be set up to test small, lightweight high-production units.

Schumacher, C. A.↗

Development of a ferromagnetic rotary vacuum sealed spacecraft spin fixture

A number of successful spacecraft tests were conducted on an environmental spin fixture which utilizes a ferrofluidic rotary vacuum seal. The 27 cm (10.5 inch) diameter fixture drive shaft supports and spins communications satellites during flight acceptance testing in a thermal vacuum chamber. The drive shaft rotary seal serves to maintain the canned drive system electro-mechanical components at ambient pressure within the space simulator. The ferromagnetic fluid seal was chosen over conventional mechanical sealing devices for its zero-leakage, zero-wear, and minimum friction drag characteristics, as well as its high reliability potential.

Levine, M. B.↗

X-band slotted array test panel and test fixture

Data from the development of the X-band slotted array test band, X-band array test fixture, and the X/L-band test fixture for the Support Instrumentation Requirements program are documented. An X-band array was built and installed with an existing L-band module in such a way as to permit antenna pattern measurements in a series of nonplanar configurations that might simulate the thermal effects of nonuniform solar illumination on the array in a space environment. This was accomplished with eight X-band subpanels mounted adjacently on individually adjusted supports which were then co-mounted to a larger frame which served to mount and physically distort the existing L-band module. The L-band module is a heavy electrical breadboard array section that was fabricated to demonstrate the performance capabilities of a slotted waveguide array at L-band frequencies. Drawings, mechanical analysis, and descriptions of test configurations are presented.

Source record↗

Honing fixture for welded electrodes

Fixture for refacing electrodes mounts directly on welding machine. Up-and-down movement of stone against electrode is done manually or with designed motor drive. Fixture is used in lieu of manually refinishing electrodes with emory paper or other abrasive. It produces uniformly flat, parallel electrodes in less time, saving cost on production time.

Nicholas, R. F.↗

Handling Fixture for Solar-Cell Arrays

Thin cells processed and stored safely. Major parts of handling fixture hold components of solar cell array modules safely, yet allow assembly process to proceed without interference. Fixture used with or without internal vacuum. Concept allows handling of thin, relatively-fragile cells, and offers potential for savings in silicon material and cost.

Dillard, P. A.↗

Description of a magnetic bearing test fixture

A description of a microcomputer controlled magnetic bearing test fixture is presented. Parameters which are controlled are magnetic bearing current and gaps. Parameters which are measured are magnetic bearing gaps, magnetic flux in the bearing gaps, and bearing forces. The test fixture is configured for bearing elements similar to those used in a laboratory test model Annular Momentum Control Device (AMCD).

Groom, Nelson J.↗