Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.

Arndt, G. D.↗

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.↗

Reduction of flow-measurement uncertainties in laser velocimeters with nonorthogonal channels

An analysis of certain geometrical limitations inherent in the application of laser velocimeters with nonorthogonal channels has led to the development of advanced-LDA-calibration and data-acquisition techniques that minimize systematic and statistical errors, respectively. The data-acquisition technique optimizes the number of velocity samples collected from three velocimeter channels as a function of local turbulence intensity, vector direction, and prescribed confidence interval. Linear velocity surveys and streamline traces measured in a turbulent flow field with a three-dimensional laser velocimeter are presented and the validity and accuracy of the theoretical analysis are discussed.

Snyder, P. K.↗

Flowmeter measures flow rates of high temperature fluids

Flowmeter in which flow rate is determined by measuring the position and thus the displacement of an internal float acted upon by the flowing fluid determines the flow rates of various liquid metals at elevated temperatures. Viscous forces cause the float to move from its mounted position, affording several means for measuring this motion and the flow rate.

Vary, A.↗

Microwave/Sonic Apparatus Measures Flow and Density in Pipe

An apparatus for measuring the rate of flow and the mass density of a liquid or slurry includes a special section of pipe instrumented with microwave and sonic sensors, and a computer that processes digitized readings taken by the sensors. The apparatus was conceived specifically for monitoring a flow of oil-well-drilling mud, but the basic principles of its design and operation are also applicable to monitoring flows of other liquids and slurries.

Arndt, G. D.↗

Aerothermodynamic Facilities And Measurement: Flow Characterization in Shock Tunnels

This presentation will examine the key performance aspects of shock tunnels as they relate to their use as aerothermodynamic flow simulation facilities. Assessment of shock tube reservoir conditions and flow contaminants generated in the shock tube will be presented along with their limiting impact on viable test envelopes, Facility nozzle performance as it pertains to test time assessment and nozzle exit flow quality (survey of pressure, temperature, and species) will be addressed. Also included will be a discussion of free stream flow diagnostics, both intrusive and nonintrusive, for measurement of critical flow properties not directly inferred from surface mounted transducers. The use of computational fluid dynamics for purposes of validating experimental measurements as well as predicting performance in regimes where measurements are not feasible or possible will be discussed. The use of CFD for facility research and design will also be presented.

Cavolowsky, John A.↗

Juncture flow measurements using laser velocimetry

The turbulent flow in a simulated wing-fuselage juncture has been investigated using Laser Velocimetry. The juncture was simulated by a splitter plate with an unswept wing model mounted perpendicular to it. The use of sharp wing leading edge results in the elimination of separation ahead of leading edge, and hence the separation vortex. Secondary flow induced by Reynolds stress gradients is the main source of vortical motion in the juncture formed by the plate and the flat surface of the wing, whereas in the juncture formed by the plate and the circular arc surface of the wing, streamwise vorticity is generated because of the presence of lateral curvature in the flow field. The results of this study indicate that fillets in the juncture can improve the flow characteristics near the wing trailing edge.

Kubendran, L. R.↗

Flow measurements in a turbine scroll

The paper presents a study conducted to determine experimentally the flow behavior in the combined scroll nozzle assembly of a radial inflow turbine. It is shown that hot film anemometry was used to measure the flow velocity in the scroll.

Tabakoff, W.↗

TEAMER – Enhanced Flow Measurement for Aquantis Tidal Turbine Test

The AQ10 is a floating, two-bladed, passive yawing tidal turbine developed by Aquantis that has a 10-meterrotor diameter, 160 kW rating, and employs reliable off-the-shelf powertrain and power conversion hardware. Aquantis is planning on-water turbine power performance and loads (blade loading and thrust)testing, where the turbine will be pushed through still water up to 4 knots and placed in a ‘station keeping’ tow in a tidal race up to its rated speed. On-water testing will be conducted using vessels and floating platforms on the sea surface to improve ease of testing and reduce disturbance to the environment. In this TEAMER project, Pacific Northwest National Laboratory (PNNL) will conduct water velocity and turbulence measurements in front of the turbine during on-water testing using acoustic Doppler instrumentation. By measuring both the tidal current flowing past the turbine and the resulting electrical power output, test results will provide a power curve (power vs flow speed) for the turbine up to rated power. Measurements of turbulence and velocity shear in front of the rotor will also provide information to assess the structural response of the rotor blades. With this analysis, Aquantis can use the performance and loads data to validate Tidal Bladed and OpenFAST simulations of the measured operating conditions. Measuring the power performance of a prototype turbine is a valuable step to improving device development and conducting a complete power performance assessment to IEC/TS 62600-200 standards in the future.

16 TIDAL AND WAVE POWER↗

Three dimensional flow measurements in a turbine scroll

A study was conducted to determine experimentally the flow behavior in combined scroll nozzle assembly of a radial inflow turbine. Hot film anemometry technique was used to measure the three dimensional flow velocity in the scroll. The through flow and secondary flow velocity components are measured at various points in three scroll sections.

Tabakoff, W.↗

Meter accurately measures flow of low-conductivity fluids

An electromagnetic flowmeter has been adjusted to minimize the errors inherent in measuring the flow of low conductivity fluids. This is done through use of a direct-coupled, differential cathode follower, whose grid potential is adjustable with respect to ground levels.

Love, E. G.↗

Three-dimensional flow measurements in a turbine scroll

A study was conducted to determine experimentally the flow behavior in combined scroll nozzle assembly of a radial inflow turbine. Hot film anemometry technique was used to measure the three-dimensional flow velocity in the scroll. The through-flow and secondary flow velocity components are measured at various points in three scroll sections.

Tabakoff, W.↗

Non-nulling seven-hole probes for high angle flow measurement

This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.

Gerner, A. A.↗

Local flow measurements at the inlet spike tip of a Mach 3 supersonic cruise airplane

The flow field at the left inlet spike tip of a YF-12A airplane was examined using at 26 deg included angle conical flow sensor to obtain measurements at free-stream Mach numbers from 1.6 to 3.0. Local flow angularity, Mach number, impact pressure, and mass flow were determined and compared with free-stream values. Local flow changes occurred at the same time as free-stream changes. The local flow usually approached the spike centerline from the upper outboard side because of spike cant and toe-in. Free-stream Mach number influenced the local flow angularity; as Mach number increased above 2.2, local angle of attack increased and local sideslip angle decreased. Local Mach number was generally 3 percent less than free-stream Mach number. Impact-pressure ratio and mass flow ratio increased as free-stream Mach number increased above 2.2, indicating a beneficial forebody compression effect. No degradation of the spike tip instrumentation was observed after more than 40 flights in the high-speed thermal environment encountered by the airplane. The sensor is rugged, simple, and sensitive to small flow changes. It can provide accurate imputs necessary to control an inlet.

Johnson, H. J.↗

New devices for flow measurements: Hot film and burial wire sensors, infrared imagery, liquid crystal, and piezo-electric model

An experimental program aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions is discussed. Implementing a new technique, a long electrically heated wire was placed across a laminar flow. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified.

Mcree, Griffith J., Jr.↗

Flow measurements in a water tunnel using a holocinematographic velocimeter

Dual-view holographic movies were used to examine complex flows with full three-space and time resolution. This approach, which tracks the movement of small tracer particles in water, is termed holocinematographic velocimetry (HCV). A small prototype of a new water tunnel was used to demonstrate proof-of-concept for the HCV. After utilizing a conventional flow visualization apparatus with a laser light sheet to illuminate tracer particles to evaluate flow quality of the prototype tunnel, a simplified version of the HCV was employed to demonstrate the capabilities of the approach. Results indicate that a full-scale version of the water tunnel and a high performance version of the HCV should be able to check theoretical and numerical modeling of complex flows and examine the mechanisms operative in turbulent and vortex flow control concepts, providing an entirely unique instrument capable, for the first time, of simultaneous three-space and time measurements in turbulent flow.

Weinstein, Leonard M.↗

Flow measurements in a model of the mildly curved femoral artery of man

The effects of curvature on the flow rate near the wall in the vicinity of the mildly curved femoral artery of man, and on the pressure distributions along the curved segment, were investigated using glass and tygon flow models constructed to conform to the shape of the femoral angiogram of a human subject. The test fluid was 33 percent aqueous sucrose. Steady flow observations, made using a dye flow visualization system, revealed a flow pattern like that observed in coiled pipes. A double helical type flow was found to develop, with converging streamlines in the wall vicinity from the upper and lower plane of curvature merging asymptotically along the inner curvature in a stable manner. Pressure measurements for steady flow revealed progressively larger pressure drops with distance along the entrance region of the curved segment, relative to that for a straight lumen.

Back, L. H.↗