Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Adjustable primary and supplemental power units

A propulsion system for an aircraft includes a core flow path in communication with a compressor section, combustor section and a turbine section. A first bottoming cycle system includes a bottoming working fluid flow in thermal communication with a high energy exhaust gas flow that is generated by the core engine. The first bottoming cycle is configured to recover power from the high energy exhaust gas flow in a first engine operating condition and in a second engine operating condition. A second bottoming cycle system is configured to recover power from the high energy exhaust gas flow in the first engine operating condition and not to recover power in a second engine operating condition.

MacDonald, Malcolm P.↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

Leakage From Coexisting Geologic Forcing and Injection‐Induced Pressurization: A Semi‐Analytical Solution for Multilayered Aquifers With Multiple Wells

Abstract Abnormal fluid pressures (above or below hydrostatic pressure) can develop and persist in sedimentary basins. The common occurrence of abnormal pressures may cause challenges for project permitting of geological carbon sequestration (GCS), particularly in reservoirs with pre‐injection overpressure. The leaky wells that may exist in some sedimentary basins can provide flow paths between deep brine aquifers and shallower freshwater aquifers. Pre‐injection relative overpressures can cause brine leakage through leaky wells even before any injection occurs. The tendency for flow through leaky wells is coupled with the process of pressure dissipation that occurs through aquitards. Specifically, with non‐zero permeability, aquitards can dissipate pressure over large areal extents and thereby reduce leakage rates through leaky wells. This study presents development of a semi‐analytical solution for hydraulic head and brine leakage in multilayered aquifer–aquitard systems with geologic pressure forcing. The geologic forcing that causes abnormal pressures in the multilayered system can coexist with any number of injection, extraction, and leaky wells that also affect fluid pressure. The semi‐analytical model is applied to explore how leakage through leaky wells varies as functions of pressurization rate, along with aquitard and leaky well properties in an overpressured multilayered system. The results show that although injection‐induced pressures can dissipate rapidly through suitably permeable aquitards, coexisting geologic forcing may create sustained rates of brine leakage into freshwater aquifers through leaky wells. In GCS, a very low‐permeability aquitard with high capillary entry pressure to free‐phase CO 2 is desired to serve as the caprock to prevent leakage of CO 2 from the storage reservoir. Nevertheless, the results from this study show that the brine leakage impact to shallow freshwater aquifers through leaky wells might substantially decrease with increasing aquitard permeability values, as long as small aquitard permeability and high capillary entry pressure serve to prevent CO 2 leakage.

Cihan, A.↗

Role of Intersections in Fracture Connectivity

Networks of intersecting fractures often provide the flow paths through subsurface reservoirs. Assessing network connectivity is challenging because fracture intersections compose a vanishingly small fraction of the network void volume. In this paper, motivated by 3D X-ray imaging of the simplest element of fracture network, that is, two orthogonal fractures, we perform a percolation and finite-size scaling analysis to study the connectivity provided by fracture intersections. The conditions when an intersection enhances connectivity across a sample depend on spatial correlations in the fracture aperture distributions, on the stress state, and on the direction of flow. Here we consider three flow directions: (a) across intersections, (b) parallel to intersections and (c) around corners. For (a), intersections provide minimal enhancement of connectivity because they contribute little additional void area. For (b), intersections increase the probability of a connected path near threshold by enabling 3D connected pathways that are not possible in parallel fractures. Flow around corners, (c), is fundamentally the result of the intersection connecting two fractures in series and spatial correlations are broken around corners, suppressing the connectivity relative to (a). When the connected fractures are stressed equally, a joint percolation threshold emerges that continues to have scale invariance. However, when the fractures are stressed unequally, the system has mixed percolation without clearly defined percolation thresholds. In all cases, percolation probabilities are found to be scale dependent which has important consequences for the connectivity of larger fracture networks composed of the fundamental element studied here.

02 PETROLEUM↗

Hydrologic Connectivity and Patch‐To‐Hillslope Scale Relations in Dryland Ecosystems

Abstract In drylands, runoff during storms redistributes water and nutrients from bare soil areas to vegetated patches, subsidizing vegetation with additional resources. The extent of this redistribution depends on the interplay between surface roughness and permeability; greater permeability in vegetated patches promotes run‐on to vegetation, but greater surface roughness diverts runoff, producing tortuous flow paths that bypass vegetation. Here, this interplay is examined in virtual experiments using the 2D Saint Venant Equations to measure runoff connectivity. Flowpaths are delineated using tracers advected by the flow. Distances between tracer sources and sinks along flowpaths measure hydrologic connectivity at two lengthscales: connectivity to the hillslope outlet and within‐slope source‐sink connectivity. Differences between these connectivity lengthscales indicate how flow may “by‐pass” vegetated patches within hillslopes. At the hillslope scale, a derived power‐law relation between the runoff coefficient and outlet connectivity describes hillslope water losses, providing a foundation for identifying landscapes likely to shed water.

54 ENVIRONMENTAL SCIENCES↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗

Geochemistry and Strontium Isotopes for Coal Creek Watershed, Colorado, 2021-2022

The geochemistry and strontium isotope data for Coal Creek Watershed, Colorado, consists of cation, anion, and 87Sr/87Sr isotope values from samples collected at 8 stream location along Coal Creek, samples from two groundwater springs within the watershed, and a shallow subsurface piezometer. All stream and spring samples were collected between June and October, 2021, and the shallow, near stream piezometer sample was collected in July of 2022. These data were collected to evaluate how groundwater contributions to Coal Creek originating from shallow vs deep flow paths respond seasonal drying. Understanding of groundwater-surface water interactions in montane systems in critical for the future of water availability in the Western US as groundwater contributions are expected to become more important for sustaining summer stream flows. This data package contains: (1) a csv of all cation samples; (2) a csv of all anion samples; (3) a csv of all 87Sr/87Sr isotope samples; and (4) a csv of locations for each sampling site. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.

54 ENVIRONMENTAL SCIENCES↗

Hydrological and Thermal Dynamics of a Supra‐Permafrost Subterranean Estuary

Subterranean estuaries (STEs), where groundwater interacts with seawater, influence surface and subsurface coastal ecology and biogeochemistry. In Arctic-STEs overlying permafrost, groundwater flow and heat transport determine the fate of organic matter. Yet, direct observations of groundwater flow and heat and solute transport processes in Arctic STEs remain limited. This study characterized groundwater flow paths and fluxes and heat transport within an Arctic-STE along Alaska's Beaufort Sea coast during thawing, summer, and freeze-up. Intertidal seabed temperature-depth profiles collected along a 10-m transect captured the active groundwater flow period, from thaw and flow onset in mid-June to freeze-up in late-September. During this period, aquifer geometry evolved non-uniformly due to spatially varying thaw rates across the STE (mean (m) thaw depths–beach: 0.25 to 0.55–0.6 m on 20 June, 25 July, 1 October; seabed: 0.6–0.9 m from 25 July to 1 October). Groundwater and surface water levels, salinity, and subsurface temperature profiles measured over tidal time scales were interpreted alongside groundwater flow-heat transport numerical simulations. Fresh groundwater discharge was sporadic during thawing (m: 0.32 m 3 /day/m), abundant in summer (m: 0.45 m 3 /day/m), and was largely absent during freeze-up. During freeze-up, groundwater flow was driven exclusively by seawater recirculation via tidal pumping (from thawing to summer to freeze-up: 0.00025–0.15–0.5 m3/day/m) and convection. Heat advection dominated near aquatic interfaces (shaping intertidal ice), and conduction controlled vertical temperature gradients in low-flow and unsaturated sediments. These findings will help predict how prolonged summers will alter Arctic-STE cryo-hydrology and biogeochemistry.

54 ENVIRONMENTAL SCIENCES↗

Emergence of Unstable Focused Flow Induced by Variable‐Density Flows in Vertical Fractures

Abstract Fluids with different densities often coexist in subsurface fractures and lead to variable‐density flows that control subsurface processes such as seawater intrusion, contaminant transport, and geologic carbon sequestration. In nature, fractures have dip angles relative to gravity, and density effects are maximized in vertical fractures. However, most studies on flow and transport through fractures are often limited to horizontal fractures. Here, we study the mixing and transport of variable‐density fluids in vertical fractures by combining three‐dimensional (3D) pore‐scale numerical simulations and visual laboratory experiments. Two miscible fluids with different densities are injected through two inlets at the bottom of a fracture and exit from an outlet at the top of the fracture. Laboratory experiments show the emergence of an unstable focused flow path, which we term a “runlet.” We successfully reproduce the unstable runlet using 3D numerical simulations and elucidate the underlying mechanisms triggering the runlet. Dimensionless number analysis shows that the runlet instability arises due to the Rayleigh‐Taylor instability (RTI), and flow topology analysis is applied to identify 3D vortices that are caused by the RTI. Even under laminar flow regimes, fluid inertia is shown to control the runlet instability by affecting the size and movement of vortices. Finally, we confirm the emergence of a runlet in rough‐walled fractures. Since a runlet dramatically affects fluid distribution, residence time, and mixing, the findings in this study have direct implications for the management of groundwater resources and subsurface applications.

Environmental Sciences & Ecology↗

Mineral Fabric as a Hidden Variable in Fracture Formation in Layered Media

Two longstanding goals in subsurface science are to induce fractures with a desired geometry and to adaptively control the interstitial geometry of existing fractures in response to changing subsurface conditions. Here, we demonstrate that microscopic mineral fabric and structure interact with macroscopic strain fields to generate emergent meso-scale geometries of induced fractures. These geometries define preferential directions of flow. Using additively manufactured rock, we demonstrate that highly conductive flow paths can be formed in tensile fractures by creating corrugated surfaces. Generation, suppression and enhancement of corrugations depend on the relative orientation between mineral fabric and layering. These insights into the role of micro-scale structure on macro-scale flow provide a new method for designing subsurface strategies to maximize potential production or to inhibit flow.

36 MATERIALS SCIENCE↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗

Fuel Injection Dynamics and Composition Effects on RDE Performance

Rotating detonation engines (RDEs) provide a promising route to substantially increasing cycle efficiency in stationary gas turbines. Much of this increase relies on the ability to achieve consistent pressure gain within the combustor. In particular, the design of injectors that feed fuel and air into the detonation channel plays a crucial role. Such injectors have to ensure proper mixing of fuel and oxidizer, while minimizing backflow of detonation products into the feed plenums, and reduce susceptibility to the complex wave structures that exist within the combustor. From a practical perspective, such RDEs also need to operate with variable fuel composition. When fuel mixtures with components that possess vastly different oxidation pathways and time-scales are used, there could be additional losses through deflagrative burning instead of detonation-driven heat release. Such sensitivity to the complete flow path is akin to the physics of thermoacoustic instabilities in conventional gas turbines. In this sense, RDEs pose a unique research challenge: the performance of the device relies on the small-scale heat release process, which is highly dependent on the flow interactions within the full-scale system. As a result, canonical flow configurations, instrumented with detailed diagnostics or modeled using high-fidelity tools, but only focus on the small-scale processes will not contain the key system-level interactions. At the same time, macroscopic measurements and models that only capture system-level performance will not provide insight into the key sources of pressure losses. These couplings and sensitivities provide a formidable challenge to both experimental and simulation studies of the effects Thus, a joint experimental/computational program designed specifically to address these challenges was undertaken in this program. The focus of this program was on two key topics: a) the interaction between injector flow and the overall wave dynamics within the combustor, and b) the deflagration/detonation structure in multi-component fuels that are of practical interest. Both topics involve interaction of small-scale heat release processes with the geometry-dependent wave structure. Studies focused on the study of full-scale RDE systems, based on a 6-inch conventional annular geometry. Experimentally RDEs were studied using a combination of diagnostics. A combination of optical diagnostics and aero-thermo-acoustic analysis based on a combination of spectral and mode decomposition analysis was used to identify the dynamics of the detonation wave and other secondary waves that exist in the system. These studies have helped the identification and investigation of injector and detonation dynamics arising from coupling, and how they affect RDE mixing, detonation structure, operability and performance. Performance of RDEs was investigated through thrust stand measurements, which was used to evaluate the effective pressure gain generated by the system through the concept of equivalent available pressure. Optical diagnostics were developed and implemented to investigate the distribution of heat release, across the detonation wave. Novel optical diagnostics of NIR imaging was also developed and applied to investigate the high temperature / high pressure distribution across the detonation wave. In order to complement the experiments, the computational tools were geared to simulate the full experimental setup. GPU-based acceleration of the models and computations were developed to enable rapid simulation of the full system. In addition, the use of adaptive mesh refinement, and unstructured grid formulation, enabled the investigation of realistic geometries studied in the laboratory. The simulations produced a wealth of detail on the structure of the detonation wave under different operating conditions. Emphasis was placed on quantifying mixture pre-burning and the impact on wave propagation and structure.

03 NATURAL GAS↗

Computing water flow through complex landscapes – Part 2: Finding hierarchies in depressions and morphological segmentations

Depressions – inwardly draining regions of digital elevation models – present difficulties for terrain analysis and hydrological modeling. Analogous “depressions” also arise in image processing and morphological segmentation, where they may represent noise, features of interest, or both. Here we provide a new data structure – the depression hierarchy – that captures the full topologic and topographic complexity of depressions in a region. We treat depressions as networks in a way that is analogous to surface-water flow paths, in which individual sub-depressions merge together to form meta-depressions in a process that continues until they begin to drain externally. This hierarchy can be used to selectively fill or breach depressions or to accelerate dynamic models of hydrological flow. Complete, well-commented, open-source code and correctness tests are available on GitHub and Zenodo.

54 ENVIRONMENTAL SCIENCES↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diabatic visualization shows effects of micro-fins on evaporation of R410A: Smooth, axial micro-fin, and helical micro-fin tubes

A novel approach to visualize the flow boiling inside a clear micro-fin tube under diabatic conditions is presented. Transparent smooth, axial micro-fin, and helical micro-fin tubes are made by 3D printing. The 3D printed tube is placed inside a glass tube and heated by the transparent secondary fluid flowing between the two tubes for providing the evaporation conditions and transparency. R410A flow boiling and the flow patterns in the three geometries captured with a high speed camera are compared. The experimental results show that micro-fin geometry influences flow behavior. Bubbles are mainly generated in the groove region due to a higher superheat than the fin region. Some of the liquid refrigerant is trapped in the grooves of the upper part of the micro-fin tube when the slug flow is present, and bubbles are generated in this thin liquid layer. In addition, the bubbles in the helical micro-fin tube are easier to merge because of the obstacle of the fin geometry for the bubble flowing path. As the two bubble merge, the conversion of surface free energy causes the bubble to travel with a higher velocity.

3D printed↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗