Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Megapixel Multi-band QWIP Focal Plane Arrays

A mid-wavelength 1024x1024 pixel quantum well infrared photodetector (QW) focal plane array has been demonstrated with excellent imagery. Noise equivalent differential temperature (NETD) of 19 mK was achieved at 95K operating temperature with f/2.5 optics at 300K background. This focal plane array has shown background limited performance (BLIP) at 90K operating temperature with the same optics and background conditions. In this paper, we will discuss its performance in quantum efficiency, NETD, uniformity, and operability.

focal plane arrays↗

Mercury-Cadmium-Telluride Focal Plane Array Performance Under Non-Standard Operating Conditions

This paper highlights a new technique that allows the Teledyne Scientific & Imaging LLC TCM6604A Mercury-Cadmium-Telluride (MCT) Focal Plane Array (FPA) to operate at room temperature. The Teledyne MCT FPA has been a standard in Imaging Spectroscopy since its creation in the 1980's. This FPA has been used in applications ranging from space instruments such as CRISM, M3 and ARTEMIS to airborne instruments such as MaRS and the Next Generation AVIRIS Instruments1. Precise focal plane alignment is always a challenge for such instruments. The current FPA alignment process results in multiple cold cycles requiring week-long durations, thereby increasing the risk and cost of a project. These alignment cycles are necessary because optimal alignment is approached incrementally and can only be measured with the FPA and Optics at standard operating conditions, requiring a cold instrument. Instruments using this FPA are normally cooled to temperatures below 150K for the MCT FPA to properly function. When the FPA is run at higher temperatures the dark current increases saturating the output. This paper covers the prospect of warm MCT FPA operation from a theoretical and experimental perspective. We discuss the empirical models and physical laws that govern MCT material properties and predict the optimal settings that will result in the best MCT PA performance at 300K. Theoretical results are then calculated for the proposed settings. We finally present the images and data obtained using the actual system with the warm MCT FPA settings. The paper concludes by emphasizing the strong positive correlation between the measured values and the theoretical results.

Focal Plane Array (FPA)↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Design of the SPT-SLIM Focal Plane: A Spectroscopic Imaging Array for the South Pole Telescope

The Summertime Line Intensity Mapper (SLIM) is a mm-wave line-intensity mapping (mm-LIM) experiment for the South Pole Telescope (SPT). The goal of SPT-SLIM is to serve as a technical and scientific pathfinder for the demonstration of the suitability and in-field performance of multi-pixel superconducting filterbank spectrometers for future mm-LIM experiments. Scheduled to deploy in the 2023-24 austral summer, the SPT-SLIM focal plane will include 18 dual-polarisation pixels, each coupled to an $R = \lambda / \Delta \lambda = 300$ thin-film microstrip filterbank spectrometer that spans the 2 mm atmospheric window (120–180 GHz). Each individual spectral channel feeds a microstrip-coupled lumped-element kinetic inductance detector, which provides the highly multiplexed readout for the 10k detectors needed for SPT-SLIM. Here, we present an overview of the preliminary design of key aspects of the SPT-SLIM focal plane array, a description of the detector architecture and predicted performance, and initial test results that will be used to inform the final design of the SPT-SLIM spectrometer array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Fault Architecture on Induced Earthquake Sequence Evolution Revealed by High-Resolution Focal Mechanism Solutions

The increasing seismicity and improved seismic observation network in recent years provide an opportunity to explore factors that influence the triggering processes, spatiotemporal evolution, and maximum magnitude of induced sequences. We map the fault architecture and stress state of four induced sequences in Oklahoma to determine their influence on the seismicity. We systematically relocate the earthquakes and compute hundreds of focal mechanisms of small to medium events (1.0 < M < 5.1) using various techniques, including machine learning, for the Guthrie, Woodward, Cushing, and Fairview sequences. The detailed fault geometry and spatiotemporal evolution of seismicity and stress states reveal different dominant driving forces for each sequence. In Cushing and Fairview (largest event ≥M5.0), the main fault structures are near-vertical narrow strike-slip faults, with most of the small earthquake fault planes optimally oriented. The two sequences exhibit discontinuous temporal migration but strong earthquake self-driven rupture growth. In Guthrie and Woodward (largest event <M5.0), the two sequences show more complex diffuse fault structures with varying dipping angles along depth. The inverted focal mechanisms show a mix of strike-slip faulting and normal faulting in both sequences, and the normal faulting events are less optimally oriented than strike-slip events. The two sequences are dominated by continuous diffusive migration in time driven by pore pressure propagation. The above results suggest that fault architecture and stress state influence sequence evolution, major driving forces, and possibly maximum magnitude.

58 GEOSCIENCES↗

Target normal sheath acceleration with a large laser focal diameter

In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θ L = 45°) and large focal spot size (w 0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. This deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vector meson photoproduction in UPCs with FoCal

Abstract We discuss the physics prospects of photon-induced measurements using the high-granularity FoCal detector to be installed at the ALICE experiment, covering the pseudorapidity interval 3.4 ≤ η ≤ 5.8. This new detector, scheduled to be in operation from Run 4, will explore the small Bjorken- x physics region in an unprecedented way. In this region the gluon ,saturation phenomenon is expected to be dominant. Combined with the rest of the ALICE subdetectors, including the zero degree calorimenters, FoCal will serve to reconstruct in a model-independent way the measured photoproduction cross sections for vectors mesons in a wide range of photon-target energies, down to x values of about 7 × 10 −6 and 2 × 10 −6 in ultra-peripheral photon–proton and photon–lead collisions, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the FOCAL Experimental Campaign

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within the floater's individual members. Consideration of local substructure loads is important for some floating designs, because the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

Spatio-temporal focal spot characterization and modeling of the NIF ARC kilojoule picosecond laser

The advanced radiographic capability (ARC) laser system, part of theNational Ignition Facility (NIF) at Lawrence Livermore National Laboratory, is a short-pulse laser capability integrated into the NIF. The ARC is designed to provide adjustable pulse lengths of ~1–38 ps in four independent beamlets, each with energies up to 1 kJ (depending on pulse duration). A detailed model of the ARC lasers has been developed that predicts the time- and space-resolved focal spots on target for each shot. Measurements made to characterize static and dynamic wavefront characteristics of the ARC are important inputs to the code. Modeling has been validated with measurements of the time-integrated focal spot at the target chamber center (TCC) at low power, and the space-integrated pulse duration at high power, using currently available diagnostics. In this work, these simulations indicate that each of the four ARC beamlets achieves a peak intensity on target of up to a few 10 18 W=cm 2 .

47 OTHER INSTRUMENTATION↗

Plasma mirror focal spot quality for glass and aluminum mirrors for laser pulses up to 20 ps

High-intensity short-pulse lasers are being pushed further as applications continue to demand higher laser intensities. Uses such as radiography and laser-driven particle acceleration require these higher intensities to produce the necessary x-ray and particle fluxes. Achieving these intensities, however, is limited by the damage threshold of costly optics and the complexity of target chambers. This is evidenced by the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory, producing four high-energy ≈1 kJ laser pulses at 30 ps pulse duration, being limited to an intensity of 10 18 W/cm 2 by the large focal spot size of ≈100 µm. Due to the setup complexity of NIF, changing the location of the final focusing parabola in order to improve the focal spot size is not an option. Therefore, this leads to the possible use of disposable ellipsoidal plasma mirrors (PMs) placed within the chamber, close to the target in an attempt to refocus the four ARC beams. However, the behavior of PMs at these relatively long pulse durations (tens of picoseconds) is not well characterized. The results from the COMET laser at the Jupiter Laser Facility carried out at 0.5 to 20 ps pulse durations on flat mirrors are presented as a necessary first step towards focusing curved mirrors. The findings show defocusing at longer pulse durations and higher intensities, with less degradation when using aluminum coated mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AmeriFlux FLUXNET-1F US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1. This is the FLUXNET version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1 produced by applying the standard ONEFlux (1F) software. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River. Landcover at the site is wetsedge (based on NSSI land cover map). During the first campaign (2013-2014), the tower location was 70.085450N; -148.570160W. It was moved to the current location (70.085050N, 148.567090W) during 2022 to 2024.

Krishnan, Praveena [NOAA/ARL/ATDD]↗

AmeriFlux FLUXNET-1F US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2. This is the FLUXNET version of the carbon flux data for the site US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2 produced by applying the standard ONEFlux (1F) software. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River

Krishnan, Praveena [NOAA/ARL/ATDD]↗

Joint Focal Mechanism Inversion Using Downhole and Surface Monitoring at the Decatur, Illinois, CO2 Injection Site

ABSTRACT The three-year CO2 injection period at the Illinois Basin - Decatur Project site (Decatur, Illinois, United States) produced a number of microseismic events distributed in very distinct spatiotemporal clusters with different orientations. Further characterization of the microseismicity encompasses the determination of the event source mechanisms. Initially, the microseismic monitoring network consisted solely of borehole sensors, but has been extended with surface sensors, thereby significantly improving the data coverage over the focal sphere. This article focuses on 23 events from the northernmost microseismic cluster (about 2 km from the injection point) and takes advantage of both, surface and downhole, recordings. The resulting strike-slip east–west-oriented focal planes are all consistent with the east–west orientation of the cluster in map view. The injection-related increase of pore pressure is far below the formation fracture pressure; however, small stress-field changes associated with the pore-pressure increase may reach as far as to the investigated cluster location. Monte Carlo modeling of the slip reactivation potential within this cluster showed that the observed maximum stress-field orientation of N068° is the optimum orientation for fault reactivation of the east–west-oriented cluster. Our results suggest that the east–west orientation of the investigated cluster is the main reason for its activation, even though the cluster is about 2 km away from the low-pressure injection point.

Geochemistry & Geophysics↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

FOCAL Campaign II/III: Applying Active Hull Controls Using Tuned-mass Dampers/Hull Flexibility and Internal Loads

Campaign II and III of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of the performance and loads of a scaled hull, with and without structural hull control. The floating platform was subjected to a variety of wave environments and controlled using tuned-mass dampers (TMDs) tuned to two of the systems natural frequencies (Platform Pitch and Tower-bending). The floating platform is fully instrumented to record a variety of parameters in real time such as platform dynamics, accelerations, and loads at different points in the structure. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. This testing was focused only on validation of wave loading, and wind conditions were not considered. As such the platform does not support a working turbine, and instead supports a structure designed to have the same mass properties as the 1:70 IEA 15MW Reference turbine. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Platform Static Offset (TMD off); LC 2.X - Platform Free-decays (TMD off); LC 3.X - Wave Cases (Regular Wave, Irregular Wave, Pink Noise Wave) with and without TMDs active. Detailed properties on the model system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaigns 2 and 3: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Hull. UMaine ASCC Report Number 23-56-1183.

17 WIND ENERGY↗

Electron beam deflected to determine focal point location

System locates the focal point of an extremely high intensity electron beam. The electron beam is swept and scanned cyclically with deflection coils under a focusing lens, causing the beam focal point to move so the locus of its positions is a spherical surface symmetrical to the beam axis.

Downing, R. D.↗

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A. focal plane camera

Trade studies were conducted to ensure the overall feasibility of the focal plane camera in a radial module. The primary variable in the trade studies was the location of the pickoff mirror, on axis versus off-axis. Two alternatives were: (1) the standard (electromagnetic focus) SECO submodule, and (2) the MOD 15 permanent magnet focus SECO submodule. The technical areas of concern were the packaging affected parameters of thermal dissipation, focal plane obscuration, and image quality.

Source record↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗