Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fresnel diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Two-photon polymerization printed lattices as support structures in multi-shell ICF targets: Platform development and initial assessment

Recent interest in fielding direct drive multi-shell targets on the NIF [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016) and S. X. Hu et al., Phys. Rev. E 100, 063204 (2019)] has highlighted the need for a low density structure to support the inner shell(s) and to avoid energy loss in the acceleration and collision process. We have developed a two-shell platform to evaluate the use of low density two-photon polymerization (2PP) printed lattices as a support structure between the shells. Here, 2PP structures are an attractive option because they can be produced at densities as low as 5 mg/cc, which is ideal for multi-shell targets, and their 3D structure can be tailored to the user's needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of a Fresnel axicon

We design and manufacture a Fresnel axicon (fraxicon) that generates a quasi-diffraction-free/Bessel beam with a large depth of field. The novel optical element is characterized with both coherent and incoherent light, and its behavior is compared with that of a classical axicon. While the fraxicon exhibits a strong interference pattern in the on-axis intensity distribution, it can be smoothed out when using broadband light, partial spatial coherence light, or by period randomization. As inexpensive, compact/lightweight, and low-absorption elements, fraxicons may find applications in imaging, illumination, and situations where low absorption and dispersion are important.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical scattering in coherent hard x-ray nanobeam Bragg diffraction

Unique intensity features arising from dynamical diffraction arise in coherent x-ray nanobeam diffraction patterns of crystals having thicknesses larger than the x-ray extinction depth or exhibiting combinations of nanoscale and mesoscale features. We demonstrate that dynamical scattering effects can be accurately predicted using an optical model combined with the Darwin theory of dynamical x-ray diffraction. The model includes the highly divergent coherent x-ray nanobeams produced by Fresnel zone plate focusing optics and accounts for primary extinction, multiple scattering, and absorption. Furthermore, the simulation accurately reproduces the dynamical scattering features of experimental diffraction patterns acquired from a GaAs/AlGaAs epitaxial heterostructure on a GaAs (001) substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling kinematical x-ray diffraction excited by a coherent nanobeam.

A rigorous model of a diffraction experiment utilizing a coherent, monochromatic, X-ray beam, focused by a Fresnel zone plate onto a thin, perfect, single-crystal layer is presented. In this model, first the coherent wave emanating from an ideal zone plate equipped with a direct-beam stop and order-sorting aperture is computed. Then, diffraction of the focused wavefront by a thin silicon film positioned at the primary focal spot is calculated. This diffracted wavefront is propagated to the detector position, and the intensity distribution at the detector plane is extracted. The predictions of this model agree quite well with experimental data measured at the Center for Nanoscale Materials nanoprobe instrument at Sector 26 of the Advanced Photon Source.

43 PARTICLE ACCELERATORS↗

More are better, but the details matter: combinations of multiple Fresnel zone plates for improved resolution and efficiency in X-ray microscopy

Fresnel zone plates used for X-ray nanofocusing face high-aspect-ratio nanofabrication challenges in combining narrow transverse features (for high spatial resolution) along with extended optical modulation along the X-ray beam direction (to improve efficiency). The stacking of multiple Fresnel zone plates along the beam direction has already been shown to offer improved characteristics of resolution and efficiency when compared with thin single zone plates. Using multislice wave propagation simulation methods, here a number of new schemes for the stacking of multiple Fresnel zone plates are considered. These include consideration of optimal thickness and spacing in the axial direction, and methods to capture a fraction of the light otherwise diffracted into unwanted orders, and instead bring it into the desired first-order focus. In conclusion, the alignment tolerances for stacking multiple Fresnel zone plates are also considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient modeling of Bragg coherent x-ray nanobeam diffraction

X-ray Bragg diffraction experiments that utilize tightly focused coherent beams produce complicated Bragg diffraction patterns that depend on scattering geometry, characteristics of the sample, and properties of the x-ray focusing optic. In this paper, we use a Fourier-transform-based method of modeling the 2D intensity distribution of a Bragg peak and apply it to the case of thin films illuminated with a Fresnel zone plate in three different Bragg scattering geometries. Finally, the calculations agree well with experimental coherent diffraction patterns, demonstrating that nanodiffraction patterns can be modeled at nonsymmetric Bragg conditions with this approach—a capability critical for advancing nanofocused x-ray diffraction microscopy.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Fabrication of hard x-ray zone plates with high aspect ratio using metal-assisted chemical etching

Fresnel zone plates are widely used as nanofocusing optics for x-ray microscopy, where the spatial resolution is set by the width of the finest rings while the efficiency is set by their thickness. This leads to the requirement for high aspect ratio nanofabrication. Metal-assisted chemical etching and atomic layer deposition has already been used to produce high aspect ratio zone plate structures on un-thinned silicon wafers. We demonstrate here a substantial improvement on the achieved aspect ratio up to a value of 500:1, by producing 16 nm wide platinum zones with thicknesses up to 8 µm. At the same time, the silicon substrate was thinned to 15 µm as required for a practically useful optic. First tests have shown 4.8% diffraction efficiency using 20 keV X rays. This x-ray focusing efficiency is higher than most Fresnel zone plates for this photon energy and near what has been achieved with multilayer-coated Kirkpatrick-Baez mirrors, and multilayer Laue lenses. Hard x-ray zone plates offer the advantages of easy alignment, energy tunability, and one can make many zone plates in a batch on a single silicon chip.

Fresnel zone plates↗

Thin Fresnel zone plate lenses for focusing underwater sound

A Fresnel zone plate (FZP) lens of the Soret type creates a focus by constructive interference of waves diffracted through open annular zones in an opaque screen. For underwater sound below MHz frequencies, a large FZP that blocks sound using high-impedance, dense materials would have practical disadvantages. We experimentally and numerically investigate an alternative approach of creating a FZP with thin (0.4λ) acoustically opaque zones made of soft silicone rubber foam attached to a thin (0.1λ) transparent rubber substrate. An ultra-thin (0.0068λ) FZP that achieves higher gain is also proposed and simulated which uses low-volume fraction, bubble-like resonant air ring cavities to construct opaque zones. Laboratory measurements at 200 kHz indicate that the rubber foam can be accurately modeled as a lossy fluid with an acoustic impedance approximately 1/10 that of water. Measured focal gains up to 20 dB agree with theoretical predictions for normal and oblique incidence. The measured focal radius of 0.68λ (peak-to-null) agrees with the Rayleigh diffraction limit prediction of 0.61 λ/NA (NA = 0.88) for a low-aberration lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Possibility of corrector plate tuning of x-ray focusing

Schemes for focusing a hard x-ray beam to a small spot are described. The theoretical minimum spot size, assuming perfect mirror shape, is shown to be 4 nm FWHM, independent of x-ray wavelength. This is less than the 10 nm previously said to be the minimum achievable diffraction-limited x-ray spot size. While providing the penetrating power only possible with x rays, this approaches the resolution needed to image individual atoms or atomic layers. However, the perfect mirror assumption is physically unrealistic. This paper discusses the compensation of mirror shape errors by a corrector plate and shows that the tolerances for corrector plate shape are far looser than are tolerances for mirror shape. The full eventual success of achieving theoretical minimum resolution will require mirror shape precision considerably better than has been achieved at this time, though far looser than would be required for simpleminded paraboloidal focusing. Two variants of the scheme, subject to the same mathematical treatment, are described. (i) The ''corrector plate'' name is copied from the similarly functioning element of the same name in a Schmidt camera. The focusing is achieved using glancing, yet coherent, reflection from a high-Z paraboloidal mirror. The strategy is to obtain dominant focusing from reflection and to compensate with weak refractive focusing. The reflective focusing is strong and achromatic but insufficiently accurate. The refractive focusing is weak and chromatic but highly accurate. The corrector plate improves resolution the way eyeglasses help a person to see. It can, for example, be ''fitted'' the same trial-and-error way an optometrist establishes a prescription for glasses. Dimensional tolerances for the compensator are far looser than would be needed for a mirror to achieve the same resolution. Unlike compound refractive lenses, attenuation will be small, at least for wavelengths longer than 1 A, because the compensation layer is thin. (ii) For this variant, the corrector plate is a washer-shaped refractive or Fresnel lens, and the mirror is (theoretically) a perfect cone. All focusing is provided by the lens. Even though the cone provides no focusing, it improves the resolution by increasing the numerical aperture of the device. Compared to a paraboloidal shape, it is assumed that the conical shape can be more accurately fabricated. Of the two variants, only the first variant is, in principle, capable of achieving the theoretical minimum resolution. Configurations are suggested, in both case (i) and case (ii), that use currently possible construction precisions to produce resolutions better than have been achieved to date. However, both results will remain well above the theoretical minimum until fabrication techniques have been developed that provide greater precision than is possible at this time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient E-Beam Lithography Exposure Strategies for Diffractive X-ray Optics

Exposure of structures with rotational symmetry by means of electron beam lithography is not trivial, because the e-beam writers are usually designed to deal with the data defined in Cartesian coordinates. Fabrication of circular nanostructures like Fresnel zone plates (FZPs) for x-ray microscopy applications requires exposures with resolution well below 1 nm. Therefore, special attention has to be paid to the efficient exposure data preparation, which will guarantee required precision and allow keeping the exposure time low. In this article, we describe in detail an optimized strategy that was applied for exposure of FZPs by the Vistec EBPG5000Plus e-beam lithography tool. Direct programming of exposure files allowed us to use fully the capabilities of this e-beam writer to expose efficiently and reproducibly FZPs with desired characteristics in both positive and negative tone resists.

43 PARTICLE ACCELERATORS↗

The Focus of an Ultraintense Laser Pulse

Back in 1885, von Lommel studied the diffraction of a circular opening. His study was one step further than the Airy diffraction model (describing patterns in the focal plane) because von Lommel’s model was able to describe what the light distribution before and after the focus is. Today’s extreme lasers have a flat-top profile whose diffraction pattern in the vicinity of the focus is very much reminiscent of von Lommel’s description. In the present Chapter, we will compute, based on a Huygens-Fresnel integral method, the laser field distribution around the focus. This modelling is particularly important because the intensity distribution before and after the focal plane (where the Airy disk exists) is very relevant to many contemporary experiments, and is key to the ionization of atoms and the dynamics of liberated electrons. For clarity, we are going to analyze three cases corresponding to three f-numbers: f/10, f/1.8, and f/1.1. Our computed results reveal the present-day significance of von Lommel’s pioneering results. Here, they help us understand the light distribution in the entire focal region of an ultraintense laser pulse including the full vectorial fields, not just the focal plane.

Roso, Luis [Universidad de Salamanca (Spain)]↗

Highly sensitive nonlinear luminescent ceramics for volumetric and multilayer data carriers

The interaction of optical ceramics based on wide-bandgap crystals with near-IR femtosecond laser radiation is studied experimentally. The formation of luminescent centres in LiF and MgF{sub 2} ceramics under the action of single laser pulses is considered. Two interaction regimes are used. In the regime of low-aperture focusing of laser radiation (800 nm, 30 fs, 0.3 mJ), multiple selffocusing and filamentation in the samples are observed. The luminescent centres are formed in thin channels induced by light filaments. The average effective self-focusing length is ∼100 μm; the formation of luminescent centres begins at this length and ceases at a wavelength of about 380 mm. The luminescent trace (spur) induced by a single laser filament was ∼30 μm long and 1.3 μm in diameter. The second regime of light interaction with the sample was based on high-aperture focusing with a simultaneous decrease in the laser pulse energy. This led to the formation of single pits with a diameter smaller than the optical diffraction limit. The luminescent centres induced by the laser radiation were aggregated colour centres. The mechanism of their creation included the highly-nonlinear generation of electron – hole pairs in the filamentation region, their recombination with the formation of anion excitons and the decay of excitons into Fresnel defects by the Lushchik – Vitol – Hersh – Pooley mechanism, as well as their recharging, migration and aggregation. (laser applications and other topics in quantum electronics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water

We report the nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating immersed in water. In the linear regime, the system presents high focal gain (32 dB), with a narrow beam-width and intense side lobes as it is common in focusing by Fresnel-like lenses. Activating the nonlinearity of the host medium by using high amplitude incident waves, the focusing properties of the lens dramatically change. Theoretical predictions show that the focal gain of the system extraordinary increases in the strongly nonlinear regime (Mach number of 6.1 × 10{sup −4}). Particularly, the harmonic generation is locally activated at the focal spot, and the second harmonic beam is characterized by strongly reduced side-lobes and an excellent beam profile as experiments show in agreement with theory. The results can motivate applications in medical therapy or second harmonic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗