Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frisch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Effect of step stiffness and diffusion anisotropy on dynamics of vicinal surfaces: A competing growth process

We re-examine the step meandering instability which is described in term of solutions to the Conserved Kuramoto-Sivashinsky (CKS) equation [Frisch and Verga, Phys. Rev. Lett. 96, 166104 (2006)]. A free-boundary approach is used to exhibit a class of exact solutions that may give a reasonable description of the observed characteristic features of the instability. Different scenarios are found: the characteristic lateral coarsening (i) grows with time like sq root(t) (typical behavior), (ii) disappears, (iii) or does not change for all time (localization in space), depending on the initial transverse meandering amplitude k{sub 0}, or the initial typical height. Those regimes are compared by the numerical simulations presented in the literature. For case (ii) the collapsing time is expressed as an algebraic function of k{sub 0}.

36 MATERIALS SCIENCE↗

Fragment-mass distributions in neutron-induced fission of {sup 232}Th and {sup 238}U at 33, 45, and 60 MeV

We have measured fission fragment-mass yields for neutron-induced fission of {sup 232}Th and {sup 238}U at energies 32.8, 45.3, and 59.9 MeV. The experiments were done at quasimonoenergetic neutron beams of the Cyclotron Research Center at Louvain-la-Neuve. To detect the fission fragments, a multisection Frisch-gridded ionization chamber was used. The measurement and data analysis techniques are discussed in detail. The obtained mass yields are compared to model calculations with the intermediate-energy nuclear reaction code MCFX. The MCFX code is used to calculate the fraction of fissioning nuclei after cascade, preequilibrium, and statistical reaction stages. The formation of mass distributions is considered as a result of oscillations of the mass-asymmetry degree of freedom in the potential well calculated with the temperature-dependent shell correction method. The experimental results as well as the results of the model calculations demonstrate that the probability of symmetric fission increases with incident neutron energy for both nuclei. The comparison also shows that the symmetric fission is more enhanced for thorium than for uranium with increasing neutron energy. We also compare {sup 238}U results with available experimental data; the {sup 232}Th data were measured for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

Measurement of the cross section for the reaction {sup 20}Ne(n,{alpha}){sup 17}O in the neutron-energy between 4 and 7 MeV

The cross section for the reaction {sup 20}Ne(n, {alpha}){sup 17}O was measured in the neutron-energy range 4-7 MeV. An ionization chamber equipped with a Frisch grid combined with a pulse-shape digitizer was used as a detector. Gaseous neon that served as a target on which the reaction being studied proceeded was added to the gas filling the ionization chamber. The partial cross sections for the {alpha}{sub 0}, {alpha}{sub 1}, {alpha}{sub 2}, and {alpha}{sub 3} channels of the reaction {sup 20}Ne(n, {alpha}){sup 17}O were obtained for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments with the Dragon Machine [Slides]

A summary and compilation of the first super-prompt-critical experiments performed in the early days of the Manhattan Project by Otto Frisch, Louis Slotin, Philip Morrison, and others.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extending Measurements to En=30 MeV and Beyond

The majority of energy release in the fission process is due to the kinetic energy of the fission fragments. Average Total Kinetic Energy measurements for the major actinides over a wide range of incident neutron energies were performed at LANSCE using a Frisch-gridded ionization chamber. The experiments and results of the 238U(n,f) and 235U(n,f) will be presented, including (En), (A), and mass yield distributions as a function of neutron energy. A preliminary (En) for 239Pu(n,f) will also be shown. The (En) shows a clear structure at multichance fission thresholds for all the reactions that we studied. The fragment masses are determined using the iterative double energy (2E) method, with a resolution of A = 4 - 5 amu. The correction for the prompt fission neutrons is the main source of uncertainty, especially at high incident neutron energies, since the behavior of nubar(A,En) is largely unknown. Different correction methods will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CZT nanoRAIDER_VFG Factsheet

Brookhaven National Laboratory (BNL) is working with FLIR System Inc., the manufacturer of the nanoRAIDER, to design a handheld device based on a position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detector array (with 1% or better energy resolution). The new device called nanoRAIDER VFG will be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER will significantly improve the accuracy while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER VFG for safeguards is anticipated. The nanoRAIDER VFG will help address several items listed in the IAEA’s Long-Term R&D Plan that could enhance the abilities to detect undeclared nuclear material and activities.

36 MATERIALS SCIENCE↗

High-Efficiency CdZnTe Position-Sensitive VFG Gamma-Ray Detectors for Safeguards Applications

The goal of this project is to incorporate a Cadmium-Zinc-Telluride (CdZnTe or CZT) detector (with 1% or better resolution) into a bench-top prototype for isotope identification and related safeguards applications. The bench-top system is based on a 2x2 array of 6x6x20 mm 3 position-sensitive virtual Frisch-grid (VFG) CZT detectors. The key features of the array are that it allows for the use of average-grade CZT material with a moderate content of defects, and yet it provides high energy resolution, 1% FWHM at 662 keV, large effective area, and low-power consumption. The development of this type of 3D detector and new instruments incorporating them is motivated by the high cost and low availability of large, > 1 cm 3 , CZT crystals suitable for making multi-pixel detectors with acceptable energy resolution and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading FLIR NanoRaider with the next Generation of CdZnTe Detectors. Goal - Integrate VFG detectors into FLIR R200. Advanced Virtual Grid ASIC (AVG-ASIC).

This document presents motivations, goals and the current status of this project; development (fabrication, performance) of position-sensitive virtual Frisch-grid detectors proposed for nanoRaider, an instrument commonly used by nuclear inspectors; ASIC developments for CZT detectors; and the electronics development for the detector prototype..

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total Kinetic Energy and Fragment Mass Distribution of Neutron-Induced Fission of U-233

Properties of fission in U-233 were studied at the Los Alamos Neutron Science Center (LANSCE) at incident neutron energies from thermal to 40 MeV at both the Lujan Neutron Scattering Center flight path 12 and at WNR flight path 90-Left from Dec 2016 to Jan 2017. Fission fragments are observed in coincidence using a twin ionization chamber with Frisch grids. The average total kinetic energy (TKE) released from fission and fragment mass distributions are calculated from observations of energy deposited in the detector and conservation of mass and momentum. Accurate experimental measurements of these parameters are necessary to better understand the fission process and obtain data necessary for calculating criticality. The average TKE released from fission has been well characterized for several isotopes at thermal neutron energy, however, few measurements have been made at fast neutron energies. This experiment expands on previous successful experiments using an ionization chamber to measure TKE and fragment mass distributions of U-235, U-238, and Pu-239. This experiment requires the full spectrum of neutron energies and can therefore only be performed at a small number of facilities in the world. The required full neutron energy spectrum is obtained by combining measurements from WNR 90L and Lujan FP12 at LANSCE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Array Detector Modules for Spent Fuel Verification

Brookhaven National Laboratory (BNL) proposes to evaluate the arrays of position-sensitive virtual Frisch-grid (VFG) detectors for passive gamma-ray emission tomography (ET) to verify the spent fuel in storage casks before storing them in geo-repositories. Our primary objective is to conduct a preliminary analysis of the arrays capabilities and to perform field measurements to validate the effectiveness of the proposed array modules. The outcome of this proposal will consist of baseline designs for the future ET system which can ultimately be used together with neutrons detectors. This will demonstrate the usage of this technology in spent fuel storage casks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The British Mission at Los Alamos [Slides]

Fission was first produced in Nazi Germany in 1938. Einstein warned FDR in a letter dated August 2, 1939, but Germany invaded Poland on September 1, 1939. In spring 1940, the Frisch-Peierls Memo was completed. The Battle of Britain began in July 1940. The attached detailed report concerns the possibility of constructing a ‘super-bomb’ which utilises the energy stored in atomic nuclei as a source of energy. The energy liberated in the explosion of such a super-bomb is about the same as that produced by the explosion of 1,000 tons of dynamite.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fission with Exotic Nuclei (Abbreviated Report)

Nuclear fission is a key mechanism involved in the synthesis of heavy elements in the Cosmos and is the primary explanation for the stability of superheavy elements. Nevertheless, our knowledge of fission remains extremely fragmented. Most experiments have been conducted only on a tiny number of stable actinide nuclei and are often incomplete, leading to gaps in our basic understanding of the process. For many radioactive isotopes, basic fission data such as the charge or mass distribution of the fragments is unknown. These gaps cannot always be filled by simulation alone. Common fission models contain too many free parameters and lack predictive power. In contrast, the fundamental theory of fission under development at LLNL is much more predictive, but its current computational cost is too high to be used extensively for data evaluations. A unique window of opportunity to resolve these limitations has recently opened: the U.S. nuclear science community is ramping up major experimental programs at the Facility for Rare Isotope Beams (FRIB, the DOE flagship facility in low-energy nuclear science), and techniques from machine learning have shown great potential to simplify the use of a fundamental, quantum-mechanical theory of fission. This project has two components. On the experimental side, we acquired and deployed at the HIGS facility a new dual Frisch-Grid ionization chamber to measure correlated fragment-mass, kinetic energy, and angular distributions of fission fragments from induced fission. This new device was used to perform measurements of charge, mass and total kinetic energy of fission fragments in the photofission of 238 U and eight gamma-ray beam energies between 6.2 and 13 MeV, which allowed extracting high-precision independent yields for this reaction. The device was also used to perform measurements of the same quantities in the neutron-induced fission of 234 U with monoenergetic beams of energy between 5 and 8 MeV. In parallel, we collaborated with a team at Commissariat à l’énergie atomique et aux énergies alternatives (CEA) to perform a series of measurements of fission yields in inverse kinematics for the two isotopes of 236 U and 240 Pu. The experiment took place at the Grand Accélérateur National d’Ions Lourds in France in June 2023. The deployment of the VAMOS spectrometer with a new array called PISTA allowed determining the excitation energy of the fissioning system within 1 Mega-electronvolts. The second component of the project involved using deep neural networks to build fast and reliable emulators of our current fission models. In an invited paper published in Frontier in Physics, we showed that autoencoders could successfully compress nuclear wavefunctions in nuclear density functional theory. We achieved a dimensionality reduction of the order of two orders of magnitude while keeping the error in the total energy to less than 0.01%. In a second paper submitted to Physical Review Letters in June 2023 with our collaborators at CEA, we showed that variational autoencoders can learn the collective degrees of freedom driving the fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗