Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS COOLING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A quality monitor and monitoring technique employing optically stimulated electron emission

A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.

Yost, William T.↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

To support the eventual development of a nuclear thermal rocket engine, a state-of-the-art experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The test device simulates the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner as to accurately reproduce the temperatures and heat fluxes normally expected to occur as a result of nuclear fission while at the same time being exposed to flowing hydrogen. This project is referred to as the Nuclear Thermal Rocket Element Environment Simulator or NTREES. The NTREES device is located at the Marshall Space flight Center in a laboratory which has been modified to accommodate the high powers required to heat the test articles to the required temperatures and to handle the gaseous hydrogen flow required for the tests. Other modifications to the laboratory include the installation of a nitrogen gas supply system and a cooling water supply system. During the design and construction of the facility, every effort was made to comply with all pertinent regulations to provide assurance that the facility could be operated in a safe and efficient manner. The NTREES system can currently supply up to 50 kW of inductive heating to the fuel test articles, although the facility has been sized to eventually allow test article heating levels of up to several megawatts.

Emrich, William J., Jr.↗

Automated Electrostatics Environmental Chamber

The Mars Electrostatics Chamber (MEC) is an environmental chamber designed primarily to create atmospheric conditions like those at the surface of Mars to support experiments on electrostatic effects in the Martian environment. The chamber is equipped with a vacuum system, a cryogenic cooling system, an atmospheric-gas replenishing and analysis system, and a computerized control system that can be programmed by the user and that provides both automation and options for manual control. The control system can be set to maintain steady Mars-like conditions or to impose temperature and pressure variations of a Mars diurnal cycle at any given season and latitude. In addition, the MEC can be used in other areas of research because it can create steady or varying atmospheric conditions anywhere within the wide temperature, pressure, and composition ranges between the extremes of Mars-like and Earth-like conditions.

Calle, Carlos↗

Multimegawatt Nuclear Power System for Lunar Base Applications

A multimegawatt nuclear power system for lunar surface applications is presented. The design requirements were to produce 3 MWe on the Moon for an operational lifetime of 10 years without human intervention. The system uses an inert-gas-cooled fuel pin reactor as the heat source, a regenerative Brayton cycle as the power converter and a liquid droplet radiator as the thermal management system, and has a specific power of 66 W/kg.

B Trueblood↗

Multimegawatt nuclear power system for lunar base applications

This report describes a conceptual design for a multimegawatt lunar-based nuclear power system developed by students in the Space Systems Design course at the University of Washington. The design requirements are to produce 3 MWe for an operational lifetime of 10 years without human intervention. The system utilizes an inert-gas-cooled fuel-pin reactor as the heat source, a regenerative Brayton cycle as the power converter and a liquid droplet radiator as the thermal management system, and has a specific power of 66 W/kg. The unique requirements of a lunar base on shielding and siting of a nuclear reactor are discussed. The structural elements, though large, have a relatively small total mass and the liquid droplet radiator is highly adaptable to the moon due to the positive effects of lunar gravity on the droplet collection process.

Panchyshyn, M.↗

Thermally Simulated Testing of a Direct-Drive Gas-Cooled Nuclear Reactor

This paper describes the concept and preliminary component testing of a gas-cooled, UN-fueled, pin-type reactor which uses He/Xe gas that goes directly into a recuperated Brayton system to produce electricity for nuclear electric propulsion. This Direct-Drive Gas-Cooled Reactor (DDG) is designed to be subcritical under water or wet-sand immersion in case of a launch accident. Because the gas-cooled reactor can directly drive the Brayton turbomachinery, it is possible to configure the system such that there are no external surfaces or pressure boundaries that are refractory metal, even though the gas delivered to the turbine is 1144 K. The He/Xe gas mixture is a good heat transport medium when flowing, and a good insulator when stagnant. Judicious use of stagnant cavities as insulating regions allows transport of the 1144-K gas while keeping all external surfaces below 900 K. At this temperature super-alloys (Hastelloy or Inconel) can be used instead of refractory metals. Super-alloys reduce the technology risk because they are easier to fabricate than refractory metals, we have a much more extensive knowledge base on their characteristics, and, because they have a greater resistance to oxidation, system testing is eased. The system is also relatively simple in its design: no additional coolant pumps, heat exchanger, or freeze-thaw systems are required. Key to success of this concept is a good knowledge of the heat transfer between the fuel pins and the gas, as well as the pressure drop through the system. This paper describes preliminary testing to obtain this key information, as well as experience in demonstrating electrical thermal simulation of reactor components and concepts.

Godfroy, Thomas↗

Personal cooling systems: Possibilities and limitations

Personal thermal control by means of gas- or liquid-conditioned garments was developed during the 1960s and has been applied in a variety of aerospace and industrial settings. Both USAF fighter pilots and astronauts are required to wear heavy protective clothing which insulates them from the environment and thus creates stress through storage of metabolic heat. The problem is particularly severe in astronauts who perform heavy physical work during extra-vehicular activity (EVA); without artificial cooling they could reach incapacitating hyperthermia in a matter of minutes. This paper reviews the factors which influence the design of personal cooling systems. An important early step is determination of acceptable heat stress level, taking into account possible interactions of heat stress with other physiological problems such as motion sickness, diminished plasma volume, decompression sickness and acceleration tolerance. Other factors which require consideration include the work schedule, the area to be covered by the cooling garment, and the practicalities of a fixed or body-mounted heat sink and its power source. Nearly every imaginable heat sink has been proposed or tried over the past 30 years, including direct gas systems, phase-change systems with open or closed loops and thermoelectric heat sinks. The latter are now the system of choice for aircraft.

Nunneley, Sarah A.↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Unitized Regenerative Fuel Cell System Dryer-Humidifier Analytical Model Development

A Unitized Regenerative Fuel Cell (URFC) Energy Storage System is being developed at the NASA Glenn Research Center. This URFC system is unique in that it uses regenerative gas dryers/humidifiers that are mounted on the surface of the gas storage tanks that act as the radiators for thermal control of the URFC system. As the gas storage tanks cool down during URFC charging the regenerative gas dryers/humidifiers dry the hydrogen and oxygen gases produced by electrolysis. As the gas storage tanks heat up during URFC discharging, the regenerative gas dryers/humidifiers humidify the hydrogen and oxygen gases used by fuel cell. An analytical model was developed to simulate the URFC system's regenerative gas dryers/humidifiers. The model is in the form of an EXCEL@ worksheet that allows the investigation of the regenerative gas dryers/humidifier performance as a function of time and position within the regenerative gas dryers/humidifiers, as well as other key system variables. Finite Element Analysis (FEA) modeling of the regenerative gas dryers/humidifier and gas storage tank wall was also done to analyze spatial temperature distribution within the regenerative gas dryers/humidifiers and the localized tank wall. Test results obtained from the testing of the regenerative gas dryers/humidifiers in a thermal vacuum environment were used to corroborate the analyses.

Burke, Kenneth A.↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Thermal Fluid Modeling Approaches in SAM for High Temperature Gas-Cooled Reactor Applications

This paper provides an overview of the unique modeling and simulation challenges and needs in the system and safety analysis of two common types of High Temperature Gas-cooled Reactor (HTGR) designs. The challenges are associated with the complex core geometry configurations and the change of the dominant heat removal mechanisms between normal operating conditions and decay heat removal transients. This requires that simulation tools utilize models with reasonable length scales and capture both the localized heat transfer and the core-scale heat transfer at the same time. To meet such analysis needs, different methodologies were developed. In conclusion, this includes adopting existing methods and further developing/improving them, as well as proposing innovative methods that leverage advanced computational frameworks such as the Multiphysics Object Oriented Simulation Environment (MOOSE).

HTGR↗

Development of a process for high capacity arc heater production of silicon for solar arrays

A high temperature silicon production process using existing electric arc heater technology is discussed. Silicon tetrachloride and a reductant, liquid sodium, were injected into an arc heated mixture of hydrogen and argon. Under these high temperature conditions, a very rapid reaction occurred, yielding silicon and gaseous sodium chloride. Techniques for high temperature separation and collection of the molten silicon were developed. The desired degree of separation was not achieved. The electrical, control and instrumentation, cooling water, gas, SiCl4, and sodium systems are discussed. The plasma reactor, silicon collection, effluent disposal, the gas burnoff stack, and decontamination and safety are also discussed. Procedure manuals, shakedown testing, data acquisition and analysis, product characterization, disassembly and decontamination, and component evaluation are reviewed.

Meyer, T. N.↗

Solar-pumped electronic-to-vibrational energy transfer lasers

The possibility of using solar-pumped lasers as solar energy converters is examined. The absorbing media considered are halogens or halogen compounds, which are dissociated to yield excited atoms, which then hand over energy to a molecular lasing medium. Estimates of the temperature effects for a Br2-CO2-He system with He as the cooling gas are given. High temperatures can cause the lower energy levels of the CO2 laser transition to be filled. The inverted populations are calculated and lasing should be possible. However, the efficiency is less than 0.001. Examination of other halogen-molecular lasant combinations (where the rate coefficients are known) indicate efficiencies in all cases of less than 0.005.

Harries, W. L.↗

IGCC performance comparison for variations in gasifier type and gas turbine firing temperature

Performance estimates were made for a series of integrated coal gasification combined cycle (IGCC) power systems using three generic types of coal gasification subsystems. The objectives of this study were (1) to provide a self consistent comparison of IGCC systems using different types of gasifiers and different oxidants and (2) to use this framework of cases to evaluate the effect of a gas turbine firing temperature and cooling approach an overall system efficiency. The basic IGCC systems considered included both air and oxygen blown versions of a fluidized bed gasifier, represented by the Westinghouse design, and an entrained bed gasifier, represented by the Texaco design. Also considered were systems using an oxygen blown, fixed bed gasifier, represented by the British Gas Corporation (BGC) slagging gasifier. All of these gasifiers were integrated with a combined cycle using a gas turbine firing temperature of 1700 K (2600 F) and a compressor pressure ratio of 16:1. Steam turbine throttle conditions were chosen to be 16.6 MPa/811 K (2400 psia/1000 F) with a single reheat to 810 K (1000 F). Some of these cases were modified to allow the evaluation of the effect of gas turbine firing temperature. Turbine firing temperatures from state of the art 1365 K (2000 F) to an advanced technology 1920 K (3000 F) were analyzed. A turbine cooling technology that maintains metal temperatures below acceptable limits was assumed for each level of firing temperature. System performance comparisons were made using three advanced turbine cooling technologies for the 1920 K (3000 F) firing temperature. The results indicate that the IGCC using the BGC gasifier had the highest net system efficiency (42.1 percent) of the five gasification cases considered.

Stochl, R. J.↗

Development and Validation of a Probabilistic Risk Assessment Model for a Generic Modular High Temperature Gas-Cooled Reactor

This study looks to develop and validate a probabilistic risk assessment (PRA) model for the modular high temperature gas-cooled reactor (MHTGR) using INL’s Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) software. Validation against a General Atomics design involves matching event and fault trees to historical frequencies, with a goal of under 15% difference. The research aims to deliver a reliable PRA model to assess the safety of MHTGRs for use within high-temperature industrial applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

Nuclear energy is increasingly acknowledged as pivotal in the global shift towards cleaner energy solutions. Advanced nuclear technologies, including High Temperature Gas-cooled Reactors (HTGRs), stand out as appealing options among Generation IV reactors due to their high temperature heat output and potential for cogeneration. HTGR designs incorporate passive safety systems, such as the Reactor Cavity Cooling System (RCCS), which utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. Regulatory bodies require thorough validation of safety systems like the RCCS to ensure they meet specified standards. Consequently, there is a pressing need within the industry for advanced simulation tools capable of assessing these systems’ performance accurately. There is a knowladge gap in the literature concerning high-fidelity data for the RCCS, which motivates the focus of this study. This research focuses on a specific RCCS designed for the Modular High-Temperature Gas Reactor developed by General Atomics (GA- MHTGR). Experimental studies on a scaled version of the air-cooled RCCS of GA-MHTGR were conducted by the University of Wisconsin-Madison. This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments. As first step we performed high fidelity simulations of the experimental facility setup, to analyze flow physics in such systems and validate NekRS and the MOOSE heat transfer and radiation modules.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗