Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLOVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft s swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First AIAA CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

Bui, Trong↗

Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

Bui, Trong T.↗

Analysis of Low Speed Stall Aerodynamics of a Swept Wing with Laminar Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

computational fluid dynamics↗

Development and Test of Robotically Assisted Extravehicular Activity Gloves

Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

Rogers, Jonathan M.↗

The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

The three-layered, pressurized space suit glove worn by Extravehicular Activity (EVA) crew members during missions commonly causes hand and forearm fatigue. The Spacesuit RoboGlove (SSRG), a Phase VI EVA space suit glove modified with robotic grasp-assist capabilities, has been developed to augment grip strength in order to improve endurance and reduce the risk of injury in astronauts. The overall goals of this study were to i) quantify the neuromuscular modulations that occur in response to wearing a conventional Phase VI space suit glove (SSG) during a fatiguing task, and ii) determine the efficacy of Spacesuit RoboGlove (SSRG) in reversing the adverse neuromuscular modulations and restoring altered muscular activity to barehanded levels. Six subjects performed a fatigue sequence consisting of repetitive dynamic-gripping interspersed with isometric grip-holds under three conditions: barehanded, wearing pressurized SSG, and wearing pressurized SSRG. Surface electromyography (sEMG) from six forearm muscles (flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor digitorum (ED), extensor carpi radialis longus (ECRL), and extensor carpi ulnaris (ECU)) and subjective fatigue ratings were collected during each condition. Trends in amplitude and spectral distributions of the sEMG signals were used to derive metrics quantifying neuromuscular effort and fatigue that were compared across the glove conditions. Results showed that by augmenting finger flexion, the SSRG successfully reduced the neuromuscular effort needed to close the fingers of the space suit glove in more than half of subjects during two types of tasks. However, the SSRG required more neuromuscular effort to extend the fingers compared to a conventional SSG in many subjects. Psychologically, the SSRG aided subjects in feeling less fatigued during short periods of intense work compared to the SSG. The results of this study reveal the promise of the SSRG as a grasp-assist device that can improve astronaut performance and reduce the risk of injury by offsetting neuromuscular effort. Modifications to the experimental protocol are needed, however, to improve the outcome of the neuromuscular fatigue metrics and determine the effectiveness of SSRG in increasing astronaut endurance. Nevertheless, these findings will improve the understanding of astronaut-spacesuit interaction and provide direction toward designing improved spacesuit gloves and robotic-assist devices, like the SSRG.

Madden, Kaci E.↗

Dynamic Mechanical Analysis Characterization of Glovebox Gloves

As part of the characterization of various glovebox glove material from four vendors, the permeability of gas through each type as a function of temperature was determined and a discontinuity in the permeability with temperature was revealed. A series of tests to determine the viscoelastic properties of the glove materials as a function of temperature using Dynamic Mechanical Analysis (DMA) was initiated. The glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐16°C Hypalon®, ‐ 16°C for Viton®, and ‐24°C for polyurethane‐Hypalon®. The glass transition was too complex for the butyl‐Hypalon® and butyl‐Viton® composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.

36 MATERIALS SCIENCE↗

Decrease the Number of Glovebox Glove Breaches and Failures

Los Alamos National Laboratory (LANL) is committed to the protection of the workers, public, and environment while performing work and uses gloveboxes as engineered controls to protect workers from exposure to hazardous materials while performing plutonium operations. Glovebox gloves are a weak link in the engineered controls and are a major cause of radiation contamination events which can result in potential worker exposure and localized contamination making operational areas off-limits and putting programmatic work on hold. Each day of lost opportunity at Technical Area (TA) 55, Plutonium Facility (PF) 4 is estimated at $1.36 million. Between July 2011 and June 2013, TA-55-PF-4 had 65 glovebox glove breaches and failures with an average of 2.7 per month. The glovebox work follows the five step safety process promoted at LANL with a decision diamond interjected for whether or not a glove breach or failure event occurred in the course of performing glovebox work. In the event that no glove breach or failure is detected, there is an additional decision for whether or not contamination is detected. In the event that contamination is detected, the possibility for a glove breach or failure event is revisited.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut

Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.

GRASPING↗

Retrofit of an Engineered Glove-port to a Los Alamos National Laboratory's Plutonium Facility Glovebox

At the Los Alamos National Laboratory's Plutonium Facility (TA-55), various isotopes of plutonium along with other actinides are routinely handled such that the spread of radiological contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox coupled with adequate negativity providing primary confinement). The current technique for changing glovebox gloves are the weakest part of this engineering control. 1300 pairs of gloves are replaced each year at TA-55, generating approximately 500 m{sup 3}/yr of transuranic (TRU) waste and Low Level Waste (LLW) waste that represents an annual disposal cost of about 4 million dollars. By retrofitting the LANL 8'' glove-port ring, a modern 'Push-Through' technology is utilized. This 'Push-Through' technology allows relatively fast glove changes to be done by operators with much less training and experience and without breaching containment. A dramatic reduction in waste is realized; exposure of the worker to residual contamination reduced, and the number of breaches due to installation issues is eliminated. In the following presentation, the evolution of the 'Push- Through' technology, the features of the glove-port retrofit, and waste savings are discussed. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soft Robotic Glove System for Wearable Haptic Teleoperation - 18373

Managing nuclear waste is a difficult, dangerous, and costly task. Teleoperation of robotic operators is an important functionality for this application, allowing robotic devices to operate in dangerous environments while still leveraging the existing abilities and technical knowledge of human workers. One difficulty in implementing effective teleoperation systems is that human operators rely on more senses beside sight: in particular, touch. The sense of touch could provide significant benefits for teleoperation, preventing environmental mishaps that could cost millions of dollars. To help remedy this problem, we present a soft haptic feedback glove system. The primary functionality of this system is to provide tactile and force feedback on the user's hands. This was achieved using custom cylindrical pneumatic actuators. These actuators consist of plastic sheeting folded into a hollow-walled cylinder which is connected to a pressure source. When pressurized, the cylinder walls expand and the cylinder straightens, with the force being related to the pressure. The glove system has one of these actuators over each of the user's three main fingers (index, middle, and thumb), where pressurizing the actuator applies a reaction force to the finger of the user, mimicking the resistance of a grasped object. The expansion of these actuators also causes them to physically press against the user's fingers, giving them the feeling of contact. To demonstrate the usability of this system, we implemented a virtual environment in V-REP simulating the interactions between a robotic Jaco Arm and a floating ball. This simulation receives hand and figure positions from the haptic glove and used them to drive the state of the simulated Jaco Arm. In response to the interactions between the Jaco and the floating ball, the simulation returns commands to the glove, instructing it to pressurize or depressurize its actuators as appropriate, allowing the user to feel the ball in their hand. We tested users in their ability to prevent the ball from floating away using this system with and without the haptic feedback. Results show that the addition of haptic feedback significantly improved the ability of users to interact precisely with the environment. We also used the finger positions of the haptic glove to control a physical robotic hand, and demonstrated the system's usability for control of real robots, though the lack of sensors on the robot made providing the tactile feedback impractical. However, there is more to grasping and holding an object than just the feeling of contact and the resistance to closing one's hand. The weight of the object will apply forces to the user's other joints as they hold it. To this end, we added a haptic feedback device for the user's wrist, a technique that can be generalized to the user's other joints. This is made up of reverse Pneumatic Artificial Muscles (rPAMs) stretching across the wrist between mounts on the hand and forearm. These rPAM actuators are tubes of silicone wrapped in thread such that they extend when pressurized. This extension can apply torque on the user's wrist, mimicking the feeling of gravity, or allowing the simulation of additional contact forces (such as the user's hand impacting an object). We tested this wrist device independently using a simulated path-following experiment. Users showed a significant improvement in performance when aided by haptic feedback during sinusoidal path experiments, demonstrating the usability of this approach. We then integrated the two systems, further demonstrating the usability of this approach. This project represents the first step towards a more effective robotic teleoperation system, allowing skilled human workers to perform tasks more effectively while remaining out of danger. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and adaptation of a novel supercritical extraction facility for operation in a glove box for recovery of radioactive elements

The design and development of a novel supercritical extraction experimental facility adapted for safe operation in a glove box for the recovery of radioactive elements from waste is described. The apparatus incorporates a high pressure extraction vessel, reciprocating pumps for delivering supercritical fluid and reagent, a back pressure regulator, and a collection chamber. All these components of the system have been specially designed for glove box adaptation and made modular to facilitate their replacement. Confinement of these materials must be ensured in a glove box to protect the operator and prevent contamination to the work area. Since handling of radioactive materials under high pressure (30 MPa) and temperature (up to 333 K) is involved in this process, the apparatus needs elaborate safety features in the design of the equipment, as well as modification of a standard glove box to accommodate the system. As a special safety feature to contain accidental leakage of carbon dioxide from the extraction vessel, a safety vessel has been specially designed and placed inside the glove box. The extraction vessel was enclosed in the safety vessel. The safety vessel was also incorporated with pressure sensing and controlling device.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Gloves for Firefighters

New firefighter's gloves are more flexible and comfortable than previous designs. Since some firefighters prefer gloves made of composite materials while others prefer dip-coated gloves, both types were developed. New gloves also find uses in foundries, steelmills, and other plants where they are substituted for asbestos gloves.

Tschirch, R. P.↗

Constructing Gloved wings for aerodynamic studies

Recently, two aircraft from the Dryden Flight Research Facility were used in the general study of natural laminar flow (NLF). The first, an F-14A aircraft on short-term loan from the Navy, was used to investigate transonic natural laminar flow. The second, an F-15A aircraft on long-term loan from the Air Force, was used to examine supersonic NLF. These tests were follow-on experiments to the NASA F-111 NLF experiment conducted in 1979. Both wings of the F-14A were gloved, in a two-phased experiment, with full-span(upper surface only) airfoil shapes constructed primarily of fiberglass, foam, and resin. A small section of the F-15A right wing was gloved in a similar manner. Each glove incorporated provisions for instrumentation to measure surface pressure distributions. The F-14A gloves also had provisions for instrumentation to measure boundary layer profiles, acoustic environments, and surface pitot pressures. Discussions of the techniques used to construct the gloves and to incorporate the required instrumentation are presented.

Bohn-Meyer, Marta R.↗

Design and test of an NLF wing glove for the variable-sweep transition flight experiment

Gloves for M = 0.7 and 0.8 design points were computationally designed and analyzed at conditions over the proposed flight test envelope. The resulting computational pressure distributions were analyzed in a boundary layer stability code. These results indicate that the available pressure distributions offer a wide range of combinations of cross flow and Tollmien-Schlichting N-factors. The glove designs along with the baseline configuration were tested in an entry into the National Transonic Facility. Analysis of the force and moment data showed no significant differences in the performance and stability and control characteristics between the baseline and gloved configurations. The rolling moment constraint was met over the entire flight test envelope for the gloved configuration. Pressure distributions for the NTF test confirmed the design pressure distributions were achieved. However, it was decided that with minor modifications to the inboard region of the glove, useful available data could be significantly increased by adding another row of pressure orifices at span station 167.

Waggoner, Ed G.↗

Development of a test protocol for evaluating EVA glove performance

Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.

Hinman, Elaine M.↗

Power assist EVA glove development

The design of the EVA glove is examined, emphasizing the development of a more flexible metacarpophalangeal (MCP) joint for the EVA glove. The analysis of the EVA glove MCP joint is reviewed and the glove design process is recapitulated. Experimental tests of the glove are summarized.

Main, John A.↗

The Astronaut Glove Challenge: Big Innovation from a (Very) Small Team

Many measurements were taken by test engineers from Hamilton Sundstrand, the prime contractor for the current EVA suit. Because the raw measurements needed to be converted to torques and combined into a final score, it was impossible to keep track of who was ahead in this phase. The final comfort and dexterity test was performed in a depressurized glove box to simulate real on-orbit conditions. Each competitor was required to exercise the glove through a defined set of finger, thumb, and wrist motions without any sign of abrasion or bruising of the competitor's hand. I learned a lot about arm fatigue! This was a pass-fail event, and both of the remaining competitors came through intact. After taking what seemed like an eternity to tally the final scores, the judges announced that I had won the competition. My glove was the only one to have achieved lower finger-bending torques than the Phase VI glove. Looking back, I see three sources of the success of this project that I believe also operate in other programs where small teams have broken new ground in aerospace technologies. These are awareness, failure, and trust. By remaining aware of the big picture, continuously asking myself, "Am I converging on a solution?" and "Am I converging fast enough?" I was able to see that my original design was not going to succeed, leading to the decision to start over. I was also aware that, had I lingered over this choice or taken time to analyze it, I would not have been ready on the first day of competition. Failure forced me to look outside conventional thinking and opened the door to innovation. Choosing to make incremental failures enabled me to rapidly climb the learning curve. Trusting my "gut" feelings-which are really an internalized accumulation of experiences-and my newly acquired skills allowed me to devise new technologies rapidly and complete both gloves just in time. Awareness, failure, and trust are intertwined: failure provides experiences that inform awareness and provide decision-making opportunities that build trust among team members and managers while opening minds to new pathways for development. All three are necessary for teams-large or small-to achieve big innovation.

Homer, Peter↗