Search NASA⌕ Search

SEARCH · Search NASA

Results for “GONDOLA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Stratospheric species measurements with tunable diode laser absorption spectroscopy

A balloon-borne instrument for stratospheric research has been developed with the capability to simultaneously measure several chemically related species in situ, for a full diurnal cycle. The instrument utilizes tunable infrared diode lasers (TDLs) to provide the radiation in selected wavelength regions for sensitive absorption spectroscopy over a one-km round-trip path. The TDL radiation is directed to a remote retroreflector which is lowered 500 m below the instrument gondola. A HeNe laser and co-aligned TV camera with CID imaging are used for retroreflector tracking. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species: NO, NO2, O3, and H2O. The number of operating TDLs can be expanded to four, resulting in the possibility of measuring several additional trace species.

Menzies, R. T.↗

A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

Vallerga, J. V.↗

Photometric and spectroscopic gamma-ray observations of solar transient phenomena using long duration balloons

A program currently in progress to conduct extended duration spectroscopic and photometric observation of solar X-ray phenomena from balloons is described. High photometric sensitivity to weak hard X-ray bursts is attained using a 600 sq cm array of phoswich scintillators. High spectral resolution for stronger bursts is available from an array of planar germanium detectors. These instruments are carried in a novel balloon gondola dssigned for the 15 to 20 day float durations available through using conventional zero pressure balloons in the radiation controlled (RACOON) mode.

Pelling, M. R.↗

Microprocessor-controlled laser tracker for atmospheric sensing

An optical tracking system comprising a visible HeNe laser, an imaging detector, and a microprocessor-controlled mirror, has been designed to track a moving retroreflector located up to 500 m away from an atmospheric instrument and simultaneously direct spectrally tunable infrared laser radiation to the retroreflector for double-ended, long-path absorption measurements of atmospheric species. The tracker has been tested during the recent flight of a balloon-borne tunable diode laser absorption spectrometer which monitors the concentrations of stratospheric species within a volume defined by a 0.14-m-diameter retroreflector lowered 500 m below the instrument gondola.

Johnson, R. A.↗

Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy

This is the second Semiannual Report submitted under Grant NAGW-509 for the development of a Balloon-Borne Three-Meter Telescope for Far-Infrared and Submillimeter Astronomy. It covers the period 1 March 1984 through 31 August 1984. This grant covers work at the Smithsonian Astrophysical Observatory (SAO), University of Arizona (UA) and the University of Chicago (UC). SAO is responsible for program management, the gondola structure including the attitude control and aspect systems, mechanical systems, and telemetry and command systems; the UA is responsible for optics design and fabrication; the UC is responsible for determining provisions for focal-plane instrumentation. SAO and the UA share responsibility for the ground support data and control computer.

Fazio, G. G.↗

The Venus Balloon Project

On June 11 and 15, 1985, two instrumental balloons were released from the Soviet VEGA 1 and VEGA 2 spacecraft and deployed in the atmosphere of Venus. The VEGA probes flew by the planet on their way to a rendezvous with comet Halley in March 1986. Drifting with the wind at altitudes of 54 km, the balloons traveled one-third of the way around the planet during their 46-hour lifetimes. Sensors on-board the gondolas made periodic measurements of pressure, temperature, vertical wind velocity, cloud particle density, ambient light level, and frequency of lightning. The data were transmitted to Earth and received at the Deep Space Network (DSN) 64-m stations and at several large antennas in the USSR. Approximately 95 percent of the telemetry data were successfully decoded at the DSN complexes and in the Soviet Union, and were provided to the international science team for analysis. Very Long Baseline Interferometry (VLBI) data were acquired by 20 radio observatories around the world for the purpose of monitoring the Venus winds. The DSN 64-m subnet was part of a 15-station VLBI network organized by the Centre National d'Etudes Spatiales (CNES) of France. In addition, five antennas of the Soviet network participated. VLBI data from the CNES network are currently being processed at the Jet Propulsion Laboratory.

Stelzried, C. T.↗

The energetic X-ray imaging telescope experiment (EXITE)

A new position-sensitive scintillation detector (NaI(Tl)), coded mask, and precision pointing system (resolution less than 1 arcmin) are being developed for balloon-borne imaging and spectral studies of cosmic X-ray sources in the 20-300 keV band. The scientific objectives of EXITE, as well as the general design of the detector, telescope and balloon gondola systems are presented.

Grindlay, J. E.↗

VEGA balloon system and instrumentation

The VEGA Venus balloon radio transmissions received on earth were used to measure the motion of the balloons and to obtain the data recorded by onboard sensors measuring atmospheric characteristics. Thus the balloons themselves, the gondolas, the onboard sensors, and the radio transmission system were all components of the experiment. A description of these elements is given, and a few details of data sampling and formatting are discussed.

Kremnev, R. S.↗

In situ stratospheric ozone measurements by long path UV absorption - Developments and interpretation

A high-sensitivity, in situ UV absorption ozone sensor has been developed for use in the stratosphere. The instrument couples 254-nm radiation from a low-pressure mercury discharge lamp into a 40-pass White cell to attain a high-sensitivity ozone absorption measurement. Preflight/postflight laboratory tests utilizing an ozone source coupled to a laboratory UV ozone photometer in a fast-flow system as well as in-flight diagnostics verify the successful operation of the instrument. Evidence is presented to verify that in situ UV absorption ozone photometers can measure stratospheric ozone with better than 3 percent precision and 5 percent accuracy, provided proper attention is given to both the thermal field surrounding the gondola and the ambient pressure measurements. Ozone data are compared with modeled profiles in the 28- to 40-km region. An assessment of the disagreement between observations and modeled profiles is given along with suggestions for future experiments designed to constrain photochemical models.

Weinstock, E. M.↗

Balloon-borne 3-meter telescope for far-infrared and submillimeter astronomy

The gimbal design was studied and revised to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball-bearings to replace the flex-pivot was defined and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared. Mirror development and the test program using mirror test blanks from Dornier were continued.

Fazio, G. G.↗

Cosmic ray detectors

Work on the MSFC emulsion laboratory microscopes in which mechanical modifications previously made were verified is reviewed, as is a design study of a large area hybrid electronic/emulsion chamber balloon flight detector system. This design is built upon the experience obtained with the highly successful MSFC/UAH hybrid instrument flown by the JACEE consortium. The design included overall system design and specification, design and fabrication of a prototype large light diffusion for Cerenkov charge detector or scintillator, design of a multiwire proportional counter array and design of the gondola or flight support system.

Gregory, John C.↗

Performance of a single-axis platform for balloon-borne remote sensing

The balloon flight performance of the Mark I single-axis platform and telescope is presented. Three performance indicators are examined: inclinometer output, gyro output, and infrared detector signal. The gondola itself experiences periodic angular disturbances with maximum amplitudes in the 0.1-2.0 deg range, with peaks occurring at periods of about 1, 2, 7, 20, and 250 s. The 2- and 20-s oscillations are identified with simple and compound pendulum motions, while the 250-s oscillations are speculated to be caused by atmospheric waves. The system meets the basic goal of providing a stable pointing direction within an uncertainty which is much less than the 0.3 deg telescope beam diameter.

Traub, W. A.↗

Future plans for the NASA suborbital program

The development of more reliable heavy-lift balloons and a fine pointed gondola; the development of the Black Brant-12 rocket for auroral research; and the development of a collaborative Orbiting Payload Using Scout program are outlined. Through 1989 NASA will conduct a comprehensive program of aircraft, balloon, and rocket campaigns in conjunction with Shuttle and satellite measurements on the Supernovae 1987a.

Shawhan, S. D.↗

Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy

The study and revision of the gimbal design of the Three-Meter Balloon Borne Telescope (TMBBT) is discussed. Efforts were made to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball bearings to replace the flex-pivots was designed and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared.

Fazio, Giovanni G.↗

SAGE II aerosol extinction and scattering data from balloon-borne photography

Earth limb radiance and extinction near sunset have been observed from a balloon-borne gondola nearly simultaneously and on air masses close to those probed by the SAGE II instrumentation on April 22, 1985. The results show the importance of accuracy of the altitude determination on the aerosol measurements. They indicate an important altitude dependence of the stratospheric aerosol granulometry in agreement with SAGE II results.

Ackerman, M.↗

Measurement of stratospheric trace constituent distributions from balloon-borne far infrared observations

FIR limb thermal emission spectra obtained from balloon-borne measurements made as a part of the Balloon Intercomparison Campaign (BIC) have been analyzed for retrieval of stratospheric trace-constituent distributions. The measurements were made with a high-resolution Michelson interferometer and covered the 15-180/cm spectral range with an unapodized spectral resolution of 0.0033/cm. The retrieved vertical profiles of O3, H2O, HDO, HCN, CO, and isotopes of O3 are presented. The results are compared with the BIC measurements for O3 and H2O made from the same balloon gondola and with other published data. A comparison of the simultaneously retrieved profiles for several gases with the published data shows good agreement and indicates the validity of the FIR data and retrieval techniques and the accuracy of the inferred profiles.

Abbas, M. M.↗

Meteorological variations in the middle clouds of Venus from Vega balloon in situ measurements

Instruments aboard the gondolas of the two Vega balloons obtained in situ measurements of pressure, temperature, vertical velocity relative to the balloon, cloud particle backscatter, lightning and the ambient light level. Atmospheric motions at the balloon float altitudes were also determined from earth-based tracking results. To illustrate the history of the balloon flights and to facilitate comparisons between some of the different observed quantities, measurements of pressure, temperature and backscatter are presented as time series for the entire lifetime of each balloon. Both long and short period variations have been detected. In addition, the environmental entropy encountered by each balloon will be discussed.

Elson, Lee S.↗

In-situ detection of OH in the lower stratosphere with a balloon borne high repetition rate laser system

Midday stratospheric OH density measurements have been carried out within the altitude interval of 31 to 24 km using the laser-induced fluorescence technique deployed on a balloon-borne gondola launched from Palestine, Texas on July 15, 1987. Laser output at 282 nm is produced with a pulsed, 17 kHz repetition rate, copper vapor laser pumped tunable dye laser. The OH mixing ratio ranged from 16 + or - 5 ppt at 31 km to 4 + or - 3 ppt in the 27 to 24 km region. Simultaneous ozone and water vapor measurements were also obtained with separate instruments.

Stimpfle, R. M.↗