At least 91 records · Page 5

Hotspot or Heatwave? Getting to Grips with Neutron Star Burst Oscillations

Many accreting neutron stars, including two of the millisecond pulsars, exhibit high frequency oscillations during Type I X-ray bursts. The properties of the burst oscillations reflect the nature of the thermal asymmetry on the stellar surface. The mechanism that gives rise to the aspzetry, however , remains unclear: possibilities include a hotspot due to uneven fuel distribution, modes of oscillation in the surface layers of the neutron star, or vortices driven by the Coriolis force. I will review some of the latest theory and observations, and present the results of a recent study of variability in the burst oscillations of the millisecond pulsar 51814-338.

Watts, A.↗

Integration of a computerized two-finger gripper for robot workstation safety

A microprocessor-based controller has been developed that continuously monitors and adjusts the gripping force applied by a special two-finger gripper. This computerized force sensing gripper system enables the endeffector gripping action to be independently detected and corrected. The gripping force applied to a manipulated object is real-time monitored for problem situations, situations which can occur during both planned and errant robot arm manipulation. When unspecified force conditions occur at the gripper, the gripping force controller initiates specific reactions to cause dynamic corrections to the continuously variable gripping action. The force controller for this intelligent gripper has been interfaced to the controller of an industrial robot. The gripper and robot controllers communicate to accomplish the successful completion of normal gripper operations as well as unexpected hazardous situations. An example of an unexpected gripping condition would be the sudden deformation of the object being manipulated by the robot. The capabilities of the interfaced gripper-robot system to apply workstation safety measures (e.g., stop the robot) when these unexpected gripping effects occur have been assessed.

Sneckenberger, John E.↗

Some important aspects in testing high-modulus fiber composite tubes designed for multiaxial loading

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0 deg, + or - 45 deg, and 90 deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high strength, high modulus fiber composite tubes.

Sullivan, T. L.↗

Some important aspects in testing high-modulus fiber composite tubes designed for multiaxial loading.

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0, 45, plus or minus 45, and 90 deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

Sullivan, T. L.↗

Some important aspects in testing high-modulus fiber composite tubes in axial tension.

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation, and strain variations along the tube length and circumference. The investigation was limited to loading graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

Sullivan, T. L.↗

Handgrip and general muscular strength and endurance during prolonged bedrest with isometric and isotonic leg exercise training

Measurements of maximal grip strength and endurance at 40 percent max strength were obtained for 7 men 19-21 years of age, 1-2 days before and on the first recovery day during three 2-week bedrest (BR) periods, each separated by a 3-week ambulatory recovery period. The subjects performed isometric exercise (IME) for 1 hr/day, isotonic exercise (ITE) for 1 hr/day, and no exercise (NOE) in the three BR periods. It was found that the mean maximal grip strength was unchanged after all three BR periods. Mean grip endurance was found to be unchanged after IME and ITE training, but was significantly reduced after NOE. These results indicate that IME and ITE training during BR do not increase or decrease maximal grip strength, alghough they prevent loss of grip endurance, while the maximal strength of all other major muscle groups decreases in proportion to the length of BR to 70 days. The maximal strength reduction of the large muscle groups was found to be about twice that of the small muscle groups during BR. In addition, it is shown that changes in maximal strength after spaceflight, BR, or water immersion deconditioning cannot be predicted from changes in submaximal or maximal oxygen uptake values.

Greenleaf, J. E.↗

Flexible Electrostatic Technology for Capture and Handling Project

To NASA unfunded & planned missions: This new capability to sense proximity, flexibly align to, and attractively grip and capture practically any object in space without any pre-designed physical features or added sensors or actuators will enable or enhance many of MSFC's strategic emphasis areas in space transportation, and space systems such as: 1. A Flexible Electrostatic gripper can enable the capture, gripping and releasing of an extraterrestrial sample of different minerals or a sample canister (metallic or composite) without requiring a handle or grapple fixture.(B) 2. Flexible self-aligning in-space capture/soft docking or berthing of ISS resupply vehicles, pressurized modules, or nodes for in-space assembly and shielding, radiator, and solar Array deployment for space habitats (C) 3. The flexible electrostatic gripper when combined with a simple steerable extendible boom can grip, position, and release objects of various shapes and materials with low mass and power without any prior handles or physical accommodations or surface contamination for ISS experiment experiments and in-situ repair.(F)(G) 4. The Dexterous Docking concept previously proposed to allow simple commercial resupply ships to station-keep and capture either ISS or an Exploration vehicle for supply or fluid transfer lacked a self-sensing, compliant, soft capture gripper like FETCH that could retract and attach to a CBM. (I) 5. To enable a soft capture and de-orbit of a piece of orbital debris will require self-aligning gripping and holding an object wherever possible (thermal coverings or shields of various materials, radiators, solar arrays, antenna dishes) with little or no residual power while adding either drag or active low level thrust.(K) 6. With the scalability of the FETCH technology, small satellites can be captured and handled or can incorporate FETCH gripper to dock to and handle other small vehicles and larger objects for de-orbiting or mitigating Orbital debris (L) 7. Many of previous MSFC and NASA proposals or concepts can now be realized or simplified by the development of the this initial and future FETCH grippers including commercial resupply, Exploration vehicle assembly, Satellite servicing, and orbital debris removal since a major part of these missions is to align to and capture some handle. Completed Project (2013 - 2014) Flexible Electrostatic Technology for Capture & Handling Project Center Innovation Fund: MSFC CIF Program | Space Technology Mission Directorate (STMD) For more information visit techport.nasa.gov Some NASA technology projects are smaller (for example SBIR/STTR, NIAC and Center Innovation Fund), and will have less content than other, larger projects. Newly created projects may not sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 pounds per square inch or 70-300 lb./sq. ft. of surface contact, the FETCH can turn-on and turn-off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, and precision relocation for accurate anchor adhesion.

Keys, Andrew↗

Solid state controller three axes controller

The reported flight controller features a handle grip which is mounted on a longitudinally extending control element. The handle grip is pivotally mounted on the control element about a pitch axis which is perpendicular to the longitudinal axis through the control element. The pivotal mounting includes a resilient force mounting mechanism which centers the grip relative to the control element. Rotation of the handle grip produces a direct rotation of a transducer element in a transducer which provides an electrical indication of the rotative movement about three mutually perpendicular axes.

Bailey, C. L., Jr.↗

Method and apparatus for slicing crystals

The crystal slicing method is described as follows. A crystal is sliced in a plane parallel to flat, opposed parallel end faces of the crystal. The end faces of the crystal are gripped by a pair of opposed, perforated platens of a pair of vacuum chambers, one of which is translatable relative to the other. A blade cuts the crystal through the desired plane. A spring biases one of the vacuum chambers away from the other vacuum chamber while both of the faces are gripped by the vacuum chambers and the blade is cleaving the crystal. A sliced portion of the crystal gripped by one of the vacuum chambers is pulled away from the remainder of the crystal gripped by the second vacuum chamber when the crystal was cleaved by the blade through the plane.

Benedicto, J. S. J.↗