Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A measurement of the absolute flux of cosmic-ray electrons

A balloon-borne superconducting magnet spectrometer was used to measure the absolute flux of cosmic-ray electrons. The instrument consisted of a gas Cerenkov detector, a momentum spectrometer, and a lead-scintillator shower counter. In order to determine electron flux in the interstellar medium, observed fluxes for energy loss in the atmosphere and the payload were corrected, taking into account solar modulation effects and bremsstrahlung energy losses. Fluxes were measured at an average atmospheric depth of 5.8 g/sq cm, and the solar modulation was 300 MeV. A cosmic-ray electron flux of 367 E to the exp(3.15 + or -0.2) per sq m/sr s GeV was obtained in the energy range 4.5-63.5 GeV. The uncertainty of the absolute (electron-positron) flux was 10 percent. A summary of the electron data is given in a table.

Golden, R. L.↗

Adjustable mount for electro-optic transducers in an evacuated cryogenic system

The invention is an adjustable mount for positioning an electro-optic transducer in an evacuated cryogenic environment. Electro-optic transducers are used in this manner as high sensitivity detectors of gas emission lines of spectroscopic analysis. The mount is made up of an adjusting mechanism and a transducer mount. The adjusting mechanism provided five degrees of freedom, linear adjustments and angular adjustments. The mount allows the use of an internal lens to focus energy on the transducer element thereby improving the efficiency of the detection device. Further, the transducer mount, although attached to the adjusting mechanism, is isolated thermally such that a cryogenic environment can be maintained at the transducer while the adjusting mechanism remains at room temperature. Radiation shields also are incorporated to further reduce heat flow to the transducer location.

Crossley, Edward A., Jr.↗

Rotational fluid flow experiment: WPI/MITRE advanced space design GASCAN 2

The design and implementation is examined of an electro-mechanical system for studying vortex behavior in a microgravity environment. Most of the existing equipment was revised and redesigned as necessary. Emphasis was placed on the documentation and integration of the mechanical and electrical subsystems. Project results include the reconfiguration and thorough testing of all the hardware subsystems, the implementation of an infrared gas entrainment detector, new signal processing circuitry for the ultrasonic fluid circulation device, improved prototype interface circuits, and software for overall control of experiment design operation.

Daly, Walter F.↗

Rotational fluid flow experiment

This project which began in 1986 as part of the Worcester Polytechnic Institute (WPI) Advanced Space Design Program focuses on the design and implementation of an electromechanical system for studying vortex behavior in a microgravity environment. Most of the existing equipment was revised and redesigned by this project team, as necessary. Emphasis was placed on documentation and integration of the electrical and mechanical subsystems. Project results include reconfiguration and thorough testing of all hardware subsystems, implementation of an infrared gas entrainment detector, new signal processing circuitry for the ultrasonic fluid circulation device, improved prototype interface circuits, and software for overall control of experiment operation.

Source record↗

SuperHERO: The Next Generation Hard X-ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Gaskin, Jessica A.↗

SuperHERO: The Next Generation Hard X-Ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Wilson-Hodge, Colleen A.↗

Performance of the PRAXyS X-Ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

PRAXyS↗

Design for Minimum Casualty Area – The IXPE Case

The Imaging X-Ray Polarimetry Explorer (IXPE) is a new international space observatory in NASA’s Small Explorer program, designed in a collaboration between the Italian Space Agency and NASA’s Marshall Space Flight Center, and built by Ball Aerospace. IXPE has an expected launch in November 2021, to a 600-km altitude equatorial orbit. IXPE is an astrophysics mission using three telescope assemblies to measure the polarization of cosmic X-rays. Each assembly is composed of a mirror module assembly (MMA) with 24 nested nickel-cobalt cylindrical shells and a unique, polarization-sensitive, gas pixel detector (GPD) within the detector unit (DU). As a NASA mission, IXPE must adhere to the orbital debris mitigation requirements specified in NASA Standard 8719.14 [1]; in the present work, we will only discuss reentry human casualty risk. As initially designed, the IXPE observatory exceeded NASA’s casualty risk threshold. IXPE does not include a propulsion system to perform a controlled reentry at the end of mission to mitigate the ground casualty risk. To reduce the risk from the uncontrolled reentry of this observatory, the IXPE design team worked with the NASA Orbital Debris Program Office to reduce the debris casualty area through design-for-demise and containment methods. The flight design of IXPE is now compliant with the ground casualty risk requirement at a casualty probability of 1:13,100 compared to a casualty requirement of better than 1:10,000.

C Ostrom↗

X-Ray Polarization of the Eastern Lobe of SS 433

IXPE is the first satellite mission dedicated to X-ray polarimetry in the 2–8 keV band. It contains three telescopes, each with a gas-pixel detector sensitive to linear X-ray polarization. IXPE enables imaging X-ray polarimetry of extended sources with an angular resolution of ~30ʺ over a 12ʹ diameter field of view.

x-ray polarimetry, black holes, jets↗

Next generation fire suppressants

Spectrex, Inc., located in Cedar Grove, NJ is a manufacturer of fire detection and suppression equipment. Spectrex is one of the original pioneers in high speed fire detection and suppression systems for combat vehicles. Spectrex has installed fire suppressions systems in thousands of combat vehicles and ships throughout the world. Additionally, they manufacture flame explosion detectors, ship damage control systems, and optical gas and vapor detectors. The culmination of several years of research and development has recently produced an innovative electro-optical continuous monitoring systems called SharpEye 20/20I IR(sup 3) and SAFEYE that provide fast and reliable gas, vapor, aerosol, flame, and explosion detection. SharpEye 20/20I IR(sup 3) is a self-contained triple spectrum flame detector which scans for oscillating IR radiation (1 to 10 Hz) in the spectral bands ranging from 4.0 to 5.0 microns and uses programmed algorithms to check the ratio and correlation of data received by the three sensors to make the system highly immune to false alarms. It is extremely sensitive as it can detect a 1 x 1 square foot gasoline pan fire at 200 feet in less than 3 seconds. The sensitivity is user programmable, offering 4 ranges of detection. SAFEYE is comprised of a selected number of multispectral ban microprocessors controlled detectors which are in communication with one or more radiation sources that is projected along a 600 feet optical path. The signals from the selected narrow bands are processed and analyzed by highly sophisticated algorithms. It is ideal for high risk, remote, large areas such as petroleum and chemical manufacturing sites, waste dumps, aircraft cargo bays, and ship compartments. The SAFEYE will perform direct readings of the presence or rate of rise of concentrations of gases, vapors, or aerosols at the range of parts per million and provide alarms at various set points at different levels of concentrations.

Brown, Jerry A.↗

Using dimethylether as a drift gas in a high precision drift tube detector

Excellent spatial resolution (34 microns) has been obtained using dimethylether, (CH3)2O at 1 atm in a small drift tube detector. This is better by at least a factor of 2 compared to previous work (about 80 microns) with a conventional gas (a 50-50 argon-ethane mixture) in the same detector. The Lorentz angle and the gas amplification have been measured over a wide range of electric and magnetic fields.

Zhou, B.↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

Carbon-Nanotube-Based Chemical Gas Sensor

Conventional thermal conductivity gauges (e.g. Pirani gauges) lend themselves to applications such as leak detectors, or in gas chromatographs for identifying various gas species. However, these conventional gauges are physically large, operate at high power, and have a slow response time. A single-walled carbon-nanotube (SWNT)-based chemical sensing gauge relies on differences in thermal conductance of the respective gases surrounding the CNT as it is voltage-biased, as a means for chemical identification. Such a sensor provides benefits of significantly reduced size and compactness, fast response time, low-power operation, and inexpensive manufacturing since it can be batch-fabricated using Si integrated-circuit (IC) process technology.

Kaul, Arunpama B.↗

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

The response of smoke detectors to pyrolysis and combustion products from aircraft interior materials

The following projects were completed as part of the effort to develop and test economically feasible fire-resistant materials for interior furnishings of aircraft as well as detectors of incipient fires in passenger and cargo compartments: (1) determination of the sensitivity of various contemporary gas and smoke detectors to pyrolysis and combustion products from materials commonly used in aircraft interiors and from materials that may be used in the future, (2) assessment of the environmental limitations to detector sensitivity and reliability. The tests were conducted on three groups of materials by exposure to the following three sources of exposure: radiant and Meeker burner flame, heated coil, and radiant source only. The first test series used radiant heat and flame exposures on easily obtainable test materials. Next, four materials were selected from the first group and exposed to an incandescent coil to provide the conditions for smoldering combustion. Finally, radiant heat exposures were used on advanced materials that are not readily available.

Mckee, R. G.↗

Methane Detector With Plastic Fresnel Lens

Laser detector for natural gas leaks modified by substitution of molded plastic lens for spherical mirror. By measuring relative attenuation at two wavelengths, detector used to check for methane escaping from pipelines above or below ground and from landfill.

Grant, W. B.↗