Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gauges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Magnetic Velocity Gauges: Effects of Misalignment

Embedded velocity gauges are standardly used at LANL on gas gun experiments of a shock to-detonation transition. The experiments are intended to be one-dimensional with a planar shock driven by the projectile from a gas gun propagating along the axis of the HE cylinder. As disussed by Gustavsen et al. [1999], the accuracy of the gauges depends on the alignment of the directions of shock propagation, magnetic field and the active gauge element. A source of inaccuracies is from tilt or misalignment angle at impact between the projectile surface and the HE surface; typically a few milliradians. This leads to the shock propagating at a slight angle to the axis of the HE cylinder and can affect the shock rise time of the velocity gauges, the time offset between the tracker gauges for the trajectory of the lead shock, and the gauge positions in the direction of propagation. It is important to note that tilt is characterized by 2 parameters; the magnitude of the angle relative to the HE axis and the direction in the plane transverse to the HE axis. Here we derive the uncertainties from tilt to leading order in the tilt angle.

42 ENGINEERING↗

Validation of Printed Strain Gauges at Moderate Temperatures (up to 300°C)

Strain gauges in material test reactors serve to generate critical mechanical property data for qualifying the performance of reactor components. Resistance based strain gauge technologies are both well established and commercially available; however, they present limitations in terms of reactor experiment conditions, especially in areas where physical space is a challenge. In this work, an additively manufactured capacitance-based strain gauge was printed on a stainless-steel specimen and tested at up to the prototypic pressurized-water reactor operating temperature of 300°C. In addition, a high-temperature resistive strain gauge (RSG) was used to better understand how the RSGs operate, and to provide baseline measurements for comparison against the printed strain gauges. Future development of printed strain gauges will focus on expanding their temperature limits to 500°C and enabling applications currently beyond the capabilities of commercial RSGs.

36 MATERIALS SCIENCE↗

Propellant Mass Gauging in Microgravity with Electrical Capacitance Tomography

Advancements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences space vehicle performance and mission assurance. Propellant mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not always work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various stages of development, most of them have major disadvantages. Electrical Capacitance Tomography (ECT) is a sensing technology that is able to reconstruct the liquid distribution inside of a tank, which can then be integrated to obtain mass. While ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA Kennedy Space Center Launch Services Program, with support from the Flight Opportunities Program, successfully tested an ECT liquid mass gauging system experiment on a parabolic flight aircraft in May 2022. Basics of ECT measurement theory, details of the experiment setup, data processing, ground test results, and the flight test result will be discussed. The results suggest that ECT sensor systems will be useful as a propellant mass gauging technology in both accelerated and microgravity environments.

electrical capacitance tomography↗

Self-duality under gauging a non-invertible symmetry

Abstract We discuss two-dimensional conformal field theories (CFTs) which are invariant under gauging a non-invertible global symmetry. At every point on the orbifold branch ofc= 1 CFTs, it is known that the theory is self-dual under gauging a ℤ 2 × ℤ 2 symmetry, and has Rep(H 8 ) and Rep(D 8 ) fusion category symmetries as a result. We find that gauging the entire Rep(H 8 ) fusion category symmetry maps the orbifold theory at radiusRto that at radius 2/R. AtR=$$ \sqrt{2} $$ 2 , which corresponds to two decoupled Ising CFTs (Ising 2 in short), the theory is self-dual under gauging the Rep(H 8 ) symmetry. This implies the existence of a topological defect line in the Ising 2 CFT obtained from half-space gauging of the Rep(H 8 ) symmetry, which commutes with thec= 1 Virasoro algebra but does not preserve the fully extended chiral algebra. We bootstrap its action on thec= 1 Virasoro primary operators, and find that there are no relevant or marginal operators preserving it. Mathematically, the new topological line combines with the Rep(H 8 ) symmetry to form a bigger fusion category which is a ℤ 2 -extension of Rep(H 8 ). We solve the pentagon equations including the additional topological line and find 8 solutions, where two of them are realized in the Ising 2 CFT. Finally, we show that the torus partition functions of the Monster 2 CFT and Ising×Monster CFT are also invariant under gauging the Rep(H 8 ) symmetry.

Physics↗

Light, long-lived B - L gauge and Higgs bosons at the DUNE near detector

The low-energy U(1)B-L gauge symmetry is well-motivated as part of beyond Standard Model physics related to neutrino mass generation. We show that a light B - L gauge boson Z' and the associated U(1) B-L -breaking scalar φ can both be effectively searched for at high-intensity facilities such as the near detector complex of the Deep Underground Neutrino Experiment (DUNE). Without the scalar φ, the Z' can be probed at DUNE up to mass of 1 GeV, with the corresponding gauge coupling g BL as low as 10 -9 . In the presence of the scalar φ with gauge coupling to Z', the DUNE capability of discovering the gauge boson Z' can be significantly improved, even by one order of magnitude in g BL , due to additional production from the decay φ → Z'Z'. The DUNE sensitivity is largely complementary to other long-lived Z' searches at beam-dump facilities such as FASER and SHiP, as well as astrophysical and cosmological probes. On the other hand, the prospects of detecting φ itself at DUNE are to some extent weakened in presence of Z', compared to the case without the gauge interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the canonical formulation of gauge field theories and Poincaré transformations

We address the Hamiltonian formulation of classical gauge field theories while putting forward results some of which are not entirely new, though they do not appear to be well known. We refer in particular to the fact that neither the canonical energy momentum vector ( P μ ) nor the gauge invariant energy momentum vector ( P inv μ ) do generate space-time translations of the gauge field by means of the Poisson brackets: In a general gauge, one has to consider the so-called kinematical energy momentum vector and, in a specific gauge (like the radiation gauge in electrodynamics), one has to consider the Dirac brackets rather than the Poisson brackets. Similar arguments apply to rotations and to Lorentz boosts and are of direct relevance to the “nucleon spin crisis” since the spin of the proton involves a contribution which is due to the angular momentum vector of gluons and thereby requires a proper treatment of the latter. We conclude with some comments on the relationships between the different approaches to quantization (canonical quantization based on the classical Hamiltonian formulation, Gupta-Bleuler, path integrals, BRST, covariant canonical approaches).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gauges, loops, and polynomials for partition functions of graphical models

Graphical models represent multivariate and generally not normalized probability distributions. Computing the normalization factor, called the partition function, is the main inference challenge relevant to multiple statistical and optimization applications. The problem is #P-hard that is of an exponential complexity with respect to the number of variables. Here, aimed at approximating the partition function, we consider multi-graph models where binary variables and multivariable factors are associated with edges and nodes, respectively, of an undirected multi-graph. We suggest a new methodology for analysis and computations that combines the Gauge function technique from Chertkov and Chernyak with the technique developed in Anari and Oveis Gharan 2017 arXiv:1702.02937; Gurvits 2011 arXiv:1106.2844; Straszak and Vishnoi 2017 55th Annual Allerton Conf. on Communication, Control, and Computing, based on the recent progress in the field of real stable polynomials. We show that the Gauge function, representing a single-out term in a finite sum expression for the partition function which achieves extremum at the so-called belief-propagation gauge, has a natural polynomial representation in terms of gauges/variables associated with edges of the multi-graph. Moreover, Gauge function can be used to recover the partition function through a sequence of transformations allowing appealing algebraic and graphical interpretations. Algebraically, one step in the sequence consists of the application of a differential operator over gauges associated with an edge. Graphically, the sequence is interpreted as a repetitive elimination/contraction of edges resulting in multi-graph models on decreasing in size (number of edges) graphs with the same partition function as in the original multi-graph model. Even though the complexity of computing factors in the sequence of the derived multi-graph models and respective Gauge functions grow exponentially with the number of eliminated edges, polynomials associated with the new factors remain bi-stable if the original factors have this property. Moreover, we show that BP estimations in the sequence do not decrease, each low-bounding the partition function.

97 MATHEMATICS AND COMPUTING↗

String membrane nets from higher-form gauging: An alternate route to 𝑝-string condensation

We present a new perspective on the $p$-string condensation procedure for constructing 3+1D fracton phases by implementing this process via the gauging of higher-form symmetries. Specifically, we show that gauging a 1-form symmetry in 3+1D that is generated by Abelian anyons in isotropic stacks of 2+1D topological orders naturally results in a 3+1D $p$-string condensed phase, providing a controlled non-perturbative construction that realizes fracton orders. This approach clarifies the symmetry principles underlying $p$-string condensation and generalizes the familiar connection between anyon condensation and one-form gauging in two spatial dimensions. We demonstrate this correspondence explicitly in both field theories and lattice models: in field theory, we derive the foliated field theory description of the $\mathbb{Z}_N$ X-Cube model by gauging a higher-form symmetry in stacks of 2+1D $\mathbb{Z}_N$ gauge theories; on the lattice, we show how gauging a diagonal 1-form symmetry in isotropic stacks of $G$-graded string-net models leads to string-membrane-nets hosting restricted mobility excitations. This perspective naturally generalizes to spatial dimensions $d \geq 2$ and provides a step towards building an algebraic theory of $p$-string condensation.

Anyons↗

General quantum algorithms for Hamiltonian simulation with applications to a non-Abelian lattice gauge theory

With a focus on universal quantum computing for quantum simulation, and through the example of lattice gauge theories, we introduce rather general quantum algorithms that can efficiently simulate certain classes of interactions consisting of correlated changes in multiple (bosonic and fermionic) quantum numbers with non-trivial functional coefficients. In particular, we analyze diagonalization of Hamiltonian terms using a singular-value decomposition technique, and discuss how the achieved diagonal unitaries in the digitized time-evolution operator can be implemented. The lattice gauge theory studied is the SU(2) gauge theory in 1+1 dimensions coupled to one flavor of staggered fermions, for which a complete quantum-resource analysis within different computational models is presented. The algorithms are shown to be applicable to higher-dimensional theories as well as to other Abelian and non-Abelian gauge theories. The example chosen further demonstrates the importance of adopting efficient theoretical formulations: it is shown that an explicitly gauge-invariant formulation using loop, string, and hadron degrees of freedom simplifies the algorithms and lowers the cost compared with the standard formulations based on angular-momentum as well as the Schwinger-boson degrees of freedom. The loop-string-hadron formulation further retains the non-Abelian gauge symmetry despite the inexactness of the digitized simulation, without the need for costly controlled operations. Such theoretical and algorithmic considerations are likely to be essential in quantumly simulating other complex theories of relevance to nature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Gauge Picture of Quantum Dynamics

Although local Hamiltonians exhibit local time dynamics, this locality is not explicit in the Schrödinger picture in the sense that the wavefunction amplitudes do not obey a local equation of motion. We show that geometric locality can be achieved explicitly in the equations of motion by "gauging" the global unitary invariance of quantum mechanics into a local gauge invariance. That is, expectation values $\langle \psi|A|\psi \rangle$ are invariant under a global unitary transformation acting on the wavefunction $|\psi\rangle \to U |\psi\rangle$ and operators $A \to U A U^\dagger$, and we show that it is possible to gauge this global invariance into a local gauge invariance. To do this, we replace the wavefunction with a collection of local wavefunctions $|\psi_J\rangle$, one for each patch of space $J$. The collection of spatial patches is chosen to cover the space; e.g. we could choose the patches to be single qubits or nearest-neighbor sites on a lattice. Local wavefunctions associated with neighboring pairs of spatial patches $I$ and $J$ are related to each other by dynamical unitary transformations $U_{IJ}$. The local wavefunctions are local in the sense that their dynamics are local. That is, the equations of motion for the local wavefunctions $|\psi_J\rangle$ and connections $U_{IJ}$ are explicitly local in space and only depend on nearby Hamiltonian terms. (The local wavefunctions are many-body wavefunctions and have the same Hilbert space dimension as the usual wavefunction.) We call this picture of quantum dynamics the gauge picture since it exhibits a local gauge invariance. The local dynamics of a single spatial patch is related to the interaction picture, where the interaction Hamiltonian consists of only nearby Hamiltonian terms. We can also generalize the explicit locality to include locality in local charge and energy densities.

Physics↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Investigation of the sensitivity of ionization-type vacuum gauges

A quantitative analysis of a large and representative sample of available data has been made to determine the best criteria for predicting the relative sensitivities of ionization-type vacuum gauges to different gases. The molecular property of the gas that correlates best with relative sensitivity is the ionization cross section (eV). For high-pressure ionization gauges, a cross section evaluated at 2/3 of the accelerating potential of the gauge is the best choice. For Bayard-Alpert and triode gauges, any of three choices are of approximately equal value. These are 100 eV cross section values, maximum cross section value for each gas, and a cross section evaluated at 2/3 of the accelerating potential for each gauge. For the Alphatron gauge, cross section values in the range 5000-10,000 eV provide the best correlation.

Holanda, R.↗

A comparative assessment of R. M. Young and tipping bucket rain gauges

Rain rates as derived from standard tipping bucket rain gauges have variable integration times corresponding to the interval between bucket tips. For example, the integration time for the Weathertronics rain gauge is given by delta(T) = 15.24/R (min), where R is the rain rate expressed in mm/h and delta(T) is the time between tips expressed in minutes. It is apparent that a rain rate of 1 mm/h has an integration time in excess of 15 minutes. Rain rates larger than 15.24 mm/h will have integration times smaller than 1 minute. The integration time is dictated by the time it takes to fill a small tipping bucket where each tip gives rise to 0.254 mm of rainfall. Hence, a uniform rain rate of 1 mm/h over a 15 minute period will give rise to the same rain rate as 0 mm/h rainfall over the first 14 minutes and 15 mm/h between 14 to 15 minutes from the reference tip. Hence, the rain intensity fluctuations may not be captured with the tipping bucket rain gauge for highly variable rates encompassing lower and higher values over a given integration time. The objective of this effort is to provide an assessment of the features of the R. M. Young capacitive gauge and to compare these features with those of the standard tipping bucket rain gauge. A number of rain rate-time series derived from measurements with approximately co-located gauges are examined.

Goldhirsh, Julius↗

Propellant Gauging for Exploration

This paper presents a brief overview of propellant gauging needs and requirements in the context of lunar exploration missions defined by the Exploration Systems Architecture Study (ESAS) report. A timeline for the development and testing of gauging technologies, and a few key design review dates are presented. A lunar exploration mission scenario is discussed which aids in defining the propellant gauging needs. The fleet of new exploration vehicles includes the Ares I and Ares V launch vehicles, Earth Departure Stage (EDS), Lunar Surface Access Module (LSAM) ascent and descent stages, and the Orion Crew Exploration Vehicle (CEV). The liquid propellant choices are currently oxygen - hydrogen for the launch vehicles, the EDS, and LSAM descent module; oxygen - methane for LSAM ascent module; and monomethylhydrazine nitrogen tetroxide (MMH-NTO) for the CEV. Estimated tank sizes, temperatures, pressures, and storage durations are presented. A baseline propellant gauging system is proposed that is based on high Technology Readiness Level (TRL) gauging technologies. In order to be considered for use on the new exploration vehicles, any new gauging technologies will have to show a clear benefit over the baseline methods in terms of performance and/or cost.

Zimmerli, Gregory A.↗

Evaluation of TRMM Ground-Validation Radar-Rain Errors Using Rain Gauge Measurements

Ground-validation (GV) radar-rain products are often utilized for validation of the Tropical Rainfall Measuring Mission (TRMM) spaced-based rain estimates, and hence, quantitative evaluation of the GV radar-rain product error characteristics is vital. This study uses quality-controlled gauge data to compare with TRMM GV radar rain rates in an effort to provide such error characteristics. The results show that significant differences of concurrent radar-gauge rain rates exist at various time scales ranging from 5 min to 1 day, despite lower overall long-term bias. However, the differences between the radar area-averaged rain rates and gauge point rain rates cannot be explained as due to radar error only. The error variance separation method is adapted to partition the variance of radar-gauge differences into the gauge area-point error variance and radar rain estimation error variance. The results provide relatively reliable quantitative uncertainty evaluation of TRMM GV radar rain estimates at various times scales, and are helpful to better understand the differences between measured radar and gauge rain rates. It is envisaged that this study will contribute to better utilization of GV radar rain products to validate versatile spaced-based rain estimates from TRMM, as well as the proposed Global Precipitation Measurement, and other satellites.

Wang, Jianxin↗

Distributed Disdrometer and Rain Gauge Measurement Infrastructure Developed for GPM Ground Validation

Global Precipitation Mission (GPM)retrieval algorithm validation requires datasets characterizing the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (FOV;<10 km). Collection of this data provides a means to assess retrieval errors related to beam filling and algorithm PSD assumptions. Hence, GPM Ground Validation is developing a deployable network of precipitation gauges and disdrometers to provide fine-scale measurements of PSD and precipitation accumulation variability. These observations will be combined with dual-frequency, polarimetric, and profiling radar data in a bootstrapping fashion to extend validated PSD measurements to a large coverage domain. Accordingly, a total of 24 Parsivel disdrometers(PD), 5 3rd-generation 2D Video Disdrometers (2DVD), 70 tipping bucket rain gauges (TBRG),9 weighing gauges, 7 Hot-Plate precipitation sensors (HP), and 3 Micro Rain Radars (MRR) have been procured. In liquid precipitation the suite of TBRG, PD and 2DVD instruments will quantify a broad spectrum of rain rate and PSD variability at sub-kilometer scales. In the envisioned network configuration 5 2DVDs will act as reference points for 16 collocated PD and TBRG measurements. We find that PD measurements provide similar measures of the rain PSD as observed with collocated 2DVDs (e.g., D0, Nw) for rain rates less than 15 mm/hr. For heavier rain rates we will rely on 2DVDs for PSD information. For snowfall we will combine point-redundant observations of SWER distributed over three or more locations within a FOV. Each location will contain at least one fenced weighing gauge, one HP, two PDs, and a 2DVD. MRRs will also be located at each site to extend the measurement to the column. By collecting SWER measurements using different instrument types that employ different measurement techniques our objective is to separate measurement uncertainty from natural variability in SWER and PSD. As demonstrated using C3VP polarimetric radar, gauge, and 2DVD/PD datasets these measurements can be combined to bootstrap an area wide SWER estimate via constrained modification of density-diameter and radar reflectivity-snowfall relationships. These data will be combined with snowpack, airborne microphysics, radar, radiometer, and tropospheric sounding data to refine GPM snowfall retrievals. The gauge and disdrometer instruments are being developed to operate autonomously when necessary using solar power and wireless communications. These systems will be deployed in numerous field campaigns through 2016. Planned deployment of these systems include field campaigns in Finland (2010), Oklahoma (2011), Canada (2012) and North Carolina (2013). GPM will also deploy 20 pairs of TBRGs within a 25 km2 region along the Virginia coast under NASA NPOL radar coverage in order to quantify errors in point-area rainfall measurements.

Petersen, Walter A.↗

Pressure-Volume-Temperature (PVT) Gauging of an Isothermal Cryogenic Propellant Tank Pressurized with Gaseous Helium

Results are presented for pressure-volume-temperature (PVT) gauging of a liquid oxygen/liquid nitrogen tank pressurized with gaseous helium that was supplied by a high-pressure cryogenic tank simulating a cold helium supply bottle on a spacecraft. The fluid inside the test tank was kept isothermal by frequent operation of a liquid circulation pump and spray system, and the propellant tank was suspended from load cells to obtain a high-accuracy reference standard for the gauging measurements. Liquid quantity gauging errors of less than 2 percent of the tank volume were obtained when quasi-steady-state conditions existed in the propellant and helium supply tanks. Accurate gauging required careful attention to, and corrections for, second-order effects of helium solubility in the liquid propellant plus differences in the propellant/helium composition and temperature in the various plumbing lines attached to the tanks. On the basis of results from a helium solubility test, a model was developed to predict the amount of helium dissolved in the liquid as a function of cumulative pump operation time. Use of this model allowed correction of the basic PVT gauging calculations and attainment of the reported gauging accuracy. This helium solubility model is system specific, but it may be adaptable to other hardware systems.

VanDresar, Neil T.↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗