Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphical workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Guiding the choice of informatics software and tools for lipidomics research applications

Progress in mass spectrometry lipidomics has led to a rapid proliferation of studies across biology and biomedicine. These generate extremely large raw datasets requiring sophisticated solutions to support automated data processing. To address this, numerous software tools have been developed and tailored for specific tasks. However, for researchers, deciding which approach best suits their application relies on ad hoc testing, which is inefficient and time consuming. Here we first review the data processing pipeline, summarizing the scope of available tools. Next, to support researchers, LIPID MAPS provides an interactive online portal listing open-access tools with a graphical user interface. This guides users towards appropriate solutions within major areas in data processing, including (1) lipid-oriented databases, (2) mass spectrometry data repositories, (3) analysis of targeted lipidomics datasets, (4) lipid identification and (5) quantification from untargeted lipidomics datasets, (6) statistical analysis and visualization, and (7) data integration solutions. Detailed descriptions of functions and requirements are provided to guide customized data analysis workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Enabling the democratization of the genomics revolution with a fully integrated web-based bioinformatics platform, Version 1.5 and 1.x.

EDGE bioinformatics was developed to help biologists process Next Generation Sequencing data (in the form of raw FASTQ files), even if they have little to no bioinformatics expertise. EDGE is a highly integrated and interactive web-based platform that is capable of running many of the standard analyses that biologists require for viral, bacterial/archaeal, and metagenomic samples. EDGE provides the following analytical workflows: quality trimming and host removal, assembly and annotation, comparisons against known references, taxonomy classification of reads and contigs, whole genome SNP-based phylogenetic analysis, and PCR analysis. EDGE provides an intuitive web-based interface for user input, allows users to visualize and interact with selected results (e.g. JBrowse genome browser), and generates a final detailed PDF report. Results in the form of tables, text files, graphic files, and PDFs can be downloaded. A user management system allows tracking of an individual’s EDGE runs, along with the ability to share, post publicly, delete, or archive their results.

Chain, Patrick↗

Apollo: Democratizing genome annotation

Genome annotation is the process of identifying the location and function of a genome's encoded features. Improving the biological accuracy of annotation is a complex and iterative process requiring researchers to review and incorporate multiple sources of information such as transcriptome alignments, predictive models based on sequence profiles, and comparisons to features found in related organisms. Because rapidly decreasing costs are enabling an ever-growing number of scientists to incorporate sequencing as a routine laboratory technique, there is widespread demand for tools that can assist in the deliberative analytical review of genomic information. To this end, we present Apollo, an open source software package that enables researchers to efficiently inspect and refine the precise structure and role of genomic features in a graphical browser-based platform. Some of Apollo's newer user interface features include support for real-time collaboration, allowing distributed users to simultaneously edit the same encoded features while also instantly seeing the updates made by other researchers on the same region in a manner similar to Google Docs. Its technical architecture enables Apollo to be integrated into multiple existing genomic analysis pipelines and heterogeneous laboratory workflow platforms. Finally, we consider the implications that Apollo and related applications may have on how the results of genome research are published and made accessible.

59 BASIC BIOLOGICAL SCIENCES↗

Enabling the democratization of the genomics revolution with a fully integrated web-based bioinformatics platform, Version 1.5 and 1.x.

EDGE bioinformatics was developed to help biologists process Next Generation Sequencing data (in the form of raw FASTQ files), even if they have little to no bioinformatics expertise. EDGE is a highly integrated and interactive web-based platform that is capable of running many of the standard analyses that biologists require for viral, bacterial/archaeal, and metagenomic samples. EDGE provides the following analytical workflows: quality trimming and host removal, assembly and annotation, comparisons against known references, taxonomy classification of reads and contigs, whole genome SNP-based phylogenetic analysis, and PCR analysis. EDGE provides an intuitive web-based interface for user input, allows users to visualize and interact with selected results (e.g. JBrowse genome browser), and generates a final detailed PDF report. Results in the form of tables, text files, graphic files, and PDFs can be downloaded. A user management system allows tracking of an individual’s EDGE runs, along with the ability to share, post publicly, delete, or archive their results.

Chain, Patrick↗

SU-E-T-107: Development of a GPU-Based Dose Delivery System for Adaptive Pencil Beam Scanning

Purpose: A description of a GPU-based dose delivery system (G-DDS) to integrate a fast forward planning implementing in real-time the prescribed sequence of pencil beams. The system, which is under development, is designed to evaluate the dose distribution deviations due to range variations and interplay effects affecting mobile tumors treatments. Methods: The Dose Delivery System (DDS) in use at the Italian Centro Nazionale di Adroterapia Oncologica (CNAO), is the starting point for the presented system. A fast and partial forward planning (FP) tool has been developed to evaluate in few seconds the delivered dose distributions using the DDS data (on-line measurements of spot properties, i.e. number of particles and positions). The computation is performed during the intervals between synchrotron spills and, made available at the end of each spill. In the interval between two spills, the G-DDS will evaluate the delivered dose distributions taking into account the real-time target positions measured by a tracking system. The sequence of prescribed pencil beams for the following spill will be adapted taking into account the variations with respect to the original plan due to the target motion. In order to speed up the computation required to modify pencil beams distribution (up to 400 times has been reached), the Graphics Processing Units (GPUs) and advanced Field Programmable Gate Arrays (FPGAs) are used. Results: An existing offline forward planning is going to be optimized for the CUDA architecture: the gain in time will be presented. The preliminary performances of the developed GPU-based FP algorithms will be shown. Conclusion: A prototype of a GPU-based dose delivery system is under development and will be presented. The system workflow will be illustrated together with the approach adopted to integrate the three main systems, i.e. CNAO dose delivery system, fast forward planning, and tumor tracking system.

60 APPLIED LIFE SCIENCES↗

microMS: A Python Platform for Image-Guided Mass Spectrometry Profiling

Image-guided mass spectrometry (MS) profiling provides a facile framework for analyzing samples ranging from single cells to tissue sections. The fundamental workflow utilizes a whole-slide microscopy image to select targets of interest, determine their spatial locations, and subsequently perform MS analysis at those locations. Improving upon prior reported methodology, a software package was developed for working with microscopy images. microMS, for microscopy-guided mass spectrometry, allows the user to select and profile diverse samples using a variety of target patterns and mass analyzers. Written in Python, the program provides an intuitive graphical user interface to simplify image-guided MS for novice users. The class hierarchy of instrument interactions permits integration of new MS systems while retaining the feature-rich image analysis framework. microMS is a versatile platform for performing targeted profiling experiments using a series of mass spectrometers. The flexibility in mass analyzers greatly simplifies serial analyses of the same targets by different instruments. The current capabilities of microMS are presented, and its application for off-line analysis of single cells on three distinct instruments is demonstrated. The software has been made freely available for research purposes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reproducible Data Processing Research for the CABRI R.I.A. experiments Acoustic Emission signal analysis

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission (CEA) designed to study the behaviour of fuel rods at high burnup under Reactivity Initiated Accident (R.I.A.) conditions such as the scenario of a control rod ejection. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream from the test device. Studies carried out on the last fourteen tests showed the interest in carrying out temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena. We want presently to return to this rich data in order to have a new point of view by applying modern signal processing methods. Such an antecedent works resumption leads to some difficulties. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not clear in reproducing from the former studies since the people who were in charge of the original work have left the laboratory and it is not easy when time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup. Thus we decided to consolidate the availability of the data and its manipulation in order to provide a robust data processing workflow to the experimentalists before doing any further investigations. To tackle this issue of strong links between data, treatments and the generation of documents, we adopted a Reproducible Research paradigm. We shall first present the tools chosen in our laboratory to implement this workflow and, then we shall describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the last fourteen CABRI R.I.A. tests. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Future of Visualization Technology Vis in Practice

Two decades ago, we witnessed an inflection point as graphics programming became commoditized. A comparable inflection point may be on the horizon, this time driven by the commoditization of immersive display technology with Augmented Reality (AR), Virtual Reality (VR), and Extended Reality (XR) technologies poised to redefine our interaction with data, environments, and collaboration. To drive the technology and its application, we should consider the lessons learned from successful large-scale immersive installations. Where these installations have thrived is by enhancing traditional workflows rather than entirely replacing them, supporting improved judgments of complex spaces, direct interaction in 3D, and embedding high-dimensional data.

AR/VR↗

Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter- and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints.

60 APPLIED LIFE SCIENCES↗

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗

Towards a study protocol: A data-driven workflow to identify error sources in direct ink write mechatronics

Abstract Using Direct Ink Write (DIW) technology in a rapid and large-scale production requires reliable quality control for printed parts. Data streams generated during printing, such as print mechatronics, are massive and diverse which impedes extracting insights. In our study protocol approach, we developed a data-driven workflow to understand the behavior of sensor-measured X- and Y- axes positional errors with process parameters, such as print velocity and velocity control. We uncovered patterns showing that instantaneous changes in the velocity, when the build platform accelerates and decelerates, largely influence the positional errors, especially in the X- axis due to the hardware architecture. Since DIW systems share similar mechatronic inputs and outputs, our study protocol approach is broadly applicable and scalable across multiple systems. Graphical abstract

36 MATERIALS SCIENCE↗

Enabling AI in synthetic biology through Construction File specification

The Construction File (CF) specification establishes a standardized interface for molecular biology operations, laying a foundation for automation and enhanced efficiency in experiment design. It is implemented across three distinct software projects: PyDNA_CF_Simulator, a Python project featuring a ChatGPT plugin for interactive parsing and simulating experiments; ConstructionFileSimulator, a field-tested Java project that showcases 'Experiment' objects expressed as flat files; and C6-Tools, a JavaScript project integrated with Google Sheets via Apps Script, providing a user-friendly interface for authoring and simulation of CF. The CF specification not only standardizes and modularizes molecular biology operations but also promotes collaboration, automation, and reuse, significantly reducing potential errors. The potential integration of CF with artificial intelligence, particularly GPT-4, suggests innovative automation strategies for synthetic biology. While challenges such as token limits, data storage, and biosecurity remain, proposed solutions promise a way forward in harnessing AI for experiment design. This shift from human-driven design to AI-assisted workflows, steered by high-level objectives, charts a potential future path in synthetic biology, envisioning an environment where complexities are managed more effectively.

59 BASIC BIOLOGICAL SCIENCES↗

Tracking Files Using the Kepler Provenance Framework

Workflow Management Systems (WFMS), such as Kepler, are proving to be an important tool in scientific problem solving. They can automate and manage complex processes and huge amounts of data produced by petascale simulations. Typically, the produced data need to be properly visualized and analyzed by scientists in order to achieve the desired scientific goals. Both run-time and post analysis may benefit from, even require, additional meta-data - provenance information. One of the challenges in this context is the tracking of the data files that can be produced in very large numbers during stages of the workflow, such as visualizations. The Kepler provenance framework collects all or part of the raw information flowing through the workflow graph. This information then needs to be further parsed to extract meta-data of interest. This can be done through add-on tools and algorithms. We show how to automate tracking specific information such as data files locations.

97 MATHEMATICS AND COMPUTING↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A User-Friendly GUI Tool for Automated Microstructural Analysis of Fiber-Reinforced Composites and Porous Structures

Understanding and quantifying microstructural features such as fiber orientation and porosity is critical for predicting the mechanical behavior and performance of fiber-reinforced polymer composites. Traditional manual analysis is time-consuming, subjective, and unsuitable for high-throughput datasets. We present a graphical user interface (GUI) application that automates the analysis of microscopy images to extract key microstructural metrics, including fiber orientation tensors, fiber orientation distribution, porosity and pore size distribution. The app integrates multiple image segmentation techniques including global and local thresholding, clustering, and region-based approaches, offering flexibility for different types of image qualities and features. Users can load microstructural images, select regions of interest and segmentation techniques tailored to their image dataset. It also addresses a critical challenge in fiber orientation analysis: the ambiguities caused by touching, overlapping, or partially cut fibers. It supports autorun examples for standardized workflows, enabling reproducible analysis and facilitating training and benchmarking. This tool significantly reduces manual intervention, enhances consistency, and accelerates data generation for structure–property modeling, process optimization, and digital materials research. The tool is intended for use by materials scientists, engineers, and researchers engaged in composite characterization, quality control, and machine learning-based microstructural studies.

Chawla, Komal [ORNL] (ORCID:0000000190327565)↗

NEAMS Workbench MOOSE Integration Update

The Nuclear Energy Advanced Modeling and Simulation (NEAMS) Workbench is a graphical user interface (GUI) that provides a common analysis environment for the accelerated use of the NEAMS toolkit. To improve design and analysis of current and future nuclear energy systems, the NEAMS Workbench provides an integrated development environment for model creation, review, execution, output review, and visualization for integrated tools. In addition to a GUI, the NEAMS Workbench provides the Workbench Analysis Sequence Processor, an open-source tool set that facilitates input-content assistance for supported domain-specific input languages and user-friendly syntaxes. These supported syntaxes enable accelerated development and deployment of enhanced user inputs and workflows. The Multiphysics Object-Oriented Simulation Environment (MOOSE) has been supported in the NEAMS Workbench since 2016 and receives continuous updates. Efforts to improve MOOSE-based tool integration in the NEAMS Workbench are ongoing. This document details the current and planned enhancements of the NEAMS Workbench and the MOOSE framework to improve integration and usability of MOOSE-based applications within the NEAMS Workbench.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Performance Computing Peak Shaving for Microreactor Operation

There are multiple nuclear microreactors currently under development that are designed to provide autonomous power for as many as ten or more years without refueling and are designed to power high performance computing (HPC) datacenters. But the load-follow speeds for a nuclear microreactor will be much slower than grid power and slower than the power variance typical of a HPC system. HPC datacenters experience peak power load variance driven by several factors ranging from the operation of cooling systems to remove heat from the servers to supporting a wide range of user application workflows and architectures each with different power signatures. One mechanism to support the limited load-follow of a microreactor is peak shaving where an energy storage mechanism is used to shed peak load and reduce significant power variance. This work explores peak electrical load shaving using uninterruptible power supply (UPS) systems designed for HPC support in the context of peak shaving when operating using a nuclear microreactor with a load-follow limited to 10% of load per minute. Using a self contained HPC datacenter complete with stand-alone cooling system and provisioned with an x86 cluster, an ARM cluster, and a graphics processing unit (GPU) cluster, peak shaving for microreactor operation using the UPS battery backup is explored while running two classes of typical HPC user applications. HPC architecture suitability for microreactor operation under this type of peak shaving is examined.

97 MATHEMATICS AND COMPUTING↗

Surface Triangulation for CSG in Mercury

Visualization routines for rendering complicated geometries are very useful for engineers and scientists who are trying to build 3D prototypes of their designs. A common way to rapidly add interesting features to a 3D model is through the use of a concept called Constructive Solid Geometry. CSG uses compositions of the boolean set operations to manipulate basic geometric primitives to form more complicated objects. The most common boolean operations employed are union, intersection, and subtraction. Most computer-aided design software packages contain some sort of ability visualize CSG. The typical workflow for the user is as follows: The user specifies the individual primitive components, the user arbitrarily combines each of these primitives with boolean operations, the software generates a CSG tree structure which normally stores these solids implicitly with their defining equation, the tree is traversed and a general algorithm is applied to render the appropriate geometry onto the screen. Algorithms for visualizing CSG have been extensively developed for over a decade. Points sampled from the implicit solids are typically used as input by variations of algorithms like marching cubes and point-cloud surface reconstruction. Here, we explain a surface triangulation method from the graphics community that is being used for surface visualization in the framework of a Monte-Carlo neutron transport code called Mercury.

97 MATHEMATICS AND COMPUTING↗