Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite specimens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Validation of the IMCE RFDA System for Dynamic Elastic Moduli Measurements

The focus of this report is to describe the new system that has been acquired for the Low Activation Material Development and Analysis Laboratory (LAMDA) to perform the measurement of the dynamic Young’s and shear moduli, and to show that the results of the new system are more easily analyzed and more accurate than the current systems. The current system is the GrindoSonic MK5 Impulse Excitation and Vibration Test System from J.W. Lemmens, Inc., and the new system is the Resonant Frequency and Damping Analyser (RFDA) from Integrated Material Control Engineering (IMCE). A comparison between the results from both systems was performed with nine specimen shapes and five graphite grades. All of the results showed agreement of the moduli values within 1-2%. The only outliers were a 20% disagreement for one specimen shape and a 5-10% disagreement for a second specimen shape, but it was shown that this occurred because the GrindoSonic system was reporting the frequency for the flexural harmonic peak rather than the fundamental torsional peak.

36 MATERIALS SCIENCE↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-1 Specimen Post Irradiation Data Report

Here we report the results of the Post Irradiation Examination (PIE) of the creep, control, and piggyback specimens from the irradiation creep capsule AGC-1. This is the first (prototype) of a series of six capsules planned as part of the Advanced Graphite Creep (AGC) experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphites. The data reported include: specimen dimensions and hence the dimensional change upon irradiation (a comparison of these data for specimen matched pairs will yield the creep strain); mass and volume, hence density; elastic constants (Young’s modulus, shear modulus and Poisson’s ratio) from ultrasonic time of flight (TOF) and velocity measurements; Young’s modulus from the fundamental frequency of vibration; electrical resistivity; and thermal expansion from 100-550°C (hence coefficient of thermal expansion). Over 8500 individual physical measurement have been made and the data are reduced and reported here. The AGC-1 capsule was irradiated in the Advanced Test Reactor (ATR) at INL at approximately 700°C and to a peak dose of 7 dpa (displacements per atom). The specimen’s final dose, temperature and stress conditions have been reported by INL and are also tabulated here. Additionally the analysis of the SiC temperature monitors is reported. These temperature monitors were located along the center of the AGC-1 capsule and provide an independent assessment of the capsules final irradiation temperature. While all the PIE testing is reported (with the exception of the glued-end tensile strength specimens) additional analysis of the AGC data will be required to allow: 1. Improved fits to the existing models of graphite irradiation induced creep strain. 2. With the eventual advent of temperature dependency data from the additional AGC series of capsules, and microstructural data from piggy back specimens in AGC capsules, the development of new and improved models for the development of irradiation induced creep strain in graphite are anticipated. 3. An Investigation into the effects of creep strain on the physical properties of irradiated graphite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A New Test Method for Determining the Strength and Fracture Toughness of Cement Mortar and Concrete

The Spiral Notch Torsion Fracture Toughness Test (SNTT) was developed recently to determine the intrinsic fracture toughness (KIC) of structural materials. The SNTT system operates by applying pure torsion to uniform cylindrical specimens with a notch line that spirals around the specimen at a 45 a pitch. KIC values are obtained with the aid of a three-dimensional finite-element computer code, TOR3D-KIC. The SNTT method is uniquely suitable for testing a wide variety of materials used extensively in pressure vessel and piping structural components and weldments. Application of the method to metallic, ceramic, and graphite materials has been demonstrated. One important characteristic of SNTT is that neither a fatigue precrack or a deep notch are required for the evaluation of brittle materials, which significantly reduces the sample size requirement. In this paper we report results for a Portland cement-based mortar to demonstrate applicability of the SNTT method to cementitious materials. The estimated KIC of the tested mortar samples with compressive strength of 34.45 MPa was found to be 0.19 MPa m^(1/2).

36 MATERIALS SCIENCE↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-2 Specimen Post Irradiation Data Package Report

This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-2 Specimen Post Irradiation Data Package Report

This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time of flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-3 Specimen Load Calculations by Stack

This Engineering Calculations and aAnalysis Report (ECAR) documents the results of the threshold averaging on the load cell data taken during the third advanced graphite creep (AGC) test, AGC 3. Specimens were irradiated in the Advance Test Reactor (ATR) during Cycles 152B, 154B, 155A, and 155B (the AGC-3 capsule was not in ATR for Cycles 153A/B and 154A). During each cycle, the specimens located in the upper portions of the stacks were subjected to a compressive load. The applied load of each stack was monitored and load data were recorded in 1 minute intervals. Collecting data detailing the loads applied over the life of the experiment is necessary for use in future analyses. This load summary data will be used in creep rate estimations and post irradiation examination of material properties.

42 ENGINEERING↗

AGC Experiment Status

AGC Experiment Status to include: History and status of the AGC-4, Review of the AGC experiment, AGC graphite grades and samples, The AGC-4 capsule and specimens, and HDG-1 and HDG-2. Description of the Experiment, AGC graphite grades and samples, AGC-1 Test Train, AGC-1 Test Train Design Features, New AGC Irradiation Schedule (2018) and update in schedule, Irradiation and disassembly history, present and future status, and shipment and initial PIE. Initial PIE strategy, recovered specimens, PIE results, and status of experiments.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Density Change of an Oxidized Nuclear Graphite by Acoustic Microscopy and Image Processing

The strong correlation between the density and the physical and mechanical properties of graphite suggests that the method of nondestructive density evaluation could be developed into a characterization technique of great value for the overall improvement of safety of graphite moderator reactors. In this study, the oxidation-induced density changes in nuclear graphite for VHTR were determined by a conventional destructive bulk density measurement method (BM), and by a new non-destructive method based on acoustic microscopy and image processing (AM). The results were compared in order to validate the applicability of the latter method. For a direct comparison of the results from both measurements, two specimens were prepared from a cylindrical graphite sample (1 inch diameter and 1 inch height, oxidized to 10% weight loss at 700 oC in air for 5 hours). The specimens were used for characterization by BM and AM methods, respectively. The results show that, even with a large standard deviation of the AM, the density changing trend from both methods appeared the same. Present observation may be attributed to the fact that AM images reflect characteristic density changes of the graphite sample through the acoustic impedance changes. This study demonstrates the possibility of using AM as a nondestructive technique for the evaluation of density changes in graphite when a database is prepared through a systematic series of experiments.

36 MATERIALS SCIENCE↗

Graphite Characterization: Baseline Variability Analysis Report

The Idaho National INL’s Baseline Material Property program provides many measurements of different material properties on a variety of nuclear graphite grades being investigated for irradiation-induced changes in material properties. The baseline material properties provide an unirradiated reference for comparison with measurements of those properties after irradiation. This study describes how uncertainty, or variance, in estimates of important material properties, like compressive strength, may depend on sample size, sample distribution and parameter estimation methods. Compressive strength data from two large collections of specimens from a billet of PCEA graphite (sample size = 230) and a billet of IG-110 graphite (sample size = 48) are used to illustrate these dependencies. The grades of graphite used represent approximate end members in terms of relative variability in strength measurements. Monte Carlo simulation and bootstrapping methods were used to examine variance in Weibull-parameter estimates as a function of sample size. Results were consistent with what previous statistical analyses have shown about the relationship between sample size and width of the confidence interval for maximum likelihood (ML) estimated parameters when samples are repeatedly drawn from a Weibull distribution. As a function of sample size, the precision of the modulus estimate increases faster than that of the characteristic strength. The modulus maximum likelihood estimates (MLEs) are biased for low sample sizes. The American Society for Testing and Materials document ASTM D7846-16 provides equations that describe the dependence of the variance of parameter MLEs on sample size. Using the same methodology, we show that the polynomials provided for variance dependence on sample size are inaccurate for sample sizes greater than ~120. We provide approximations to that relationship that illustrate relative constancy for sample size > ~10, in the logspace relationship of the modulus variance and the log transformed characteristic strength variance. Bootstrapping provided a means of comparing Weibull parameters obtained using ASME’s guidance for specimen collection to those obtained using different weighting in a case where strength is related to position in a billet and to grain orientation and a single distribution is used to characterize the billet. ASME specifies that samples be collected with equal representation in all locations and grain orientations. Parameter values obtained using ASME’s method were different from those obtained using random sampling of the complete data sets, and this was particularly true for the PCEA data. In addition, while the ASME approach yielded more conservative parameters for the PCEA data, the opposite was true for the IG-110 data. The difference observed for the PCEA data set likely reflects the larger number of against-grain specimens collected, which had generally higher strength than the with-grain specimens. This emphasizes the importance of the dependence of strength on location or grain orientation and suggests that it may be prudent to weight specimen collection toward the weaker subgroups if a conservative estimate as desired, as the equal weighting method recommended by ASME would will not always provide the most conservative Weibull parameters. Because spatial correlations commonly exist in certain grades of graphite, future work may involve developing a methodology for parameter inference that relaxes the assumption of independent specimens. ASTM and ASME codes recommend different parameter estimation methods and models of the Weibull distribution in different situations. Descriptions of the effects on parameter estimates for the example billets used in this study provide an example of how the method may affect the parameter estimate, and how—in this case—that compares to differences due to other factors, such as sample size and dependence on grain orientation or sample location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The shear fracture toughness, K IIc , of graphite

In this study, the critical shear stress intensity factor, K IIc , here-in referred to as the shear fracture toughness, K IIc (MPa m), of two grades of graphite are reported. The range of specimen volumes was selected to elucidate any specimen size effect, but smaller volume specimen tests were largely unsuccessful, shear failure did not occur between the notches as expected. This was probably due to the specimen geometry causing the shear fracture stress to exceed the compressive failure stress. In subsequent testing the specimen geometry was altered to reduce the compressive footprint and the notches (slits) made deeper to reduce the specimen's ligament length. Additionally, we added the collection of Acoustic Emission (AE) during testing to assist with the identification of the shear fracture load. The means of K IIc from large specimens for PCEA and NBG-18 are 2.26 MPa m with an SD of 0.37 MPa m and 2.20 MPa m with an SD of 0.53 MPa m, respectively. The value of K IIc for both graphite grades was similar, although the scatter was large. In this work we found the ratio of K IIc / K Ic ≈ 1.6. .

36 MATERIALS SCIENCE↗

Modelling the graphite fracture mechanisms

In order to define a design criterion for graphite components, it is important to identify the physical phenomena responsible for the graphite fracture, to include them in a more effective modelling. In a first step, a large panel of experiments have been realised in order to build up an important database; results of tensile tests, 3 and 4 point bending tests on smooth and notched specimens have been analysed and have demonstrated an important geometry related effects on the behavior up to fracture. Then, first simulations with an elastic or an elastoplastic bilinear constitutive law have not made it possible to simulate the experimental fracture stress variations with the specimen geometry, the fracture mechanisms of the graphite being at the microstructural scale. That is the reason why a specific F.E. model of the graphite structure has been developed in which every graphite grain has been meshed independently, the crack initiation along the basal plane of the particles as well as the crack propagation and coalescence have been modelled too. This specific model has been used to test two different approaches for fracture initiation: a critical stress criterion and two criteria of fracture mechanic type. They are all based on crystallographic considerations as a global critical stress criterion gave unsatisfactory results. The criteria of fracture mechanic type being extremely unstable and unable to represent the graphite global behaviour up to the final collapse, the critical stress criterion has been preferred to predict the results of the large range of available experiments, on both smooth and notched specimens. In so doing, the experimental observations have been correctly simulated: the geometry related effects on the experimental fracture stress dispersion, the specimen volume effects on the macroscopic fracture stress and the crack propagation at a constant stress intensity factor. In addition, the parameters of the criterion have been related to experimental observations: the local crack initiation stress of 8 MPa corresponds to the non-linearity apparition on the global behavior observed experimentally and the the maximal critical stress defined for the particle of 30 MPa is equivalent to the fracture stress of notched specimens. This innovative combination of crack modelling and a local crystallographic critical stress criterion made it possible to understand that cleavage initiation and propagation in the graphite microstructure was driven by a mean critical stress criterion. (authors)

36 MATERIALS SCIENCE↗