At least 91 records · Page 5

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Carbon Capture and Storage in Hydrogen Production: A Combined Techno-Economic and Life Cycle Assessment

This paper presents a coupled techno-economic and life cycle assessment of “blue” hydrogen to be produced at a hydrogen facility through steam methane reforming (SMR) equipped with carbon capture and storage (CCS). Blue hydrogen was modeled in ChemCAD, while an integrated asset model represented the carbon capture and storage chain. An unabated carbon dioxide (CO 2 ) configuration release 11.99 kgCO 2 -eq/ kgH 2 . Capturing ≥95% of the CO 2 stream lowers the carbon footprint to 6.59 kgCO 2 -eq/kgH2 but raises the levelized cost of hydrogen (LCOH) from $\$$1.82/kgH 2 (no CO 2 capture) to $\$$3.22/kgH 2 ; the U.S. 45Q tax credit reduces it to $\$$2.59/kgH 2 . Incorporating CCS reduces the levelized net present value from $\$$0.87/kgH 2 to $\$$0.74/kgH 2 , owing to additional capture, transport, and storage costs. Supplying SMR with low-carbon electricity, especially nuclear, wind, or hydro, delivers the lowest carbon footprint relative to geothermal or grid mixes. Sensitivity analysis identifies that hydrogen sales price, internal rate of return, and CCS cost as the strongest economic levers, while electricity demand dominates residual lifecycle emissions. The results underscore a clear trade-off; substantial CO 2 reductions are achievable, but only with higher production costs, making supportive policy instruments, access to clean power, and robust hydrogen markets essential for large-scale deployment of blue hydrogen.

carbon capture↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

esm_watermasses

A water mass analysis package for gridded ocean and atmospheric data and Earth system model output

Moore-Maley, Ben [@SciDAC-ImPACTS @E3SM-Project @M↗

Powered By: Transmission Planning

Presented as part of the NREL Grid Planning and Analysis Center's (GPAC) "Powered By" Series, this iteration focuses not on a specific tool but instead on a domain of expertise/capability being built out at NREL: transmission planning. Various sets of tools are integrated together in this presentation to present a combination of transmission focus areas, case studies, tools and future directions of transmission research.

capacity expansion↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Study of eVTOL Charging Impact on Airport Electrical Grids

Growth in commercial air traffic has increased the aviation industry's contribution to global emissions. Aircraft electrification can reduce greenhouse gas emissions along with being efficient and reliable. Advanced air mobility introduces the idea of an advanced and more efficient air transportation system. Electric and hybrid aircraft designs, such as electric vertical takeoff and landing (eVTOL), are being considered for a number of applications, such as urban air mobility, cargo delivery, and medical emergencies. Although the electrification of aircraft provides environmental benefits, their charging needs will place significant demand on the electrical grid. This work presents a grid impact study and infrastructure upgrade requirements analysis of eVTOL charging on a realistic distribution grid through power flow simulation analysis. The case study results show that the eVTOL charging can lead to power quality issues, such as undervoltage and equipment capacity overloading. Grid infrastructure, such as lines and transformers, would need to be upgraded, and voltage management strategies would need to be deployed to accommodate eVTOL charging at an existing airport.

advanced air mobility (AAM)↗

Consequential Analysis of the Greenhouse Gas Emissions Impacts of Actions That Influence the Electric Grid: The Theory and Practice of Using Marginal Emissions Rates

This paper discusses consequential greenhouse gas emissions analysis for actions that influence the electric grid that is, the analytical approach of estimating how such actions change greenhouse gas emissions, relative to what they otherwise would have been without the action. Although the paper starts with general considerations, it ultimately focuses on consequential analysis with marginal emissions rates as an option likely more scalable than others.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CEC Quest: Long Duration Energy Storage Impact Analysis Tool

SAND2025-14389O CEC Quest is a Python tool with a user interface designed to analyze the greenhouse gas impacts of long-duration energy storage projects in California. The tool automates data collection from public sources and uses an Application Programming Interface (API) to enable users to download photovoltaic resource availability, marginal operating emissions rate, and utility rate data. It guides users in inputting parameters for a battery energy storage model and uploading site electrical load data, while also prompting for relevant analysis parameters like timestep and grid limits. CEC Quest performs monthly optimization of one year of data to assess impacts on the site’s electrical bill and the grid’s greenhouse gas emissions. Finally, it conducts a lifecycle analysis to evaluate changes over a defined quantification period, with results aggregated through automated report generation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David [Sandia National Lab. (SNL-CA), L↗

Nuclear Integrated Hydrogen Production Analysis Tool

This is an Excel-based time-independent discount cash flow calculator for LWR-HTSE systems. The tool incorporates (1) discounted cash flow and levelized cost of hydrogen (LCOH) analysis, (2) sensitivity analysis with respect to select financial performance metrics with output ‘tornado’ charts, (3) profitability analysis represented by heat maps using the two most sensitive parameters, (4) electricity versus hydrogen production preference analysis by comparing change in net present value (?NPV) between NPP-HTSE and business-as-usual electricity production for the grid, and (5) competitiveness analysis by comparing the calculated LCOH for NPP-HTSE with that of steam methane reforming, which is the conventional process to produce hydrogen.

Cheng, WenChi [Idaho National Laboratory (INL), Id↗

Fine Temperature Grid Continuous Energy Cross Section Generation for Monte Carlo Analysis of Xe-100 Design

The standard “A Compact ENDF (ACE)” data libraries used by Monte Carlo based reactor physics codes calculations are provided by Los Alamos National Laboratory (LANL) with a temperature interval mostly of 300 K (e.g. 300 K, 600 K, 900 K) for the cross sections and between 100 K and 200 K for the thermal scattering libraries (TSL). However, some codes such as MCNP lack capability to perform on-the-fly temperature interpolation during simulation both for neutron and TSL cross-sections. To evaluate the impact related to Doppler broadening and spectrum shift associated with TSL changes, this paper explores the potential of adopting a temperature grid finer than the ones contained in the standard data libraries. A 50 K temperature grid was employed to quantify the error in neutronics calculations due to temperature grid resolution. This was achieved by comparing the results of this study (50 K temperature interval) against the results obtained with standard data libraries (>100 K temperature interval). While the adopted grid primarily relies on the ENDF/B-VII.1 library, for neutron cross-sections, it utilizes ENDF/B-VIII.0 library for TSL. The analyses confirmed that the accuracy of neutronics calculations is satisfactory when using a 50 K temperature grid. Notably, adopting a 50 K temperature grid, as opposed to standard libraries or coarser temperature grids, could lead to a difference of no more than a few hundred pcm in dk for both fresh fuel and burnt fuel. The most sensitive reaction type to the temperature grid was as expected identified as the capture cross-section of U-238.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗