Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microgravity alters respiratory sinus arrhythmia and short-term heart rate variability in humans

We studied heart rate (HR), heart rate variability (HRV), and respiratory sinus arrhythmia (RSA) in four male subjects before, during, and after 16 days of spaceflight. The electrocardiogram and respiration were recorded during two periods of 4 min controlled breathing at 7.5 and 15 breaths/min in standing and supine postures on the ground and in microgravity. Low (LF)- and high (HF)-frequency components of the short-term HRV (< or =3 min) were computed through Fourier spectral analysis of the R-R intervals. Early in microgravity, HR was decreased compared with both standing and supine positions and had returned to the supine value by the end of the flight. In microgravity, overall variability, the LF-to-HF ratio, and RSA amplitude and phase were similar to preflight supine values. Immediately postflight, HR increased by approximately 15% and remained elevated 15 days after landing. LF/HF was increased, suggesting an increased sympathetic control of HR standing. The overall variability and RSA amplitude in supine decreased postflight, suggesting that vagal tone decreased, which coupled with the decrease in RSA phase shift suggests that this was the result of an adaptation of autonomic control of HR to microgravity. In addition, these alterations persisted for at least 15 days after return to normal gravity (1G).

Clinical Trial↗

Influence of trimetazidine on the synthesis of complex lipids in the heart and other target organs

Trimetazidine exerts antianginal properties at the cellular level, without haemodynamic effect in clinical and experimental conditions. This cytoprotection was attributed to a decreased utilization of fatty acids for energy production, balanced by an increased incorporation in structural lipids. This study evaluated the influence of Trimetazidine on complex lipid synthesis from [2-(3)H] glycerol, in ventricular myocytes, isolated rat hearts and in vivo in the myocardium and several other tissues. In cardiomyocytes, Trimetazidine increased the synthesis of phosphatidyl-choline (+ 80%), phosphatidyl-ethanolamine (+ 210%), phosphatidyl-inositol (+ 250%) and cardiolipid (+ 100%). The common precursor diacylglycerol was also increased (+ 40%) whereas triacylglycerol was decreased (-70%). Similar results were obtained in isolated hearts with 10 microm Trimetazidine (phosphatidyl-choline + 60%, phosphatidyl-ethanolamine + 60%, phosphatidyl-inositol + 100% and cardiolipid + 50%), the last two phospholipids containing 85% of the radioactivity. At 1 microm, Trimetazidine still stimulated the phospholipid synthesis although the difference was found significant only in phosphatidyl-inositol and cardiolipid. In vivo studies (10 mg/kg per day for 7 days and 5 mg/kg, i.p. before the experiment) revealed significant changes in the intracellular lipid biosynthesis, with increased labelling of phospholipids and reduced incorporation of glycerol in nonphosphorous lipids. Trimetazidine increased the glycerol uptake from plasma to the other tissues (liver, cochlea, retina), resulting in an altered lipid synthesis. The anti-anginal properties of Trimetazidine involve a reorganisation of the glycerol-based lipid synthesis balance in cardiomyocytes, associated with an increased uptake of plasma glycerol that may contribute to explain the pharmacological properties reported in other organs.

Trimetazidine/pharmacology↗

Heart rate dynamics in patients with stable angina pectoris and utility of fractal and complexity measures

Dynamic analysis techniques may uncover abnormalities in heart rate (HR) behavior that are not easily detectable with conventional statistical measures. However, the applicability of these new methods for detecting possible abnormalities in HR behavior in various cardiovascular disorders is not well established. Conventional measures of HR variability were compared with short-term (< or = 11 beats, alpha1) and long-term (> 11 beats, alpha2) fractal correlation properties and with approximate entropy of RR interval data in 38 patients with stable angina pectoris without previous myocardial infarction or cardiac medication at the time of the study and 38 age-matched healthy controls. The short- and long-term fractal scaling exponents (alpha1, alpha2) were significantly higher in the coronary patients than in the healthy controls (1.34 +/- 0.15 vs 1.11 +/- 0.12 [p <0.001] and 1.10 +/- 0.08 vs 1.04 +/- 0.06 [p <0.01], respectively), and they also had lower approximate entropy (p <0.05), standard deviation of all RR intervals (p <0.01), and high-frequency spectral component of HR variability (p <0.05). The short-term fractal scaling exponent performed better than other heart rate variability parameters in differentiating patients with coronary artery disease from healthy subjects, but it was not related to the clinical or angiographic severity of coronary artery disease or any single nonspectral or spectral measure of HR variability in this retrospective study. Patients with stable angina pectoris have altered fractal properties and reduced complexity in their RR interval dynamics relative to age-matched healthy subjects. Dynamic analysis may complement traditional analyses in detecting altered HR behavior in patients with stable angina pectoris.

NASA Discipline Cardiopulmonary↗

Human heart rate variability relation is unchanged during motion sickness

In a study of 18 human subjects, we applied a new technique, estimation of the transfer function between instantaneous lung volume (ILV) and instantaneous heart rate (HR), to assess autonomic activity during motion sickness. Two control recordings of ILV and electrocardiogram (ECG) were made prior to the development of motion sickness. During the first, subjects were seated motionless, and during the second they were seated rotating sinusoidally about an earth vertical axis. Subjects then wore prism goggles that reverse the left-right visual field and performed manual tasks until they developed moderate motion sickness. Finally, ILV and ECG were recorded while subjects maintained a relatively constant level of sickness by intermittent eye closure during rotation with the goggles. Based on analyses of ILV to HR transfer functions from the three conditions, we were unable to demonstrate a change in autonomic control of heart rate due to rotation alone or due to motion sickness. These findings do not support the notion that moderate motion sickness is manifested as a generalized autonomic response.

NASA Discipline Neuroscience↗

Power law behavior of RR-interval variability in healthy middle-aged persons, patients with recent acute myocardial infarction, and patients with heart transplants

BACKGROUND. The purposes of the present study were (1) to establish normal values for the regression of log(power) on log(frequency) for, RR-interval fluctuations in healthy middle-aged persons, (2) to determine the effects of myocardial infarction on the regression of log(power) on log(frequency), (3) to determine the effect of cardiac denervation on the regression of log(power) on log(frequency), and (4) to assess the ability of power law regression parameters to predict death after myocardial infarction. METHODS AND RESULTS. We studied three groups: (1) 715 patients with recent myocardial infarction; (2) 274 healthy persons age and sex matched to the infarct sample; and (3) 19 patients with heart transplants. Twenty-four-hour RR-interval power spectra were computed using fast Fourier transforms and log(power) was regressed on log(frequency) between 10(-4) and 10(-2) Hz. There was a power law relation between log(power) and log(frequency). That is, the function described a descending straight line that had a slope of approximately -1 in healthy subjects. For the myocardial infarction group, the regression line for log(power) on log(frequency) was shifted downward and had a steeper negative slope (-1.15). The transplant (denervated) group showed a larger downward shift in the regression line and a much steeper negative slope (-2.08). The correlation between traditional power spectral bands and slope was weak, and that with log(power) at 10(-4) Hz was only moderate. Slope and log(power) at 10(-4) Hz were used to predict mortality and were compared with the predictive value of traditional power spectral bands. Slope and log(power) at 10(-4) Hz were excellent predictors of all-cause mortality or arrhythmic death. To optimize the prediction of death, we calculated a log(power) intercept that was uncorrelated with the slope of the power law regression line. We found that the combination of slope and zero-correlation log(power) was an outstanding predictor, with a relative risk of > 10, and was better than any combination of the traditional power spectral bands. The combination of slope and log(power) at 10(-4) Hz also was an excellent predictor of death after myocardial infarction. CONCLUSIONS. Myocardial infarction or denervation of the heart causes a steeper slope and decreased height of the power law regression relation between log(power) and log(frequency) of RR-interval fluctuations. Individually and, especially, combined, the power law regression parameters are excellent predictors of death of any cause or arrhythmic death and predict these outcomes better than the traditional power spectral bands.

Non-NASA Center↗

Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor

A piezopolymer pressure sensor has been developed for service in a portable fetal heart rate monitor, which will permit an expectant mother to perform the fetal nonstress test, a standard predelivery test, in her home. Several sensors are mounted in an array on a belt worn by the mother. The sensor design conforms to the distinctive features of the fetal heart tone, namely, the acoustic signature, frequency spectrum, signal amplitude, and localization. The components of a sensor serve to fulfill five functions: signal detection, acceleration cancellation, acoustical isolation, electrical shielding, and electrical isolation of the mother. A theoretical analysis of the sensor response yields a numerical value for the sensor sensitivity, which is compared to experiment in an in vitro sensor calibration. Finally, an in vivo test on patients within the last six weeks of term reveals that nonstress test recordings from the acoustic monitor compare well with those obtained from conventional ultrasound.

Heart Rate, Fetal/physiology↗

Abnormalities in intracellular calcium regulation and contractile function in myocardium from dogs with pacing-induced heart failure

24 d of rapid ventricular pacing induced dilated cardiomyopathy with both systolic and diastolic dysfunction in conscious, chronically instrumented dogs. We studied mechanical properties and intracellular calcium (Ca2+i) transients of trabeculae carneae isolated from 15 control dogs (n = 32) and 11 dogs with pacing-induced cardiac failure (n = 26). Muscles were stretched to maximum length at 30 degrees C and stimulated at 0.33 Hz; a subset (n = 17 control, n = 17 myopathic) was loaded with the [Ca2+]i indicator aequorin. Peak tension was depressed in the myopathic muscles, even in the presence of maximally effective (i.e., 16 mM) [Ca2+] in the perfusate. However, peak [Ca2+]i was similar (0.80 +/- 0.13 vs. 0.71 +/- 0.05 microM; [Ca2+]o = 2.5 mM), suggesting that a decrease in Cai2+ availability was not responsible for the decreased contractility. The time for decline from the peak of the Cai2+ transient was prolonged in the myopathic group, which correlated with prolongation of isometric contraction and relaxation. However, similar end-diastolic [Ca2+]i was achieved in both groups (0.29 +/- 0.05 vs. 0.31 +/- 0.02 microM), indicating that Cai2+ homeostasis can be maintained in myopathic hearts. The inotropic response of the myopathic muscles to milrinone was depressed compared with the controls. However, when cAMP production was stimulated by pretreatment with forskolin, the response of the myopathic muscles to milrinone was improved. Our findings provide direct evidence that abnormal [Ca2+]i handling is an important cause of contractile dysfunction in dogs with pacing-induced heart failure and suggest that deficient production of cAMP may be an important cause of these changes in excitation-contraction coupling.

Non-NASA Center↗

Control system for an artificial heart

Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart.

Gebben, V. D.↗

Miniature implantable instrument measures and transmits heart function data

Heart diameter is derived from measured transit time of 2.25 MHz ultrasonic pulse between two piezoelectric crystals attached to diametrically opposite heart surfaces. Miniature instrument implanted in chest telemeters information to external receiver-converter. System permits continual dimensional data recording taken from awake animals during long-term experiments.

Lee, R. D.↗

Heart simulator

Unijunction oscillator controlled by potentiometer to generate a spike that may be converted by transformer action to the simulated heart beat is used as a calibrator for heart monitoring equipment.

Palmer, E.↗

The heart sound preprocessor

Technology developed for signal and data processing was applied to diagnostic techniques in the area of phonocardiography (pcg), the graphic recording of the sounds of the heart generated by the functioning of the aortic and ventricular valves. The relatively broad bandwidth of the PCG signal (20 to 2000 Hz) was reduced to less than 100 Hz by the use of a heart sound envelope. The process involves full-wave rectification of the PCG signal, envelope detection of the rectified wave, and low pass filtering of the resultant envelope.

Chen, W. T.↗

Psychosocial factors in coronary heart disease

The relationship between job satisfaction and coronary heart disease is explored for blue and white collar groups, different personalities and physiological risk factors. Differences found among administrators, engineers and scientists with regard to variables associated with heart disease are in terms of physiology, personality, reported job stress, and smoking.

French, J. R. P., Jr.↗

Subminiature transducers for measuring forces and deformation of heart muscle

Two subminiature transducers, one measuring muscle forces and one measuring muscle displacement, can be inserted into heart muscle without interfering with it. Probe, approximately 1 mm (0.04 in), causes no damage to heart muscle. Probe can be rotated to different positions to measure muscle forces from various directions.

Feldstein, C.↗

Computer measurement and representation of the heart in two and three dimensions

Methods for the measurement and display by minicomputer of cardiac images obtained from fluoroscopy to permit an accurate assessment of functional changes are discussed. Heart contours and discrete points can be digitized automatically or manually, with the recorded image in a video, cine, or print format. As each frame is digitized it is assigned a code name identifying the data source, experiment, run, view, and frame, and the images are filed for future reference in any sequence. Two views taken at the same point in the heart cycle are used to compute the spatial position of the ventricle apex and the midpoint of the aortic valve. The remainder of the points on the chamber border are corrected for the linear distortion of the X-rays by projection to a plane containing the chord between the apex and the aortic valve center and oriented so that lines perpendicular to the chord are parallel to the image intensifier face. The image of the chamber surface is obtained by generating circular cross sections with diameters perpendicular to the major chord. The transformed two- and three-dimensional imagery can be displayed in either static or animated form using a graphics terminal.

Rasmussen, D.↗

Computer measurement and representation of the heart in two and three dimensions

Methods for accurate measurement and meaningful display of cardiac dimensions as obtained from fluoroscopy were surveyed. Recorded images were scaled back to actual dimensions and cardiac motion was displayed to assess functional changes. This was accomplished by use of a low-cost but flexible ensemble of computer and video equipment which assisted in (1) digitizing image outlines or points, (2) filing digitized images for later recall in any sequence, (3) correcting recorded images for distortion, (4) modeling heart geometry, (5) analyzing dimensional changes, and (6) displaying both heart geometry and results of analysis in a useful form.

Rasmussen, D.↗

Behavior patterns and coronary heart disease

The relationships between two behavioral patterns, cardiac risk factors, and coronary heart disease are investigated. Risk factors used in the analysis were family history of coronary disease, smoking, cholesterol, obesity, systotic blood pressure, diastolic blood pressure, blood sugar, uric acid, erythrocyte sedimentation rate, and white blood unit. It was found that conventional, non-behavioral pattern risk factors alone were not significantly related to coronary heart disease.

Townsend, J. C.↗

Perception of binary acoustic events associated with the first heart sound

The resolving power of the auditory apparatus permits discrete vibrations associated with cardiac activity to be perceived as one or more events. Irrespective of the vibratory combinations recorded by conventional phonocardiography, in normal adults and in most adult patients auscultators tend to discriminate only two discrete events associated with the first heart sound S1. It is stressed that the heart sound S4 may be present when a binary acoustic event associated with S1 occurs in the sequence 'low pitched sound preceding high pitched sound', i.e., its components are perceived by auscultation as 'dull-sharp'. The question of S4 audibility arises in those individuals, normal and diseased, in whom the major components of S1 ought to be, at least clinically, at their customary high pitch and indeed on the PCG appear as high frequency oscillations. It is revealed that the apparent audibility of recorded S4 is not related to P-R interval, P-S4 interval, or relative amplitude of S4. The significant S4-LFC (low frequency component of S1) differences can be related to acoustic modification of the early component of S1.

Spodick, D. H.↗

Combined use of autogenic therapy and biofeedback in training effective control of heart rate by humans

Experiments were performed on 24 men and women (aged 20-27 yr) in three equal groups who were taught to control their own heart rates by autogenic training and biofeedback under dark and sound-isolated conditions. Group I was parasympathetic dominant, group II was sympathetic dominant, and group III consisted of parasympathetic-dominant subjects and controls who received only biofeedback of their own heart rates. The results corroborate three hypotheses: (1) subjects with para-sympathetic-dominant autonomic profiles perform in a way that is both qualitatively and quantitatively different from subjects with sympathetic-dominant autonomic profiles; (2) tests of interindividual variability yield data relevant to individual performance in visceral learning tasks; and (3) the combined use of autogenic training, biofeedback, and verbal feedback is suitable for conditioning large stable autonomic responses in humans.

Cowings, P. S.↗