Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOSPITALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An update on Lab Rover: A hospital material transporter

The development of a hospital material transporter, 'Lab Rover', is described. Conventional material transport now utilizes people power, push carts, pneumatic tubes and tracked vehicles. Hospitals are faced with enormous pressure to reduce operating costs. Cyberotics, Inc. developed an Autonomous Intelligent Vehicle (AIV). This battery operated service robot was designed specifically for health care institutions. Applications for the AIV include distribution of clinical lab samples, pharmacy drugs, administrative records, x-ray distribution, meal tray delivery, and certain emergency room applications. The first AIV was installed at Lahey Clinic in Burlington, Mass. Lab Rover was beta tested for one year and has been 'on line' for an additional 2 years.

Mattaboni, Paul↗

Rotating shift work, sleep, and accidents related to sleepiness in hospital nurses

A hospital-based survey on shift work, sleep, and accidents was carried out among 635 Massachusetts nurses. In comparison to nurses who worked only day/evening shifts, rotators had more sleep/wake cycle disruption and nodded off more at work. Rotators had twice the odds of nodding off while driving to or from work and twice the odds of a reported accident or error related to sleepiness. Application of circadian principles to the design of hospital work schedules may result in improved health and safety for nurses and patients.

Non-NASA Center↗

Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients

PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding to a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repetitive Pediatric Anesthesia in a Non-Hospital Setting

Purpose: Repetitive sedation/anesthesia (S/A) for children receiving fractionated radiation therapy requires induction and recovery daily for several weeks. In the vast majority of cases, this is accomplished in an academic center with direct access to pediatric faculty and facilities in case of an emergency. Proton radiation therapy centers are more frequently free-standing facilities at some distance from specialized pediatric care. This poses a potential dilemma in the case of children requiring anesthesia. Methods and Materials: The records of the Indiana University Health Proton Therapy Center were reviewed for patients requiring anesthesia during proton beam therapy (PBT) between June 1, 2008, and April 12, 2012. Results: A total of 138 children received daily anesthesia during this period. A median of 30 fractions (range, 1-49) was delivered over a median of 43 days (range, 1-74) for a total of 4045 sedation/anesthesia procedures. Three events (0.0074%) occurred, 1 fall from a gurney during anesthesia recovery and 2 aspiration events requiring emergency department evaluation. All 3 children did well. One aspiration patient needed admission to the hospital and mechanical ventilation support. The other patient returned the next day for treatment without issue. The patient who fell was not injured. No patient required cessation of therapy. Conclusions: This is the largest reported series of repetitive pediatric anesthesia in radiation therapy, and the only available data from the proton environment. Strict adherence to rigorous protocols and a well-trained team can safely deliver daily sedation/anesthesia in free-standing proton centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Current Consensus Statement Recommendations for Accelerated Partial Breast Irradiation: A Pooled Analysis of William Beaumont Hospital and American Society of Breast Surgeon MammoSite Registry Trial Data

Purpose: To determine whether the American Society for Radiation Oncology (ASTRO) Consensus Statement (CS) recommendations for accelerated partial breast irradiation (APBI) are associated with significantly different outcomes in a pooled analysis from William Beaumont Hospital (WBH) and the American Society of Breast Surgeons (ASBrS) MammoSite® Registry Trial. Methods and Materials: APBI was used to treat 2127 cases of early-stage breast cancer (WBH, n=678; ASBrS, n=1449). Three forms of APBI were used at WBH (interstitial, n=221; balloon-based, n=255; or 3-dimensional conformal radiation therapy, n=206), whereas all Registry Trial patients received balloon-based brachytherapy. Patients were divided according to the ASTRO CS into suitable (n=661, 36.5%), cautionary (n=850, 46.9%), and unsuitable (n=302, 16.7%) categories. Tumor characteristics and clinical outcomes were analyzed according to CS group. Results: The median age was 65 years (range, 32-94 years), and the median tumor size was 10.0 mm (range, 0-45 mm). The median follow-up time was 60.6 months. The WBH cohort had more node-positive disease (6.9% vs 2.6%, P<.01) and cautionary patients (49.5% vs 41.8%, P=.06). The 5-year actuarial ipsilateral breast tumor recurrence (IBTR), regional nodal failure (RNF), and distant metastasis (DM) for the whole cohort were 2.8%, 0.6%, 1.6%. The rate of IBTR was not statistically higher between suitable (2.5%), cautionary (3.3%), or unsuitable (4.6%) patients (P=.20). The nonsignificant increase in IBTR for the cautionary and unsuitable categories was due to increased elsewhere failures and new primaries (P=.04), not tumor bed recurrence (P=.93). Conclusions: Excellent outcomes after breast-conserving surgery and APBI were seen in our pooled analysis. The current ASTRO CS guidelines did not adequately differentiate patients at an increased risk of IBTR or tumor bed failure in this large patient cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of failure mode and effects analysis to construct an effective disposal and prevention mechanism for infectious hospital waste

Highlights: > This study is based on a real case in a regional teaching hospital in Taiwan. > We use Failure mode and effects analysis (FMEA) as the evaluation method. > We successfully identify the risk factors of infectious waste disposal. > We propose plans for the detection of exceptional cases of infectious waste. - Abstract: In recent times, the quality of medical care has been continuously improving in medical institutions wherein patient-centred care has been emphasized. Failure mode and effects analysis (FMEA) has also been promoted as a method of basic risk management and as part of total quality management (TQM) for improving the quality of medical care and preventing mistakes. Therefore, a study was conducted using FMEA to evaluate the potential risk causes in the process of infectious medical waste disposal, devise standard procedures concerning the waste, and propose feasible plans for facilitating the detection of exceptional cases of infectious waste. The analysis revealed the following results regarding medical institutions: (a) FMEA can be used to identify the risk factors of infectious waste disposal. (b) During the infectious waste disposal process, six items were scored over 100 in the assessment of uncontrolled risks: erroneous discarding of infectious waste by patients and their families, erroneous discarding by nursing staff, erroneous discarding by medical staff, cleaning drivers pierced by sharp articles, cleaning staff pierced by sharp articles, and unmarked output units. Therefore, the study concluded that it was necessary to (1) provide education and training about waste classification to the medical staff, patients and their families, nursing staff, and cleaning staff; (2) clarify the signs of caution; and (3) evaluate the failure mode and strengthen the effects.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiotherapy and Nuclear Medicine Project for an Integral Oncology Center at the Oaxaca High Specialization Regional Hospital

A building project of Radiotherapy and Nuclear Medicine services (diagnostic and therapy), within an Integral Oncology Center (IOC), requires interdisciplinary participation of architects, biomedical engineers, radiation oncologists and medical physicists. This report focus on the medical physicist role in designing, building and commissioning stages, for the final clinical use of an IOC at the Oaxaca High Specialization Regional Hospital (HRAEO). As a first step, during design stage, the medical physicist participates in discussions about radiation safety and regulatory requirements for the National Regulatory Agency (called CNSNS in Mexico). Medical physicists propose solutions to clinical needs and take decisions about installing medical equipment, in order to fulfill technical and medical requirements. As a second step, during the construction stage, medical physicists keep an eye on building materials and structural specifications. Meanwhile, regulatory documentation must be sent to CNSNS. This documentation compiles information about medical equipment, radioactivity facility, radiation workers and nuclear material data, in order to obtain the license for the linear accelerator, brachytherapy and nuclear medicine facilities. As a final step, after equipment installation, the commissioning stage takes place. As the conclusion, we show that medical physicists are essentials in order to fulfill with Mexican regulatory requirements in medical facilities.

07 ISOTOPE AND RADIATION SOURCES↗

An indoor radon survey of the X-ray rooms of Mexico City hospitals

This paper presents the results of measurements of indoor radon concentrations in the X-ray rooms of a selection of hospitals in the metropolitan area of Mexico City. The metropolitan area of Mexico City is Mexico's largest metropolitan area by population; the number of patients requiring the use of X-rays is also the highest. An understanding of indoor radon concentrations in X-ray rooms is necessary for the estimation of the radiological risk to which patients, radiologists and medical technicians are exposed. The indoor radon concentrations were monitored for a period of six months using nuclear track detectors (NTD) consisting of a closed-end cup system with CR-39 (Lantrack Registered-Sign ) polycarbonate as detector material. The indoor radon concentrations were found to be between 75 and 170 Bq m{sup -3}, below the USEPA-recommended indoor radon action level for working places of 400 Bq m{sup -3}. It is hoped that the results of this study will contribute to the establishment of recommended action levels by the Mexican regulatory authorities responsible for nuclear safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-317: The Development of a DIBH Technique for Left Sided Breast Patients Undergoing Radiation Therapy Utilizing Varians RPM System in a Community Hospital

Purpose: To develop and implement a Deep Inhalation Breath Hold program (DIBH) for treatment of patients with Left-sided breast cancer in a community hospital. Methods: All patients with left sided breast cancer underwent a screening free breathing CT. Evaluation of the conventional tangent treatment fields and the heart was conducted. If the heart would not be excluded using tangents, the patient then received DIBH breathe coaching. The patients returned for a 4D CT simulation. The patients breathing cycle was monitored using the Varian Real-Time position ManagementTM (RPM) system to assess duration of DIBH, amplitude, phase and recovery time to normal breathing. Then a DIBH CT was obtained at the desired amplitude. Duplicate plans were developed for both free breathing and DIBH on the Eclipse planning system and comparison DVH's were created. The plan that provided the prescribed treatment coverage and the least doses to the OAR (heart, Lt. Lung) was determined. Those patients selected to receive treatment with DIBH were set up for treatment, and breathing was monitored using the RPM system. Practice trials were used to confirm that the amplitude, phase and recovery were consistent with findings from simulation. Results: 10 patients have been treated using the DIBH procedure in our clinic. The DIBH patients had an average increase of 80% lung volume on DIBH, decreased lung volume receiving 50% of the dose, and decreases in the V20 dose. Significant reduction in the maximum and mean dose to the heart, as well as the dose to 1CC of the volume for the DIBH plans. Conclusion: Using the RPM system already available in the clinic, staff training, and patient coaching a simple DIBH program was setup. The use of DIBH has shown promise in reducing doses to the critical organs while maintaining PTV coverage for left sided breast treatments.

60 APPLIED LIFE SCIENCES↗

Lighting Control in Patient Rooms: Understanding Nurses’ Perceptions of Hospital Lighting Using Qualitative Methods

Here, this study differs in its methodological approach from previously published research by interpreting qualitative results against existing literature to understand how nurses conceptualize medical–surgical patient rooms as productive settings in relation to lighting, as well as the ways in which nurses believe these spaces could be enhanced for patient satisfaction. Content analysis was used to interpret themes emerging from nurses’ subjective responses to open-ended items. Three of the facilities had older, traditional lighting systems; one had a contemporary framework. A theme of environmental control over both overhead and task lighting emerged from data from all items. Although controllability was among the “best” lighting attributes, more refinement is necessary for optimal staff productivity and patient satisfaction. Daylighting was also considered to be among the best attributes. Control over light level via additional dimming capability for patients, as well as additional light sources, was prominent across the four hospitals. Unique to the more modern facility, trespassing of light was problematic for nurses considering the experiences of patients—even where modern models exist, more attention can be paid to the ways in which window shades, and light sources outside of rooms, penetrate spaces and affect users. Finally, the finding that nurses and patients desire greater control over the lighting in patient rooms is consistent with Ulrich’s theory of supportive design for healthcare and coincides with advances in lighting technology. Despite differences in the level of sophistication in lighting among the four facilities, control continues to be a primary concern for nurses.

60 APPLIED LIFE SCIENCES↗

Evidence of SV40 infections in hospitalized children

Simian virus 40 (SV40) is known to have contaminated poliovirus vaccines used between 1955 and 1963. Accumulating reports have described the presence of SV40 DNA in human tumors and normal tissues, although the significance of human infections by SV40 is unknown. We investigated whether unselected hospitalized children had evidence of SV40 infections and whether any clinical correlations were apparent. Serum samples were examined for SV40 neutralizing antibody using a specific plaque reduction test; of 337 samples tested, 20 (5.9%) had antibody to SV40. Seropositivity increased with age and was significantly associated with kidney transplants (6 of 15 [40%] positive, P < .001). Many of the antibody-positive patients had impaired immune systems. Molecular assays (polymerase chain reaction and DNA sequence analysis) on archival tissue specimens confirmed the presence of SV40 DNA in 4 of the antibody-positive patients. This study, using 2 independent assays, shows the presence of SV40 infections in children born after 1980. We conclude that SV40 causes natural infections in humans.

NASA Discipline Regulatory Physiology↗