Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYGROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SPADE H2O measurements and the seasonal cycle of statospheric water vapor

We present measurements of lower statospheric water vapor obtained during the Stratospheric Phototchemistry, Aerosols and Dynamics Expedition (SPADE) mission with a new high precision, fast response, Lyman-alpha hygrometer. The H2O data show a distinct seasonal cycle. For air that recently entered the statosphere, data collected during the fall show much more water vapor than data from the spring. Fast quasi-horizontal mixing causes compact relationships between water and N2O to be established on relatively short time scales. The measurements are consistent with horizontal mixing times of a few months or less. Vertical mixing appears to cause the seasonal variations in water vapor to propagate up to levels corresponding to air that has been in the stratosphere approximately one year.

Hintsa, Eric J.↗

Airborne differential absorption lidar system for measurements of atmospheric water vapor and aerosols

An airborne differential absorption lidar (DIAL) system has been developed at the NASA Langley Research Center for remote measurements of atmospheric water vapor (H2O) and aerosols. A solid-state alexandrite laser with a 1-pm linewidth and greater than 99.85% spectral purity was used as the on-line transmitter. Solid-state avalanche photodiode detector technology has replaced photomultiplier tubes in the receiver system, providing an average increase by a factor of 1.5-2.5 in the signal-to-noise ratio of the H2O measurement. By incorporating advanced diagnostic and data-acquisition instrumentation into other subsystems, we achieved additional improvements in system operational reliability and measurement accuracy. Laboratory spectroscopic measurements of H2O absorption-line parameters were performed to reduce the uncertainties in our knowledge of the absorption cross sections. Line-center H2O absorption cross sections were determined, with errors of 3-6%, for more than 120 lines in the 720-nm region. Flight tests of the system were conducted during 1989-1991 on the NASA Wallops Flight Facility Electra aircraft, and extensive intercomparison measurements were performed with dew-point hygrometers and H2O radiosondes. The H2O distributions measured with the DIAL system differed by less than 10% from the profiles determined with the in situ probes in a variety of atmospheric conditions.

Carter, Arlen F.↗

Field Micrometeorological Measurements, Process-Level Studies and Modeling of Methane and Carbon Dioxide Fluxes in a Boreal Wetland Ecosystem

The main instrumentation platform consisted of eddy correlation sensors mounted on a scaffold tower at a height of 4.2 m above the peat surface. The sensors were attached to a boom assembly which could be rotated into the prevailing winds. The boom assembly was mounted on a movable sled which, when extended, allowed sensors to be up to 2 m away from the scaffolding structure to minimize flow distortion. When retracted, the sensors could easily be installed, serviced or rotated. An electronic level with linear actuators allowed the sensors to be remotely levelled once the sled was extended. Two instrument arrays were installed. A primary (fast-response) array consisted of a three-dimensional sonic anemometer, a methane sensor (tunable diode laser spectrometer), a carbon dioxide/water vapor sensor, a fine wire thermocouple and a backup one-dimensional sonic anemometer. The secondary array consisted of a one-dimensional sonic anemometer, a fine wire thermocouple and a Krypton hygrometer. Descriptions of these sensors may be found in other reports (e.g., Verma; Suyker and Verma). Slow-response sensors provided supporting measurements including mean air temperature and humidity, mean horizontal windspeed and direction, incoming and reflected solar radiation, net radiation, incoming and reflected photosynthetically active radiation (PAR), soil heat flux, peat temperature, water-table elevation and precipitation. A data acquisition system (consisting of an IBM compatible microcomputer, amplifiers and a 16 bit analog-to-digital converter), housed in a small trailer, was used to record the fast response signals. These signals were low-pass filtered (using 8-pole Butterworth active filters with a 12.5 Hz cutoff frequency) and sampled at 25 Hz. Slow-response signals were sampled every 5 s using a network of CR21X (Campbell Scientific, Inc., Logan Utah) data loggers installed in the fen. All signals were averaged over 30-minute periods (runs).

Verma, S. B.↗

LASE validation experiment: preliminary processing of relative humidity from LASE derived water vapor in the middle to upper troposphere

Lidar Atmospheric Sensing Experiment (LASE) is the first fully engineered, autonomous airborne DIAL (Differentials Absorption Lidar) system to measure water vapor, aerosols, and clouds throughout the troposphere. This system uses a double-pulsed Ti:sapphire laser, which is pumped by a frequency-doubled flashlamp-pumped Nd: YAG laser, to transmit light in the 815 mn absorption band of water vapor. LASE operates by locking to a strong water vapor line and electronically tuning to any spectral position on the absorption line to choose the suitable absorption cross-section for optimum measurements over a range of concentrations in the atmosphere. During the LASE Validation Experiment, which was conducted over Wallops Island during September, 1995, LASE operated on either the strong water line for measurements in middle to upper troposphere, or on the weak water line for measurements made in the middle to lower troposphere including the boundary layer. Comparisons with water vapor measurements made by airborne dew point and frost point hygrometers, NASA/GSFC (Goddard Space Flight Center) Raman Lidar, and radiosondes showed the LASE water vapor mixing ratio measurements to have an accuracy of better than 6% or 0.01 g/kg, whichever is larger, throughout the troposphere. In addition to measuring water vapor mixing ratio profiles, LASE simultaneously measures aerosol backscattering profiles at the off-line wavelength near 815 nm from which atmospheric scattering ratio (ASR) profiles are calculated. ASR is defined as the ratio of total (aerosol + molecular) atmospheric scattering to molecular scattering. Assuming a region with very low aerosol loading can be identified, such as that typically found just below the tropopause, then the ASR can be determined. The ASR profiles are calculated by normalizing the scattering in the region containing enhanced aerosols to the expected scattering by the "clean" atmosphere at that altitude. Images of the total ASR clearly depict cloud regions, including multiple cloud layers, thin upper level cirrus, etc., throughout the troposphere. New data products that are being derived from the LASE aerosol and water measurements include: 1) aerosol extinction coefficient, 2) aerosol optical thickness, 3) precipitable water vapor, and 4) relative humidity (RH). These products can be compared with airborne in-situ, and ground and satellite remote sensing measurements,. This paper presents a preliminary examination of RH profiles in the middle to upper troposphere that are generated from LASE measured water vapor mixing ratio profiles coupled with rawinsonde profiles of temperature and pressure.

Brackett, Vincent G.↗

In Situ Instruments: Overview of In Situ Instruments for Deployment in Extreme Environments

This presentation reviews the design and specifications for several instruments for deployment in extreme environments. The instruments are: (1) In Situ Geochronology Instrument, (2) Laser Ablation Sampling Instrument, (3) Micro Hygrometer (4) Micro Lidar, (5) Atmospheric Electron X-Ray Spectrometer and (6) Nuclear Magnetic Resonance Spectrometer. Included in the descriptions are the contact people and the objective of each instrument.

Taylor, M.↗

Vertical Mass, Momentum, Moisture, and Heat Fluxes in Hurricanes above 10 km during CAMEX-3 and CAMEX-4

The third and fourth NASA Convection and Moisture Experiments (CAMEX-3 and CAMEX-4) during the Atlantic hurricane seasons of 1998 and 2001, respectively, have yielded comprehensive multi-aircraft datasets using, both remote and in-situ instrumentation. Among these are high-frequency in-situ measurements of vertical wind, horizontal wind, temperature, and water vapor, made from NASA's DC-8 aircraft in the upper portions of the hurricane (typically above 10 km). Wind and temperature measurements were made at 20 hz by the NASA/Ames Meteorological Measurement System, while water vapor was measured at 1 hz by the NASA/JPL Laser Hygrometer. Fluxes of heat, momentum, and moisture at these levels are important, since modeling studies have shown that ice processes, which are dominant at temperatures below -40C (where the DC-8 flies) are important for hurricane intensification. Also, there are indications from satellite studies that latent heat release at DC-8 levels is significant, perhaps a third of those in the mid-troposphere. Preliminary results show that typical updrafts in the eyewall region are comparable to or higher than previous observations of tropical convection, with several instances of updraft magnitudes of 15 meters per second (the maximum observed was 21 meters per second). They also show significant supersaturations (10-20% or more) in the updrafts, which would enhance the latent heat release at the upper levels of the hurricane. This paper will examine the magnitude and distribution of small and mesoscale vertical fluxes of mass, momentum, moisture, and heat. The goal is to examine the role of these fluxes in the overall budgets of the respective quantities in the upper portions of the hurricane.

Pfister, Leonhard↗

Airborne Sunphotometer Measurements of Aerosol Optical Depth and Columnar Water Vapor During the Puerto Rico Dust Experiment, and Comparison with Land, Aircraft, and Satellite Measurements

Analyses of aerosol optical depth (AOD) and columnar water vapor (CWV) measurements obtained with the six-channel NASA Ames Airborne Tracking Sunphotometer (AATS-6) mounted on a twin-engine aircraft during the summer 2000 Puerto Rico Dust Experiment are presented. In general, aerosol extinction values calculated from AATS-6 AOD measurements acquired during aircraft profiles up to 5 km ASL reproduce the vertical structure measured by coincident aircraft in-situ measurements of total aerosol number and surface area concentration. Calculations show that the spectral dependence of AOD was small (mean Angstrom wavelength exponents of approximately 0.20) within three atmospheric layers defined as the total column beneath the top of each aircraft profile, the region beneath the trade wind inversion, and the region within the Saharan Air Layer (SAL) above the trade inversion. This spectral behavior is consistent with attenuation of incoming solar radiation by large dust particles or by dust plus sea salt. Values of CWV calculated from profile measurements by AATS-6 at 941.9 nm and from aircraft in-situ measurements by a chilled mirror dewpoint hygrometer agree to within approximately 4% (0.13 g/sq cm). AATS-6 AOD values measured on the ground at Roosevelt Roads Naval Air Station and during low altitude aircraft runs over the adjacent Cabras Island aerosol/radiation ground site agree to within 0.004 to 0.030 with coincident data obtained with an AERONET Sun/sky Cimel radiometer located at Cabras Island. For the same observation times, AERONET retrievals of CWV exceed AATS-6 values by a mean of 0.74 g/sq cm (approximately 21 %) for the 2.9-3.9 g/sq cm measured by AATS-6. Comparison of AATS-6 aerosol extinction values obtained during four aircraft ascents over Cabras Island with corresponding values calculated from coincident aerosol backscatter measurements by a ground-based micro-pulse lidar (MPL-Net) located at Cabras yields a similar vertical structure above the trade inversion. Finally, AATS-6 AOD values measured during low altitude aircraft traverses over the ocean are compared with corresponding AOD values retrieved over water from upwelling radiance measurements by the MODIS, TOMS, and GOES-8 Imager satellite sensors, with mixed results. These exercises highlight the need for continued satellite sensor comparison/validation studies to improve satellite AOD retrieval algorithms, and the usefulness of airborne sunphotometer measurements in the validation process.

Livingston, John M.↗

Characterization of Upper Troposphere Water Vapor Measurements during AFWEX using LASE

Water vapor profiles from NASA's Lidar Atmospheric Sensing Experiment (LASE) system acquired during the ARM/FIRE Water Vapor Experiment (AFWEX) are used to characterize upper troposphere water vapor (UTWV) measured by ground-based Raman lidars, radiosondes, and in situ aircraft sensors. Initial comparisons showed the average Vaisala radiosonde measurements to be 5-15% drier than the average LASE, Raman lidar, and DC-8 in situ diode laser hygrometer measurements. We show that corrections to the Raman lidar and Vaisala measurements significantly reduce these differences. Precipitable water vapor (PWV) derived from the LASE water vapor profiles agrees within 3% on average with PWV derived from the ARM ground-based microwave radiometer (MWR). The agreement among the LASE, Raman lidar, and MWR measurements demonstrates how the LASE measurements can be used to characterize both profile and column water vapor measurements and that ARM Raman lidar, when calibrated using the MWR PWV, can provide accurate UTWV measurements.

Ferrare, R. A.↗

[Measurements of "Total Water" and Carbon Dioxide from the NASA WB-57 During Crystal-Face]

An existing closed-path tunable diode laser hygrometer (CLH) was employed for the measurements of total water made during CRYSTAL-FACE. This instrument had flown previously on the NASA DC-8 during the SAGE III Ozone Loss and Validation Experiment (SOLVE) and also on the NCAR C-130 during some local flights designed to test the extent of water vapor interference in carbon dioxide measurements. The instrument was largely unchanged from previous studies, but a new inlet appropriate to the WB-57F wingpod was constructed. In order to minimize the impact on the over-subscribed right wingpod and to achieve good thermal control of the inlet temperature, the CLH inlet was made of carbon-fiber/epoxy composite. Considerable effort was spent to design and build the lightest possible mounting hardware and design relatively low-power inlet heaters. As a result, the instrument and mounting hardware came in below the NASA/JSC-imposed weight cap of 35 lbs. Data were obtained on all test flights during May 2002 and during all but one mission flight in July 2002 (the one lost flight was due to an unplugged instrument power cable). Instrument performance during the test flights was good, but the data are not science- quality, as a variety of tests were performed to optimize the inlet configuration and heating. Data on all mission flights is of high quality, despite some difficulties caused by flying through wet low-altitude air masses and dense anvils, which saturated the instrument response.

Avallone, Linnea M.↗

Measurements of the Ice Water Content of Cirrus in the Tropics and Subtropics: Instrument Details and Validation - I

We describe an instrument mounted in a pallet on the NASA WB-57 aircraft that is designed to measure the sum of gas phase and solid phase water, or total water, in cirrus clouds. Using an isokinetic inlet, a 600-watt heater mounted directly in the flow, and Lyman-alpha photofragment fluorescence technique for detection, accurate measurements of total water have been made over almost three orders of magnitude. Isokinetic flow is achieved with an actively controlled roots pump by referencing aircraft pressure, temperature, and true air speed, together with instrument flow velocity, temperature, and pressure. During CRYSTAL FACE, the instrument operated at duct temperatures sufficiently warm to completely evaporate particles up to 150 microns diameter. In flight diagnostics, intercomparison with water measured by absorption in flight, as well as intercomparisons in clear air with water vapor measured by the Harvard water vapor instrument and the JPL infrared tunable diode laser hygrometer validate the detection sensitivity of the instrument and illustrate minimal hysteresis from instrument surfaces. The simultaneous measurement of total water and water vapor in cirrus clouds yields their ice water content.

Weinstock, E. M.↗

Analysis of Raman Lidar and radiosonde measurements from the AWEX-G field campaign and its relation to Aqua validation

Early work within the Aqua validation activity revealed there to be large differences in water vapor measurement accuracy among the various technologies in use for providing validation data. The validation measurements were made at globally distributed sites making it difficult to isolate the sources of the apparent measurement differences among the various sensors, which included both Raman lidar and radiosonde. Because of this, the AIRS Water Vapor Experiment-Ground (AWEX-G) was held in October - November, 2003 with the goal of bringing validation technologies to a common site for intercomparison and resolution of the measurement discrepancies. Using the University of Colorado Cryogenic Frostpoint Hygrometer (CFH) as the water vapor reference, the AWEX-G field campaign resulted in new correction techniques for both Raman lidar, Vaisala RS80-H and RS90/92 measurements that significantly improve the absolute accuracy of those measurement systems particularly in the upper troposphere. Mean comparisons of radiosondes and lidar are performed demonstrating agreement between corrected sensors and the CFH to generally within 5% thereby providing data of sufficient accuracy for Aqua validation purposes. Examples of the use of the correction techniques in radiance and retrieval comparisons are provided and discussed.

Whiteman, D. N.↗

Analysis of Raman Lidar and Radiosonde Measurements from the AWEX-G Field Campaign and Its Relation to Aqua Validation

Early work within the Aqua validation activity revealed there to be large differences in water vapor measurement accuracy among the various technologies in use for providing validation data. The validation measurements were made at globally distributed sites making it difficult to isolate the sources of the apparent measurement differences among the various sensors, which included both Raman lidar and radiosonde. Because of this, the AIRS Water Vapor Experiment-Ground (AWEX-G) was held in October-November 2003 with the goal of bringing validation technologies to a common site for intercomparison and resolving the measurement discrepancies. Using the University of Colorado Cryogenic Frostpoint Hygrometer (CFH) as the water vapor reference, the AWEX-G field campaign permitted correction techniques to be validated for Raman lidar, Vaisala RS80-H and RS90/92 that significantly improve the absolute accuracy of water vapor measurements from these systems particularly in the upper troposphere. Mean comparisons of radiosondes and lidar are performed demonstrating agreement between corrected sensors and the CFH to generally within 5% thereby providing data of sufficient accuracy for Aqua validation purposes. Examples of the use of the correction techniques in radiance and retrieval comparisons are provided and discussed.

Whiteman, D. N.↗

Trace water sensor

A solid electrolytic type hygrometer is described, which operates with high reliability while providing rapid and sensitive response. A gold foil electrode (16) is wrapped about a hollow glass cylinder (18), a sheet (12) of hygroscopic-electrolytic material is wrapped about the foil, and a wire (14) is wound around the outside of the electrolytic sheet. Moisture passing between wire turns can be absorbed by the electrolytic material (12), and then dissociated by current passed by the electrodes (14, 16) through the electrolytic material. The cylinder has a slit (20) extending along its length, to allow resilient expansion to press the sheet of electrolytic material firmly against the electrodes. The wire turns lie against one another to cause rapid dissociation of moisture throughout the electrolytic material. Additional guard wires (42,44, FIG. 2) lie at opposite ends of the electrolytic sheet, and currents pass through them to avoid moisture buildup at the ends of the main wire coil. The electrical current through the sheet or membrane is proportional to the partial pressure of the water-vapor.

Stephens, James B.↗

Accuracy Assessment and Correction of Vaisala RS92 Radiosonde Water Vapor Measurements

Relative humidity (RH) measurements from Vaisala RS92 radiosondes are widely used in both research and operational applications, although the measurement accuracy is not well characterized as a function of its known dependences on height, RH, and time of day (or solar altitude angle). This study characterizes RS92 mean bias error as a function of its dependences by comparing simultaneous measurements from RS92 radiosondes and from three reference instruments of known accuracy. The cryogenic frostpoint hygrometer (CFH) gives the RS92 accuracy above the 700 mb level; the ARM microwave radiometer gives the RS92 accuracy in the lower troposphere; and the ARM SurTHref system gives the RS92 accuracy at the surface using 6 RH probes with NIST-traceable calibrations. These RS92 assessments are combined using the principle of Consensus Referencing to yield a detailed estimate of RS92 accuracy from the surface to the lowermost stratosphere. An empirical bias correction is derived to remove the mean bias error, yielding corrected RS92 measurements whose mean accuracy is estimated to be +/-3% of the measured RH value for nighttime soundings and +/-4% for daytime soundings, plus an RH offset uncertainty of +/-0.5%RH that is significant for dry conditions. The accuracy of individual RS92 soundings is further characterized by the 1-sigma "production variability," estimated to be +/-1.5% of the measured RH value. The daytime bias correction should not be applied to cloudy daytime soundings, because clouds affect the solar radiation error in a complicated and uncharacterized way.

Whiteman, David N.↗

Radiation Dry Bias of the Vaisala RS92 Humidity Sensor

The comparison of simultaneous humidity measurements by the Vaisala RS92 radiosonde and by the Cryogenic Frostpoint Hygrometer (CFH) launched at Alajuela, Cosla Rica, during July 2005 reveals a large solar radiation dry bias of the Vaisala RS92 humidity sensor and a minor temperature-dependent calibration error. For soundings launched at solar zenith angles between 10" and 30 , the average dry bias is on the order of 9% at the surface and increases to 50% at 15 km. A simple pressure- and temperature-dependent correction based on the comparison with the CFH can reduce this error to less than 7% at all altitudes up to 15.2 km, which is 700 m below the tropical tropopause. The correction does not depend on relative humidity, but is able to reproduce the relative humidity distribution observed by the CFH.

Vomel, H.↗

Measurements of Humidity in the Atmosphere and Validation Experiments (Mohave, Mohave II): Results Overview

The Measurements of Humidity in the Atmosphere and Validation Experiments (MOHAVE, MOHAVE-II) inter-comparison campaigns took place at the Jet Propulsion Laboratory (JPL) Table Mountain Facility (TMF, 34.5(sup o)N) in October 2006 and 2007 respectively. Both campaigns aimed at evaluating the capability of three Raman lidars for the measurement of water vapor in the upper troposphere and lower stratosphere (UT/LS). During each campaign, more than 200 hours of lidar measurements were compared to balloon borne measurements obtained from 10 Cryogenic Frost-point Hygrometer (CFH) flights and over 50 Vaisala RS92 radiosonde flights. During MOHAVE, fluorescence in all three lidar receivers was identified, causing a significant wet bias above 10-12 km in the lidar profiles as compared to the CFH. All three lidars were reconfigured after MOHAVE, and no such bias was observed during the MOHAVE-II campaign. The lidar profiles agreed very well with the CFH up to 13-17 km altitude, where the lidar measurements become noise limited. The results from MOHAVE-II have shown that the water vapor Raman lidar will be an appropriate technique for the long-term monitoring of water vapor in the UT/LS given a slight increase in its power-aperture, as well as careful calibration.

lidar↗

STROZ Lidar Results at the MOHAVE III Campaign, October, 2009, Table Mountain, CA

During October, 2009 the GSFC STROZ Lidar participated in a campaign at the JPL Table Mountain Facility (Wrightwood, CA, 2285 m Elevation) to measure vertical profiles of water vapor from near the ground to the lower stratosphere. On eleven nights, water vapor, aerosol, temperature and ozone profiles were measured by the STROZ lidar, two other similar lidars, frost-point hygrometer sondes, and ground-based microwave instruments made measurements. Results from these measurements and an evaluation of the performance of the STROZ lidar during the campaign will be presented in this paper. The STROZ lidar was able to measure water vapor up to 13-14 km ASL during the campaign. We will present results from all the STROZ data products and comparisons with other instruments made. Implications for instrumental changes will be discussed.

McGee, T. J.↗

The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

Selkirk, Henry B.↗