Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA's Ground Test Unit (GTU) Lunar Terrain Vehicle (LTV) Conceptual Hand Controllers Studies

Over that past year, the National Aeronautics and Space Administration (NASA) has been preparing and developing a set of standardized testing protocols for the commercial LTV vendor selection. Two studies have been conducted on two possible hand controller concepts specifically designed for the operation of NASA’s Ground Test Unit (GTU) Lunar Terrain Vehicle (LTV) that can be applied to the heretofore unknown designs developed by future LTV vendors. The objective for the two studies were to determine which hand controller enable acceptable operation of the LTV in a simulated lunar traverse. In the first evaluation a total of nine subjects in shirtsleeves with ungloved hands performed two simulated lunar driving courses in an engineering simulator with each hand controller. Controller concept one was the T-handle fashioned after the Apollo Lunar Roving Vehicle’s (LRV) T-Handle controller. The rational for using this design is it’s a proven design while in a pressurized suit. However, the LTV does have a driving mode the LRV did not consider. The mode of crabbing or strafing the vehicle at different angles; thus, the idea of a dual T-Handle controllers to accommodate this function without using a switch or display was introduced. The second concept controller is a new innovative controller call the Tri-Rotor [NASA patent review MSC-27385-1]. Inspired by Formula One race steering, the Tri-Rotor was designed to take advantage of the restricted movement and dexterity of a pressurized space suit. During testing, all subjects were able to successfully navigate through two test courses of varying lengths and complexity. Results indicated the dual Thandle had minimal recommendations for improvement while the Tri-Rotor had more extensive ones. It must be noted, the Tri-Rotor is a first-generation prototype and has some known mechanical concerns; thus, recommendations from this study will be incorporated into the second generation.

Human Factors↗

Application of a headspace GC–MS method to evaluate the product quality of alcohol‐based hand wipe sanitizers

Abstract The investigation of marketed hand wipe sanitizers presented an analytical challenge owing to the need for extraction from the solid matrix of the products. The present work describes the development of a new sample preparation method for the extraction of analytes from the hand wipe sanitizer matrix into dimethyl sulfoxide for analysis using headspace GCMS. Alcohol‐based hand sanitizer (ABHS) wipe products labeled to contain ethanol or isopropanol as active ingredients were tested, varying in the size and weight of the wipes. The spike recovery assay was confirmed using spiking solutions containing impurities at concentrations equivalent to 50, 100 and 200% of the interim concentration limits. All of the tested analytes showed recovery within the allowable limits (80–120%). Six marketed ABHS wipe products were tested and no impurities above the FDA interim limits were observed. One product contained ethanol below the 60% v/v limit and another product was mislabeled for isopropanol and was found to contain ethanol instead. Four of the six ABHS products did not meet the label claim, which may affect the product quality. The analytical method and sample preparation procedures will provide the FDA and ABHS manufacturers with the capability to conduct quality assurance testing of hand wipe sanitizers for active ingredient content and impurities.

Biochemistry & Molecular Biology↗

Right-handed charged currents in the era of the Large Hadron Collider

We discuss the phenomenology of right-handed charged currents in the frame-work of the Standard Model Effective Field Theory, in which they arise due to a single gauge-invariant dimension-six operator. We study the manifestations of the nine complex couplings of the W to right-handed quarks in collider physics, flavor physics, and low-energy precision measurements. We first obtain constraints on the couplings under the assumption that the right-handed operator is the dominant correction to the Standard Model at observable energies. Here, we subsequently study the impact of degeneracies with other Beyond-the-Standard-Model effective interactions and identify observables, both at colliders and low-energy experiments, that would uniquely point to right-handed charged currents.

43 PARTICLE ACCELERATORS↗

Sclerotherapy of Diffuse and Infiltrative Venous Malformations of the Hand and Distal Forearm

PurposeVenous malformations (VM) involving the hand and forearm often lead to chronic pain and dysfunction, and the threshold for treatment is high due to the risk of nerve and skin damage, functional deterioration and compartment syndrome. The purpose of this study is to demonstrate that sclerotherapy of diffuse and infiltrative VM of the hand is a safe and effective therapy.Materials and MethodsA retrospective review of all patients with diffuse and infiltrative VM of the hand and forearm treated with sclerotherapy from 2001 to 2014 was conducted. All VM were diagnosed during the clinical visit by a combination of physical examination and imaging. Sclerotherapy was performed under imaging guidance using ethanol and/or sodium tetradecyl sulfate foam. Clinical notes were reviewed for signs of treatment response and complications, including skin blistering and nerve injury.ResultsSeventeen patients underwent a total of 40 sclerotherapy procedures. Patients were treated for pain (76 %), swelling (29 %) or paresthesias (6 %). Treatments utilized ethanol (70 %), sodium tetradecyl sulfate foam (22.5 %) or a combination of these (7.5 %). Twenty-four percent of patients had complete resolution of symptoms, 24 % had partial relief of symptoms without need for further intervention, and 35 % had some improvement after initial treatment but required additional treatments. Two skin complications were noted, both of which resolved. No motor or sensory loss was reported.ConclusionSclerotherapy is a safe and effective therapy for VM of the hand with over 83 % of patients experiencing relief.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel calcium recognition constructions in proteins: Calcium blade and EF-hand zone

Metal ions can regulate various cell processes being first, second or third messengers, and some of them, especially transition metal ions, take part in catalysis in many enzymes. As an intracellular ion, Ca{sup 2+} is involved in many cellular functions from fertilization and contraction, cell differentiation and proliferation, to apoptosis and cancer. Here, we have identified and described two novel calcium recognition environments in proteins: the calcium blade zone and the EF-hand zone, common to 12 and 8 different protein families, respectively. Each of the two environments contains three distinct structural elements: (a) the well-known characteristic Dx[DN]xDG motif; (b) an adjacent structurally identical segment, which binds metal ion in the same way between the calcium blade zone and the EF-hand zone; and (c) the following structurally variable segment, which distinguishes the calcium blade zone from the EF-hand zone. Both zones have sequence insertions between the last residue of the zone and calcium-binding residues in positions V or VI. The long insertion often connects the active and the calcium-binding sites in proteins. Using the structurally identical segments as an anchor, we were able to construct the classical calmodulin type EF-hand calcium-binding site out of two different calcium-binding motifs from two unrelated proteins.

60 APPLIED LIFE SCIENCES↗

Single-handed helical carbonaceous nanotubes prepared using a pair of cationic low molecular weight gelators

Highlights: • 3-aminophenol-formaldeyde resins were prepared through a templating method. • A pair of cationic gelators have been used as the templates. • Single-handed helical carbonaceous nanotubes were obtained after carbonization. • The carbonaceous nanotubes showed optical activity. - Abstract: We design a facile route to obtain enantiopure carbonaceous nanostructures, which have potential application as chiral sensors, electromagnetic wave absorbers, and asymmetric catalysts. A pair of cationic low molecular weight gelators was synthesized, which were able to self-assemble into twisted nanoribbons in ethanol at a concentration of 20 g L{sup −1} at 25 °C. Single-handed helical 3-aminophenol-formaldehyde resin nanotubes with optical activity were prepared using the self-assembly of the low molecular weight gelators as templates. After carbonization, single-handed helical carbonaceous nanotubes were obtained and characterized using circular dichroism, wide-angle X-ray diffraction, field-emission scanning electron microscopy, transmission electron microscopy, and Raman spectroscopy. The results indicate that the walls of the nanotubes are amorphous carbon. Moreover, the left- and right-handed helical nanotubes exhibit opposite optical activity.

36 MATERIALS SCIENCE↗

Quasi-phase-matching of the dual-band nonlinear left-handed metamaterial

We demonstrate a type of nonlinear meta-atom creating a dual-band nonlinear left-handed metamaterial (DNLHM). The DNLHM operates at two distinct left-handed frequency bands where there is an interval of one octave between the two center frequencies. Under the illumination of a high-power signal at the first left-handed frequency band corresponding to fundamental frequency (FF), second-harmonic generation (SHG) is observed at the second left-handed band. This means that our DNLHM supports backward-propagating waves both at FF and second-harmonic (SH) frequency. We also experimentally demonstrate quasi-phase-matching configurations for the backward SHG. This fancy parametric process can significantly transmits the SH generated by an incident FF wave.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Therapeutic hand-exercising device with cycling pressure value

Device exercises hands of persons whose fingers are generally straight and need to be flexed inward toward palms of hands. Device is extremely simple in design, which reduces costs, and fits all hand sizes. Patient can instantly free hand from device by pulling flap free from wrist of straps.

Barthlome, D. E.↗

Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

Montgomery, L. D.↗

Effect of hand-based sensors on manipulator control performance

Manipulator task categories and motion phases require various hand-based information systems to meet the control performance requirements. The effect of proximity, tactile and force/torque sensors on the performance of remote manipulator control is discussed. An overview is presented on various experimental hand-based information systems which provide the manipulator controller some non-visual 'awareness' of the task environment. The rest of the paper describes and evaluates various control experiments performed at JPL using hand-mounted proximity sensors to guide and control hand motion near solid objects.

Bejczy, A. K.↗

Six Degrees of Freedom Control with Each Hand?

For some time man has made six degree of freedom inputs to a pair of dextrous manipulators using both hands simultaneously by the use of the master/slave concept. The advent of the microprocessor has the potential to make the master/slave concept redundant by replacing the master with a mathematical model. All spacecraft to date, including the space shuttle, that were flown in six degrees of freedom were controlled by using both hands, the left hand controlling translation and the right rotation. Almost inevitably the same principle was applied to the CANADARM. At the instigation of NASA the development of a device whereby both translation and rotation could be combined allowing full control with one hand was developed. The development and testing of the device, and the extension of its application into spaceflight control are described. Also the concept of an adaptable workstation for multi-maniipulator and spacecraft flight control is discussed.

King, M. L.↗

Hand-Strength Meter

Special grip-strength meter designed for accurate, reproducible measurement of hand rehabilitation. Four strain gauges connected in Wheatstone bridge to measure deflection caused by gripping hand. Compressive force exerted by hand transmitted to measuring beams. Beams therefore deflected or strained, and mechanical strain sensed by strain gauges and converted into electrical signal. After amplification and conditioning, signal displayed on LED as measure of gripping strength of hand.

Tcheng, Ping↗

Two-Thumbed Robot Hand

Robot hand includes thumblike members on left and right sides and fingerlike member at middle. Configuration of digits enables hand to adapt to variously shaped objects, grasp them robustly and reliably, and manipulate them. Reduces complexity of control mechanisms and provides kinesthetic perception of shapes of grasped objects. Mechanical hand with two thumbs and middle finger made from commercially available components. With specially designed dc motors and assemblies of gears, size of hand reduced considerably. Suited to handling objects in industrial tasks.

Lee, Sukhan↗

Multiple sensor smart robot hand with force control

A smart robot hand developed at JPL for the Protoflight Manipulator Arm (PFMA) is described. The development of this smart hand was based on an integrated design and subsystem architecture by considering mechanism, electronics, sensing, control, display, and operator interface in an integrated design approach. The mechanical details of this smart hand and the overall subsystem are described elsewhere. The sensing and electronics components of the JPL/PFMA smart hand are summarized and it is described in some detail in control capabilities.

Killion, Richard R.↗

Sensing human hand motions for controlling dexterous robots

The Dexterous Hand Master (DHM) system is designed to control dexterous robot hands such as the UTAH/MIT and Stanford/JPL hands. It is the first commercially available device which makes it possible to accurately and confortably track the complex motion of the human finger joints. The DHM is adaptable to a wide variety of human hand sizes and shapes, throughout their full range of motion.

Marcus, Beth A.↗

Issues in human/computer control of dexterous remote hands

Much research on dexterous robot hands has been aimed at the design and control problems associated with their autonomous operation, while relatively little research has addressed the problem of direct human control. It is likely that these two modes can be combined in a complementary manner yielding more capability than either alone could provide. While many of the issues in mixed computer/human control of dexterous hands parallel those found in supervisory control of traditional remote manipulators, the unique geometry and capabilities of dexterous hands pose many new problems. Among these are the control of redundant degrees of freedom, grasp stabilization and specification of non-anthropomorphic behavior. An overview is given of progress made at the MIT AI Laboratory in control of the Salisbury 3 finger hand, including experiments in grasp planning and manipulation via controlled slip. It is also suggested how we might introduce human control into the process at a variety of functional levels.

Salisbury, K.↗

Measurement of hand dynamics in a microsurgery environment: Preliminary data in the design of a bimanual telemicro-operation test bed

Data describing the microsurgeon's hand dynamics was recorded and analyzed in order to provide an accurate model for the telemicrosurgery application of the Bimanual Telemicro-operation Test Bed. The model, in turn, will guide the development of algorithms for the control of robotic systems in bimanual telemicro-operation tasks. Measurements were made at the hand-tool interface and include position, acceleration and force between the tool-finger interface. Position information was captured using an orthogonal pulsed magnetic field positioning system resulting in measurements in all six degrees-of-freedom (DOF). Acceleration data at the hands was obtained using accelerometers positioned in a triaxial arrangement on the back of the hand allowing measurements in all three cartesian-coordinate axes. Force data was obtained by using miniature load cells positioned between the tool and the finger and included those forces experienced perpendicular to the tool shaft and those transferred from the tool-tissue site. Position data will provide a minimum/maximum reference frame for the robotic system's work space or envelope. Acceleration data will define the response times needed by the robotic system in order to emulate and subsequently outperform the human operator's tool movements. The force measurements will aid in designing a force-reflective, force-scaling system as well as defining the range of forces the robotic system will encounter. All analog data was acquired by a 16-channel analog-to-digital conversion system residing in a IBM PC/AT-compatible computer at the Center's laboratory. The same system was also used to analyze and present the data.

Charles, Steve↗