584 records · Page 5

Heat Flow and Thermal History of the Moon

An analysis was made of current heat flow data and thermal models of lunar evolution which satisfy the diverse information that has accumulated on internal processes.

Ye A Lyubimova

Studies of Flame Structure in Microgravity

The present research endeavor is concerned with gaining fundamental understanding of the configuration, structure, and dynamics of laminar premixed and diffusion flames under conditions of negligible effects of gravity. Of particular interest is the potential to establish and hence study the properties of spherically- and cylindrically-symmetric flames and their response to external forces not related to gravity. For example, in an earlier experimental study of the burner-stabilized cylindrical premixed flames, the possibility of flame stabilization through flow divergence was established, while the resulting one-dimensional, adiabatic, stretchless flame also allowed an accurate means of determining the laminar flame speeds of combustible mixtures. We have recently extended our studies of the flame structure in microgravity along the following directions: (1) Analysis of the dynamics of spherical premixed flames; (2) Analysis of the spreading of cylindrical diffusion flames; (3) Experimental observation of an interesting dual luminous zone structure of a steady-state, microbuoyancy, spherical diffusion flame of air burning in a hydrogen/methane mixture environment, and its subsequent quantification through computational simulation with detailed chemistry and transport; (4) Experimental quantification of the unsteady growth of a spherical diffusion flame; and (5) Computational simulation of stretched, diffusionally-imbalanced premixed flames near and beyond the conventional limits of flammability, and the substantiation of the concept of extended limits of flammability. Motivation and results of these investigations are individually discussed.

C K Law

In-Situ Heat Rejection to the Martian Atmosphere

In order to provide in-situ heat rejection to the thin Martian atmosphere, approaches relying on forced convection and buoyancy flow are conceptualized. A convective radiator concept utilizing a fan to draw local atmosphere through an expanded metal foam heat exchanger panel is developed. To provide a pumped fluid loop interface, flow tubes are embedded in the heat exchanger panel and heat is transferred from the tubes to the foam via conduction and subsequently convectively to the environment. To forgo the use of a specialized high throughput fan, a concept utilizing a buoyant chimney tower to draw atmospheric flow through a low pressure drop heat exchanger is also considered. Both concepts may best align with moderate- to high-temperature heat loads that provide a significant delta temperature relative to the ambient atmosphere temperature. While eliminating dust accumulation on radiator surfaces, some type of serviceable filtration or screening may be required to prevent accumulation of dust inside the expanded metal foam heat exchanger for both concepts.

Heat Rejection

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Environmental Performance Report 2025: Annual Site Environmental Report per the U.S. Department of Energy Order 231.1B Chg 1

The National Laboratory of the Rockies (NLR) Environmental Performance Report provides a description of the laboratory's environmental management activities in calendar year 2025, including information on environmental performance, environmental compliance activities and status, and environmental protection programs, highlights, and successes. The purpose of this report is to ensure that the U.S. Department of Energy (DOE) and the public receive timely, accurate information about events that have positively affected or could adversely affect the health and safety of the public or workers, the environment, or the operations of DOE facilities. This report meets the DOE requirements of the Annual Site Environmental Report (ASER) and has been prepared in accordance with DOE Order 231.1B Chg 1, Environment, Safety and Health Reporting.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water