Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat pump modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

Geoghegan, Patrick J↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Study and Development of an Air Conditioning System Operating on a Magnetic Heat Pump Cycle

This report describes the design of a laboratory scale demonstration prototype of an air conditioning system operating on a magnetic heat pump cycle. Design parameters were selected through studies performed by a Kennedy Space Center (KSC) System Simulation Computer Model. The heat pump consists of a rotor turning through four magnetic fields that are created by permanent magnets. Gadolinium was selected as the working material for this demonstration prototype. The rotor was designed to be constructed of flat parallel disks of gadolinium with very little space in between. The rotor rotates in an aluminum housing. The laboratory scale demonstration prototype is designed to provide a theoretical Carnot Cycle efficiency of 62 percent and a Coefficient of Performance of 16.55.

Wang, Pao-Lien↗

Cost-Optimized CCHP Model Developed Using HPDM Meeting Performance Targets

This report documents the equipment design and analysis work to meet the first project milestone (M1). Our industry partner, Emerson Commercial & Residential Solutions recently developed a 3-stage scroll compressor product, able to deliver capacity at three levels without using an inverter. Based on ORNL’s previous cold climate heat pump (CCHP) prototype and the preliminary compressor performance data, the CCHP was redesigned for cost reduction and better performance. The 3-stage compressor, using the middle capacity level to deliver the rated capacity of the heat pump (HP), will replace the previous tandem compressors, using one single-speed compressor to deliver the rated capacity. In this way, it will reduce the compressor footprint to fit in most residential HPs’ chassis. The compressor replacement increases the nominal capacity by 17%. Approximately, 30% cost reduction in the compressor and 17% reduction in the heat exchangers per nominal tonnage can be achieved relative to the prior tandem compressor design. Advanced features using an electronic expansion valve for head pressure control and an Ebm-papst variable-speed, backward-curved indoor blower can be adopted for higher efficiency.The DOE/ORNL Heat Pump Design Model (HPDM) was used to model and redesign the CCHP. Following AHRI 210/240, heating and cooling performance results were predicted at the conditions for certifying a 2-stage CCHP, regarding various design scenarios. The predicted HSPF reaches 12.0, and predicted SEER reaches16.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants

Based on laboratory investigations for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), the DOE/ORNL Heat Pump Design Model was used to model the two RTUs and the models were calibrated against the experimental data. We compared the compressor efficiencies and heat exchanger performances. An efficiency-based compressor mapping method was developed. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting optimal configurations. The results illustrate that all the R-22 low GWP refrigerants will lead to slightly lower COPs. ARM-20B appears to be the best R-22 replacement at normal conditions. At higher ambient temperatures, ARM-20A exhibits better performance. All R-410A low GWP candidates will result in similar or better efficiencies than R-410A. R-32 has the best COP while requiring the smallest compressor. Finally, R-452B uses the closest compressor displacement volume and achieves the same efficiency as R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

The energy service needs of a net-zero-energy house (ZEH) include space heating and cooling, water heating, ventilation, dehumidification, and humidification, depending on the requirements of the specific location. These requirements differ in significant ways from those of current housing. For instance, the most recent DOE buildings energy data (DOE/BED 2007) indicate that on average {approx}43% of residential buildings primary energy use is for space heating and cooling, vs. {approx}12% for water heating (about a 3.6:1 ratio). In contrast, for the particular prototype ZEH structures used in the analyses in this report, that ratio ranges from about 0.3:1 to 1.6:1 depending on location. The high-performance envelope of a ZEH results in much lower space heating and cooling loads relative to current housing and also makes the house sufficiently air-tight to require mechanical ventilation for indoor air quality. These envelope characteristics mean that the space conditioning load will be closer in size to the water heating load, which depends on occupant behavior and thus is not expected to drop by any significant amount because of an improved envelope. In some locations such as the Gulf Coast area, additional dehumidification will almost certainly be required during the shoulder and cooling seasons. In locales with heavy space heating needs, supplemental humidification may be needed because of health concerns or may be desired for improved occupant comfort. The U.S. Department of Energy (DOE) has determined that achieving their ZEH goal will require energy service equipment that can meet these needs while using 50% less energy than current equipment. One promising approach to meeting this requirement is through an integrated heat pump (IHP) - a single system based on heat pumping technology. The energy benefits of an IHP stem from the ability to utilize otherwise wasted energy; for example, heat rejected by the space cooling operation can be used for water heating. With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of Baxter (2007).

15 GEOTHERMAL ENERGY↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

West Village Student Housing Phase I: Apartment Monitoring and Evaluation

Building America team Alliance for Residential Building Innovation (ARBI) worked with the University of California, Davis (UC Davis) and the developer partner West Village Community Partnership (WVCP) to evaluate performance on 192 student apartments completed in September, 2011 as part of Phase I of the multi-purpose West Village project. West Village, the largest planned zero net energy community in the United States. The campus neighborhood is designed to enable faculty, staff and students to affordably live near campus, take advantage of environmentally friendly transportation options, and participate fully in campus life. The aggressive energy efficiency measures that are incorporated in the design contribute to source energy reductions of 37% over the B10 Benchmark. The energy efficiency measures that are incorporated into these apartments include increased wall & attic insulation, high performance windows, high efficiency heat pumps for heating and cooling, central heat pump water heaters (HPWHs), 100% high efficacy lighting, and ENERGY STAR major appliances. Results discuss how measured energy use compares to modeling estimates over a 10 month monitoring period and includes a cost effective evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗