Implementing Induction-Heated Time-at-Temperature Testing Workflows for Irradiated Materials
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This material will be presented at the Interagency Advanced Power Group (IAPG) Chemical Working Group and Safety Panel Meeting. IAPG serves as the premier organization coordinating the collaboration and information exchange of advanced power research and development within the U.S. government.
A new direct air capture (DAC) technology uses a moisture swing (MS) process with anion exchange membranes, potentially offering a more energy-efficient way to remove CO₂ from the air. In this MS process, the membrane absorbs CO₂ as it dries and releases it when water is added. Understanding the mechanical behavior of these membranes is essential for improving the design and efficiency of DAC systems and prolonging sorbent lifetime. This study tested one anion exchange membrane, Fumasep’s FAA-3, under mechanical loading and various temperature and humidity conditions to measure its swelling, stiffness, strength, plastic deformation, and stress relaxation. Experimental results were used to identify a mechanical model for FAA-3 that can be used to predict the material’s nonlinear viscous behavior under various loads and environments. Unlike prior studies that assumed linear elastic behavior, this work incorporates humidity-dependent swelling, thermal expansion, and nonlinear viscoelasticity of FAA-3 in both the experiments and the model.
Building energy simulation is a critical tool for developing and testing advanced control strategies, such as Reinforcement Learning (RL), to provide demand flexibility and affordable energy costs. The recently introduced Smart Buildings Control Suite (sbsim) provides a lightweight, scalable, and data-calibrated simulation environment based on a 2D finite-difference model. However, the initial model primarily focused on conductive and convective heat transfer, neglecting the significant impact of long-wave radiative heat exchange between interior surfaces. This paper presents a significant extension to the sbsim framework by incorporating a physically-grounded model for interior radiative heat transfer. Our primary contribution is the development and integration of a fully tensorized radiative heat transfer module, which preserves the computational efficiency and scalability of the original simulator. This was achieved by developing a pipeline for view factor calculation, including an algorithm to identify directly seeing surfaces within complex floor plans, and formulating the net radiation equations for efficient execution on modern hardware accelerators. We validate the numerical accuracy of our tensorized implementation by comparing its results against a traditional iterative approach, demonstrating identical outcomes. This enhancement increases the physical fidelity of sbsim, enabling more accurate training of RL agents for building energy optimization.
Artificial heating in plasma simulations is a well-known phenomenon which occurs when, among other things, the Debye length is poorly resolved by the simulation mesh. Here, in this work, the degree to which numerical-heating occurs during a simulation of a nanosecond atmospheric pressure streamer discharge is examined. The streamer is simulated using a two-dimensional finite-element, particle-in-cell code Empire, which uses direct simulation Monte Carlo for binary particle interactions. Initially, an estimate of the numerical-heating rate applied to Empire is performed using a simple plasma model. Second, a positive atmospheric pressure streamer discharge simulation is performed to study the effects of numerical heating on plasma density, electron temperature, and streamer velocity. The nominal Debye length is approximately 1 μm and the amount of numerical heating introduced in the simulation is varied by using mesh sizes ranging from 2 μm to 20 μm. A measurable numerical heating quantity is proposed that can be used to estimate the appropriate element size and quantify the numerical-heating that can be expected over the simulation time for an atmospheric pressure streamer. In conclusion while Δx/λ D violations can be an issue it is not likely to be an issue with streamer discharges that are temporally short and occur in environments where collision frequencies are high. This result validates the rationale of grid size choices for a large amount of previously published works where Δx/λ D violation was not clearly addressed. Primary finding of this work is that numerical heating is of minor concern for plasma simulations where electron–neutral collisions are numerous such that multiple collisions can occur within a single plasma period.
In a nuclear reactor, prolonged exposure to high neutron flux levels can change material properties of reactor components. Due to the danger posed to personnel by highly radioactive components such as spent fuel, noncontact methods must be used to determine these properties. The objective of the current research is to test the viability of using a flash-heating method to determine the thermal diffusivity of a silicon carbide (SiC) tube, which could be used as cladding for a nuclear fuel rod. The flash-heating experiment was conducted at Oak Ridge National Laboratory and temperature results were analyzed as a two-Dimensional cross section which assumed axial symmetry. The model was fitted iteratively to the temperature measurements using nonlinear regression which required values for thermal diffusivity, Biot number and a term to determine the magnitude of the heat absorbed by the flash. The method could be expanded in the future to estimate the thermal diffusivity of spent nuclear fuel rods in an effort to increase the certainty of new reactor designs using precise thermal properties throughout the core life. A statistical analysis of the results of this work is provided as part of the analysis.
In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.
Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .
Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.
Roots are responsible for soil water uptake, yet little is known about how variation in fine-root traits relates to whole-tree water movement, particularly during periods of drought. By combining a 3-yr dataset monitoring sap flow rates with measures of fine-root biomass, length, and morphology across 10 tree species, we addressed hypotheses concerning the role of fine-root system size and morphology in determining tree responses to summer drought as well as potential changes in their relative importance under more severe droughts. Greater fine-root biomass and length did not enable trees to maintain high rates of sap flow during drought, whereas the morphological traits, specific root length and specific root area, were linked to sustained sap flow rates during drought. We found that all species, irrespective of root traits, progressively reduced their sap flow under more extreme drought conditions, although more acquisitive root morphology was still associated with smaller reductions. Our results run counter to long-standing assumptions that larger root systems are better able to access soil water and maintain photosynthetic activity during drought. Instead, we find evidence that root morphology at least partially determines the capacity for water uptake and movement as soil moisture declines.
Combining the effects of alternating-current (AC) electric fields and sedimentation reconfigures colloidal discoids between planar and homeotropic orientational alignments, thereby controlling the material’s structural color. Here, we self-assemble micrometer-size polystyrene discoids in an isopropanol-water mixture. After sedimentation, the discoids adopt a homeotropic alignment, with the minor axis perpendicular to the substrate. Adding an AC electric field (1 kHz) of ≥0.50 V switches the discoids to planar alignment—with the minor axis parallel to the substrate—within ∼100 s. Removing the field switches them back to homeotropic alignment within ∼300 s. Kinetic modeling of the field-induced torques yields good agreement with these measurements. The peak wavelength and intensity of the crystal’s diffraction response shift significantly upon reconfiguration; scattering simulation predicts these shifts. The reconfiguration is maintained for at least 10 cycles. This method is a simple, scalable avenue to reconfigure the optical properties of colloidal crystals produced from simple dielectric spheroids.
We present a method for calculating the heat fluxes deposited on nonaxisymmetric tokamak first wall components, allowing for a first-of-its-kind model for power handling in the tokamak far scrape-off layer (SOL). The DIV3D Monte Carlo model features strict global power conservation and can calculate the finite cross-field plasma transport into magnetically-shadowed regions, which is significant when dealing with meter-scale shadows introduced by components such as poloidal limiters or antennas. As a case study, we apply the DIV3D model to inform the distribution of first wall poloidal limiters in an ARC-class reactor device. We demonstrate that discrete protection limiters can efficiently reduce peak heat fluxes on recessed breeder wall components in the presence of significant far-SOL plasma fluxes. By varying the toroidal periodicity and radial standoff depth of the limiters, we demonstrate one of the tradeoffs that must be considered in first wall design: more limiters provide greater protection, but at the cost of reduced breeding performance. We also present the impact that radial misalignments between limiters would have on first wall power loading.
Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.
Chemical separations are costly in terms of energy, time, and money. Separation methods are optimized with inefficient trial-and-error approaches that lack insight into the molecular dynamics that lead to the success or failure of a separation and, hence, ways to improve the process. We perform super-resolution imaging of fluorescent analytes in five different commercial liquid chromatography materials. Unexpectedly, we observe that chemical functionalization can block more than 50% of the material’s porous interior, rendering it inaccessible to small-molecule analytes. Only in situ imaging unveils the inaccessibility when compared to the industry-accepted ex situ characterization methods. Selectively removing some of the functionalization with solvent restores pore access without substantially altering the single-molecule kinetics that underlie the separation and agree with bulk chromatography measurements. Our molecular results determine that commercial “fully porous” stationary phases are over-functionalized and provide an alternative avenue to characterize and direct separation material design from the bottom-up.
Conventional electrochemical reactors for nitrate reduction typically suffer from limited reaction efficiency when applied for real-world water treatment due to poor utilization of electrocatalytic active sites. Here, we applied nanoporous electrofiltration to intensify atomic utilization by incorporating single-atom catalysts into an electrified membrane for reducing low-concentration nitrate to ammonia under realistic water conditions. We enhance the exposure of single atoms in nanopores by coating the catalysts on a carbon nanotube–interwoven membrane framework. Electrofiltration intensifies the transport and adsorption of nitrate in confined nanopores with highly exposed single-atom active sites to enhance reduction. The membrane enables a superior ammonia turnover frequency of 15.1 grams of nitrogen per gram of metal per hour, up to four orders of magnitude higher than that reported in the literature, under both high removal efficiency and Faradaic efficiency of over 86% when treating influents with a low nitrate concentration of 100 milligrams of nitrogen per liter in a residence time on the order of seconds.
Interfacial thermal and acoustic phenomena have an important role in quantum science and technology, including in spintronic and spincaloritronic materials and devices. Simultaneous measurements of the low-temperature thermal and acoustic properties of a metal/insulator heterostructure reveal distinct dynamics in the characteristic phonon frequency ranges of acoustic and thermal transport. The measurements probed a heterostructure consisting of a thin film of Pt on the ferrimagnetic insulator gadolinium iron garnet (Gd 3 Fe 5 O 12 , GdIG) grown epitaxially on a gadolinium gallium garnet substrate. Ultrafast structural dynamics within the Pt layer were tracked using time-resolved ultrafast x-ray diffraction and analyzed to probe interfacial acoustic and thermal properties. The rapid heating of the Pt layer by a 400 nm wavelength femtosecond-duration optical pulse produced transient structural changes that provided the stimulus for these measurements. Rapid heating produced a broadband acoustic pulse that was partially reflected by the Pt/GdIG interface. Temporal frequencies up to 740 GHz, corresponding to angular frequencies of several THz, were detected in a wavelet analysis of the acoustic oscillations of the strain in the Pt layer. The structural results were analyzed to determine (i) the acoustic damping coefficient and phonon mean free path in Pt at frequencies of hundreds of GHz and (ii) the Grüneisen anharmonicity parameter. The thermal conductance of the Pt/GdIG interface was tracked using the slower, tens-of-picosecond-scale, dynamics of the initial cooling of the heated Pt layer. Analysis using a model based on the Boltzmann transport equation shows that the phonon transmission is lower at the phonon frequencies relevant to thermal transport than for subterahertz regime acoustics.
Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.
Sodium-ion batteries (SIBs) are a sustainable alternative to lithium-ion systems for global electrification, with O3-type layered oxide cathodes offering high specific capacity and feasibility of scalable synthesis. Industrial co-precipitation synthesis of these cathodes typically uses transition metal sulfates, requiring extensive water rinsing to remove Na 2 SO 4 impurities, a process that consumes significant water and risks residual inactive phases if incomplete. Here, this work introduces a rinse-free, resource-efficient approach using metal acetate precursors. Residual sodium acetate in non-rinsed precursors decomposes during sintering to generate Na 2 CO 3 in situ, partially substituting an external sodium resource (e.g., NaOH and Na 2 CO 3 ) and reducing its consumption by ∼18–20%. Phase-pure O3-Na 1.0 Ni 1/3 Fe 1/3 Mn 1/3 O 2 (NFM111) cathodes synthesized via this method exhibit microstructure and electrochemical performance comparable to rinsed sulfate-derived counterparts, with initial capacities of 141 mAh g −1 at C/20 (7.5 mA g −1 ). By eliminating rinsing and minimizing sodium reagent use, this acetate-based route enhances sustainability and scalability of layered oxide production for SIBs.