Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molten salt compositions with enhanced heat transfer and reduced corrosion properties

A heat transfer (exchange) composition comprising a halide salt matrix having dispersed therein nanoparticles comprising elemental carbon in the absence of water and surfactants, wherein said halide is fluoride or chloride, wherein the halide salt may be an alkali halide salt (e.g., lithium fluoride, sodium fluoride, potassium fluoride, rubidium fluoride, sodium chloride, potassium chloride, rubidium chloride, and eutectic mixtures thereof) or an alkaline earth halide salt (e.g., fluoride or chloride salt of beryllium, magnesium, calcium, strontium, or barium), and wherein the nanoparticles comprising elemental carbon may be solid or hollow, and wherein the composition may further include nanoparticles comprising a fissile material (e.g., U, Th, or Pu) dispersed within the composition. Molten salt reactors (MSRs) containing these heat transfer compositions in coolant loops in thermal exchange with a reactor core, as well operation of such MSRs, are also described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of the Heat Transfer Coefficient in the Outer Body for a Rotational Detonation

Unsteady heat transfer characterization on the combustion surfaces of Rotational Detonation Engines (RDE) is not well understood. It is generally thought that the complex nature of the unsteady, reacting, compressible fluid flow inside the combustion anulus of the RDE causes the convective heat transfer coefficient to be significantly higher than it is in other applications. Empirical models that have been used to analyze this strictly apply to steady flows where dimensionless groups can be employed. The reacting flow fields that are characteristic of RDEs are inherently compressible, three dimensional, unsteady, and turbulent, having properties that change by orders of magnitude throughout the flow field. They will therefore contain multiple length scales and time scales operating everywhere in the flow during all times. Because of this it is not likely that the RDE flow fields will lend themselves to explanation using simple dimensionless parameters. The dimensionless groups have meaning only in situations where length scales and time scales are singular and well defined. In spite of this it may be possible to get a relatively good idea of what the convection heat transfer coefficient is. In this work a numerical study is performed where the inside wall surface temperature distribution in the RDE outer body is systematically changed over a given range that would be characteristic of the start-up flows inside an RDE. For each case, temperature distributions inside the outer containment wall of the RDE was calculated and compared with experimental data. The closet match can then be used to directly calculate the convection heat transfer coefficient on the inside surface of the RDE.

VanOsdol, John↗

Improvements of SAM Heat Transfer Models for Molten Salt-Cooled Pebble Bed Reactors

To support the development and utilization of the SAM code for molten salt-cooled pebble bed reactor safety analyses and licensing, selected improvements were made to the one-dimensional system-level heat transfer modeling in SAM with the goal of better capturing heat transfer phenomena specific to these designs. In consideration of molten salt as a coolant, new models were introduced to capture the enhanced radiative heat transfer that must be considered at the higher working temperatures. Radiative heat transfer is handled not only between two structural surfaces, but also in combination between the surfaces and the molten salt fluid, which has a higher opacity and absorption of radiative heat as compared to water. Several examples of analytical verification of the new radiative heat transfer methods are included in this report. Additionally, convective heat transfer correlations were selected from literature and included in SAM to account for the enhanced heat transfer expected in pebble bed geometry flows. These correlations are verified and demonstrated in the present work with a reference FHR example.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

A note on thermal history kernel for unsteady heat transfer of a spherical particle

When a particle is subjected to an unsteady ambient flow, in terms of either time-dependent relative velocity or time-dependent temperature difference, the net heat transfer from the particle cannot be calculated based on the quasi-steady heat transfer correlation alone. Due to unsteady evolution of the thermal boundary layer, there is also a history contribution to heat transfer. The history contribution to heat transfer is expressed as a convolution integral of past evolution of temperature difference between the particle and the surrounding. While Basset history force and its finite Reynolds number extension have been well studied, similar understanding of unsteady heat transfer and thermal history kernel is lacking. Here, we use existing particle-resolved simulation results to develop a finite Peclet number thermal history kernel, which when used with the convolution integral is demonstrated to accurately predict unsteady heat transfer over a range of Peclet numbers and particle-to-fluid heat capacity ratio.

42 ENGINEERING↗

Convective heat transfer enhancement through additively built multiscale micro-tetrahedron features

Use of Additive Manufacturing (AM) to improve the heat transfer characteristics of tip shrouds in high-pressure turbines is being considered by industries. Existing designs of these components integrate micro-cooling channels to reduce the bulk temperature for improved life. In this research, closely packed micro tetrahedron features in addition to AM roughness has been considered. Further, this multiscale surface characteristics increased surface area per unit volume available for heat exchange. Micro-tet features were designed, manufactured, characterized, and evaluated systematically while increasing their height. An enormous increase in the overall wetted surface area by 200 % was measured. The convective heat transfer enhancement was ~3.72 times EDM rough coupon, and friction factor enhancement was ~5.5 times EDM rough coupon. Furthermore, the proposed design offers 2.5 times enhanced heat transfer for a given 2 W pumping power compared to our EDM rough coupon. Heat transfer enhancement was observed to not vary strongly with increased Reynolds number. Such complex designs are only possible through additive manufacturing for increased heat transfer with little pressure penalty. Finally, increasing the micro-tet height for increased surface area and improved heat exchange beyond an upper limit might not be a significant benefit as it gets compensated by increasing skin friction.

42 ENGINEERING↗

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles is investigated using a novel transient three-dimensional computational fluid dynamics model. The model couples particle–gas hydrodynamics of solid–gas flows laden with polydisperse particles, radiative heat transfer in non-grey absorbing, emitting and anisotropically-scattering multi-component participating media, conduction heat transfer in the gas phase, and interfacial convection heat transfer. The multiphase particle-in-cell method is used to predict high-fidelity solid–gas flow characteristics, such as the local discrete particle size distribution, with increased computational efficiency by combining the advantages of both Eulerian and Lagrangian methods. The multi-component radiative transfer model is implemented using an advanced collision-based Monte Carlo ray-tracing method. The number of the prescribed discrete particle components is found to be the key parameter affecting the computational accuracy and efficiency, which primarily depends on the size distribution of the particles. For the model particle–gas flow featuring free-falling Gamma-distributed ceramic particles exposed to concentrated solar irradiation, the particle volume fraction, radiative, fluid flow and thermal characteristics appear to converge with the increasing number of the discrete particle components. Five particle components are sufficient to obtain physically meaningful results. A further increase in the number of the particle components only slightly increases the accuracy of the numerical predictions at the expense of a rapidly increasing computational time. For five particle components, the particle vertical velocity at the receiver exit for particles with the diameter of 43.4 μm is 57% of that for the particles with the diameter of 202.8 μm. The temperatures of these two particle components increase from the initial ambient values by factors of 2 and 1.2, respectively, during the simulation time. In conclusion, the model developed allows for increased fidelity of particle–gas flow simulations with significant radiative effects.

97 MATHEMATICS AND COMPUTING↗

Characterization of Fuel-to-Coolant Heat Transfer During Reactivity-Initiated Accidents Using Tightly Coupled Thermal Hydraulics and Fuel Thermomechanics

The reactivity-initiated accident (RIA) is a complex scenario with several tightly interacting physical phenomena. Accurately predicting fuel behavior during these transients is difficult due to limitations in the modeling of fuel-to-coolant heat transfer. Common approaches to simulate RIAs involve standalone calculations using either a fuel performance code or a thermal-hydraulic code. The complex interdependencies of thermal-hydraulic and fuel mechanical behavior suggest that a tight coupling between these codes may provide more accurate predictions of fuel-to-coolant heat transfer and cladding mechanical response. Here, RELAP5-3D and BISON are coupled in this paper to simulate RIAs, and a sensitivity analysis is performed to rank key thermal properties and two-phase heat transfer parameters relevant for fuel-to-coolant heat transfer and cladding failure mechanisms in UO 2 –Zircaloy-4 systems. Gas gap conductance, film boiling heat transfer uncertainty, pulse width, fuel-specific heat capacity, and cladding-specific heat capacity were identified as important parameters. Variations in figures of merit resulting from changes to pulse width and the material thermal properties indicate that time-dependent heat transfer rates are significant for safety-relevant mechanical parameters due to the time dependence of cladding ductility and pellet-cladding mechanical interaction loading. The results suggest that the thermal-hydraulic factors have a nonnegligible influence on the thermomechanical solution and vice versa. Tight coupling of both sets of physics is recommended to improve prediction of fuel behavior during RIAs. Highlights include the following: 1. The RELAP5-3D thermal-hydraulic code and the BISON fuel performance code are tightly coupled for simulation of RIA transients with energy depositions at the Zircaloy-4 cladding failure threshold. 2. Departure from nucleate boiling occurred for all simulated cases. Due to the ductility of fresh fuel, substantial ballooning occurred in most cases. 3. Gas gap conductance, fuel-specific heat capacity, cladding-specific heat capacity, transient pulse width, and film boiling heat transfer were the dominant thermal factors impacting the safety figures of merit at energy depositions.

Critical Heat Flux (CHF)↗

Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl 2 Molten Salts by Principle of Entropy Generation Minimization

The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl 2 and KCl–MgCl 2 . The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO 2 power cycles in concentrated solar power (CSP) system. Here, optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.

14 SOLAR ENERGY↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

Technoeconomic assessment of distillation heat transfer intensification using aeroelastically fluttering reeds

Dry cooling, where forced air is the heat transfer medium, is a preferable cooling method in arid locations lacking readily available process water. However, such locations often experience high ambient temperatures that limit the effectiveness of air cooling. The objective of this study is to quantify the economic and energetic benefits of heat transfer intensification via the implementation of aeroelastically fluttering reeds to the air-cooled condenser of a methanol distillation column. Condenser size and performance, regarding recovered methanol and required fan power, is evaluated across condenser operating temperatures (T cond ) from 60 to 62°C and heat transfer coefficients (U) U base –2U base for a range of inlet air temperatures based on ambient temperature data from Yuma, Arizona. Under typical design sizing, condenser capital cost was reduced by 6%–35% (1.3U base –2U base ) and nominal methanol recovery was increased from 0.26% to 0.38% (T cond = 62–60°C). At optimized condenser size, all enhanced U and T cond pairs increase methanol recovery and reduce fan power costs compared to the optimal Ubase reference. Overall, using enhanced heat transfer to maintain condenser temperature under a wider range of inlet conditions, rather than to reduce operation temperature, produces more favorable performance. Methanol price is not a determining factor in which pairs are profitable. Analysis was repeated for a global warming scenario, revealing more valuable improvements under elevated temperatures. Energy savings from condenser improvement to a methanol production system are not significant with respect to an optimized conventional system. Furthermore, unit economic and energetic incentives suggest implementation of fluttering reeds may be justified in other applications.

42 ENGINEERING↗

A Critical Review of Fluoride Salt Heat Transfer

Interest in molten salts for next-generation nuclear reactors has given rise increasing design work over the last several years. Much of this builds off historic heat transfer experiments like those of the Molten Salt Reactor Program; yet, there is no comprehensive report covering experimental heat transfer in these fluids. This paper attempts to pull together all available reports on fluoride salt heat transfer to aid further research in this area. The data largely support the hypothesis that molten salt heat transfer will be easy to predict so long as salt properties are well known. Our work does not show any consistent indications of resistive films, entrained gases, or radiation heat transfer, but other unknowns are present. In addition to salt properties, these include unusual mass transfer and transition flow conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Augmentation of pool boiling heat transfer on tube bundles using metal foam

Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.

42 ENGINEERING↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Study of Eutectic Molten Salts NaCl/KCl/ZnCl2 Heat Transfer Inside a Smooth Tube for High-Temperature Application

Abstract Eutectic salts NaCl-KCl-ZnCl2 and NaCl-KCl-MgCl2 are two of the chloride salt systems that are promising for being used as high-temperature heat transfer fluid (HTF) and thermal energy storage (TES) materials in a wide range of temperatures from 230 °C to 750 °C in concentrated solar thermal power systems. To conduct measurement of the heat transfer coefficient of the molten salt at high temperatures, a circulation system and instrumentation of flow and heat transfer was constructed. Experimental measurement of the convective heat transfer coefficients of NaCl-KCl-ZnCl2 (molar fraction: 13.8–41.9–44.3%) inside tubes has been accomplished to find the most suitable heat transfer correlations. Experience of salt processing and operation of the high-temperature heat transfer test system was obtained. Two correlations, Dittus-Boelter equation and Gnielinski’s correlation for Nusselt number against Reynolds number and Prandtl number, are evaluated using the test results, and the latter correlation is recommended due to its better agreement of prediction against tested data.

Energy & Fuels↗

Experimental and Computational Heat Transfer Study of sCO 2 Single-Jet Impingement

This study experimentally and computationally investigates the heat transfer capability of supercritical carbon dioxide (sCO 2 ) single jet impingement. The evaluated jet Reynolds number range is between 80,000 and 600,000, with a nondimensional jet-to-target surface spacing of 2.8. CO 2 -impinging jet stagnation conditions were maintained at approximately 200 bar and a temperature of ∼400 °C for most experiments. The goal is to understand how changes in the aforementioned parameters influence heat transfer between the working fluid and the heated surface. Additionally, due to the elevated Reynolds numbers and difference in thermodynamic properties between air and CO 2 , air-derived impingement correlations may not be appropriate for CO 2 impingement; these correlations will be evaluated against experimental sCO 2 impingement data. At the time of this study, no sCO 2 impingement data was available relevant to sCO 2 power cycles. The target surface is a 1.5-in. diameter copper block centered on the 3 mm jet orifice. A mica heating element bolted to the bottom of the copper block provides a uniform heat flux. Thermocouples embedded in the copper block are used to determine the surface temperature. Nusselt numbers obtained from experimental sCO 2 test data are compared to area-averaged Nusselt numbers from air-derived correlations. The comparisons showed that air correlations drastically underpredict the heat transfer when sCO 2 is used as the working fluid. A modified sCO 2 correlation using experimental data at discussed conditions is derived based on an existing air correlation. A CFD study is also performed to further investigate sCO 2 heat transfer characteristics, and assess the numerical model applicability to this problem type.

42 ENGINEERING↗