Search NASASearch

SEARCH · Search NASA

Results for “High Explosives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Chemical decomposition in shock-compressed 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals: Time-resolved Raman spectroscopy

Understanding the evolution of chemical decomposition—at the molecular level—in shock-compressed insensitive high explosive (IHE) single crystals is an important need. Toward this goal, time-resolved Raman spectra were measured in 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals shock compressed to stresses above 20 GPa. At 22 GPa and higher stresses, the Raman peak intensities were significantly reduced, showing the onset and extent of chemical changes. At 33 GPa, no Raman peaks were observed, suggesting complete decomposition of FOX-7. The 22 GPa onset from Raman data is in marked contrast to the much higher (32 GPa) onset determined previously from wave profile measurements—showing the significantly greater sensitivity of Raman measurements for gaining insight into shock-induced molecular-level changes in IHE single crystals. The close match between the complete loss of Raman peaks at 33 GPa and the 32 GPa reaction threshold determined from continuum data makes a good case that the two results are related and they reflect significant energy release due to decomposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Equation of state measurement of detonation carbon condensates using optical microscopy and interferometry

Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K 0 = 57.9(17) GPa] with HNS soot [K 0 = 53.7(15) GPa], LX-21 soot [K 0 = 45.8(51) GPa], and PBX 9502 soot [K 0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.

Amorphous materials

Co-Active Subspace Methods for the Joint Analysis of Adjacent Computer Models

Active subspace (AS) methods are a valuable tool for understanding the relationship between the inputs and outputs of a Physics simulation. In this article, an elegant generalization of the traditional ASM is developed to assess the co-activity of two computer models. This generalization, which we refer to as a Co-Active Subspace (Co-AS) Method, allows for the joint analysis of two or more computer models allowing for thorough exploration of the alignment (or non-alignment) of the respective gradient spaces. We define co-active directions, co-sensitivity indices, and a scalar “concordance” metric (and complementary “discordance” pseudo-metric) and we demonstrate that these are powerful tools for understanding the behavior of a class of computer models, especially when used to supplement traditional AS analysis. Details for efficient estimation of the Co-AS and an accompanying R package (concordance) are provided. Practical application is demonstrated through analyzing a set of simulated rate stick experiments for PBX 9501, a high explosive, offering insights into complex model dynamics.

97 MATHEMATICS AND COMPUTING

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

A&L Annual Report: GRM-MAPS

Exploding Bridge Wire (EBW) is an important design for initiating detonators relevant to several LLNL systems. In such designs, a metal bridge wire is in direct contact with a porous secondary high explosive (HE), typically pressed to around 50% of its crystalline density. Initiation is believed to occur through shock waves generated when the bridge wire is made to explode via the rapid passing of a strong current pulse. Permeametry is an important characterization tool for the porous powdered HE (PETN, HMX, etc.) component in such devices. Such powders are well known to coarsen with age, with an accompanying deterioration in performance, which includes increased function time and sensitivity. Among various material characteristics, one that has been shown to correlate the most with such performance parameters is the flow-permeable surface area (FSSA), measured using air-permeametry. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffer from a few drawbacks, most notably as related to monitoring age-related changes in FSSA. This is because it requires re-compaction of the aged powder into the permeametry tube, which in most cases leads to an unwanted increase in FSSA. To address this and a few other shortcomings, we have been developing a modern version of the permeameter, Gee-Reinstein-Maiti Modern Air-Permeametry System (GRM-MAPS). In this report, we summarize progress made in FY25 toward perfecting and calibrating the instrument, which we aim at deploying within surveillance in FY26.

36 MATERIALS SCIENCE

A&L Annual Report: Kapton Strength

Exploding Foil Initiator (EFI) systems function by launching a polymer flyer (often referred to as a slapper) at a high explosive (HE) pellet, which is intended to shock-initiate the HE. Flyer characteristics (e.g., shape, planarity, etc.) are extremely important in this respect, governing their ability to initiate the HE. Polymer models currently used in these systems are largely unvalidated, potentially compromising the integrity of magneto-hydrodynamic (MHD) predictions of EFI function. An improved EFI MHD modelling capability is expected to: (1) expedite optimization of EFI-based initiation system design, (2) enable consideration of EFI-related aging and corresponding lifetime predictions, and (3) potentially minimize the number of costly experiments required to certify EFI designs. To address this knowledge gap, several years ago we began a computational project to develop a higher-fidelity model for Kapton, a Polyimide copolymer most commonly employed as the flyer material in EFI devices.

36 MATERIALS SCIENCE

Report on Lightning Simulation Standards and Facilities

Lightning strikes pose a significant threat to various forms of infrastructure and electrical equipment. Aircraft and high explosives are of particular interest due to the massive ramifications of the device being compromised due to exposure to lightning damage. However, due to lightning being a varying weather phenomenon, testing a device’s vulnerability to lightning is generally not as simple as simply exposing it to real world lightning. To consistently test a device’s ability to survive the worst-case scenario of lightning exposure, the effects of the most severe lightning strikes must be able to be reproduced consistently and measurably. One such facility for this purpose is the Sandia Lightning Simulator (SLS), which is designed to simulate the current waveform of a severe lightning flash. However, the SLS’s design and age lead to difficulties in its operation and inconsistencies in its output. The methodology used in other lightning simulation facilities may offer information on how to improve the SLS’s operation, or at the very least, expose the SLS’s hidden strengths. This report explores lightning simulation, lightning testing standards, and lightning simulation facilities.

42 ENGINEERING

Integrated Security-Safety Consequence Study of a Heat Pipe Reactor

This report presents a preliminary demonstration of integrated security/safety consequence modeling to support potential physical security exemption justifications under the new Title 10 Code of Federal Regulations Part 53 licensing pathway, which allows exemptions if sabotage-induced radiological consequences do not exceed 25 rem at the site boundary two hours after release without mitigative actions. A hypothetical heat pipe microreactor subjected to direct sabotage by a 150 lbs. TNT-equivalent high-explosive device was analyzed using a simplified radionuclide release estimate based on DOE-HDBK-3010-94, implemented in the MELCOR severe accident analysis code to model release transport and attenuation through reactor/building compartments, with MELCOR outputs coupled to MACCS to compute offsite doses and the distance-to-threshold metric D 25rem . Six scenarios were evaluated to examine sensitivities to release pathway/building configuration and radionuclide form (vapor versus aerosols with different size distributions). Results show a positive correlation between leak path factor and D 25rem and indicate that reactor building compartmentalization can substantially reduce consequences (a single-story configuration reduced D 25rem by roughly an order of magnitude relative to a cavity-only configuration), while vapor versus aerosol assumptions had limited impact for the modeled two-story case on the spatial grid used.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING

Rocket Launch Detection with Smartphone Audio and Transfer Learning

Rocket launches generate infrasound signatures that have been detected at great distances. Due to the sparsity of the networks that have made these detections, however, most signals are detected tens of minutes to hours after the rocket launch. In this work, a method of near-real-time detection of rocket launches using data from a network of smartphones located 10–70 km from launch sites is presented. A machine learning model is trained and tested on the open-access Aggregated Smartphone Timeseries of Rocket-generated Acoustics (ASTRA), Smartphone High-explosive Audio Recordings Dataset (SHAReD), and ESC-50 datasets, resulting in a final accuracy of 97% and a false positive rate of <1%. The performance and behavior of the model are summarized, and its suitability for persistent monitoring applications is discussed.

acoustics

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A field-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt γ-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium γ-ray detector. Fine spatial resolution neutron and α detectors enable precise mapping of characteristic γ-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus significantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

Bucher, Brian [Idaho National Laboratory (INL)]

Physics-driven Explosions of Stripped High-mass Stars: Synthetic Light Curves and Spectra of Stripped-envelope Supernovae with Broad Light Curves

Stripped-envelope supernovae (SESNe) represent a significant fraction of core-collapse supernovae, arising from massive stars that have shed their hydrogen and, in some cases, helium envelopes. The origins and explosion mechanisms of SESNe remain a topic of active investigation. In this work, we employ radiative-transfer simulations to model the light curves and spectra of a set of explosions of single, solar-metallicity, massive Wolf–Rayet stars with ejecta masses ranging from 4 to 11 M ⊙ , which were computed from a turbulence-aided and neutrino-driven explosion mechanism. We analyze these synthetic observables to explore the impact of varying ejecta mass and helium content on observable features. We find that the light curve shape of these progenitors with high ejecta masses is consistent with observed SESNe with broad light curves but not the peak luminosities. The commonly used analytic formula based on rising bolometric light curves overestimates the ejecta mass of these high-initial-mass progenitor explosions by a factor of up to 2.6. In contrast, the calibrated method by Haynie et al., which relies on late-time decay tails, reduces uncertainties to an average of 20% within the calibrated ejecta mass range. Spectroscopically, the He I 1.083 μm line remains prominent even in models with as little as 0.02 M ⊙ of helium. However, the strength of the optical He I lines is not directly proportional to the helium mass but instead depends on a complex interplay of factors such as the 56 Ni distribution, composition, and radiation field. Thus, producing realistic helium features requires detailed radiative transfer simulations for each new hydrodynamic model.

79 ASTRONOMY AND ASTROPHYSICS

Exploding Bridgewire (EBW) Detonators: An Example of Synergistic Multiphysics

Exploding bridgewire (EBW) detonators are highly temporally reproducible explosive devices that require the rapid discharge of a high‐voltage capacitance to operate and so are immune to most of the accidental hazards associated with traditional electric detonators. They have been demonstrated to be safe enough for use in high‐consequence explosive applications. Despite continued use for over 82 years, understanding the exact mechanism of operation has remained elusive. Various researchers have ascribed either deflagration‐to‐detonation (DDT) or shock‐to‐detonation (SDT) phenomena observed in other explosive events to explain the science behind the successful engineering; however, a rigorous justification has been absent. Previously, we have demonstrated a complex interaction in EBW detonators between large electrical currents, non‐equilibrium thermodynamic material states, plasma physics, powder compaction phenomena, shock physics, photochemistry, and rapid conventional explosive chemical reaction processes. Specifically, we have made progress in understanding the complex multiphysics that operates in these detonators and demonstrating that it is a serendipitous synergy between UV light emitted from the arc formed as the bridge is electrically exploded and the accompanying short‐duration shock transmitted into the explosive powder bed that allows these devices to function at practical capacitor sizes and charge voltages. This insight not only places the topic on a firmer scientific footing but potentially enables new approaches to safe detonator design.

36 MATERIALS SCIENCE

The effect of dogbone sample size in the tensile testing of TATB-based plastic‑bonded explosive materials

Mechanical properties are of interest for many plastic‑bonded explosive (PBX) materials with tensile properties being of particular interest. Direct tensile measurements using dogbone-shaped samples are considered the gold standard, but they are fairly large, making testing more costly and less desirable from a safety perspective. We investigated whether the measured tensile strength depends on the dogbone specimen size, which to our knowledge, has not been reported in the literature for PBX materials. Understanding this should inform the feasibility of employing smaller samples and how sample size should be considered when comparing PBX dogbone values in the literature. The TATB-based PBX dogbone sample size was varied by (a) scaling all dimensions proportionally and (b) varying only the length of the samples. It was observed that the measured tensile peak stress (strength) was a function of the sample size, and was more dependent on the diameter (cross-sectional area) than the length of the samples. Since peak stress is calculated as peak force normalized to the diameter of the sample, one might not expect an explicit diameter dependence for the peak stress. Therefore, these results suggest there may be an additional strengthening effect as the sample diameter is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH