Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Charging a Battery-Powered Device with a Fiber-Optically Connected Photonic Power System for Achieving High-Voltage Isolation

This paper describes the development and testing of a system to provide isolated power to the cathode-subsystem electronics of an x-ray tube. These components are located at the cathode potential of several hundred kilovolts, requiring a supply of power isolated from this high voltage. In this design a fiber-optically connected photonic power system (PPS) is used to recharge a lithium-ion battery pack, which will subsequently supply power to the cathode-subsystem electronics. The suitability of the commercially available JDSU PPS for this application is evaluated. The output of the ppe converter is characterized. The technical aspects of its use for charging a variety of Li-Ion batteries are discussed. Battery charge protection requirements and safety concerns are also addressed.

47 OTHER INSTRUMENTATION↗

Design, Fabrication and Testing of a Superconducting Fault Current Limiter (SFCL)

The purpose of this project was to conduct R&D on specified components and provide technical design support to a SuperPower team developing a high temperature superconducting Fault Current Limiter (SFCL). ORNL teamed with SuperPower, Inc. on a Superconductivity Partnerships with Industry (SPI) proposal for the SFCL that was submitted to DOE and approved in FY 2003. A contract between DOE and SuperPower, Inc. was signed on July 14, 2003 to design, fabricate and test the SFCL. This device employs high temperature superconducting (HTS) elements and SuperPower's proprietary technology. The program goal was to demonstrate a device that will address a broad range of the utility applications and meet utility industry requirements. This DOE-sponsored Superconductivity Partnership with Industry project would positively impact electric power transmission reliability and security by introducing a new element in the grid that can significantly mitigate fault currents and provide lower cost solutions for grid protection. The project will conduct R&D on specified components and provide technical design support to a SuperPower-led team developing a SFCL as detailed in tasks 1-5 below. Note the SuperPower scope over the broad SPI project is much larger than that shown below which indicates only the SuperPower tasks that are complementary to the ORNL tasks. SuperPower is the Project Manager for the SFCL program, and is responsible for completion of the project on schedule and budget. The scope of work for ORNL is to provide R&D support for the SFCL in the following four broad areas: (1) Assist with high voltage subsystem R&D, design, fabrication and testing including characterization of the general dielectric performance of LN2 and component materials; (2) Consult on cryogenic subsystem R&D, design, fabrication and testing; (3) Participate in project conceptual and detailed design reviews; and (4) Guide commercialization by participation on the Technical Advisory Board (TAB). SuperPower's in-kind work for the SFCL will be provided in the following areas: (1) Work with ORNL to develop suitable test platforms for the evaluation of subsystems and components; (2) Provide cryogenic and high voltage subsystem designs for evaluation; (3) Lead the development of the test plans associated with the subsystem and components and participate in test programs at ORNL; and (4) Based on the test results, finalize the subsystem and component designs and incorporate into the respective SFCL prototypes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel insights into ascorbate retention and degradation during the washing and post-harvest storage of spinach and other salad leaves

Post-harvest treatments of pre-packaged salad leaves potentially cause l-ascorbate loss, but the mechanisms of ascorbate degradation remain incompletely understood, especially in planta . We explored the extent and pathways of ascorbate loss in variously washed and stored salad leaves. Ascorbate was assayed by 2,6-dichlorophenolindophenol titration, and pathways were monitored by 14 C-radiolabelling followed by high-voltage electrophoresis. All leaves tested showed ascorbate loss during storage: lettuce showed the greatest percentage loss, wild rocket the least. Spinach leaves were particularly prone to losing ascorbate during washing, especially with simultaneous mechanical agitation; however, washing in the presence of hypochlorite did not significantly increase ascorbate loss. In spinach, [ 14 C]oxalate was the major product of [ 14 C]ascorbate degradation, suggesting that commercial washing causes oxidative stress. This study highlights that ascorbate/dehydroascorbic acid are lost via the oxidative pathway during washing and post-harvest storage of salad leaves. Thus changes to washing procedures could potentially increase the post-harvest retention of ascorbate.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of a lightning protection system for a fusion-welded thermoplastic composite wind turbine blade tip

Fusion welding for thermoplastic composite wind turbine blades is being investigated as a replacement for adhesives in bond lines to reduce manufacturing time and cost and to promote ease of recyclability. Resistance welding uses an electrically conductive material, such as carbon fiber, embedded in the bond line to heat the joining surfaces and fuse them together under pressure. One main challenge with fusion joining for large wind blades is the ability to use this conductive heating element in the bond line while still protecting the blade from the catastrophic effects of a lightning strike. This paper outlines the design and manufacturing of a lightning protection system for a 5-m-long thermally welded blade tip. The outcomes of high voltage and high current lightning testing applied to the 5 m blade tip show that the proposed design was able to protect the fusion welded bond lines from significant lightning damage.

17 WIND ENERGY↗

Chemical Free Surface Processing for High Gradient Superconducting RF Cavities

Chemical treatment such as buffered chemical polishing (BCP) or electro polishing (EP) followed by high pressure rinsing (HPR) of niobium (Nb) superconducting RF (SRF) cavities is expensive and complex multistep process. Furthermore, the cavity RF surfaces after the treatment still have numerous bubbles and pits that result from welding. These quench-producing weld defects together with the particulate contamination, result in significant scatter of the multi-cell Nb SRF cavities performance characteristics. This scatter is the major problem in the current manufacturing of the Nb SRF cavities. When developed the chemical free surafce processing using IEB will benefit first J-lab's CEBAF and Fermilab's Project X. Also, light sources, require 1.3 - 1.5 GHz SRF structures. Furthermore, IEB will produce much broader impact because it can be implemented into manufacturing of many other types of RF devices including both superconducting as well as normal conducting RF cavities. This program will develop a new process that will enhance quality of the superconducing radio-frequency cavities and allow acceleration of charged particles to much higher energies. The process also will improve the cavity manufacturing and result in substantial cost reduction of superconducting radio-frequency high-energy particle accelerators. Niobium samples were successfully processed by a DC electron beam to a degree that is suitable for the interior surface of an SRF cavity. To accomplish this, a complete system was developed from the ground up. A vacuum chamber system was acquired and adapted to act as the vessel for performing the Nb processing experiments. An extremely robust high voltage power supply was developed and manufactured to provide the power necessary to drive the multi-kW DC electron gun. A high voltage isolation filament transformer was also designed and manufactured to provide the necessary current to drive the filament within the electron gun. Finally, a beam melt characterization DC electron gun was created. This gun was used to explore the parameter space of interest for processing Nb SRF cavities. The beam melt characterization tests concluded that multiple quick passes at moderate beam power provided the most ideal melt zone characteristics Nb surfaces. It was also found that excellent melt and polish results could be achieved at lower voltages than originally conceived, getting the great results at a beam voltage of 20kV versus the 50kV used in the initial Phase I testing at Jefferson Laboratory. Operating at 20kV will also greatly reduce the challenges of designing a compact DC electron gun for processing of complete Nb SRF cavities, which will be done in Phase III. This final report is divided in eight parts which cover the major investigation work and results which have been performed and achieved. The first part addresses the design, fabrication and testing of the vacuum chamber. In the second part, the DC power supply output circuit design is presented for providing an operating space of 50-60kV with currents from 20-160mA and short and open circuit fault modes are considered and resolved. The third section covers testing and commissioning of the high voltage step up transformer and 150kV isolation transformer. Section four covers the design, construction and performance for a 100kV high voltage bushing. Section number five treats the filament design and load testing. Section number six covers electron gun design and simulation of electron beam melting. Section seven presents the beam target design, assembly and testing and test gun with solenoid magnet, design, fabrication and testing. Finally, section eight demonstrates electron beam melting and polishing of Nb, Cu and SS samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DC buffering and floating current for a high voltage IMB application

An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

25 ENERGY STORAGE↗

Design and testing of a high perveance sheet beam electron gun

This paper presents the design, prototype engineering, and initial testing of a relatively low-voltage, high aspect ratio electron gun for versatile pulsed power applications. The sheet beam, diode electron gun is designed for (23–25) kV voltage and 6 µA/V1.5, as is required for x-band klystron, as a part of a compact Klylac delivering electron beam energy in the MeV range. The gun prototype was engineered, built, and tested using a Scandinova M1-0.5 modulator. Beam loss on the anode aperture is evaluated from transient waveforms and equivalent circuit modeling.

Instruments & Instrumentation↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

30 DIRECT ENERGY CONVERSION↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

A Modular SiC High-Frequency Solid-State Transformer for Medium-Voltage Applications: Design, Implementation, and Testing

The advancements in wide-bandgap devices are enabling applications of power electronic converters coupled directly with medium-voltage (MV) grids that incorporate galvanic isolation within the converter using high-frequency solid-state transformers (SSTs). This paper presents analysis, design, and the characterization results of a 50-kVA modular soft-switched ac-ac SST using silicon carbide (SiC) MOSFET for MV (>6 kV ac) applications. Here, the SST is comprised of two hard-switched ac-line interface bridges and a resonant dc-dc stage switched at approximately 180 kHz. To minimize the cost of switching elements per ampere and maximize the design flexibility, the design uses multiple discrete SiC devices of, readily available, 1700-V ratings. This paper covers the analysis of soft-switching operation, control architecture, converter design, and system-level integration.

17 WIND ENERGY↗

A Prototype High-Voltage Pulsed Power Supply for Control of the ITER Shattered Pellet Injection System Flyer Plate Valve

A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Enabling High-Energy, High-Voltage Lithium-Ion Cells: Standardization of Coin-Cell Assembly, Electrochemical Testing, and Evaluation of Full Cells

Coin-cells are often the test format of choice for laboratories engaged in battery research and development as they provide a convenient platform for rapid testing of new materials on a small scale. However, reliable, reproducible data via the coin-cell format is inherently difficult, particularly in the full-cell configuration. In addition, statistical evaluation to prove the consistency and reliability of such data is often neglected. Herein we report on several studies aimed at formalizing physical process parameters and coin-cell construction related to full cells. Statistical analysis and performance benchmarking approaches are advocated as a means to more confidently track changes in cell performance. Finally, we show that trends in the electrochemical data obtained from coin-cells can be reliable and informative when standardized approaches are implemented in a consistent manner.

25 ENERGY STORAGE↗

Sterile Neutrinos in Cold Climates

Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90\% confidence level exclusion limit extends to $\mathrm{sin}^2 2\theta_{24} \leq 0.02$ at $\Delta m^2 \sim 0.3\,eV^2$, and the LSND and MiniBooNE allowed regions are excluded at~>99\% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗