Search NASA⌕ Search

SEARCH · Search NASA

Results for “High heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High Heat Flow from Enceladus' South Polar Region Measured using 10-600/cm(exp -1) Cassini/CIRS Data

Analysis of 2008 Cassini Composite Infrared Spectrometer (CIRS) 10 to 600/cm thermal emission spectra of Enceladus shows that for reasonable assumptions about the spatial distribution of the emission and the thermophysical properties of the solar-heated background surface, which are supported by CIRS observations of background temperatures at the edge of the active region, the endogenic power of Enceladus' south polar terrain is 15.8 +/- 3.1 GW. This is significantly higher than the previous estimate of 5.8 +/- 1.9 GW. The new value represents an improvement over the previous one, which was derived from higher wave number data (600 to 1100/cm-I) and was thus only sensitive to high-temperature emission. The mechanism capable of producing such a high endogenic power remains a mystery and challenges the current models of proposed heat production.

Howett, C. J. A.↗

Charlo Junior High Heating, Ventilation, and Air Conditioning (HVAC) Upgrade and Energy Improvements

The Charlo School District 7J is located at 404 1st Ave West, in Charlo, Montana. The District has 55,778 ft² of facility space serving students from grades K through 12 in the Western Montana community of Charlo, within the Flathead Indian Reservation. The campus is made up of four primary buildings which are the elementary building, administration and high school, a junior high wing with a shop, and the gymnasium/multipurpose building. This project will focus on the needs of the Junior High Facility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hermeticity of SiC/SiC composite and monolithic SiC tubes irradiated under radial high-heat flux

Demonstration of hermetic SiC fiber–reinforced SiC matrix composite cladding under normal operating environments has been identified as one of the most critical feasibility issues for accident-tolerant fuel cladding in light-water reactors. This study provides critical experimental data needed for understanding the effects of irradiation on hermeticity. SiC composite and monolithic tubes were neutron-irradiated to 2 displacements per atom with and without a nominal radial heat flux of 0.6 MW/m2 to produce a simulated in-pile stress state for the normal operation of a light-water reactor. The through-thickness temperature gradient under irradiation results in a gradient in swelling, which causes a significant stress buildup. Such irradiation-induced stress was modeled using a commercial finite element analysis code. The radial heat flux–irradiation synergism was experimentally investigated by constructing a special irradiation capsule and evaluating the helium hermeticity of the specimens. The simulated stress state exhibited a near equi-biaxial tensile axial and hoop stress of ~150 MPa at the inner surface of the SiC composite tube. This stress level is potentially beyond the matrix cracking stress. Degradation of hermeticity of the SiC composite tubes was observed after irradiation, indicating irradiation-induced cracking, whereas the irradiated monolithic SiC tubes remained hermetic. In conclusion, the results indicate that loss of hermeticity caused by radiation-induced microcracking is a potential issue for SiC composite cladding, depending on the magnitude of the temperature gradients. Coating the outer surface of the cladding was identified as a mitigation strategy that might overcome the cracking issue.

36 MATERIALS SCIENCE↗

Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads

The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ammonium perchlorate gasification and combustion at high heating rates and low pressures.

Mass-spectrometric and linear regression rate characterizations are reported, derived from CO2 laser pyrolyses of pressed NH2ClO4 (AP) at incident heat fluxes ranging from 25 to 4000 cal/sq cm sec. Product evolution-rate histories were obtained in vacuo by time-resolved (5 msec) mass spectrometry during (1) transient heat-up, and (2) subsequent quasi-steady vaporization (QSV). Vaporization induction times were obtained for (1); these, coupled with heat-transfer approximations neglecting thermochemical heat release, indicated that optical absorption at 10.6 microns dominated over conduction for heat fluxes much greater than 300. Conclusions applying in vacuo were: preferential desorption of NH3, with net accumulation of adsorbed HClO4, occurred during transient heat-up and onset of condensed phase decomposition (CPD), but preferential decomposition of adsorbed HClO4 (compared to NH3) occurred during QSV when CPD was significant. CPD was the dominant mode of QSV at moderate heat fluxes.

Pellett, G. L.↗

High heat flux actively cooled honeycomb sandwich structural panel for a hypersonic aircraft

The results of a program to design and fabricate an unshielded actively cooled structural panel for a hypersonic aircraft are presented. The design is an all-aluminum honeycomb sandwich with embedded cooling passages soldered to the inside of the outer moldline skin. The overall finding is that an actively cooled structure appears feasible for application on a hypersonic aircraft, but the fabrication process is complex and some material and manufacturing technology developments are required. Results from the program are summarized and supporting details are presented.

Koch, L. C.↗

Conventionally cast and forged copper alloy for high-heat-flux thrust chambers

The combustion chamber liner of the space shuttle main engine is made of NARloy-Z, a copper-silver-zirconium alloy. This alloy was produced by vacuum melting and vacuum centrifugal casting; a production method that is currently now available. Using conventional melting, casting, and forging methods, NASA has produced an alloy of the same composition called NASA-Z. This report compares the composition, microstructure, tensile properties, low-cycle fatigue life, and hot-firing life of these two materials. The results show that the materials have similar characteristics.

Kazaroff, John M.↗

Computation of full-coverage film-cooled airfoil temperatures by two methods and comparison with high heat flux data

Two methods were used to calculate the heat flux to full-coverage film cooled airfoils and, subsequently, the airfoil wall temperatures. The calculated wall temperatures were compared to measured temperatures obtained in the Hot Section Facility operating at real engine conditions. Gas temperatures and pressures up to 1900 K and 18 atm with a Reynolds number up to 1.9 million were investigated. Heat flux was calculated by the convective heat transfer coefficient adiabatic wall method and by the superposition method which incorporates the film injection effects in the heat transfer coefficient. The results of the comparison indicate the first method can predict the experimental data reasonably well. However, superposition overpredicted the heat flux to the airfoil without a significant modification of the turbulent Prandtl number. The results suggest that additional research is required to model the physics of full-coverage film cooling where there is significant temperature/density differences between the gas and the coolant.

Gladden, H. J.↗