Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the OECD/NEA PWR MOX/UO{sub 2} core transient benchmark using a coupled whole core pin-by-pin route in WIMS

This paper investigates the new CAMELOT coupling route developed in WIMS, which uses prepared tabulated cross-sections combined with the flux solver MERLIN module and the integrated sub-channel thermal hydraulics solver ARTHUR module to solve for the coupled core state. This coupling route is applied to the OECD/NEA pressurized water reactor (PWR) core transient benchmark exercise, involving 3-D neutronics and thermal-hydraulics analysis of a full-sized PWR core featuring MOX fuel at various core states, as well as simulating a control rod ejection transient. Analysis of the results for each part of the benchmark demonstrate that the high-resolution pin-by-pin analysis used in WIMS closely matches the other participants in the benchmark, with differences of between 20-200 pcm for k-effective, 1-2.5% RMS difference for assembly-averaged powers, 2-8% difference in rod worth calculations, < 200 ppm for calculations of critical boron concentration, zero difference in delayed neutron fraction calculation and a very close match for power response to the rod ejection transient. This is the first application of the WIMS-CAMELOT approach for the transient analysis of a full-sized reactor and as such further improvements such as reducing computational cost through parallelization, optimisation and memory reduction, are currently in active development. This paper demonstrates the accuracy and flexibility of the CAMELOT coupling route, providing a straightforward and consistent user image that can be easily used for a variety of modelling problems involving coupled neutronics and thermal-hydraulics. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fabrication of Black Body Grids by Thick Film Printing for Quantitative Neutron Imaging

Neutron imaging offers deep penetration through many high-Z materials while also having high sensitivity to certain low-Z isotopes such as 1H, 6Li, and 10B. This unique combination of properties has made neutron imaging an attractive tool for a wide range of material science and engineering applications. However, measurements made by neutron imaging or tomography are generally qualitative in nature due to the inability of detectors to discriminate between neutrons which have been transmitted through the sample and neutrons which are scattered by the sample or within the detector. Recent works have demonstrated that deploying a grid of small black bodies (BBs) in front of the sample can allow for the scattered neutrons to be measured at the BB locations and subsequently subtracted from the total measured intensity to yield a quantitative transmission measurement. While this method can be very effective, factors such as the scale and composition of the sample, the beam divergence, and the resolution and construction of the detector may require optimization of the grid design to remove all measurement biases within a given experimental setup. Therefore, it is desirable to have a method by which BB grids may be rapidly and inexpensively produced such that they can easily be tailored to specific applications. In this work, we present a method for fabricating BB patterns by thick film printing of Gd2O3 and evaluate the performance with variation in feature size and number of print layers with cold and thermal neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

A JWST Survey of the Supernova Remnant Cassiopeia A

We present initial results from a James Webb Space Telescope (JWST) survey of the youngest Galactic core-collapse supernova remnant, Cassiopeia A (Cas A), made up of NIRCam and MIRI imaging mosaics that map emission from the main shell, interior, and surrounding circumstellar/interstellar material (CSM/ISM). We also present four exploratory positions of MIRI Medium Resolution Spectrograph integral field unit spectroscopy that sample ejecta, CSM, and associated dust from representative shocked and unshocked regions. Surprising discoveries include (1) a weblike network of unshocked ejecta filaments resolved to ~0.01 pc scales exhibiting an overall morphology consistent with turbulent mixing of cool, low-entropy matter from the progenitor's oxygen layer with hot, high-entropy matter heated by neutrino interactions and radioactivity; (2) a thick sheet of dust-dominated emission from shocked CSM seen in projection toward the remnant's interior pockmarked with small (~1'') round holes formed by ≲0$^"_•$1 knots of high-velocity ejecta that have pierced through the CSM and driven expanding tangential shocks; and (3) dozens of light echoes with angular sizes between ~0$^"_•$1 and 1' reflecting previously unseen fine-scale structure in the ISM. NIRCam observations place new upper limits on infrared emission (≲20 nJy at 3 μm) from the neutron star in Cas A's center and tightly constrain scenarios involving a possible fallback disk. These JWST survey data and initial findings help address unresolved questions about massive star explosions that have broad implications for the formation and evolution of stellar populations, the metal and dust enrichment of galaxies, and the origin of compact remnant objects.

79 ASTRONOMY AND ASTROPHYSICS↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Test Bench (SYSM 5620 Final Report)

The National Ignition Facility (NIF) is a research facility that focuses on High Energy Density Science and Inertial Confinement Fusion. In the NIF, 192 laser beams are directed into a miniscule Target Capsule to generate an implosion – this is called a NIF Shot. Many NIF Users conduct experiments using different Targets and laser inputs to generate reactions that are of interest to the scientific community. Those reactions are monitored using various Target Diagnostic instruments, including Shot Time Photography – which provides crucial images of the Target as the implosion occurs. A subset of these NIF Users is less interested in the reaction itself and more interested in subjecting materials or devices to the intense environment that these reactions can create. Using the Target as a source of x-rays, neutrons, or blast loading for particular materials has been significant to the shock physics community and to those who work in extreme design spaces. However, the Material and Radiation Effects team – that performs these experiments on behalf of the NIF Users – has not been able to make good use of the existing Shot Time Photography Diagnostics. The STP cameras are focused on the Targets rather than the MRE Customers’ materials, the current system is not oriented to have a good view of the MRE Customers’ materials, and the cameras are limited in their capabilities (black and white, poor resolution, etc.). As MRE experiments increase in quantity and importance to the scientific community, the desire for visual monitoring of the experiments to substantiate models and inform other data is also rising.

42 ENGINEERING↗

The High Energy X-ray Probe (HEX-P): supernova remnants, pulsar wind nebulae, and nuclear astrophysics

HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (< 10" full width at half maximum) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. HEX-P is ideally suited to address important problems in the physics and astrophysics of supernova remnants (SNRs) and pulsar wind nebulae (PWNe). For shell SNRs, HEX-P can greatly improve our understanding via more accurate spectral characterization and localization of non-thermal X-ray emission from both non-thermal-dominated SNRs and those containing both thermal and non-thermal components, and can discover previously unknown non-thermal components in SNRs. Multi-epoch HEX-P observations of several young SNRs (e.g., Cas A and Tycho) are expected to detect year-scale variabilities of X-ray filaments and knots, thus enabling us to determine fundamental parameters related to diffusive shock acceleration, such as local magnetic field strengths and maximum electron energies. For PWNe, HEX-P will provide spatially-resolved, broadband X-ray spectral data separately from their pulsar emission, allowing us to study how particle acceleration, cooling, and propagation operate in different evolution stages of PWNe. HEX-P is also poised to make unique and significant contributions to nuclear astrophysics of Galactic radioactive sources by improving detections of, or limits on, 44Ti in the youngest SNRs and by potentially discovering rare nuclear lines as evidence of double neutron star mergers. Throughout the paper, we present simulations of each class of objects, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of SNRs, PWNe, and nuclear astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

The dynamics, mixing, and thermonuclear burn of compressed foams with varied gas fills

Inertial confinement fusion (ICF) implosions involve highly coupled physics and complex hydrodynamics that are challenging to model computationally. Due to the sensitivity of such implosions to small features, detailed simulations require accurate accounting of the geometry and dimensionality of the initial conditions, including capsule defects and engineering features such as fill tubes used to insert gas into the capsule, yet this is computationally prohibitive. It is therefore difficult to evaluate whether discrepancies between the simulation and experiment arise from inadequate fidelity to the capsule geometry and drive conditions, uncertainties in physical data used by simulations, or inadequate physics. We present results from detailed high-resolution three-dimensional simulations of ICF implosions performed as part of the MARBLE campaign on the National Ignition Facility [Albright et al., Phys. Plasmas 29, 022702 (2022)]. These experiments are foam-filled separated-reactant experiments, where deuterons reside in the foam and tritons reside in the capsule gas fill and deuterium–tritium (DT) fusion reactions only occur in the presence of mixing between these materials. Material mixing in these experiments is primarily seeded by shock interaction with the complex geometry of the foam and gas fill, which induces the Richtmyer–Meshkov instability. We compare results for experiments with two different gas fills (ArT and HT), which lead to significant differences in the hydrodynamic and thermodynamic developments of the materials in the implosion. Our simulation results show generally good agreement with experiments and demonstrate a substantial impact of hydrodynamic flows on measured ion temperatures. The results suggest that viscosity, which was not included in our simulations, is the most important unmodeled physics and qualitatively explains the few discrepancies between the simulation and experiment. The results also suggest that the hydrodynamic treatment of shocks is inadequate to predict the heating and yield produced during shock flash, when the shock converges at the center of the implosion. Alternatively, underestimation of the level of radiative preheat from the shock front could explain many of the differences between the experiment and simulation. Nevertheless, simulations are able to reproduce many experimental observables within the level of experimental reproducibility, including most yields, time-resolved X-ray self-emission images, and an increase in burn-weighted ion temperature and neutron down-scattered ratio in the line of sight that includes a jet seeded by the glue spot that joins capsule hemispheres.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗