Search NASASearch

SEARCH · Search NASA

Results for “High-resolution electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,398 records · Page 5

Impact of End Effector Technology on Telemanipulation Performance

Generic requirements for end effector design are briefly summarized as derived from generic functional and operational requirements. Included is a brief summary of terms and definitions related to end effector technology. The second part contains a brief overview of end effector technology work as JPL during the past ten years, with emphasis on the evolution of new mechanical, sensing and control capabilities of end effectors. The third and major part is devoted to the description of current end effector technology. The ongoing work addresses mechanical, sensing and control details with emphasis on mechanical ruggedness, increased resolution in sensing, and close electronic and control integration with overall telemanipulator control system.

A K Bejczy

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U

Heat Capacity and Thermal Relaxation of Bulk Helium Very Near the Lambda Point

In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10 -10 K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.

John A Lipa

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN

Multi-Resolution UAV Path Replanning for Inspection of Tailings Dams

Autonomous inspection of large and complex structures with a commercial unmanned aerial vehicle (UAV) is a challenging problem that has been addressed in recent years. In this paper, we address the global motion planning problem of creating autonomous inspection missions for UAVs considering photogrammetry constraints. We focus on the inspection of large tailings dams, which are dam structures used to store waste byproducts of mining. Our method uses a prior sparse point cloud of the dam to generate a voxel grid, where paths satisfying photogrammetry constraints are tested for collisions. We then apply the A* algorithm as a local planner to avoid obstacles within the global mission. Moreover, we address the problem of changing routes online by using octree-based multi-resolution grids for efficient and fast pathfinding. Our results, obtained using tridimensional maps of an actual coal mine tailings dam, show that using octrees for multi-resolution motion planning is faster than using a fixed voxel grid in online missions while inspecting large structures.

42 ENGINEERING

Characterization of Ternary NiTiPt High-Temperature Shape Memory Alloys

Pt additions substituted for Ni in NiTi alloys are known to increase the transformation temperature of the alloy but only at fairly high Pt levels. However, until now only ternary compositions with a very specific stoichiometry, Ni 50-x Pt x Ti 50 , have been investigated and then only to very limited extent. In order to learn more about this potential high-temperature shape memory alloy system, a series of over twenty alloys along and on either side of a line of constant stoichiometry between NiTi and TiPt were arc melted, homogenized, and characterized in terms of their microstructure, transformation temperatures, and hardness. The resulting microstructures were examined by scanning electron microscopy and the phase compositions quantified by energy dispersive spectroscopy. "Stoichiometric" compositions along a line of constant stoichiometry between NiTi to TiPt were essentially single phase but any deviations from a stoichiometry of (Ni,Pt) 50 Ti 50 resulted in the presence of at least two different intermetallic phases, depending on the overall composition of the alloy. Essentially all alloys, whether single or two-phase, still under went a martensitic transformation. It was found that the transformation temperatures were depressed with initial Pt additions but at levels greater than 10 at.% the transformation temperature increased linearly with Pt content. Also, the transformation temperatures were relatively insensitive to alloy stoichiometry within the range of alloys examined. Finally, the dependence of hardness on Pt content for a series of Ni 50-x Pt x Ti 50 alloys showed solution softening at low Pt levels, while hardening was observed in ternary alloys containing more than about 10 at.% Pt. On either side of these "stoichiometric" compositions, hardness was also found to increase significantly.

Transformation Temperatures

3D Printing of Polyelectrolyte Complex-Integrated Photocurable Hydrogel Resins

In this study, we developed a photocurable hydrogel resin incorporating a polyelectrolyte complex (PEC) for 3D printing. Acrylamide-based monomers were formulated with varying PEC contents (0–15 wt %) in an aqueous KBr medium to fabricate patterned porous hydrogel structures. The morphology of printed hydrogels was characterized by field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy. Notably, the PEC5 and PEC10 formulations exhibited optimal thermal stability and compressive properties, attributed to the homogeneous distribution of PEC domains within the hydrogel matrix. Furthermore, dye adsorption experiments demonstrated excellent removal efficiency, highlighting the potential of PEC-containing hydrogels for environmental remediation applications, particularly in the treatment of dye-contaminated wastewater.

Yang, Jinchul [University of Tennesse Knoxville]

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas

Influence of Processing Parameters on the Mechanical Properties of 3D Printed Borosilicate Particulate Reinforced Polymer Composites

Emerging composite materials are expanding the potential of additive manufacturing and enabling applications previously restricted by traditional manufacturing methods. The multi-phase nature of these composite materials combined with the complex in-ternal geometry of additively manufactured parts have enabled unique behavior, and potentially new applications. Additionally, these materials can be pyrolyzed to create dense metal, ceramic, and glass parts with geometries typically not achievable by tra-ditional processes. Additive manufacturing of borosilicate glass-based systems can open new applications in nuclear engineering, astronomy, and bone regrowth therapy. To elucidate the process-parameter relationship of borosilicate-polylactic acid (PLA) composites, mechanical testing was conducted and compared with a pure polylactic acid polymer baseline. Test specimens were fabricated by fused-filament fabrication with minimal post-processing. Yield strength, ultimate strength, and elastic modulus were calculated from stress-strain curves. Optical and scanning electron microscopy were conducted to observe the specimen microstructure before and after testing. The highest compressive yield strength for the composite was 28.22 MPa, and the highest compressive yield strength for PLA was 49.30 MPa. Print orientation was found to benefit the composite material but have a detrimental effect on the pure matrix material. An elastic modulus of 2.66 GPa was recorded for the borosilicate-PLA composite at 100% infill, 1 shell wall, and layer lines parallel to compression axis. Microscopy revealed that lower modulus composite specimens had the particulates re-distributed within the matrix. Tensile testing was done according to a polymer testing standard, which caused difficulties obtaining consistent fracture within the gauge length.

mechanical testing

Biobased Polybenzoxazine Derived from Furfurylamine and Piceol with Low Cure Temperature and Advanced Properties for Composite Matrices

A novel benzoxazine made from furfurylamine, paraformaldehyde, and piceol, Bz-FA-HA, is assessed for applications in fiber reinforced (FR) composites. Piceol is a biobased phenolic compound derived from the roots of Norwegian spruce trees and contains a methyl ketone group at the para position. Bz-FA-HA is a liquid at room temperature, has a viscosity of < 1 Pa.s at temperatures above 90 °C, and a Tonset of cure at 132 °C. The carbonyl is found to react with the furan ring, yielding a crosslinking reaction, when cured above 180 °C as indicated by differential scanning calorimetry and thermogravimetric analysis coupled with Fourier transform infrared spectroscopy. Poly(Bz-FA-HA) has a Tg > 350 °C, attributed to the crosslinking reaction. Furthermore, the storage modulus is > 3 GPa, regardless of cure temperature. Poly(Bz-FA-HA) has a char yield at 800 °C of 65.0 % (62.3 % at 1000 °C), and a Tonset of decomposition of 357 °C in nitrogen. The resulting carbon formed during pyrolysis shrinks during the carbonization reaction and scanning electron microscopy imaging shows a cross-section with micro cracks. The high processability, advanced mechanical properties, and exceptional char yield make it a promising candidate as the matrix for FR composites.

Benzoxazine

Strain and Defect-Tailored Magnetotransport in NiCo 2 O 4 Thin Films and Freestanding Membranes

Magnetic spinel NiCo 2 O 4 is promising for developing spintronic applications due to its high magnetic Curie temperature, high spin polarization, fast spin dynamics, and strain-tunable magnetic anisotropy, while its electronic and magnetic properties depend sensitively on epitaxial strain and disorder. Here, in this study, we use epitaxial NiCo 2 O 4 thin films and freestanding NiCo 2 O 4 membranes as model systems to reveal the complex interplay of strain and defects in determining the metallicity and magnetotransport properties of the ferrimagnetic spinel. NiCo 2 O 4 on perovskite substrates and NiCo 2 O 4 membranes exhibit insulating behaviors and spin canting, in sharp contrast to the metallic NiCo 2 O 4 films on spinel substrates that possess strong perpendicular magnetic anisotropy. Anisotropic magnetoresistance studies provide critical information about disorder-induced spin scattering and strain-induced tetragonal magnetocrystalline anisotropy, which is corroborated by comprehensive electron microscopy characterizations. Our study presents a promising venue for designing flexible magnetic memory, sensor, and spintronic applications.

36 MATERIALS SCIENCE

Super-resolution imaging reveals resistance to mass transfer in functionalized stationary phases

Chemical separations are costly in terms of energy, time, and money. Separation methods are optimized with inefficient trial-and-error approaches that lack insight into the molecular dynamics that lead to the success or failure of a separation and, hence, ways to improve the process. We perform super-resolution imaging of fluorescent analytes in five different commercial liquid chromatography materials. Unexpectedly, we observe that chemical functionalization can block more than 50% of the material’s porous interior, rendering it inaccessible to small-molecule analytes. Only in situ imaging unveils the inaccessibility when compared to the industry-accepted ex situ characterization methods. Selectively removing some of the functionalization with solvent restores pore access without substantially altering the single-molecule kinetics that underlie the separation and agree with bulk chromatography measurements. Our molecular results determine that commercial “fully porous” stationary phases are over-functionalized and provide an alternative avenue to characterize and direct separation material design from the bottom-up.

Science & Technology - Other Topics

Eliminating chemo-mechanical degradation of lithium solid-state battery cathodes during >4.5 V cycling using amorphous Nb2O5 coatings

Abstract Lithium solid-state batteries offer improved safety and energy density. However, the limited stability of solid electrolytes (SEs), as well as irreversible structural and chemical changes in the cathode active material, can result in inferior electrochemical performance, particularly during high-voltage cycling (>4.3 V vs Li/Li + ). Therefore, new materials and strategies are needed to stabilize the cathode/SE interface and preserve the cathode material structure during high-voltage cycling. Here, we introduce a thin (~5 nm) conformal coating of amorphous Nb 2 O 5 on single-crystal LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathode particles using rotary-bed atomic layer deposition (ALD). Full cells with Li 4 Ti 5 O 12 anodes and Nb 2 O 5 -coated cathodes demonstrate a higher initial Coulombic efficiency of 91.6% ± 0.5% compared to 82.2% ± 0.3% for the uncoated samples, along with improved rate capability (10x higher accessible capacity at 2C rate) and remarkable capacity retention during extended cycling (99.4% after 500 cycles at 4.7 V vs Li/Li + ). These improvements are associated with reduced cell polarization and interfacial impedance for the coated samples. Post-cycling electron microscopy analysis reveals that the Nb 2 O 5 coating remains intact and prevents the formation of spinel and rock-salt phases, which eliminates intra-particle cracking of the single-crystal cathode material. These findings demonstrate a potential pathway towards stable and high-performance solid-state batteries during high-voltage operation.

Science & Technology - Other Topics