Search NASA⌕ Search

SEARCH · Search NASA

Results for “Home thermal model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

82 records · Page 5

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Proactive and Reactive Thermal Comfort Behaviors

The expansion of renewable electricity generation, growing demands due to electrification, greater prevalence of working from home, and increasing frequency and severity of extreme weather events, will place new demands on the electric supply and distribution grid. Broader adoption of demand response programs (DRPs) for the residential sector may help meet these challenges; however, experience shows that occupant overrides in DRPs compromises their effectiveness. There is a lack of formal understanding of how discomfort, routines, and other motivations affect DRP overrides and other related human building interactions (HBI). This paper reports preliminary findings from a study of 20 households in Colorado and Massachusetts, US over three months. Participants responded to ecological momentary assessments (EMA) triggered by thermostat interactions and at random times throughout the day. EMAs included Likert-scale questions of thermal preference, preference intensity, and changes to 7 different activity types that could affect thermal comfort, and an opened ended question about motivations of such actions. Twelve tags were developed to categorize motivation responses and analyzed statistically to identify associations between motivations, preferences, and HBI actions. Reactions to changes in the thermal environment were the most frequently observed motivation (118 of 220 responses). On the other hand, almost half (47%) responses were at least partially motivated by non-thermal factors, suggesting limited utility for occupant behavior models founded solely on thermal comfort. Changes in activity level and clothing were less likely to be reported when EMAs were triggered by thermostat interactions, while fan interactions were more likely. Windows, shades, and portable heater interactions had no significant dependence on how the EMA was triggered. These results suggest that better understanding of motivations for HBI may improve effectiveness of demand response programs.

Pathak, Maharshi↗

A New Look For Greenbelt

Greenbelt, Maryland, 12 miles from the nation's capital, is an efficiently planned model town and most of its 1600 homes are almost identical in appearance. Four of them, however, stand out from their neighbors; they have distinctive blue glass rooftop superstructures made up of a series of solar collectors. They are part of a NASA community aid program, a joint energy research project involving the Greenbelt housing cooperative and NASA's Goddard Space Flight Center, located near the community. Built in 1935, Greenbelt is one of three government-planned communities of President Franklin D. Roosevelt's first administration; the others are Greendale, Wisconsin and Greenhills, Ohio. The government built the towns to make available low-cost housing, provide employment for workers on relief in the Great Depression era, and to establish models designed to encourage construction of similar developments by private industry. In 1952, the residents of Greenbelt formed a nonprofit cooperative called Greenbelt Homes, Inc., which bought the dwellings, facilities and a large part of the land from the government. The homes are individually owned but collectively maintained by the co-op, with each owner paying a prorated share of utility and maintenance costs. Greenbelt residents are mostly in the low and medium income brackets, and one of every three families lives on a fixed retirement income. For that reason, the sharp escalation of fuel oil prices that began in 1973 imposed particular hardship on the co-op community. So Greenbelt Homes' management asked its NASA neighbor, Goddard Space Flight Center, for assistance in setting up a solar energy research project. The idea was to conduct a small scale demonstration to show what savings could be realized by solar heating Greenbelt homes, with an eye toward possible future expansion of solar energy systems as a means of combating rising fuel costs. Goddard undertook the project as part of the federal government's effort to research and demonstrate ways of conserving energy. The Center was well qualified for the assignment, having acquired extensive expertise in designing thermal control systems for satellites, which must maintain stable temperatures for successful operation.

Source record↗

Bird's Eye View - A 3-D Situational Awareness Tool for the Space Station

Even as space-qualified computer hardware lags well behind the latest home computers, the possibility of using high-fidelity interactive 3-D graphics for displaying important on board information has finally arrived, and is being used on board the International Space Station (ISS). With the quantity and complexity of space-flight telemetry, 3-D displays can greatly enhance the ability of users, both onboard and on the ground, to interpret data quickly and accurately. This is particularly true for data related to vehicle attitude, position, configuration, and relation to other objects on the ground or in-orbit Bird's Eye View (BEV) is a 3-D real-time application that provides a high degree of Situational Awareness for the crew. Its purpose is to instantly convey important motion-related parameters to the crew and mission controllers by presenting 3-D simulated camera views of the International Space Station (ISS) in its actual environment Driven by actual telemetry, and running on board, as well as on the ground, the user can visualize the Space Station relative to the Earth, Sun, stars, various reference frames, and selected targets, such as ground-sites or communication satellites. Since the actual ISS configuration (geometry) is also modeled accurately, everything from the alignment of the solar panels to the expected view from a selected window can be visualized accurately. A virtual representation of the Space Station in real time has many useful applications. By selecting different cameras, the crew or mission control can monitor the station's orientation in space, position over the Earth, transition from day to night, direction to the Sun, the view from a particular window, or the motion of the robotic arm. By viewing the vehicle attitude and solar panel orientations relative to the Sun, the power status of the ISS can be easily visualized and understood. Similarly, the thermal impacts of vehicle attitude can be analyzed and visually confirmed. Communication opportunities can be displayed, and line-of-sight blockage due to interference by the vehicle structure (or the Earth) can be seen easily. Additional features in BEV display targets on the ground and in-orbit, including cities, communication sites, landmarks, satellites, and special sites of scientific interest for Earth observation and photography. Any target can be selected and tracked. This gives the user a continual line-of-sight to the target of current interest, and real-time knowledge about its visibility. Similarly, the vehicle ground-track, and an option to show "visibility circles" around displayed ground sites, provide continuous insight regarding current and future visibility to any target BEV was designed with inputs from many disciplines in the flight control and operations community both at NASA and from the International Partners. As such, BEV is setting the standards for interactive 3-D graphics for spacecraft applications. One important contribution of BEV is a generic graphical interface for camera control that can be used for any 3-D applications. This interface has become part of the International Display and Graphics Standards for the 16-nation ISS partnership. Many other standards related to camera properties, and the display of 3-D data, also have been defined by BEV. Future enhancements to BEV will include capabilities related to simulating ahead of the current time. This will give the user tools for analyzing off-nominal and future scenarios, as well as for planning future operations.

Dershowitz, Adam↗

Multiple emission components in the Cygnus cocoon detected from Fermi -LAT observations

Star-forming regions may play an important role in the life cycle of Galactic cosmic rays (CRs), notably as home to specific acceleration mechanisms and transport conditions. Gamma-ray observations of Cygnus X have revealed the presence of an excess of hard-spectrum gamma-ray emission, possibly related to a cocoon of freshly accelerated particles. We seek an improved description of the gamma-ray emission from the cocoon using ~13 yr of observations with the Fermi-Large Area Telescope (LAT) and use it to further constrain the processes and objects responsible for the young CR population. We developed an emission model for a large region of interest, including a description of interstellar emission from the background population of CRs and recent models for other gamma-ray sources in the field. Thus, we performed an improved spectro-morphological characterisation of the residual emission including the cocoon. The best-fit model for the cocoon includes two main emission components: an extended component FCES G78.74+1.56, described by a 2D Gaussian of extension r 68 = 4.4° ± 0.1° -0.1° +0.1° and a smooth broken power law spectrum with spectral indices 1.67 ± 0.05 -0.01 +0.02 and 2.12 ± 0.02 -0.01 +0.00 below and above 3.0 ± 0.6 -0.2 +0.0 GeV, respectively; and a central component FCES G80.00+0.50, traced by the distribution of ionised gas within the borders of the photo-dissociation regions and with a power law spectrum of index 2.19 ± 0.03 -0.01 +0.00 that is significantly different from the spectrum of FCES G78.74+1.56. An additional extended emission component FCES G78.83+3.57, located on the edge of the central cavities in Cygnus X and with a spectrum compatible with that of FCES G80.00+0.50, is likely related to the cocoon. For the two brightest components FCES G80.00+0.50 and FCES G78.74+1.56, spectra and radial-azimuthal profiles of the emission can be accounted for in a diffusion-loss framework involving one single population of non-thermal particles with a flat injection spectrum. Particles span the full extent of FCES G78.74+1.56 as a result of diffusion from a central source, and give rise to source FCES G80.00+0.50 by interacting with ionised gas in the innermost region. For this simple diffusion-loss model, viable setups can be very different in terms of energetics, transport conditions, and timescales involved, and both hadronic and leptonic scenarios are possible. The solutions range from long-lasting particle acceleration, possibly in prominent star clusters such as Cyg OB2 and NGC 6910, to a more recent and short-lived release of particles within the last 10–100 kyr, likely from a supernova remnant. The observables extracted from our analysis can be used to perform detailed comparisons with advanced models of particle acceleration and transport in star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Computational and Experimental Investigation of Thermal-Mechanical- Chemical Mechanisms of High-burnup Spent Nuclear Fuel (SNF) Processes at Elevated Temperatures and Degradation Behavior in Geologic Repositories

The overarching goal of the combined computational and experimental R&D activities proposed in this project is to enhance understanding of the mechanisms and thermal-mechanical-chemical (TMC) parameters controlling the instant release fraction (IRF) and matrix dissolution of high-burnup (HB; burnup) spent nuclear fuels (SNFs) and the subsequent formation, stability, and phase transformations of SNF alteration products under long-term storage and geological disposal conditions. Uranium dioxide may undergo oxidative corrosion/alteration, and the IRF may be increased for HB SNF, both of which may affect environmental systems associated with SNF long-term storage and disposal. The oxidative matrix dissolution may form various complex uranyl-based phases, including a rich variety of oxides, silicates, carbonates and other secondary minerals in varied geological environments (e.g., studtite, metastudtite, amorphous uranyl peroxide, uranium trioxide, triuranium octoxide, schoepite, dehydrated schoepite, metaschoepite, becquerelite, soddyite, rutherfordine,...). These uranyl phases generally have higher mobility UO 2 +2 species than less soluble U 4+ phases. However, limited information on the thermodynamic properties and formation kinetics of these uranyl-bearing phases is available to predict explicitly paragenesis under the conditions relevant to long-term storage or disposal. The proposed project draws on complementary expertise and research backgrounds from the team members: (i) to apply a combined ab initio modeling (UNLV/UTEP and SNL) and experimental (UNLV) strategy investigating the high-temperature TMC mechanisms of alteration of SNF under α-radiolysis conditions; (ii) to investigate the mechanistic of phase transformations in UNF degradation products under various conditions expected in long-term storage systems (e.g. (UO 2 )O 2 (H 2 O) 4 → (UO 2 )O 2 (H 2 O) 2 → U 2 O 7 → UO 3 → U 3 O 8 ); (iii) to determine high-accuracy TMC parameters for complex uranyl-based phases formed in storage or geological disposal environments (e.g. UO 3 (H 2 O) 2 , Ca[(UO 2 ) 6 O 4 (OH) 8 ] 8 H 2 O, (UO 2 ) 2 (SiO 4 ) 3 2H 2 O,…). The unforeseen COVID-19 pandemic led to the laboratory/campus closure since March 2020, that resulted in a significant delay in reaching milestones in a satisfactory manner, due to (i) the statewide recommendation from stop-working to later limited work in the lab and work-from-home (WFH), (ii) no in-person interactions, and (iii) a hiring freeze at UNLV. Therefore, a no cost extension (10/01/2021- 9/30/2022) was requested to help make up the time we lost during the global pandemic in 2020-2021, leading to paradigm shifts in the focus of the project in the following three main tasks: Task 1 (Computational), Task 2 (Experimental), and Task 3 (Final report, due on 12/29/2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗