Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance of Convection-Permitting and Convection-Parameterized Models in Reproducing the Extreme Precipitation Intensity Relationship with Surface Conditions

Here, this study investigates the warm-season extreme precipitation–temperature scaling relationship in CONUS404, a convection-permitting (4 km) Weather Research and Forecasting (WRF) Model simulation over the conterminous United States for the past four decades, and compares it with the WRF-Thermodynamic Global Warming (WRF-TGW) historical simulation at a coarser resolution (12 km) using parameterized convection. We also analyze the NCEP stage IV and NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement (IMERG) datasets as observational benchmarks. We examine how extreme precipitation intensity (EPI) varies with temperature and saturation deficit over representative regions based on hourly data. The stage IV and IMERG data show a similar pattern of EPI variation with temperature and saturation deficit, except that the EPI peak is lower in IMERG than in stage IV. Under dry and hot conditions, EPI decreases too rapidly with elevated saturation deficit in both CONUS404 and WRF-TGW compared to observations, but the performance of CONUS404 is superior to WRF-TGW. When the near-surface atmosphere is saturated or close to saturated, both CONUS404 and WRF-TGW produce higher peak values of EPI relative to the observational references; IMERG exhibits scaling rates close to the Clausius–Clapeyron (C–C) relationship, while CONUS404, WRF-TGW, and stage IV all demonstrate super-C–C scaling behaviors. Despite marked warming over the past four decades, in both CONUS404 and WRF-TGW, the scaling relationship between EPI and temperature in a saturated atmosphere remains stable and robust. This indicates a strong potential for the EPI–temperature scaling rate under saturation to be used as an emergent constraint in reducing uncertainties of future extreme precipitation projection.

Atmosphere↗

Soil Water Content (m3 m-3) from Australia, May 2014 - March 2017

Hourly data processed to monthly. Data collected from Cosmic Neutron Probes at variable depth averaging 28 cm that was interpolated to near-surface (0-10 cm). Site located at latitude -17.12 deg N, longitude 145.63 deg E. Data was downloaded from COSMOS data portal and is publicly available. Data from this site is referenced as Australia (1) in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Content (m3 m-3) from Australia, June 2011 - December 2016

Hourly data processed to monthly. Data collected from Cosmic Neutron Probes at variable depth averaging 38 cm that was interpolated to near-surface (0-10 cm). Site located at latitude -14.16 deg N, longitude 131.39 deg E. Data was downloaded from the The COsmic-ray Soil Moisture Observing System (COSMOS) soil moisture data network and is publicly available. Data from this site located at, referenced as Australia (2) in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Content (m3 m-3) from Australia, November 2007 - May 2009

Hourly data processed to monthly. Data collected from Eddy Covariance Flux Tower at near-surface (0-10 cm). Site located at latitude -13.08 deg N, longitude 131.12 deg E. Data was downloaded from the FluxNet soil moisture data network and is publicly available. Data from this site located at, referenced as Australia (3) in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Content (m3 m-3) located in Santarem, Brazil K67, July 2000 - February 2004

Hourly data processed to monthly. Data collected from Eddy Covariance Flux Tower at the near-surface (0-10 cm). Site located at a latitude -3.02 deg N, longitude -54.97 deg E. Data was downloaded from the FluxNet soil moisture data network and is publicly available. Data from this site is referenced as Brazil (3) in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Content (m3 m-3) from Australia, August 2001 - December 2014

Hourly data processed to monthly. Data collected from Eddy Covariance Flux Tower at near-surface (0-10 cm). Site located at latitude -12.49 deg N, longitude 131.15 deg E. Data was downloaded from the FluxNet soil moisture data network and is publicly available. Data from this site is referenced as Australia (4) in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Content (m3 m-3), October 2011 - May 2017

Hourly data processed to monthly. Data collected from Cosmic Neutron Probes at variable depth averaging 15 cm that was interpolated to near-surface (0-10 cm). Site located at latitude 0.28 deg N, longitude 36.87 deg E. Data was downloaded from the The COsmic-ray Soil Moisture Observing System (COSMOS) soil moisture data network and is publicly available. Data was made available by the COsmic-ray Soil Moisture Observing SysteM (COSMOS). Data from this site is referenced as Kenya in Table 1 and Figure 4 of Solander et al., 2020, The pan-tropical soil moisture response to El Nino, Hydrol. Earth Syst. Sci., in press.

54 ENVIRONMENTAL SCIENCES↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

A Comparison of Machine Learning Methods to Forecast Tropospheric Ozone Levels in Delhi

Ground-level ozone is a pollutant that is harmful to urban populations, particularly in developing countries where it is present in significant quantities. It greatly increases the risk of heart and lung diseases and harms agricultural crops. This study hypothesized that, as a secondary pollutant, ground-level ozone is amenable to 24 h forecasting based on measurements of weather conditions and primary pollutants such as nitrogen oxides and volatile organic compounds. We developed software to analyze hourly records of 12 air pollutants and 5 weather variables over the course of one year in Delhi, India. To determine the best predictive model, eight machine learning algorithms were tuned, trained, tested, and compared using cross-validation with hourly data for a full year. The algorithms, ranked by R2 values, were XGBoost (0.61), Random Forest (0.61), K-Nearest Neighbor Regression (0.55), Support Vector Regression (0.48), Decision Trees (0.43), AdaBoost (0.39), and linear regression (0.39). When trained by separate seasons across five years, the predictive capabilities of all models increased, with a maximum R 2 of 0.75 during winter. Bidirectional Long Short-Term Memory was the least accurate model for annual training, but had some of the best predictions for seasonal training. Out of five air quality index categories, the XGBoost model was able to predict the correct category 24 h in advance 90% of the time when trained with full-year data. Separated by season, winter is considerably more predictable (97.3%), followed by post-monsoon (92.8%), monsoon (90.3%), and summer (88.9%). These results show the importance of training machine learning methods with season-specific data sets and comparing a large number of methods for specific applications.

54 ENVIRONMENTAL SCIENCES↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

NEW MATRIX COEFFICIENTS FOR THE LOBE POWER CALCULATION AND INDICATION SYSTEM IN THE ADVANCED TEST REACTOR

Theoretical coefficients are tuned for use in the Advanced Test Reactor (ATR) Lobe Power Calculation and Indication System (LPCIS). The LPCIS indicates localized fission powers in the ATR, used primarily by operators to provide irradiation of various experiments at requested power levels. The LPCIS solves an overdetermined matrix, such that the best-fit solution can be obtained from at least five of up to eleven independent indications selected for input. Hourly data logs are reviewed for three and one-half years (from November 2013 through June 2017) of ATR operation to compare localized powers indicated by LPCIS with powers indicated by an independent indication, the Water Power Calculator (WPC). WPC indications are used for the calibration of LPCIS because of assumed high reliability and theoretical simplicity. WPC is also used for automatic core protective functions, which LPCIS is not. As the WPC provides power only for four quadrants and the LPCIS indicates power in five lobes, a calculated metric is required to compare the two indications. The metric chosen for the current work has been in use for decades at ATR as a metric of LPCIS health. The proposed new coefficients better fit theory of physical phenomena involved and also provide a 40% improvement in the calculated fit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparative Evaluation of Additive Manufactured Stainless Steel Test Pieces

Stainless steel is used for variety of applications with different grades, alloys, filaments and powders. Additive manufacturing (AM) enables unique design features and refined microstructures. Performance testing on AM parts are needed as input to modeling and accelerated qualification processes. The objective of this work is to determine the effect of surface roughness on corrosion rate for from different manufacturers Preliminary evaluation shows that the 500-hour data set was scattered, and trend analysis are complex, while the 1000h and 1500h test results evaluation show more distinct trends.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Incorporating Combined Heat and Power Modeling into the REopt Lite Web Tool

The National Renewable Energy Laboratory (NREL) is working with project partners to extend the U.S. Department of Energy’s (DOE’s) REopt Lite tool to include combined heat and power (CHP) modeling capabilities. REopt Lite currently provides technoeconomic optimization and resilience analysis for grid-connected solar photovoltaics, (PV), wind, and battery storage at a site. The tool analyzes hourly data across the project lifecycle and evaluates the trade-off between capital costs, operating costs, and savings to find the most cost-effective mix of technologies.

Combined Heat and Power, CHP, Modeling, Tool, Fact↗

Detailed Study of Emergency Diesel Generator Performance Using EPIX/RADS Database

A recent report was published by the U.S. Nuclear Regulatory Commission – Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants, NUREG/CR-6928. That report characterized industry performance (generally covering 1998 – 2002) for 51 component types found in commercial nuclear power plants. For example, for emergency diesel generators, three failure modes were identified: fail to start and reach rated speed and voltage, fail to load and run for one hour, and fail to run beyond one hour. Data from the U.S. industry contained in the Equipment Performance and Information Exchange (EPIX) database maintained by The Institute for Nuclear Power Operations were used to evaluate the failure probabilities and rates for these failure modes, covering 1998 – 2002. The software package Reliability and Availability Database System (RADS) was used to search and process the EPIX data. In addition, train test and maintenance unavailability was characterized for 34 train types. As a follow-on effort to this report, several components will be analyzed in more detail each year. These detailed studies include more recent data and analyze various subcategories such as manufacturer, system, size and type (as applicable). In addition, engineering insights such as piece part contribution to each failure mode and failure cause will be determined. This paper summarizes the preliminary results for emergency diesel generators. EPIX data coverage was expanded to include 1998 – 2007 and reliability results were compared with unplanned demand performance (bus under voltage events requiring the emergency diesel generator to start, load and run) over the same period. In addition, performance by manufacturer was evaluated. Finally, piece part contributions and failure causes were determined for each failure mode.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamically Downscaled Hourly Future Weather Data with 12-km Resolution Covering Most of North America

This is an hourly future weather dataset for energy modeling applications. The dataset is primarily based on the output of a regional climate model (RCM), i.e., the Weather Research and Forecasting (WRF) model version 3.3.1. The WRF simulations are driven by the output of a general circulation model (GCM), i.e., the Community Climate System Model version 4 (CCSM4). This dataset is in the EPW format, which can be read or translated by more than 25 building energy modeling programs (e.g., EnergyPlus, ESP-r, and IESVE), energy system modeling programs (e.g., System Advisor Model (SAM)), indoor air quality analysis programs (e.g., CONTAM), and hygrothermal analysis programs (e.g., WUFI). It contains 13 weather variables, which are the Dry-Bulb Temperature, Dew Point Temperature, Relative Humidity, Atmospheric Pressure, Horizontal Infrared Radiation Intensity from Sky, Global Horizontal Irradiation, Direct Normal Irradiation, Diffuse Horizontal Irradiation, Wind Speed, Wind Direction, Sky Cover, Albedo, and Liquid Precipitation Depth. The weather data is created for two emissions scenarios: RCP4.5 and RCP8.5 and spans two 10-year time slices in the future: 2045 - 2054 and 2085 - 2094. It offers a spatial resolution of 12 km by 12 km with extensive coverage across most of North America. Due to the enormous size of the entire dataset, in the first stage of its distribution, we provide 20 years of future weather data for the centroid of each Public Use Microdata Area (PUMA), excluding Hawaii. PUMAs are non-overlapping, statistical geographic areas that partition each state or equivalent entity into geographic areas containing no fewer than 100,000 people each. The 2,378 PUMAs as a whole cover the entirety of the U.S. The weather data can be utilized alongside the large-scale energy analysis tools, ResStock and ComStock, developed by National Renewable Energy Laboratory, whose smallest resolution is at the PUMA scale. The data for RCP4.5 is still being processed and will be published soon.

Array↗

An improved method for direct incident solar radiation calculation from hourly solar insolation data in building energy simulation

Solar radiation considerably influences the energy consumption of buildings and the power production of building integrated photovoltaic (BIPV) systems. Hourly solar insolation (Wh/m 2 ), represented as the amount of solar irradiance collected on the ground during a 1-h period, is the most common solar radiation data available and widely used in weather files applied in building energy modeling programs (BEMPs). Because the solar beam and position vary over time, the use of hourly insolation data as the input might result in errors in the estimation of the direct incident solar radiation on a particular surface. In this study, methods used in BEMPs for direct incident solar radiation calculations are first analyzed, and an improved method adopting a new algorithm for estimating the solar irradiance is proposed. Furthermore, the algorithm assumes that the solar irradiance changes linearly within a 1-h period and can be estimated based on the solar irradiance at the half clock and slope. The collected direct normal solar irradiance data of 2016 from eight solar radiation stations in China were used to demonstrate the proposed method and evaluate its performance by comparing the results with those from three conventional methods used in BEMPs along with the ground truth measurements. In addition, in this study, factors affecting the accuracy of the calculation results are explored. The results of the estimated direct incident solar radiation show that the proposed method achieves the best accuracy, followed by the methods used in DOE-2, EnergyPlus, and DeST. The proposed method guarantees that the hourly direct solar insolation will remain the same and reflects the variation in the direct solar irradiance across a 1-h time frame. The proposed method can be adopted in BEMPs to improve the accuracy of the solar radiation calculation, thereby improving the accuracy of the simulated building performance and the BIPV production.

14 SOLAR ENERGY↗

Reliability analysis of solar photovoltaic system using hourly mean solar radiation data

This paper presents the hourly mean solar radiation and standard deviation as inputs to simulate the solar radiation over a year. Monte Carlo simulation (MCS) technique is applied and MATLAB program is developed for reliability analysis of small isolated power system using solar photovoltaic (SPV). This paper is distributed in two parts. Firstly various solar radiation prediction methods along with hourly mean solar radiation (HMSR) method are compared. The comparison is carried on the basis of predicted electrical power generation with actual power generated by SPV system. Estimation of solar photovoltaic power using HMSR method is close to the actual power generated by SPV system. The deviation in monsoon months is due to the cloud cover. In later part of the paper various reliability indices are obtained by HMSR method using MCS technique. Load model used is IEEE-RTS. Reliability indices, additional load hours (ALH) and additional power (AP) reduces exponentially with increase in load indicates that a SPV source will offset maximum fuel when all of its generated energy is utilized. Fuel saving calculation is also investigated. Case studies are presented for Sagardeep Island in West Bengal state of India. (author)

14 SOLAR ENERGY↗