DOE-ID-INL-20-219 R1
DOE-ID-INL-20-219 R1 for INL-21-219 R1.
RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)
We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.
Complementary sub-micron scanning x-ray Bragg diffraction and fluorescence mapping at 5-ID, NSLS-II
Explore the source record for details and available documents.
Magnetotelluric Data from Mountain Home, ID
This dataset includes magnetotelluric transfer functions in the form of EDI files for 16 stations collected by the USGS and 40 stations collected by Quantec Geoscience for Lawerence Berkeley National Lab around the Mountain Home area in Idaho. A 3D electrical resistivity model is included that images resistive and conductive bodies in the subsurface that maybe important for geothermal characterization. The model was created using ModEM using the high performance computer Yeti at the USGS.
National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)
We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121
Site 300 (Facility ID N-472) Toxic Emissions Inventory Plan
The Air Toxics "Hot Spots" Information and Assessment Act (AB 2588 or the “Act”) was enacted in September 1987. Under the Act, stationary sources are required to report the types and quantities of certain toxic substances their facilities routinely release into the air. AB 2588 is designed to provide information to state and local agencies and to the general public on the extent of airborne emissions from stationary sources and the potential public health impacts of those emissions. The San Joaquin Valley Air Pollution Control District (the District) is mandated by the State to implement AB 2588. On March 6, 2015, The State Office of Environmental Health Hazard Assessment (OEHHA) adopted changes to the Air Toxics Hot Spots Program Guidance Manual for the Preparation of Health Risk Assessments. These revisions were designed to incorporate three technical support documents and to provide enhanced protection of children as required under state law (SB 25, Escutia, 1999). Due to these recent changes, and the corresponding potential increases in calculated health risk, the District notified LAWRENCE LIVERMORE NATL SECURITY, LLC that we must be re-evaluated under AB 2588. Pursuant to the Air Toxics "Hot Spots" Information and Assessment Act of 1987, we have prepared a comprehensive, site-specific Toxics Emissions Inventory Plan. The plan specifies in detail how LAWRENCE LIVERMORE NATL SECURITY, LLC will inventory our facility's emissions of all toxic substances on the list of substances subject to the Act. The plan provides a comprehensive and detailed description of the methods that will be used to quantify air releases or potential air releases of listed substances from all points of release. The plan also includes quantification methods which result in accurate and comprehensive characterization of releases and comply with all applicable requirements of the “Hot Spots” regulation.
Lawrence Livermore National Security, LLC Site 300 Facility ID N-472 Toxics Emissions Inventory Plan for AB 2588 California Air Toxics "Hot Spots" Information and Assessment Act of 1987
The Air Toxics "Hot Spots" Information and Assessment Act (AB 2588 or the “Act”) was enacted in September 1987. Under the Act, stationary sources are required to report the types and quantities of certain toxic substances their facilities routinely release into the air. AB 2588 is designed to provide information to state and local agencies and to the general public on the extent of airborne emissions from stationary sources and the potential public health impacts of those emissions. The San Joaquin Valley Air Pollution Control District (the District) is mandated by the State to implement AB 2588.
Attenuator, PC-2.92mm, Fixed (Proficiency Test Report; PT ID Number 6679665)
The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 12/28/2021, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.
ID HS Code - ECCN Correlation Introduction [Slides]
Harmonized System (HS) Codes, Export Control Classification Numbers (ECCN), and Control Lists are described.
Designing a Comprehensive IDS Strategy for a Zero Trust Architecture Environment
Zero Trust Architecture or ZTA is a cybersecurity model for enterprises to structure their networked resources around to maintain total security externally and internally. In a Zero Trust environment, no part of the network is considered "trustworthy" and thus should be scrutinized and monitored extensively as is done in traditional "Trust But Verify" schemes at the network's perimeter. In this way, Zero Trust Architecture is a superior model for securing access to networked resources at the enterprise level. Fermilab, in pursuit of a better security posture, has decided to embrace this model of architecture for its network. Attaining this goal requires tremendous infrastructural, policy, and procedural adjustments that will affect all the lab's personnel and resources.
Machine Learning-Based Intrusion Detection Systems (IDS) for Wind Networks
Explore the source record for details and available documents.
Routine & Nonredundant Steel Tension Member (NSTM) Inspection Report (Final): Property ID No. 43-0434 - Los Alamos Canyon Bridge
This report covers the inspection findings for the Routine and Nonredundant Steel Tension Member (NSTM) Inspection of the Los Alamos Canyon Bridge over Omega Rd conducted on June 7-9, 2024. The inspections were completed according to the standards referenced in DOE O 437.1 Bridge and Tunnel Management including the National Bridge Inspection Standards (23 CFR Part 650, dated 12/14/2004) and other Federal Highway Administration (FHWA), New Mexico Department of Transportation (NMDOT), and American Association of State Highway and Transportation Officials (AASHTO) codes and standards.