Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High Contrast Imaging with the JWST NIRCAM Coronagraph

Relative to ground-based telescopes, the James Webb Space Telescope (JWST) will have a substantial sensitivity advantage in the 2.2-5pm wavelength range where brown dwarfs and hot Jupiters are thought to have significant brightness enhancements. To facilitate high contrast imaging within this band, the Near-Infrared Camera (NIRCAM) will employ a Lyot coronagraph with an array of band-limited image-plane occulting spots. In this paper, we provide the science motivation for high contrast imaging with NIRCAM, comparing its expected performance to that of the Keck, Gemini and 30 m (TMT) telescopes equipped with Adaptive Optics systems of different capabilities. We then describe our design for the NIRCAM coronagraph that enables imaging over the entire sensitivity range of the instrument while providing significant operational flexibility. We describe the various design tradeoffs that were made in consideration of alignment and aberration sensitivities and present contrast performance in the presence of JWST's expected optical aberrations. Finally we show an example of a that can provide 10-5 companion sensitivity at sub-arcsecond separations.

coronagraph↗

Quantitative In Situ Studies of Dynamic Fracture in Brittle Solids Using Dynamic X-ray Phase Contrast Imaging

Here, we demonstrate the use of X-ray phase contrast imaging with sub-microsecond temporal resolution to obtain quantitative visualization of dynamic fracture processes in brittle solids. We examine an amorphous solid (fused silica), a ceramic single crystal (single-crystal quartz), and a polycrystalline ceramic (boron carbide), in the form of single-edge notched specimens loaded using a three-point apparatus at nominal strain rates up to ~800 s -1 . We observe that the crack tip speed for boron carbide is relatively independent of mode I stress intensity factor rate ($\dot{K}$ I ) for these rates of loading, while that of fused silica and single-crystal quartz increases with $\dot{K}$ I . Further, for the amorphous and single crystal cases, we observe the development of a crack tip instability in the form of crack branching as the crack tip speed approaches 45% of the Rayleigh wave speed. This suggests that strain-rate-dependent mechanisms contribute to crack branching. Such mechanisms may, in turn, affect the macroscopic fracture properties of these materials.

36 MATERIALS SCIENCE↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Efficient phase contrast imaging in STEM using a pixelated detector. Part 1: Experimental demonstration at atomic resolution

In this paper, we demonstrate a method to achieve high efficiency phase contrast imaging in aberration corrected scanning transmission electron microscopy (STEM) with a pixelated detector. The pixelated detector is used to record the Ronchigram as a function of probe position which is then analyzed with ptychography. Ptychography has previously been used to provide super-resolution beyond the diffraction limit of the optics, alongside numerically correcting for spherical aberration. Here we rely on a hardware aberration corrector to eliminate aberrations, but use the pixelated detector data set to utilize the largest possible volume of Fourier space to create high efficiency phase contrast images. The use of ptychography to diagnose the effects of chromatic aberration is also demonstrated. In conclusion, the four dimensional dataset is used to compare different bright field detector configurations from the same scan for a sample of bilayer graphene. Our method of high efficiency ptychography produces the clearest images, while annular bright field produces almost no contrast for an in-focus aberration-corrected probe.

36 MATERIALS SCIENCE↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

Observation of Crack Propagation in Glass Using X-ray Phase Contrast Imaging

High-speed X-ray phase contrast imaging synchronized with a Kolsky bar apparatus was utilized to investigate the cracking behavior of a borosilicate glass, a soda lime glass, and a glass ceramic in front of a cylindrical projectile with an impact velocity of 5ms(-1). For each material, three different surface conditions were prepared for the impacted edge of the specimen. Angular cracking was observed in front of the projectile for borosilicate glass. For soda lime glass, straight cracking was observed. For glass ceramic, curved cracking was observed in front of the projectile. Cracking behavior was observed to be independent of the surface condition on the impacted edge.

Parab, Niranjan D.↗

Characterization of Low Mass Deformable Mirrors and ASIC Driver for High-Contrast Imaging

The development of compact, high performance Deformable Mirrors (DMs) is one of the most important techno-logical challenges for high-contrast imaging on space missions. Microscale Inc. has fabricated and characterized piezoelectric stack actuator deformable mirrors (PZT-DMs) and Application-Speci c Integrated Circuit (ASIC) drivers for direct integration. The DM-ASIC system is designed to eliminate almost all cables, enabling a very compact optical system with low mass and low power consumption. We report on the optical tests used to evaluate the performance of the DM and ASIC units. We also compare the results to the requirements for space-based high-contrast imaging of exoplanets. .

Prada, Camilo Mejia↗

X-ray elastography: Modification of x-ray phase contrast images using ultrasonic radiation pressure

The high resolution characteristic of in-line x-ray phase contrast imaging can be used in conjunction with directed ultrasound to detect small displacements in soft tissue generated by differential acoustic radiation pressure. The imaging method is based on subtraction of two x-ray images, the first image taken with, and the second taken without the presence of ultrasound. The subtraction enhances phase contrast features and, to a large extent, removes absorption contrast so that differential movement of tissues with different acoustic impedances or relative ultrasonic absorption is highlighted in the image. Interfacial features of objects with differing densities are delineated in the image as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. Experiments with ex vivo murine tumors and human tumor phantoms point out a diagnostic capability of the method for identifying tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The safety of magnetic resonance imaging contrast agents

Gadolinium-based contrast agents are increasingly used in clinical practice. While these pharmaceuticals are verified causal agents in nephrogenic systemic fibrosis, there is a growing body of literature supporting their role as causal agents in symptoms associated with gadolinium exposure after intravenous use and encephalopathy following intrathecal administration. Gadolinium-based contrast agents are multidentate organic ligands that strongly bind the metal ion to reduce the toxicity of the metal. The notion that cationic gadolinium dissociates from these chelates and causes the disease is prevalent among patients and providers. We hypothesize that non-ligand-bound (soluble) gadolinium will be exceedingly low in patients. Soluble, ionic gadolinium is not likely to be the initial step in mediating any disease. The Kidney Institute of New Mexico was the first to identify gadolinium-rich nanoparticles in skin and kidney tissues from magnetic resonance imaging contrast agents in rodents. In 2023, they found similar nanoparticles in the kidney cells of humans with normal renal function, likely from contrast agents. We suspect these nanoparticles are the mediators of chronic toxicity from magnetic resonance imaging contrast agents. This article explores associations between gadolinium contrast and adverse health outcomes supported by clinical reports and rodent models.

59 BASIC BIOLOGICAL SCIENCES↗

Image contrast reversals in contact resonance atomic force microscopy

Multiple image contrast inversions are observed along with the increase of modulation frequency for contact resonance atomic force microscopy (CR-AFM) imaging of a highly oriented pyrolytic graphite (HOPG) specimen. Analysis of the contact vibrational spectra indicates that the inversions can be attributed to structure-induced variations of tip-sample contact mechanics. Contact stiffness and damping at HOPG step edges exhibit significant increases relative to those in the flat regions. For quantitative evaluation of mechanical properties in CR-AFM, coupling effects of the surface geometry must be considered.

36 MATERIALS SCIENCE↗

NEW TECHNIQUES FOR HIGH-CONTRAST IMAGING WITH ADI: THE ACORNS-ADI SEEDS DATA REDUCTION PIPELINE

We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the SEEDS survey. We implement several new algorithms, including a method to register saturated images, a trimmed mean for combining an image sequence that reduces noise by up to {approx}20%, and a robust and computationally fast method to compute the sensitivity of a high-contrast observation everywhere on the field of view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is written in python. It is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI requires minimal modification to reduce data from instruments other than HiCIAO. It is freely available for download at www.github.com/t-brandt/acorns-adi under a Berkeley Software Distribution (BSD) license.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Demonstrations of High-contrast Imaging for Space Coronagraphy

This slide presentation reviews the use of the High Contrast Imaging Testbed (HCIT) in the design and improvement of space coronagraphs. The objectives of the work are to: (1) Advance the technology readiness of space coronagraph hardware, techniques, algorithms, and predictive models; (2) Provide proof-of-concept demonstrations of coronagraph techniques; and (3) Support collaborations across the exoplanet community in pursuit of the optimal space coronagraph architecture.

High Contrast Imaging Testbed (HCIT)↗

High-Contrast Imaging of Epsilon Eridani with Ground-Based Instruments

Epsilon Eridani is one of the nearest solar-type stars. Its proximity and relatively young age allow high-contrast imaging observations to achieve sensitivities to planets at narrow separations down to an inner radius of approximately 5 AU. Previous observational studies of the system report a dust disk with asymmetric morphology as well as a giant planet with large orbital eccentricity, which may require another massive companion to induce the peculiar morphology and to enhance the large orbital eccentricity. In this paper, we report results from deep high-contrast imaging observations to detect the previously reported planet and search for other unseen less massive companions with Subaru/HiCIAO, Gemini-South/NICI, and VLT/NACO. No positive detection was made, but high-contrast measurements with the CH4S narrow-band filter of HiCIAO achieved sensitivities at 14.7 mag differential magnitude level, at an angular separation of 1.0''. In terms of planetary mass, as determined by cooling evolutionary models, the highest sensitivities were achieved by the Lp broad-band filter of NACO, resulting in sensitivities corresponding to 1.8, 2.8, and 4.5 M(sub jup) at the projected separation of 3 AU, if 200, 400, and 800 Myr is assumed for the age of the system, respectively. We also discuss origins of the dust disk from the detection sensitivity in the planetary mass and find that a less massive eccentric planet is preferred for disk stirring, which is consistent with the orbital parameters of epsilon Eri b claimed from the previous long-term radial velocity monitoring.

Epsilon Eridani↗

New Techniques for High-Contrast Imaging with ADI: The ACORNS-ADI SEEDS Data Reduction Pipeline

We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the Strategic Exploration of Exoplanets and Disks (SEEDS) survey. We implement seyeral new algorithms, includbg a method to centroid saturated images, a trimmed mean for combining an image sequence that reduces noise by up to approx 20%, and a robust and computationally fast method to compute the sensitivitv of a high-contrast obsen-ation everywhere on the field-of-view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI is freely available for download at www.github.com/t-brandt/acorns_-adi under a BSD license

Brandt, Timothy D.↗

From Relativistic Electrons to X-ray Phase Contrast Imaging

We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphor’s 80-μm value. Potential fiber-optic plate depth-of-focus aspects and 33-μm diameter carbon fiber imaging are also addressed.

43 PARTICLE ACCELERATORS↗

Fundamental limitations of high contrast imaging set by small sample statistics

In this paper, we review the impact of small sample statistics on detection thresholds and corresponding confidence levels (CLs) in high-contrast imaging at small angles. When looking close to the star, the number of resolution elements decreases rapidly toward small angles. This reduction of the number of degrees of freedom dramatically affects CLs and false alarm probabilities. Naively using the same ideal hypothesis and methods as for larger separations, which are well understood and commonly assume Gaussian noise, can yield up to one order of magnitude error in contrast estimations at fixed CL. The statistical penalty exponentially increases toward very small inner working angles. Even at 5-10 resolution elements from the star, false alarm probabilities can be significantly higher than expected. Here we present a rigorous statistical analysis that ensures robustness of the CL, but also imposes a substantial limitation on corresponding achievable detection limits (thus contrast) at small angles. This unavoidable fundamental statistical effect has a significant impact on current coronagraphic and future high-contrast imagers. Finally, the paper concludes with practical recommendations to account for small number statistics when computing the sensitivity to companions at small angles and when exploiting the results of direct imaging planet surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating the X-Ray Image Contrast to Set-Up Techniques with Desired Flaw Detectability

The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is being developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing X-ray detector resolution for crack detection. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

Koshti, Ajay M.↗

ESTIMATES OF THE PLANET YIELD FROM GROUND-BASED HIGH-CONTRAST IMAGING OBSERVATIONS AS A FUNCTION OF STELLAR MASS

We use Monte Carlo simulations to estimate the number of extrasolar planets that are directly detectable in the solar neighborhood using current and forthcoming high-contrast imaging instruments. Our calculations take into consideration the important factors that govern the likelihood for imaging a planet, including the statistical properties of stars in the solar neighborhood, correlations between star and planet properties, observational effects, and selection criteria. We consider several different ground-based surveys, both biased and unbiased, and express the resulting planet yields as a function of stellar mass. Selecting targets based on their youth and visual brightness, we find that strong correlations between star mass and planet properties are required to reproduce high-contrast imaging results to date (i.e., HR 8799, {beta} Pic). Using the most recent empirical findings for the occurrence rate of gas-giant planets from radial velocity (RV) surveys, our simulations indicate that naive extrapolation of the Doppler planet population to semimajor axes accessible to high-contrast instruments provides an excellent agreement between simulations and observations using present-day contrast levels. In addition to being intrinsically young and sufficiently bright to serve as their own beacon for adaptive optics correction, A-stars have a high planet occurrence rate and propensity to form massive planets in wide orbits, making them ideal targets. The same effects responsible for creating a multitude of detectable planets around massive stars conspire to reduce the number orbiting low-mass stars. However, in the case of a young stellar cluster, where targets are approximately the same age and situated at roughly the same distance, MK-stars can easily dominate the number of detections because of an observational bias related to small number statistics. The degree to which low-mass stars produce the most planet detections in this special case depends upon whether multiple formation mechanisms are at work. Upon relaxing our assumption that planets in ultra-wide (a > 100 AU) orbits resemble the RV sample, our simulations suggest that the companions found orbiting late-type stars (AB Pic, 1RXSJ1609, GSC 06214, etc.) are consistent with a formation channel distinct from that of RV planets. These calculations explain why planets have thus far been imaged preferentially around A-stars and K-, M-stars, but no spectral types in between, despite concerted efforts targeting F-, G-stars.

79 ASTRONOMY AND ASTROPHYSICS↗