Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMU”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Trajectory Reconstruction of the Low-Earth Orbit Flight Test of an Inflatable Decelerator

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) project conducted a flight test of a 6m inflatable aeroshell. The LOFTID test article was a secondary payload on an Atlas V launcher that carried the Joint Polar Satellite System-2 (JPSS-2) as its primary payload. The vehicle launched on November 10th, 2022. After reaching orbit, the LOFTID test article inflated the aeroshell, separated from the upper stage on an entry trajectory, and entered the atmosphere to splash down in the Pacific Ocean under parachutes. The test concept of operations is shown in Figure 1. The test article was instrumented with a variety of sensors to be used for post-flight evaluation of vehicle performance. Data from one of the key sensors for trajectory reconstruction, the Inertial Measurement Unit (IMU), was not captured in the data recorder due to a malfunction. Data from the nose cone mounted Flush Air Data Sensing (FADS) system were successfully acquired. The layout of the FADS sensors and the measured pressures during atmospheric entry are shown in Figure 2. The FADS data were combined with a Newtonian flow pressure model [1, 2] to produce estimates of the atmospheric relative trajectory. A Mach number anchoring technique given in [2] was used to stabilize estimates in high speed flight conditions. Since no IMU data were available, a trajectory simulation was used to provide the Mach number time history. The resulting estimates of the atmospheric-relative trajectory are shown in Figures 3. Given the loss of the IMU data, alternate methods for trajectory reconstruction are being explored. One approach under investigation is the use of the on-board video recorder data to be analyzed to reconstruct attitude motion. This approach is currently under investigation and will be reported on in the final paper. The Newtonian flow pressure model for the FADS analysis will also be updated with a CFD-based pressure model.

Christopher D Karlgaard↗

Trajectory Reconstruction of the Low-Earth Orbit Flight Test of an Inflatable Decelerator

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) project conducted a flight test of a 6m inflatable aeroshell. The LOFTID test article was a secondary payload on an Atlas V launcher that carried the Joint Polar Satellite System-2 (JPSS-2) as its primary payload. The vehicle launched on November 10th, 2022. After reaching orbit, the LOFTID test article inflated the aeroshell, separated from the upper stage on an entry trajectory, and entered the atmosphere to splash down in the Pacific Ocean under parachutes. The test concept of operations is shown in Figure 1. The test article was instrumented with a variety of sensors to be used for post-flight evaluation of vehicle performance. Data from one of the key sensors for trajectory reconstruction, the Inertial Measurement Unit (IMU), was not captured in the data recorder due to a malfunction. Data from the nose cone mounted Flush Air Data Sensing (FADS) system were successfully acquired. The layout of the FADS sensors and the measured pressures during atmospheric entry are shown in Figure 2. The FADS data were combined with a Newtonian flow pressure model [1, 2] to produce estimates of the atmospheric relative trajectory. A Mach number anchoring technique given in [2] was used to stabilize estimates in high speed flight conditions. Since no IMU data were available, a trajectory simulation was used to provide the Mach number time history. The resulting estimates of the atmospheric-relative trajectory are shown in Figures 3. Given the loss of the IMU data, alternate methods for trajectory reconstruction are being explored. One approach under investigation is the use of the on-board video recorder data to be analyzed to reconstruct attitude motion. This approach is currently under investigation and will be reported on in the final paper. The Newtonian flow pressure model for the FADS analysis will also be updated with a CFD-based pressure model.

Christopher D. Karlgaard↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Admiralty Inlet Hub-Height Turbulence Measurements from June 2012

This data is from measurements at Admiralty Head, in Admiralty Inlet. The measurements were made using an IMU equipped ADV mounted on a mooring, the 'Tidal Turbulence Mooring' or 'TTM'. The inertial measurements from the IMU allows for removal of mooring motion in post processing. The mooring motion has been removed from the stream-wise and vertical velocity signals (u, w). The lateral (v) velocity may have some 'persistent motion contamination' due to mooring sway. The ADV was positioned 11m above the seafloor in 58m of water at 48.1515N, 122.6858W. Units ------ - Velocity data (_u, urot, uacc) is in m/s. - Acceleration (Accel) data is in m/s^2. - Angular rate (AngRt) data is in rad/s. - The components of all vectors are in 'ENU' orientation. That is, the first index is True East, the second is True North, and the third is Up (vertical). - All other quantities are in the units defined in the Nortek Manual. Motion correction and rotation into the ENU earth reference frame was performed using the Python-based open source DOLfYN library (linked in resources). Details on motion correction can be found there. For additional details on this dataset see the included Marine Energy Technology Symposium paper.

16 TIDAL AND WAVE POWER↗

Hospital Organization and Importance of an Interventional Radiology Inpatient Admitting Service: Italian Single-Center 3-Year Experience

In June 2005 a Complex Operating Unit of Interventional Radiology (COUIR), consisting of an outpatient visit service, an inpatient admitting service with four beds, and a day-hospital service with four beds was installed at our department. Between June 2005 and May 2008, 1772 and 861 well-screened elective patients were admitted to the inpatient ward of the COUIR and to the Internal Medicine Unit (IMU) or Surgery Unit (SU) of our hospital, respectively, and treated with IR procedures. For elective patients admitted to the COUIR's inpatient ward, hospital stays were significantly shorter and differences between reimbursements and costs were significantly higher for almost all IR procedures compared to those for patients admitted to the IMU and SU (Student's t-test for unpaired data, p < 0.05). The results of the 3-year activity show that the activation of a COUIR with an inpatient admitting service, and the better organization of the patient pathway that came with it, evidenced more efficient use of resources, with the possibility for the hospital to save money and obtain positive margins (differences between reimbursements and costs). During 3 years of activity, the inpatient admitting service of our COUIR yielded a positive difference between reimbursements and effective costs of Euro 1,009,095.35. The creation of an inpatient IR service and the admission of well-screened elective patients allowed short hospitalization times, reduction of waiting lists, and a positive economic outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Admiralty Inlet Advanced Turbulence Measurements: June 2014

This data is from measurements at Admiralty Head, in Admiralty Inlet (Puget Sound) in June of 2014. The measurements were made using Inertial Motion Unit (IMU) equipped ADVs mounted on Tidal Turbulence Mooring's (TTMs). The TTM positions the ADV head above the seafloor to make mid-depth turbulence measurements. The inertial measurements from the IMU allows for removal of mooring motion in post processing. The mooring motion has been removed from the stream-wise and vertical velocity signals (u, w). The lateral (v) velocity has some 'persistent motion contamination' due to mooring sway. Each ttm was deployed with two ADVs. The 'top' ADV head was positioned 0.5m above the 'bottom' ADV head. The TTMs were placed in 58m of water. The position of the TTMs were: ttm01 : (48.1525, -122.6867) ttm01b : (48.15256666, -122.68678333) ttm02b : (48.152783333, -122.686316666) Deployments TTM01b and TTM02b occurred simultaneously and were spaced approximately 50m apart in the cross-stream direction. Units ----- - Velocity data (_u, urot, uacc) is in m/s. - Acceleration (Accel) data is in m/s^2. - Angular rate (AngRt) data is in rad/s. - The components of all vectors are in 'ENU' orientation. That is, the first index is True East, the second is True North, and the third is Up (vertical). - All other quantities are in the units defined in the Nortek Manual. Motion correction and rotation into the ENU earth reference frame was performed using the Python-based open source DOLfYN library (http://lkilcher.github.io/dolfyn/). Details on motion correction can be found there. Additional details on TTM measurements at this site can be found in the included Marine Energy Technology Symposium paper.

16 TIDAL AND WAVE POWER↗

Admiralty Inlet Advanced Turbulence Measurements: May 2015

This data is from measurements at Admiralty Head, in Admiralty Inlet (Puget Sound) in May of 2015. The measurements were made using Inertial Motion Unit (IMU) equipped ADVs mounted on a 'StableMoor' (Manufacturer: DeepWater Buoyancy) buoy and a Tidal Turbulence Mooring (TTM). These platforms position ADV heads above the seafloor to make mid-depth turbulence measurements. The inertial measurements from the IMU allows for removal of mooring motion in post processing. The mooring and buoy motion has been removed from the stream-wise and vertical velocity signals (u, w). The lateral (v) velocity has some 'persistent motion contamination' due to mooring sway. The TTM was deployed with one ADV, it's position was: 48 09.145', -122 41.209' The StableMoor was deployed twice, the first time it was deployed in 'wing-mode' with two ADVs ('Port' and 'Star') at: 48 09.166', -122 41.173' The second StableMoor deployment was in 'Nose' mode with one ADV at: 48 09.166', -122 41.174' Units ----- - Velocity data (_u, urot, uacc) is in m/s. - Acceleration (Accel) data is in m/s^2. - Angular rate (AngRt) data is in rad/s. - The components of all vectors are in 'ENU' orientation. That is, the first index is True East, the second is True North, and the third is Up (vertical). - All other quantities are in the units defined in the Nortek Manual. Motion correction and rotation into the ENU earth reference frame was performed using the Python-based open source DOLfYN library (http://lkilcher.github.io/dolfyn/). Details on motion correction can be found there. Additional details on TTM measurements at this site can be found in the included Marine Energy Technology Symposium paper.

16 TIDAL AND WAVE POWER↗

Tidal Energy Resource Characterization, Velocity and Turbulence Measurements, Processed Data, Cook Inlet, AK, 2021

This submission contains processed datasets from a long-term deployment of 3 moorings and a transect survey of the proposed tidal energy site off the East Forelands in Cook Inlet, AK. The long-term mooring datasets were created from 8 instruments mounted on a Terrasond High Energy Oceanographic Mooring (THEOM) bottom lander and two Mid-Water Mooring (MWM) Stablemoor buoys from 1 July 2021 to 31 August 2021 (60 days). The west-most mooring (MWM1) was deployed at 60.720225 N, 151.436196 W in ~50 m of water. The middle mooring (THEOM) was deployed at 60.720703 N, 151.429500 W in ~52 m of water. The east-most buoy (MWM2) was deployed at 60.720081 N, 151.420896 W in ~50 m of water. Each Stablemoor carried three instruments: 1. A Nortek Vector acoustic Doppler velocimeter (ADV) mounted at the Stablemoor's nose. Data were recorded at 8 Hz on a 5 minute duty cycle every 20 minutes. Data was motion-corrected using the internal IMU and external ADCP bottom-track data and then bin-averaged into 4 minute bins and converted to the Principal (streamwise, cross-stream, vertical) coordinate system. (Note: 30 seconds were trimmed from the beginning and end of each 5 minute duty cycle to account for the filter end-effects from turning on and turning off the IMU.) 2. A down-looking Nortek Signature 1000 kHz acoustic Doppler current profiler (ADCP) mounted in the first Stablemoor instrument well. Data were recorded in 2 Hz with 5-beam burst and bottom-track enabled. Processed data has been averaged into 10 minute bins and converted into the Principal coordinate system. 3. An up-looking Nortek Signature 1000 kHz acoustic Doppler current profiler (ADCP) mounted in the second Stablemoor instrument well. Data were recorded at 4 Hz with 5 beam burst enabled. Processed data has been averaged into 10 minute bins and converted into the Principal coordinate system. Note: the down-facing ADCP on MWM1 failed on July 10th, 2021, only recording 9 days of data. Because ADV motion-correction required bottom track, the ADV from MWM1 also only has 9 days processed. Additionally, only 25 days of data were processed from the MWM2 ADV because it appeared to have been impacted by debris on 7/25. Two instruments were mounted on the THEOM (see MHKDR link further below for THEOM raw data): 4. A Nortek Vector acoustic Doppler velocimeter (ADV). Data were recorded at 8 Hz on a 5 minute duty cycle every 20 minutes. Data was bin-averaged into 5 minute bins, and converted to the Principal coordinate system. 5. A Nortek Signature 500 kHz acoustic Doppler current profiler (ADCP). Data were recorded in 4 Hz in the beam coordinate system from all 5 beams. Processed data has been averaged into 10 minutes bins and converted to the Principal coordinate system.

16 TIDAL AND WAVE POWER↗

NA-241_Quarterly Report_SBLibby - 12.31.2017_v2

This is an evaluation of candidate navigation solutions for GPS free inspection tools that can be used in tours of large building interiors. In principle, COTS portable inertial motion unit (IMU) sensors with satisfactory accuracy, SWAP (size, weight, power), low error, and bias drift can provide sufficiently accurate dead reckoning navigation in a large building in the absence of GPS. To explore this assumption, the capabilities of representative IMU navigation sensors to meet these requirements will be evaluated, starting with a market survey, and then carrying out a basic analysis of these sensors using LLNL’s navigation codes.

42 ENGINEERING↗

NA-241-Quarterly Report_SBLibby - 03.28.2018_v0

This is an evaluation of candidate navigation solutions for GPS free inspection tools that can be used in tours of large building interiors. In principle, COTS portable inertial motion unit (IMU) sensors with satisfactory accuracy, SWAP (size, weight, power), low error, and bias drift can provide sufficiently accurate dead reckoning navigation in a large building in the absence of GPS. To explore this assumption, the capabilities of representative IMU navigation sensors to meet these requirements will be evaluated, starting with a market survey, and then carrying out a basic analysis of these sensors using LLNL’s navigation codes.

42 ENGINEERING↗

Safeguards Technology Development Program 3rd Quarter FY 2018 Report June 30, 2018 GPS-Free Navigation in Buildings

This is an evaluation of candidate navigation solutions for GPS free inspection tools that can be used in tours of large building interiors. In principle, COTS portable inertial motion unit (IMU) sensors with satisfactory accuracy, SWAP (size, weight, power), low error, and bias drift can provide sufficiently accurate dead reckoning navigation in a large building in the absence of GPS. To explore this assumption, the capabilities of representative IMU navigation sensors to meet these requirements will be evaluated and field tested, starting with a market survey. To test the candidate COTS IMUs drawn from the market survey, we will design and fabricate a person-portable backpack for testing. We will provide a mobile power supply and data collection port. Then, we will test the IMUs on interior building tours at LLNL, finally carrying out an analysis of these sensors’ performance using LLNL’s navigation codes.

47 OTHER INSTRUMENTATION↗

Safeguards Technology Development Program 4th Quarter FY 2018 Report September 30, 2018

This is an evaluation of candidate navigation solutions for GPS free inspection tools that can be used in tours of large building interiors. In principle, COTS portable inertial motion unit (IMU) sensors with satisfactory accuracy, SWAP (size, weight, power), low error, and bias drift can provide sufficiently accurate dead reckoning navigation in a large building in the absence of GPS. To explore this assumption, the capabilities of representative IMU navigation sensors to meet these requirements will be evaluated and field tested, starting with a market survey. To test the candidate COTS IMUs drawn from the market survey, we will design and fabricate a person-portable backpack for testing. We will provide a mobile power supply and data collection port. Then, we will test the IMUs on interior building tours at LLNL, finally carrying out an analysis of these sensors’ performance using LLNL’s navigation codes.

42 ENGINEERING↗

Failure detection and isolation of redundant inertial systems for Space Shuttle

A failure detection and isolation technique is presented for application to 'off-the-shelf' type four-gimbaled inertial measurement units (IMUs) such as the KT-70 or Carousel IV. This study concentrates initially upon actual four-gimbaled IMU performance requirements for current Space Shuttle booster and orbiter mission phases. When this information is obtained for a simplex system, the remaining area of study necessary to attain redundant IMU capabilities is the establishment of mission-dependent performance failure detection thresholds. These thresholds, then, permit a careful evaluation of the capabilities of various 'off-the-shelf' four gimbaled IMUs to satisfy the Shuttle mission performance requirements with various failure detection and isolation methods.

Brown, H. E.↗

Dispersion analysis and linear error analysis capabilities of the space vehicle dynamics simulation program

Previous error analyses conducted by the Guidance and Dynamics Branch of NASA have used the Guidance Analysis Program (GAP) as the trajectory simulation tool. Plans are made to conduct all future error analyses using the Space Vehicle Dynamics Simulation (SVDS) program. A study was conducted to compare the inertial measurement unit (IMU) error simulations of the two programs. Results of the GAP/SVDS comparison are presented and problem areas encountered while attempting to simulate IMU errors, vehicle performance uncertainties and environmental uncertainties using SVDS are defined. An evaluation of the SVDS linear error analysis capability is also included.

Snow, L. S.↗

Redundant Strapdown Laser Gyro Navigation System

For the last several years, NASA has pursued the development of low-cost high-reliability inertial navigation systems that would satisfy a broad spectrum of future space and avionics missions. Two specific programs have culminated in the construction of a Redundant Strapdown Laser Gyro Navigation System. These two programs were for development of a space ultrareliable modular computer (SUMC) and a redundant laser gyro inertial measurement unit (IMU). The SUMC is a digital computer that employs state-of-the-art large-scale integrated circuits configured in a functional modular breakdown. The redundant laser gyro IMU is a six-pack strapdown sensor package in a dodecahedron configuration which uses six laser gyros to provide incremental angular positions and six accelerometers for linear velocity outputs. The sensor arrangement allows automatic accommodation of two failures; a third failure can be tolerated provided it can be determined. The navigation system also includes redundant power supplies, built-in test-equipment (BITE) circuits for failure detection, and software which provides for navigation, redundancy management, and automatic calibration and alignment.

Mcpherson, B. W.↗

Space shuttle navigation analysis. Volume 2: Baseline system navigation

Studies related to the baseline navigation system for the orbiter are presented. The baseline navigation system studies include a covariance analysis of the Inertial Measurement Unit calibration and alignment procedures, postflight IMU error recovery for the approach and landing phases, on-orbit calibration of IMU instrument biases, and a covariance analysis of entry and prelaunch navigation system performance.

Jones, H. L.↗

GPS aiding of ocean current determination

The navigational accuracy of an oceangoing vessel using conventional GPS p-code data is examined. The GPS signal is transmitted over two carrier frequencies in the L-band at 1575.42 and 1227.6 MHz. Achievable navigational uncertainties of differenced positional estimates are presented as a function of the parameters of the problem, with particular attention given to the effect of sea-state, user equivalent range error, uncompensated antenna motion, varying delay intervals, and reduced data rate examined in the unaided mode. The unmodeled errors resulting from satellite ephemeris uncertainties are shown to be negligible for the GPS-NDS (Navigation Development) satellites. Requirements are met in relatively calm seas, but accuracy degradation by a factor of at least 2 must be anticipated in heavier sea states. The aided mode of operation is examined, and it is shown that requirements can be met by using an inertial measurement unit (IMU) to aid the GPS receiver operation. Since the use of an IMU would mean higher costs, direct Doppler from the GPS satellites is presented as a viable alternative.

Mohan, S. N.↗