Search NASA⌕ Search

SEARCH · Search NASA

Results for “INHALATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding.

60 APPLIED LIFE SCIENCES↗

Broadly neutralizing humanized SARS-CoV-2 antibody binds to a conserved epitope on Spike and provides antiviral protection through inhalation-based delivery in non-human primates

The COVID-19 pandemic represents a global challenge that has impacted and is expected to continue to impact the lives and health of people across the world for the foreseeable future. The rollout of vaccines has provided highly anticipated relief, but effective therapeutics are required to further reduce the risk and severity of infections. Monoclonal antibodies have been shown to be effective as therapeutics for SARS-CoV-2, but as new variants of concern (VoC) continue to emerge, their utility and use have waned due to limited or no efficacy against these variants. Furthermore, cumbersome systemic administration limits easy and broad access to such drugs. As well, concentrations of systemically administered antibodies in the mucosal epithelium, a primary site of initial infection, are dependent on neonatal Fc receptor mediated transport and require high drug concentrations. To reduce the viral load more effectively in the lung, we developed an inhalable formulation of a SARS-CoV-2 neutralizing antibody binding to a conserved epitope on the Spike protein, ensuring pan-neutralizing properties. Administration of this antibody via a vibrating mesh nebulization device retained antibody integrity and resulted in effective distribution of the antibody in the upper and lower respiratory tract of non-human primates (NHP). In comparison with intravenous administration, significantly higher antibody concentrations can be obtained in the lung, resulting in highly effective reduction in viral load post SARS-CoV-2 challenge. This approach may reduce the barriers of access and uptake of antibody therapeutics in real-world clinical settings and provide a more effective blueprint for targeting existing and potentially emerging respiratory tract viruses.

60 APPLIED LIFE SCIENCES↗

A Review of Variables Impacting the Indoor Inhalation Radon Equilibrium Factor (FEQ)

With radon and its daughter products estimated as the second leading cause of lung cancer in the United States, it is imperative to understand their relative equilibrium inside commercial, community, and residential dwellings. The radon indoor inhalation fractional equilibrium factor (F eq ) quantifies the disequilibrium between radon and its progeny in indoor air, and recent advances have shown how air exchange rates (ACH) influence F eq . These numerically derived ACH-dependent F eq values are incorporated into the U.S. EPA's Radon Vapor Intrusion Screening Level (RVISL) calculator, which assists risk assessors in evaluating radon exposure. To advance the risk assessment science of actinon (Rn-219), thoron (Rn-220), and radon (Rn-222), the impact of variables such as indoor aerosol concentration and composition, outdoor air quality, household-specific characteristics, and environmental/meteorological conditions on the F eq must be examined. The primary objective of this research is to analyze these additional variables to determine the usefulness of incorporating such adjustment factors into the RVISL calculator and to identify areas of future research. Studies regarding the influence of these parameters are presented along with recommendations regarding the adjustment of the numerically derived F eq value. For example, elevated indoor aerosol concentrations, such as those originating from outdoor PM 2.5 or cigarette smoke, increase the abundance of accumulation- mode particles indoors, which in turn raises F eq values by facilitating the attachment of radon progeny to these aerosols. Smoking increases both the bronchial dose and F eq , while regions with high smog levels demonstrate the impact of regional air quality on F eq . In contrast, air cleaning systems and purifiers have been shown to reduce the F eq , suggesting that these systems could help mitigate radon exposure. Additionally, higher F eq values are typically observed during winter when ventilation rates are lower. This paper presents adjustment factors that may be applied to the RVISL F eq , emphasizing the need for further research to refine these variables and ensure accurate risk assessments in diverse environments. Applying these adjustment factors will minimize calculator over- and underestimations, providing a more accurate representation of the real-world risk associated with radon.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Analysis of Inhalation Dose Coefficients for Nuclear Incident Response

This study addressed the need to characterize variability in inhalation dose coefficients due to uncertainties in respiratory tract deposition, systemic biokinetics, and physiological parameters. A Python-based implementation of the International Commission on Radiological Protection Publication 66 Human Respiratory Tract Model was developed called the Radiological Exposure Dose Calculator (REDCAL) to propagate parameter uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Olfactory bulb units - Activity correlated with inhalation cycles and odor quality.

Single olfactory bulb units were studied in two macrosmatic species of rodents under conditions intended to preserve the cyclical stimulation which normally accompanies nasal breathing. Patterns of unit activity related to the inhalation cycle were observed in all animals, often in the absence of specific stimuli, and could not be explained in simple mechanical terms. Distinctive changes in these patterns occurred in response to certain odors, and were generally independent of changes in the overall firing frequency. These findings indicate that a change in the overall firing frequency of unit discharges is neither a necessary nor sufficient measure of responsiveness to odors in the rodent olfactory bulb, and that stimulus-specific temporal distributions of unit firing may be involved in olfacto-endocrine activities.

Macrides, F.↗

Improved inhalation technology for setting safe exposure levels for workplace chemicals

Threshold Limit Values recommended as allowable air concentrations of a chemical in the workplace are often based upon a no-observable-effect-level (NOEL) determined by experimental inhalation studies using rodents. A 'safe level' for human exposure must then be estimated by the use of generalized safety factors in attempts to extrapolate from experimental rodents to man. The recent development of chemical-specific physiologically-based toxicokinetics makes use of measured physiological, biochemical, and metabolic parameters to construct a validated model that is able to 'scale-up' rodent response data to predict the behavior of the chemical in man. This procedure is made possible by recent advances in personal computer software and the emergence of appropriate biological data, and provides an analytical tool for much more reliable risk evaluation and airborne chemical exposure level setting for humans.

Stuart, Bruce O.↗

Toxicokinetics of inhaled bromotrifluoromethane (Halon 1301) in human subjects

Bromotrifluoromethane (Halon 1301, CBrF3), is used as a fire extinguishant in the Space Shuttle, where several scenarios, such as a fire or a faulty alarm, could lead to its discharge resulting in a Halon 1301 concentration of up to 1 percent in the cabin atmosphere. The effect of Halon 1301 on mental performance and physiologic function was investigated in a NASA-sponsored human inhalation study in which four pairs of male subjects were each exposed in a double-blind fashion for 24 hr to 1 percent Halon 1301 and to air in two exposures about 1 week apart. Blood and breath samples from the exposed subjects were collected to provide dosimetric and toxicokinetic information. Halon 1301 blood levels increased rapidly and approached a steady state within 2 hr of the beginning the exposure; the steady-state concentration was approximately 3-4.5 microg/ml. Breath samples collected during exposures closely reflected chamber concentrations. Analysis of postexposure blood samples revealed that Halon 1301 was eliminated biphasically with an average t(1/2) alpha and t(1/2) beta of 4.5 min and 200 min, respectively.

Lam, C. W.↗

Inhalation Toxicity of Ground Lunar Dust Prepared from Apollo-14 Soil

Within the decade one or more space-faring nations intend to return humans to the moon for more in depth exploration of the lunar surface and subsurface than was conducted during the Apollo days. The lunar surface is blanketed with fine dust, much of it in the respirable size range (<10 micron). Eventually, there is likely to be a habitable base and rovers available to reach distant targets for sample acquisition. Despite designs that could minimize the entry of dust into habitats and rovers, it is reasonable to expect lunar dust to pollute both as operations progress. Apollo astronauts were exposed briefly to dust at nuisance levels, but stays of up to 6 months on the lunar surface are envisioned. Will repeated episodic exposures to lunar dust present a health hazard to those engaged in lunar exploration? Using rats exposed to lunar dust by nose-only inhalation, we set out to investigate that question.

James, John T.↗

Tank 11H Low Temperature Aluminum Dissolution and Inhalation Dose Potential Analyses at Savannah River Site – 26018

Currently, there is approximately 34 million gallons of high-level radioactive tank waste in the Tank Farm at the Savannah River Site (SRS). The ultimate goal of operations at the Tank Farm is to remove the high level waste (HLW) from the tanks followed by stabilization of the waste through vitrification of the HLW into glass or grouting the decontaminated waste into saltstone. After bulk removal of the HLW consisting of sludge, saltcake, and supernatant, further efforts are made to reduce the residual waste present in the tank in order to declare preliminary cease waste removal (PCWR) signifying completion of HLW removal. These reduction efforts can include tank washing to remove soluble salts and radioisotopes and dissolution of solids including aluminum. Aluminum in the form of gibbsite and boehmite is relatively insoluble in water. Through addition of aqueous sodium hydroxide, the aluminum can be dissolved at mild temperatures. In order for the waste tank to meet closure mode requirements of the Concentration, Storage, and Transfer Facilities (CSTF), which includes the Tank Farm, Documented Safety Analysis (DSA), a component of the safety basis, the inhalation dose potential (IDP) and the radiolytic hydrogen generation rate of the stored waste must be demonstrated to be lower than their respective designated limits. These parameters are calculated from measured radiochemical analyses of isotopes that emit a high amount of radioactivity including Cs-137, Sr-90, Pu-238, Pu-239, Pu-240, Pu-241, Am-241, and Cm-244. Following the low temperature aluminum dissolution (LTAD) process, Tank 11H slurry samples were pulled from the tank and sent to Savannah River National Laboratory (SRNL) to measure the extent of aluminum dissolution, hydroxide concentration, densities of slurry and supernatant, weight percent solids analyses, and radionuclide activities. The analyses of the composite sample found that approximately 90% of the total aluminum in the slurry was dissolved, indicating successful reduction of the insoluble aluminum in the waste tank. Additionally, the weight percent insoluble solids (slurry basis) measurement of the composite sample was found to be approximately 1%, demonstrating that minimal solids still remain in the tank. Finally, the radiochemical analyses of the composite sample determined that the waste contents of the tank met the IDP and radiolytic hydrogen generation rate requirements of the CSTF DSA. These measurements have shown that the LTAD process in Tank 11H was successful in waste reduction efforts and a positive step towards declaring PCWR and tank closure at SRS.

Dekarske, John [Savannah River National Laboratory↗

Temporally and Spatially Resolved x-ray Fluorescence Measurements of in-situ Drug Concentration in Metered-Dose Inhaler Sprays

Drug concentration measurements in MDI sprays are typically performed using particle filtration or laser scattering. These techniques are ineffective in proximity to the nozzle, making it difficult to determine how factors such as nozzle design will affect the precipitation of co-solvent droplets in solution-based MDIs, and the final particle distribution. In optical measurements, scattering from the constituents is difficult to separate. We present a novel technique to directly measure drug distribution. A focused x-ray beam was used to stimulate x-ray fluorescence from the bromine in a solution containing 85% HFA, 15% ethanol co-solvent, and 1 / IPBr. Instantaneous concentration measurements were obtained with 1 ms temporal resolution and 5 spatial resolution, providing information in a region that is inaccessible to many other diagnostics. The drug remains homogeneously mixed over time, but was found to be higher at the centerline than at the periphery. This may have implications for oropharyngeal deposition in vivo. Measurements in the dynamic, turbulent region of MDIs allow us to understand the physical links between formulation, inspiration, and geometry on final particle size and distribution. This will ultimately lead to a better understanding of how MDI design can be improved to enhance respirable fraction.

fluorescence↗