Search NASA⌕ Search

SEARCH · Search NASA

Results for “INLET FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

HERO WEC V1.0 - WEC-Sim Detailed Simulation Runs and Summary Data

Data sets from simulation runs include 144 wave cases that were run based on the WEC-Sim model (https://mhkdr.openei.org/submissions/483). The 144 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 4.0m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 200 second ramp time and a total simulation time of 2,200 seconds. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the sim runs, in the same increments. The following matrices are included: - Mechanical Power Input: Absorbed power calculated using linear input velocity at PTO (power take-off) multiplied by winch tension. - Mechanical Power Output: The hydraulic power calculated at the pump output prior to the pressure relief valve dump. - Feed Pressure: Average pressure at RO (reverse osmosis) input prior to pre-filters - RO Power Input: The hydraulic power calculated at the RO system inlet, accounts for flow loss due to pressure relief valve - Water Production: Average clean water flow at RO output

16 TIDAL AND WAVE POWER↗

Advancing Pressure Gain Combustion for Terrestrial Turbine Systems

The principal objectives of this project were to demonstrate the operability of a natural gas - air RDE at gas turbine engine cycle conditions. To achieve these goals, our specific tasks were to 1) characterize the dynamic injection and mixing performance of candidate injectors, 2) assess the engine operability via interrogation of spatio-temporal dynamics of combustor inlet and exit flows, 3) measure the engine emissions, and 4) complete an overall assessment of the pressure gain potential of the device. In order to advance RDE technology to the greatest extent possible, the reactants and experimental conditions were chosen to replicate combustor and injector conditions in a terrestrial power generation system. This path was taken because the scaling of combustion devices is, in general, an immature area given the challenges of interrelated mixing and chemical kinetics processes both of which scale with operating conditions.

03 NATURAL GAS↗

Safety Analysis for the Versatile Test Reactor Conceptual Design

Safety analysis simulations have been carried out using the SAS4A/SASSYS-1 safety analysis code system to update the baseline set of results for the Versatile Test Reactor conceptual design. Results from a previous revision of this work provided input for the Conceptual Safety Design Report summarizing the overall safety basis for the VTR. This work will also support future analyses that will be required for Chapter 13, “Accident Analysis,” of a preliminary safety analysis report. A number of transients have been evaluated based on categories of postulated accident sequences suggested for consideration in NUREG-1537. Ultimately, the full spectrum of event initiators and subsequent accident sequences will be defined through a probabilistic risk assessment of the plant design following the implementation of the Licensing Modernization Project guidelines as described in the VTR Safety Design Strategy. Since that process is ongoing, the present analysis addresses several transients that are expected to be bounding accident scenarios that represent the three key ways to perturb a reactor: through changes to the core inlet temperature, mass flow rate, or reactivity. These correspond to a loss of heat sink (LOHS), loss of flow (LOF) or station blackout (SBO), and transient overpower (TOP), respectively. Both Protected and Unprotected versions of these transients have been evaluated, along with additional transients that include transient overpower with one stuck rod, pump coast-down failures, seismic events, and overcooling events. At the current stage of design, transient simulation results for the Versatile Test Reactor indicate that large safety margins exist for many event initiators. However, several “enabling” assumptions have been made, in terms of both design features and design limits, in order to perform the analyses; and these assumptions will need to be revised as the design matures. In addition, a larger spectrum of events needs to be evaluated as part of the on-going probabilistic risk assessment process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Towards a NEAMS-based high-fidelity model of the MARVEL reactor

This report outlines the progress of Idaho National Laboratory in developing a high-fidelity and high-resolution model of the Microreactor Applications Research Validation and Evaluation reactor. The model was developed under the Nuclear Energy Advanced Modeling and Simulation microreactor application driver at Idaho National Laboratory. The overarching objective of this activity is the development of a high-fidelity multiphysics MARVEL model using NEAMS tools, and to verify and validate NEAMS tools against MARVEL reference simulation and experimental data, respectively. This is a unique opportunity to conduct multiphysics analysis on a soon-to-be-deployed microreactor. This multiphysics model developed under the NEAMS-funded INL microreactor application driver leverages three single-physics models coupled via the MOOSE’s MultiApp and Transfer systems. The latter systems enable in-memory data transfer between MOOSE-based and MOOSE-wrapped applications. The first single-physics model, that functions as main application, leverages Griffin to model the neutron transport in the core through the discontinuous finite element (DFEM) discrete ordinates solver (SN). Several optimization flags that were developed by the Griffin developer team were beta-tested to enhance the solver’s performance. These include the combined use of using_average_xs and update_averaged_xs_on that enable to avoid expensive on-the-fly cross sections evaluations at each linear iterations in favor of evaluations of the macroscopic cross sections at each Picard iteration. The second single-physics model uses BISON to handle solid heat transfer and asymptotic hydrogen redistribution analysis in the fuel. While the model returns consistent results for the temperature and hydrogen distribution in the fuel, a mismatch was noticed in the calculated temperature in the reflector due to the value of the gap conductance used in our model. Ongoing investigations are being performed to assess the origin of this discrepancy. Finally, the System Analysis Module (SAM) was used to model the flow of the sodium-potassium eutectic in the primary loop. A first verification was also performed showing good agreement in terms of mass flow rate and inlet temperature. All mesh files were generated using the MOOSE Reactor module, removing the need for external meshing tools. Notably, this workscope represents one of the initial applications of the MOOSE Reactor module for modeling highly irregular geometries. The use of the reactor module significantly streamlined the mesh generation process. The full multiphysics mode, that combines all the single physics models, was leveraged to conduct initial steady-state multiphysics simulations to compute power, and temperature distribution in the reactor. Initial testing was performed for transient simulations as well. In this case, the new checkpoint restart capability for eigenvalue calculations was tested showing the capability for streamlined restart of transient calculations. Future work will focus on improving the fidelity of the model by performing comprehensive code-to-code comparisons. For instance, the full-core Griffin neutronics model will be benchmarked against MCNP reference results, that were provided by the MARVEL design team. Additionally, the SAM T/H model will be verified against reference RELAP-5 results for selected accident scenarios. Besides code-to-code verification exercises, the model fidelity will be improved by replacing the single-channel SAM model with a more complex SAM-Pronghorn coupled model, in which the sub-channel capability is deployed to obtain radial temperature resolution in the coolant. This model will be developed in synergy with the NEAMS thermal hydraulics team.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Transfer of an Integrated Counterflow Ceramic Heat Exchanger

The ceramic-based heat exchanger is one of the leading contenders for high-efficiency concentrating solar power plants using a molten salt heat transfer fluid and a supercritical carbon dioxide Brayton power cycle operating at temperatures above 700 °C due to the excellent resistance of ceramics to corrosion, oxidation, erosion, creep, and fouling. In the present study, the thermal performance of a ceramic silicon carbide prototype heat exchanger, with semi-elliptical heat transfer channels, integrated header channels, and a counterflow configuration fabricated by using binder jetting additive manufacturing, was experimentally investigated. Experimental heat transfer tests of the prototype were conducted at high temperatures and under various test fluid flow rates and inlet temperatures. The experimental heat transfer rates compared favorably with simulation predictions.

Yu, Wenhua (ORCID:0000000219457014)↗

SMPS data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow, 1.0 LPM, is directed through TSI's 0.071 cm impactor attached to the classifier of the SMPS setup. The SMPS’s DMA and CPC are connected through a 20.3 cm length of 0.48 cm diameter tubing. Measured SMPS size distributions were used to calculate size-dependent particle losses for each SMPS scan. Particle losses from diffusion (based on Kesten, 1991 and Gormley, 1949) and inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977) were included in the loss calculation. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

54 ENVIRONMENTAL SCIENCES↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

Flow friction in a wide rectangular duct with a beveled inlet: Informal Notes of Fundamental Fluid Physics Studies

Fundamental streamwise pressure distributions were measured at Idaho State University to address a primary objective of obtaining insight into the apparent evolution of air flow regimes at moderate Reynolds numbers in thin, wide rectangular ducts with converging inlets. Ducts of 3.030 and 4.077 mm spacings s (called three and four mm), having non-dimensional lengths of (L/s) ≈ 500.8 and 372.2 and widths (W/s) ≈ 114.6 and 83.2, respectively, were compared. Flow rates ranged from Reynolds numbers based on hydraulic diameter (Re Dh ) of about 980 to 10,000 and corresponding non-dimensional downstream pressure gradient parameters (-K p ) covered the range 0.038 to 0.0061, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pilot-pressure-controlled flow valve and fluid system containing same

In a thermal fluid system, a control valve includes a flow valve and a solenoid pilot valve. The flow valve has an inlet and an outlet; a control chamber for receiving a pilot pressure; and a valve member operable by the pilot pressure to selectively open and close a fluid path from the inlet to the outlet. The pilot pressure acts in a closing direction of the flow valve. The pilot valve provides the pilot pressure to the control chamber and is a 3/2 way valve with a first port in fluid communication with the control chamber, a second port to be connected to a pressure source, and a third port. The pilot valve has a first position connecting the first port with the second port and a second position connecting the first port with the third port.

Chowdhury, Sourav↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

Measurements of the Flow in the Vicinity of an Additively Manufactured Turbine Leading-Edge Using X-Ray Particle Tracking Velocimetry

X-ray particle tracking velocimetry (PTV) is performed, for the first time, to measure the velocity field inside a leading-edge of a turbine blade made by laser-additive-manufacturing (LAM) process. The traditional showerhead holes were replaced by a porous matrix in the leading-edge. The flow through such a leading-edge piece cannot be faithfully recreated by traditional prototype testing methods due to the surface roughness and imperfections caused by LAM process. Hence, direct measurement is the only option. However, it is difficult to measure flow inside such pieces with traditional velocimetry measurements due to the existence of metallic walls. Moreover, small internal size and high flow speeds call for a measurement technique with high spatial and temporal resolutions. To address these issues, we performed time-resolved X-ray PTV using the Advanced Photon Source (APS) synchrotron facility at the Argonne National Laboratory (ANL). A hydraulic system was constructed to run water, mixed with seeding particles, through the leading-edge piece. A high-speed camera captured the images of the seeding particles, which were later processed to create particle tracks. The time-averaged velocity field showed distinct pairs of vortices located in front of the porous outlet inside the leading-edge piece. The inlet channel showed reversed flow due to partial obstruction by the porous inlet of the test piece. Such knowledge of the flow field inside a leading-edge of a turbine blade will help us to design better cooling paths leading to higher cooling efficiency and increased life-span of a turbine blade.

42 ENGINEERING↗

Modeling of vapor-liquid interactions in condensing ejectors

Ejectors are compact mechanical devices that utilize the expansion of a high-pressure primary fluid to entrain and compress a low-pressure secondary fluid by means of momentum transfer between the two streams of fluid. Condensing ejectors feature both momentum and heat transfer through the interaction between the vapor and liquid streams. The goal of this paper is to develop and validate a one-dimensional slug flow model to simulate the vapor–liquid interactions in two types of condensing ejectors – one with primary liquid and secondary vapor flows (Type I), and the other with primary vapor and secondary liquid flows (Type II). Control volume analysis of the mass, momentum, and energy balance in each phase and across the interface was conducted for the ejectors. The slug flow models for both types of ejectors are validated with published results in the literature. The friction coefficient on the inner wall of the ejectors and the interfacial heat transfer coefficient are identified as controlling parameters for the ejector performance in terms of pressure and temperature distributions along the axis. The detailed parametric study shows that the liquid inlet velocity and mixing tube diameter have a significant impact on the performance of the Type I ejectors, and the performance of the Type II ejectors is mainly controlled by the secondary liquid flow inlet temperature.

42 ENGINEERING↗

A methodology for domain overlapping coupling of thermal-hydraulic systems

Multi-scale coupling has increasingly drawn attention as a promising approach for modeling thermal systems. Traditional system codes provide fast and robust predictions at the plant scale, while high-fidelity computational fluid dynamics (CFD)-based tools resolve localized flow and heat transfer phenomena with greater accuracy. By combining these complementary strengths, co-simulations enable multi-scale analysis that would otherwise be computationally prohibitive for a standalone CFD code. Here, this work introduces a robust and problem-agnostic domain overlapping (DO) coupling between the system thermal-hydraulic (STH) code System Analysis Module (SAM) and the coarse-mesh CFD code Pronghorn. Both applications belong to the Comprehensive Reactor Analysis Bundle (BlueCRAB) code suite, a code suite in active development at the Idaho National Laboratory (INL), tailored for multi-physics analysis of advanced reactors. Unlike previous approaches, BlueCRAB supports an agnostic interface between codes based on different fidelity, while its coupling formulation can address arbitrary flow geometries with multiple inlets and outlets in coupled components. The implemented method leads to consistent pressure drops, enthalpies, and scalar concentrations between coupled SAM and Pronghorn simulations. The methodology is demonstrated through two verification tests, which ensure the numerical consistency and conservation across the codes, and through one validation test against experimental data. The proposed problems explore different physical aspects inherent to thermal systems, with particular attention given to nuclear reactor analysis. These include buoyancy-driven flows, complex flow patterns, and setups with multiple inlets and outlets, representing challenges in advanced reactor applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

Light Duty Engine Performance Characteristics with Dimethyl Ether and Propane

Here, this paper explores the performance characteristics of a compression ignition HYUNDAI 2.2L engine operating with Dimethyl Ether (DME). Test are carried out at three operating conditions that weigh heavily in the FTP75 certification cycle (1000rpm-12Nm, 1500rpm-50Nm, 2000rpm-100Nm). The engine features a high-pressure common rail fuel injection system designed to operate with liquified gases. The main component of the fuel system is a high-pressure pump that incorporates an electronic inlet metering valve commanded on a crank-angle base to control the rail pressure. The pump, which requires no pressure regulator, provides the flow needed to the injectors without flow returning to the inlet. This novel fueling system is leveraged in tests that are conducted to examine the impact of EGR, combustion phasing, injection pressure on efficiency and emissions. In addition, the impact of introducing 15% Propane by mass is examined. During the tests, the engine ECU is aided by an Engine Controller High Speed Oversight unit (ECHO) to provide combustion phasing control, improved cylinder-to-cylinder uniformity, and an effective optimization over the testing effort. The use of DME and Propane allowed for peak thermal efficiency of nearly 43%. These fuels enable significant carbon index (CI) reductions over the baseline Diesel fuel, with indications that 50% reduction in CO 2 over the Diesel engine are possible.

33 ADVANCED PROPULSION SYSTEMS↗