Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Identification and Description of a Silicic Volcaniclastic Layer in Gale Crater, Mars, Using Active Neutron Interrogation

The Dynamic Albedo of Neutrons instrument aboard the Mars Science Laboratory rover, Curiosity, has been used to map a stratigraphically-conformable layer of high-SiO 2 material in Gale crater. Previous work has shown this material contains tridymite, a high-temperature/low-pressure felsic mineral, interpreted to have a volcanic source rock. We describe several characteristics including orientation, extent, hydration, and geochemistry, consistent with a volcaniclastic material conformably deposited within a lacustrine mudstone succession. Relationships with widely dispersed alteration features and orbital detections of hydrated SiO 2 suggest that this high-SiO 2 layer extends at least 17 km laterally. Mineralogical abundances previously reported for this high-SiO 2 material indicated that hydrous species were restricted to the amorphous (non-crystalline) fraction, which is dominated by SiO2. The low mean bulk hydration of this high-SiO 2 layer (1.85 ± 0.13 wt.% water-equivalent hydrogen) is consistent with silicic glass in addition to opal-A and opal- CT. Persistent volcanic glass and tridymite in addition to opal in an ancient sedimentary unit indicates that the conversion to more ordered forms of crystalline SiO 2 has not proceeded to completion and that this material has had only limited exposure to water since it originally erupted, despite having been transported in a uviolacustrine system. Our results, including the conformable nature, large areal extent, and presence of vol- canic glass, indicate that this high-SiO 2 material is derived from the product of evolved magma on Mars. This is the rst identi cation of a silicic volcaniclastic layer on another planet, and has important implications for magma evolution mechanisms on single-plate planets.

58 GEOSCIENCES↗

Characterization of MKIDs for CMB Observation at 220 GHz With the South Pole Telescope

We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_{i} = 4.8 \times 10^{5}$, aluminum inductor transition temperature $T_{c} = 1.19$K, and kinetic inductance fraction $\alpha _{k} = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $\eta \sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$for both detector orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Mapping of Surface Charge Density on Arbitrary Dielectric Objects

A system to map surface charge densities on dielectric objects – e.g. PTFE, PMMA, and PA6 – is described to study maximum surface charge limits discharge and decay characteristics. Two electromechanical movements are used to achieve these goals: a three-axis robotic arm with an electrostatic probe and a three-axis auxiliary movement fitted with a current viewing resistor and laser displacement sensor. Dielectric objects no larger than a cylinder of eight-inch diameter and twelve inches in height are analyzed to create surface point clouds and generate a set of scan points. The arbitrary object is positioned upon a rotational axis with a laser displacement sensor oriented radially towards the rotational axis of the platform to determine the object’s physical limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties). To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties).To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of radial neutral density profiles from Balmer- α emission in Wendelstein 7-X

Radial neutral density profiles are estimated from measurements of passive H α emission in the Wendelstein 7-X stellarator. To parametrize the generally three-dimensional distribution with a low number of degrees of freedom, the neutral density is reduced to a flux surface quantity. Accounting for emission from excitation and recombination processes, neutral density profiles are derived independently for each of the available lines of sight. Density profiles obtained from the different viewing geometries are found to vary within one order of magnitude. Toroidally oriented lines of sight predict systematically lower neutral densities when compared to poloidally oriented ones. This discrepancy is attributed to the simplifications inherent in the imposed model and significant differences in integration volumes across the viewing geometries. In line with expectations, obtained neutral densities are found to decrease with increasing plasma density. Key restrictions of the model include the reduction of the neutral density to a flux surface quantity, uncertainties in the plasma profiles and instrument function, and line integration effects outside the last closed flux surface.

Wendelstein 7-X↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Characterization of MoS 2 films via simultaneous grazing incidence X-ray diffraction and grazing incidence X-ray fluorescence (GIXRD/GIXRF)

Physical vapor deposited (PVD) molybdenum disulfide (nominal composition MoS 2 ) is employed as a thin film solid lubricant for extreme environments where liquid lubricants are not viable. The tribological properties of MoS 2 are highly dependent on morphological attributes such as film thickness, orientation, crystallinity, film density, and stoichiometry. These structural characteristics are controlled by tuning the PVD process parameters, yet undesirable alterations in the structure often occur due to process variations between deposition runs. Nondestructive film diagnostics can enable improved yield and serve as a means of tuning a deposition process, thus enabling quality control and materials exploration. Grazing incidence X-ray diffraction (GIXRD) for MoS 2 film characterization provides valuable information about film density and grain orientation (texture). However, the determination of film stoichiometry can only be indirectly inferred via GIXRD. The combination of density and microstructure via GIXRD with chemical composition via grazing incidence X-ray fluorescence (GIXRF) enables the isolation and decoupling of film density, composition, and microstructure and their ultimate impact on film layer thickness, thereby improving coating thickness predictions via X-ray fluorescence. We have augmented an existing GIXRD instrument with an additional X-ray detector for the simultaneous measurement of energy-dispersive X-ray fluorescence spectra during the GIXRD analysis. This combined GIXRD/GIXRF analysis has proven synergetic for correlating chemical composition to the structural aspects of MoS 2 films provided by GIXRD. We present the usefulness of the combined diagnostic technique via exemplar MoS 2 film samples and provide a discussion regarding data extraction techniques of grazing angle series measurements.

MoS2↗

Hybrid Machine Learning for Scanning Near-Field Optical Spectroscopy

The underlying physics behind an experimental observation often lacks a simple analytical description. This is especially the case for scanning probe microscopy techniques, where the interaction between the probe and the sample is nontrivial. Realistic modeling to include the details of the probe is always exponentially more difficult than its "spherical cow" counterparts. On the other hand, a well-trained artificial neural network based on real data can grasp the hidden correlation between the signal and sample properties. In this work, we show that, via a combination of model calculation and experimental data acquisition, a physics-infused hybrid neural network can predict the tip-sample interaction in the widely used scattering-type scanning near-field optical microscope. This hybrid network provides a long-sought solution for accurate extraction of material properties from tip-specific raw data. The methodology can be extended to other scanning probe microscopy techniques as well as other data-oriented physical problems in general.

36 MATERIALS SCIENCE↗

Super-Resolution Airy Disk Microscopy of Individual Color Centers in Diamond

Super-resolution imaging techniques enable nanoscale microscopy in fields such as physics, biology, and chemistry. However, many super-resolution techniques require specialized optical components, such as a helical-phase mask. In this work, we present a novel technique, super-resolution Airy disk microscopy, that can be used in a standard confocal microscope without any specialized optics. We demonstrate this technique, in combination with ground state depletion, to image and control nitrogen-vacancy (NV) centers in bulk diamond below the diffraction limit. A greater than 14-fold improvement in resolution compared to the diffraction limit is achieved, corresponding to a spatial resolution of 16.9(8) nm for a 1.3 NA microscope with 589 nm light. We make use of our enhanced spatial resolution to control the spins states of individual NV centers separated from each other by less than the diffraction limit, including pairs sharing the same orientation that are indistinguishable with a conventional electron spin resonance measurement.

36 MATERIALS SCIENCE↗

Relaxation oscillations in a bipolarised Nd : YAG laser with a Fabry – Perot cavity

Based on the model of a bipolarised laser, which takes into account real orientations of absorbing and emitting dipoles of active centres in the unit cell of an Nd : YAG single crystal, we have shown that the appearance of low-frequency relaxation oscillations requires the participation of both competing pump channels through linearly and circularly polarised dipole transitions. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3–7.5 keV using synchrotron radiation

Verification of physics models and computer simulations are heavily reliant upon the accuracy of experimental measurements. Calibration of instrument responses becomes an important step to achieve this goal. This paper presents systematic studies of bent potassium acid phthalate (KAP) crystals using Lawrence Berkeley National Laboratories, Advanced Light Source, beamline 9.3.1 in the energy range of 2.3 to 7.5 keV. A set of KAP crystals, gradually bent from flat up to a 50.8 mm cylindrical curvature. The measured integrated reflectivity for this set of KAP crystals shows good agreement with the X-ray Oriented Program (XOP) calculations when adjusting the Debye–Waller temperature factor and using the multilamellar model in the calculations. Significant differences in rocking curve profiles were observed between experimental measurements and theory. A forward convolution model and software code were developed to include experimental parameters, allowing the investigation of the difference between measurements and calculations. After considering the experimental parameters, good agreements were obtained for the rocking curve profiles for all bending radii with a unique set of parameters. Our results show that XOP can be a useful and reliable tool to predict performance of cylindrically bent KAP crystals in this energy range.

Wu, Ming↗