Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS, LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A comparison of high-temperature flare models with observations and implications for the low-temperature flare

EUV data from the Harvard College Observatory and Naval Research Laboratory instruments on board the Skylab Apollo telescope mount, together with SOLRAD 9 X-ray data, are analyzed in order to empirically deduce the variation of emission measure with temperature in the atmosphere of a number of solar flares. A 'mean' differential emission measure profile Q(T) for a flare is constructed which is then compared with the profile predicted by a number of theoretical models. It is found that realistic flare models must include both conductive and radiative terms in the energy equation, and that hydrodynamic terms may be important at low temperatures. The implications of the results obtained are discussed for flare models in general and it is shown that the inclusion of the conductive term into models which have hitherto neglected it can perhaps resolve some of the observational difficulties with such models.

Machado, M. E.↗

Observations of large fluxes of He/+/ in the solar wind following an interplanetary shock

Los Alamos Scientific Laboratory instrumentation on Imp 7 has detected large fluxes of He(+) within that volume of solar wind plasma believed to be the solar ejecta driving the interplanetary shock wave disturbance of July 29, 1977. The very high He(+)/He(++) abundance ratio of 0.3 measured during this event suggests that this was solar prominence material only partially ionized by its passage through the corona.

Gosling, J. T.↗

Solar wind iron abundance variations at speeds greater than 600 km/s, 1972-1976

An analysis has been conducted of the Fe/H ratios in the peaks of high-speed streams during the decline of solar cycle 20 and the following minimum (October 1972-December 1976). The response of the 50- to 200-keV ion channel of The Johns Hopkins University Applied Physics Laboratory energetic particle experiments (EPE) on IMP 7 and 8, which is (in the absence of energetic ions) dominated by solar wind iron ions at high solar wind speeds (V approximately equal to or greater than 600 km/s) as inferred from calibrations of flight spare detectors. The conducted Fe measurements have been compared with solar wind H and He parameters from the Los Alamos National Laboratory instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the He parameters. Although the average Fe/H ratios found in the peaks of many steady high-speed streams agree within observational uncertainties with the nominal coronal ratio of 4.7 x 10 to the -5th, abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated high-speed stream. There are, as well, a factor of 2 variations between stream-averaged abundances for recurrent high-speed streams emanating from different coronal holes occurring on the sun on the same solar rotation. Flare-related solar wind flows sometimes show Fe/H ratios enhanced by factors of 4-5 more than in coronal-hole associated, quiet-time streams, while in one case the Fe/H enhancement was still observable one rotation after the flare activity. Over the period 1973-1976, a steady decrease in the average quiet time Fe/H ratio by a factor of approximately 4 is measured on both IMP 7 and 8.

Mitchell, D. G.↗

New identifications of Fe XVII spectral lines in solar flares

The identifications of Fe XVII transitions between the 2s(2)2p(5)3s, 3p, and 3d configurations published by Jupen (1984) are reviewed. The review is based on examining spectroheliograms of solar flares obtained by a Naval Research Laboratory instrument on Skylab (S082-A). Agreement is obtained with the majority of identifications given by Jupen, but different wavelengths are found for a few of the lines. The relative intensities of the lines are qualitatively in agreement with calculations. A broad line at 1153.20 A is identified with the 2p(5)3s(3)P(0)-2p(5)3s(3)P1 forbidden transition of Fe XVII. This line was found in flare spectra obtained by the NRL slit spectrograph on Skylab (S082-B).

Feldman, U.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

Snyder, Robert S.↗

Imaging and nondispersive spectroscopy of soft X rays using a laboratory X-ray charge-coupled-device system

This paper describes the design and performance of a laboratory instrument for imaging and nondispersive spectroscopy of soft X-rays (300 eV to 10 keV) utilizing a virtual-phase CCD. This instrument has achieved a spatial resolution of 22 microns (limited by pixel size) with an overall array area of 584 x 390 pixels. It has achieved an energy resolution of about 140 eV FWHM for single-pixel Fe-55 X-ray events (5.9 keV) with the CCD operated at -30 C. The CCD has been operated in photon-counting mode at room temperature, and X-ray spectra with an energy resolution of about 450 eV at 5.9 keV have been obtained. The low energy X-ray sensitivity of the CCD also has been demonstrated by detecting carbon K-alpha X-rays (277eV).

Luppino, Gerard A.↗

Hybrid Analog/Digital Receiver

Advanced hybrid analog/digital receiver processes intermediate-frequency (IF) signals carrying digital data in form of phase modulation. Uses IF sampling and digital phase-locked loops to track carrier and subcarrier signals and to synchronize data symbols. Consists of three modules: IF assembly, signal-processing assembly, and test-signal assembly. Intended for use in Deep Space Network, but presumably basic design modified for such terrestrial uses as communications or laboratory instrumentation where signals weak and/or noise strong.

Brown, D. H.↗

Plume spectrometry for liquid rocket engine health monitoring

An investigation of Space Shuttle Main Engine (SSME) testing failures identified optical events which appeared to be precursors of those failures. A program was therefore undertaken to detect plume trace phenomena characteristic of the engine and to design a monitoring system, responsive to excessive activity in the plume, capable of delivering a warning of an anomalous condition. By sensing the amount of extraneous material entrained in the plume and considering engine history, it may be possible to identify wearing of failing components in time for a safe shutdown and thus prevent a catastrophic event. To investigate the possibilities of safe shutdown and thus prevent a monitor to initiate the shutdown procedure, a large amount of plume data were taken from SSME firings using laboratory instrumentation. Those data were used to design a more specialized instrument dedicated to rocket plume diagnostics. The spectral wavelength range of the baseline data was about 220 nanometers (nm) to 15 micrometer with special attention given to visible and near UV. The data indicates that a satisfactory design will include a polychromator covering the range of 250 nM to 1000 nM, along with a continuous coverage spectrometer, each having a resolution of at least 5A degrees. The concurrent requirements for high resolution and broad coverage are normally at odds with one another in commercial instruments, therefore necessitating the development of special instrumentation. The design of a polychromator is reviewed herein, with a detailed discussion of the continuous coverage spectrometer delayed to a later forum. The program also requires the development of applications software providing detection, variable background discrimination, noise reduction, filtering, and decision making based on varying historical data.

Powers, William T.↗

Optical radiation measurements II; Proceedings of the Meeting, Orlando, FL, Mar. 27, 28, 1989

The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.

Palmer, James M.↗

Isolated Fast High-Voltage Switching Circuit

Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

Rizzi, Anthony↗

High-performance packaging for monolithic microwave and millimeter-wave integrated circuits

Packaging schemes were developed that provide low-loss, hermetic enclosure for advanced monolithic microwave and millimeter-wave integrated circuits (MMICs). The package designs are based on a fused quartz substrate material that offers improved radio frequency (RF) performance through 44 gigahertz (GHz). The small size and weight of the packages make them appropriate for a variety of applications, including phased array antenna systems. Packages were designed in two forms; one for housing a single MMIC chip, the second in the form of a multi-chip phased array module. The single chip array module was developed in three separate sizes, for chips of different geometry and frequency requirements. The phased array module was developed to address packaging directly for antenna applications, and includes transmission line and interconnect structures to support multi-element operation. All packages are fabricated using fused quartz substrate materials. As part of the packaging effort, a test fixture was developed to interface the single chip packages to conventional laboratory instrumentation for characterization of the packaged devices. The package and test fixture designs were both developed in a generic sense, optimizing performance for a wide range of possible applications and devices.

Shalkhauser, K. A.↗

High-performance packaging for monolithic microwave and millimeter-wave integrated circuits

Packaging schemes are developed that provide low-loss, hermetic enclosure for enhanced monolithic microwave and millimeter-wave integrated circuits. These package schemes are based on a fused quartz substrate material offering improved RF performance through 44 GHz. The small size and weight of the packages make them useful for a number of applications, including phased array antenna systems. As part of the packaging effort, a test fixture was developed to interface the single chip packages to conventional laboratory instrumentation for characterization of the packaged devices.

Shalkhauser, K. A.↗

Correlation-based technique for automated tunable diode laser scan stabilization

A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.

May, Randy D.↗

Multiple-User, Multitasking, Virtual-Memory Computer System

Computer system designed and programmed to serve multiple users in research laboratory. Provides for computer control and monitoring of laboratory instruments, acquisition and anlaysis of data from those instruments, and interaction with users via remote terminals. System provides fast access to shared central processing units and associated large (from megabytes to gigabytes) memories. Underlying concept of system also applicable to monitoring and control of industrial processes.

Generazio, Edward R.↗

A DTA/GC for the in Situ Identification of the Martian Surface Material

The composition and mineralogy of the Martian surface material remain largely unknown. To determine its composition and mineralogy, several techniques are being considered for in situ analyses of the Martian surface material during missions to Mars. We have successfully developed, constructed, and tested a laboratory DTA/GC. The DTA is a Dupont model 1600 high temperature DTA coupled with a GC equipped with a MID detector. The system is operated by a Sun Sparc 11 workstation. When gas evolves during a thermal chemical event, it is shunted into the GC and the temperature is recorded in association with the specific thermal event. We have used this laboratory instrument to define experimental criteria necessary for determining the composition and mineralogy of the Martian surface in situ (e.g., heating of sample to 1100 C to distinguish clays). Our studies indicate that DTA/GC will provide a broad spectrum of mineralogical and evolved gas data pertinent to exobiology, geochemistry, and geology.

Mancinelli, R. L.↗

Radiation safety in aircraft operations

Data from a 7-yr flight experiment program to measure the significant biological components (tissue ionization rates, neutron flux, and nuclear reaction star rates) as a function of solar cycle, altitude, latitude and longitude from which biological risk from radiation is estimated are used to evaluate radiation dose and dose equivalents along specific flight trajectories. The data base used and the corresponding time-dependent global model are described. Ionization rates in air measured by argon filled chambers at solar minimum and maximum, and radiation measurements of the Brookhaven National Laboratory instrument compared to the present model are illustrated in tabular form. The global pressure distribution for solstice conditions at 14 km is shown.

Wilson, J. W.↗

A Method for the Instantaneous Determination of the Velocity and Direction of the Wind

The laboratory instruments, which we often constructed with makeshift means, gave encouraging results and showed that they could satisfactorily meet the required conditions. By limiting ourselves to the employment of hot wires of 0.05 mm (0.002 in.) diameter, we obtained instruments which faithfully followed all the wind fluctuations of over 0.1 second and even much more rapid variations without any very great error.

INSTRUMENTS - ANEMOMETERS↗

Adjustable Optical-Fiber Attenuator

Adjustable fiber-optic attenuator utilizes bending loss to reduce strength of light transmitted along it. Attenuator functions without introducing measurable back-reflection or insertion loss. Relatively insensitive to vibration and changes in temperature. Potential applications include cable television, telephone networks, other signal-distribution networks, and laboratory instrumentation.

Buzzetti, Mike F.↗