Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An analysis of water in galactic infrared sources using the NASA Lear Airborne Observatory

The Michelson interferometer system on the NASA Lear Jet Airborne Observatory is described as well as the data reduction procedures. The objects observed (standard stars, M stars, a nebula, planets, and the moon) are discussed and the observing parameters are listed for each flight date. The spectra obtained from these data flights are presented, grouped by class of object.

Smith, L. L.↗

Holographic interferometry and tomography at Ames Research Center

A YAG laser holographic interferometer system and reconstruction laboratory for the Ames 2- by 2-Foot Transonic Wind Tunnel are discussed. This system provides dual plate and double pulse holography for quantitative and qualitative measurements, respectively. Interferometric measurements of two-dimensional airfoils and three-dimensional bodies of revolution for a tomography feasibility study were made. The two-dimensional work included supercritical airfoils, an oscillating airfoil undergoing dynamic stall, and a circulation control airfoil. The tomography experiments centered around hemispherical nose and tangent ogive models. In addition, the tomography work covered the development of a Fourier transform code for the retrieval of the three dimensional density distributions from the interferograms.

Lee, G.↗

Stratospheric NO and NO2 profiles at sunset from analysis of high-resolution balloon-borne infrared solar absorption spectra obtained at 33 deg N and calculations with a time-dependent photochemical model

Simultaneous stratospheric vertical profiles of NO and NO2 at sunset were derived from an analysis of infrared solar absorption spectra recorded from a float altitude of 33 km with an interferometer system during a balloon flight. A nonlinear least squares procedure was used to analyze the spectral data in regions of absorption by NO and NO2 lines. Normalized factors, determined from calculations of time dependent altitude profiles with a detailed photochemical model, were included in the onion peeling analysis to correct for the rapid diurnal changes in NO and NO2 concentrations with time near sunset. The CO2 profile was also derived from the analysis and is reported.

Rinsland, C. P.↗

Stratospheric temperature profile from balloon-borne measurements of the 10.4-micron band of CO2

The technique of nonlinear least squares spectral curve fitting has been used to derive the stratospheric vertical temperature profile from balloon-borne measurements of the 10.4 micron band of CO2. The spectral data were obtained at sunset with the approximately 0.02 per cm resolution University of Denver interferometer system from a float altitude of 33.5 km near Alamogordo, New Mexico, on 23 March 1981. The r.m.s. deviation between the retrieved temperature profile and correlative radiosonde measurements is 2.2 K.

Rinsland, C. P.↗

Feasibility study of optical boundary layer transition detection method

A high sensitivity differential interferometer was developed to locate the region where the boundary layer flow undergoes transition from laminar to turbulent. Two laboratory experimental configurations were used to evaluate the performance of the interferometer: open shear layer, and low speed wind tunnel turbulent spot configuration. In each experiment, small temperature fluctuations were introduced as the signal source. Simultaneous cold wire measurements were compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations in the order of 0.001 the laser wavelength. An attempt to detect boundary layer transition over a flat plate at NASA-Langley Unitary Supersonic Wind Tunnel using the interferometer system was performed. The phase variations during boundary layer transition in the supersonic wind tunnel were beyond the minimum signal-to-noise level of the instrument.

Azzazy, M.↗

Upper limits for stratospheric H2O2 and HOCl from high resolution balloon-borne infrared solar absorption spectra

Solar absorption spectra from two stratospheric balloon flights have been analyzed for the presence of H2O2 and HOCl absorption in the 1230.0 to 1255.0 per cm region. The data were recorded at 0.02 per cm resolution during sunset with the University of Denver interferometer system on October 27, 1978 and March 23, 1981. Selected spectral regions were analyzed with the technique of nonlinear least squares spectral curve fitting. Upper limits of 0.33 ppbv for H2O2 and 0.36 ppbv for HOCl near 28 km are derived from the 1978 flight data while upper limits of 0.44 ppbv for H2O2 and 0.43 ppbv for HOCl at 29.5 km are obtained from the 1981 flight data.

Larsen, J. C.↗

Optical boundary-layer transition detection in a transonic wind tunnel

A high-sensitivity interferometer has been developed and used to detect boundary-layer transitions over a symmetric airfoil. The tests, which included both natural and roughness-induced transitions, were performed in a transonic wind tunnel. The measurements showed a peak amplitude rms and higher energy in the spectrum of the signal associated with transition. The tests revealed that the interferometer system can be used to locate the transition region over three-dimensional aerodynamic models.

Azzazy, M.↗

New spectral features of stratospheric trace gases

A new Michelson-type interferometer system operating in the infrared at very high resolution (0.002 to 0.003 wavenumber FWHM) was used to record numerous balloon-borne solar absorption spectra of the stratosphere, ground-based solar absorption spectra, and laboratory spectra of molecules of atmospheric interest. Results obtained are reported for several important stratospheric trace gases, HNO3, ClONO2, HO2NO2, NO2, and COF2, in the 8 to 12 micron spectral region. Many features of these gases were identified in the stratospheric spectra. Comparison of the spectra with line-by-line simulations shows previous spectral parameters are often inadequate. New analysis of high resolution laboratory and atmospheric spectra and improved theoretical calculations will be required for all bands. Preliminary versions of several sets of improved line parameters are presented.

Goldman, A.↗

New spectral features of stratospheric trace gases identified from high-resolution infrared balloon-borne and laboratory spectra

A new Michelson-type interferometer system operating in the infrared at very high resolution has been used to record numerous balloon-borne solar absorption spectra of the stratosphere, ground-based solar absorption spectra, and laboratory spectra of molecules of atmospheric interest. In the present work results obtained for several important stratospheric trace gases, HNO3, CIONO2, HO2NO2, NO2, and COF2, in the 8- to 12-micron spectral region are reported. Many new features of these gases have been identified in the stratospheric spectra. Comparison of the new spectra with line-by-line simulations shows that previous spectral line parameters are often inadequate and that new analysis of high-resolution laboratory and atmospheric spectra and improved theoretical calculations will be required for many bands. Preliminary versions of several sets of improved line parameters under development are discussed.

Goldman, A.↗

Explosive component acceptance tester using laser interferometer technology

Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

Wickstrom, Richard D.↗

Mach 10 bow-shock behavior of a forward-facing nose cavity

A detailed description of the bow-shock behavior associated with a conical-walled cavity with a flat circular base at M(infinity) = 10 is presented. An experimental test was performed on this configuration, and measurements of shock-oscillation frequency and amplitude, as well as shock shape, were recorded by a number of techniques. A laser-interferometer system was used for the first time during this test to determine bow-shock oscillation frequency in a nonintrusive manner. The primary behavior was a stable, periodically oscillating bow shock. Attention is also given to a violent bow-shock instability.

Huebner, Lawrence D.↗

Characterization of the dimensional stability of advanced metallic materials using an optical test bench structure

The dimensional stability of low-density high specific-strength metal-matrix composites (including 30 vol pct SiC(p)/SXA 24-T6 Al, 25 vol pct SiC(p)/6061-T6 Al, 40 vol pct graphite P100 fiber/6061 Al, 50 vol pct graphite P100 fiber/6061 Al, and 40 vol pct P100 graphite fiber/AZ91D Mg composites) and an Al-Li-Mg metal alloy was evaluated using a specially designed five-strut optical test bench structure. The structure had 30 thermocouple locations, one retroreflector, one linear interferometer multilayer insulation, and various strip heaters. It was placed in a 10 exp -7 torr capability vacuum chamber with a laser head positioned at a window port, and a laser interferometer system for collecting dimensional change data. It was found that composite materials have greater 40-C temporal dimensional stability than the AL-Li-Mg alloy. Aluminum-based composites demonstrated better 40-C temporal stability than Mg-based composites.

Hsieh, Cheng↗

Grazing Incidence Optics for X-rays Interferometry

Grazing incidence mirror parameters and constraints for x-ray interferometry are described. We present interferometer system tolerances and ray trace results used to define mirror surface accuracy requirements. Mirror material, surface figure, roughness, and geometry are evaluated based on analysis results. We also discuss mirror mount design constraints, finite element analysis, environmental issues, and solutions. Challenges associated with quantifying high accuracy mirror surface quality are addressed and test results are compared with theoretical predictions.

Shipley, Ann↗

Pulsed Plasma Thruster Plume Study: Symmetry and Impact on Spacecraft Surfaces

Twenty-four witness plates were positioned on perpendicular arrays near a breadboard Pulsed Plasma Thruster (PPT) to collect plume constituents for analysis. Over one million shots were fired during the experiment at 43 J using fluorocarbon polymer propellant. The asymmetry of the film deposition on the witness plates was investigated with mass and thickness measurements and correlated with off-axis thrust vector measurements. The composition of the films was determined. The transmittance and reflectance of the films were measured and the absorption coefficients were calculated in the wavelength range from 350 to 1200 mn. These data were applied to calculate the loss in signal intensity through the films, which will impact the visibility of spaceborne interferometer systems positioned by these thrusters.

Arrington, Lynn A.↗

4D PhaseCam(Trade Mark) Capabilities: Modal Analysis and Multiple-Wavelength Mirror Phasing

The PhaseCam is a dynamic phase shifting interferometer system manufactured by 4D Technology Corporation that is capable of very fast data acquisition. This rapid acquisition extends the capability of conventional interferometry to enable measurement in unstable environments, the generation of phase movies of surface shape and to facilitate modal analysis of structures. The PhaseCam hardware and software have been modified for MSFC to include synchronous modal optical measurement and analysis. These modifications will be discussed and data presented. The dynamic range of a phase shifting measurement is limited by local slope and pixel sampling to lambda/4 wave steps. Two-wavelength techniques can increase the effective measurement wavelength from microns to tens of centimeters and permit the phasing of mirror segments. A two wavelength PhaseCam will be discussed and measurement results presented.

Millerd, James E.↗

Precise Measurement for Manufacturing

A metrology instrument known as PhaseCam supports a wide range of applications, from testing large optics to controlling factory production processes. This dynamic interferometer system enables precise measurement of three-dimensional surfaces in the manufacturing industry, delivering speed and high-resolution accuracy in even the most challenging environments.Compact and reliable, PhaseCam enables users to make interferometric measurements right on the factory floor. The system can be configured for many different applications, including mirror phasing, vacuum/cryogenic testing, motion/modal analysis, and flow visualization.

Source record↗

Heterodyne Interferometer with a Phase Modulated Source

The present invention relates to a heterodyne interferometer system with a pre-processing of the target signal to isolate and remove self-interference signals using a known phase modulation of the carrier signal's frequency. Where self- interference signals do not include a time delay inherent in the target signal that travels to the target reflector, by selecting a modulation frequency tuned to the time delay and then filtering the resultant signal the target beam can be isolated and the self-interference signal can be effectively removed The system includes a modulation unit to apply a phase modulation to the carrier signal, and a mixing unit that demodulates the target signal at the modulation frequency to isolate the target beam.

Serge Dubovitsky↗

Silicon Detector Studies with an Interferometric Thickness Mapper

Cosmic ray isotopic composition studies aboard satellites are normally based on energy detection measurements which require a precise knowledge of matter thickness particle penetration. A laser- interferometer system has been developed to precisely map the thick- ness variations of large-area silicon detectors. Design, operation, and the data processing to derive thickness maps is described.

Cosmic Rays Silicon Detectors Interferometry Satel↗