Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

White-light interferometry for early-stage metal oxide growth characterization

Oxidation of metals can provide a functional oxide film or an oxide layer that can lead to material degradation causing performance limiting concerns. Because of the technological and economic impacts of oxidation, understanding early-stage oxidation growth and its mechanisms is of high importance. Unfortunately, poor empirical data during early-stage oxidation has left our current understanding of oxidation incomplete and woefully inadequate. Measurement techniques previously used for oxidation kinetics characterization include microbalance, x-ray diffraction, Fourier-transform infrared spectroscopy, and spectroscopic ellipsometry. However, these techniques lack the necessary time-resolution or vertical resolution in addition to not providing any spatial data, which is essential to early-stage oxidation studies to understand both oxidation kinetics and mechanisms. Here, a novel rapid and surface-sensitive data collection technique that provides three-dimensional spatial data of a growing oxide layer with sub-nanometer thickness resolution using white-light interferometry has been developed. This technique will be the first technique capable of providing real-time spatial results of early-stage oxidation growth. The effectiveness of this characterization tool is shown by observing the early-stage oxidation kinetics and film cracking of uranium heated to 90 °C under 500 torr of pure O 2 . Initially a parabolic oxidation growth is observed. Once the oxide layer reaches ≈ 30 nm, the epitaxial stresses between the uranium substrate and oxide film layer causes localized cracking in addition to the observed transition of the parabolic growth rate to a linear growth rate. The results of the white-light interferometry are verified by glancing incidence x-ray diffraction.

47 OTHER INSTRUMENTATION↗

Not all pure entangled states are useful for sub-shot-noise interferometry

We investigate the connection between the shot-noise limit in linear interferometers and particle entanglement. In particular, we ask whether sub-shot-noise sensitivity can be reached with all pure entangled input states of N particles if they can be optimized with local operations. Results on the optimal local transformations allow us to show that for N=2 all pure entangled states can be made useful for sub-shot-noise interferometry while for N>2 this is not the case. We completely classify the useful entangled states available in a bosonic two-mode interferometer. We apply our results to several states, in particular to multiparticle singlet states and to cluster states. The latter turn out to be practically useless for sub-shot-noise interferometry. Our results are based on the Cramer-Rao bound and the Fisher information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heisenberg-limited interferometry with pair coherent states and parity measurements

After reviewing parity-measurement-based interferometry with twin Fock states, which allows for supersensitivity (Heisenberg limited) and super-resolution, we consider interferometry with two different superpositions of twin Fock states, namely, two-mode squeezed vacuum states and pair coherent states. This study is motivated by the experimental challenge of producing twin Fock states on opposite sides of a beam splitter. We find that input two-mode squeezed states, while allowing for Heisenberg-limited sensitivity, do not yield super-resolutions, whereas both are possible with input pair coherent states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sagnac interferometry as a probe to the commutation relation of a macroscopic quantum mirror

Single photon Sagnac interferometry as a probe to macroscopic quantum mechanics is considered at the theoretical level. For a freely moving macroscopic quantum mirror susceptible to radiation pressure force inside a Sagnac interferometer, a careful analysis of the input-output relation reveals that the particle spectrum readout at the bright and dark ports encode information concerning the noncommutativity of position and momentum of the macroscopic mirror. A feasible experimental scheme to probe the commutation relation of a macroscopic quantum mirror is outlined to explore the possible frontier between classical and quantum regimes. In the Appendix, the case of Michelson interferometry as a feasible probe is also sketched.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent population trapping in Raman-pulse atom interferometry

Raman pulse atom interferometry is an important modality for precision measurements of inertial forces and tests of fundamental physics. Typical Raman atom optics use two coherent laser fields applied at gigahertz-scale detunings from optical resonance, so that spontaneous emission produces a minor or negligible source of decoherence. An additional consequence of spontaneous emission is coherent population trapping (CPT). We show that CPT produces coherences and population differences which induce systematic effects in Raman pulse atom interferometers. We do not believe that CPT has been previously identified as an error mechanism in Raman pulse atom interferometry. We present an experimental characterization of CPT coherences and population differences induced in laser-cooled cesium atoms by application of Raman pulses at detunings near 1 GHz, commensurate with detunings used in several precision measurement experiments. We are not aware of previous demonstrations of CPT-induced population difference. We argue that CPT effects could induce phase shifts of several milliradians in magnitude for typical experimental parameters and stipulate that these errors can be suppressed by propagation direction reversal in Raman interferometer-based precision measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic interactions in precision interferometry using Bose-Einstein condensates

We present theoretical tools for predicting and reducing the effects of atomic interactions in Bose-Einstein condensate (BEC) interferometry experiments. To address mean-field shifts during free propagation, we derive a robust scaling solution that reduces the three-dimensional Gross-Pitaevskii equation to a set of three simple differential equations valid for any interaction strength. To model the other common components of a BEC interferometer--condensate splitting, manipulation, and recombination--we generalize the slowly varying envelope reduction, providing both analytic handles and dramatically improved simulations. Applying these tools to a BEC interferometer to measure the fine structure constant, {alpha}[S. Gupta, K. Dieckmann, Z. Hadzibabic, and D. E. Pritchard, Phys. Rev. Lett. 89, 140401 (2002)], we find agreement with the results of the original experiment and demonstrate that atomic interactions do not preclude measurement to better than part-per-billion accuracy, even for atomic species with relatively large scattering lengths. These tools help make BEC interferometry a viable choice for a broad class of precision measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry

X-ray Talbot interferometry has been widely used as a technique for x-ray phase imaging and tomography. We propose a method using this interferometry for mapping distribution of parameters characterizing anisotropic microstructures, which are typically of the order of {mu}m in size and cannot be resolved by the imaging system, in a sample. The method uses reduction in fringe visibility, which is caused by such unresolvable microstructures, in moire images obtained using an interferometer. We applied the method to a chloroprene rubber sponge sample, which exhibited uniaxial anisotropy of reduced visibility. We measured the dependencies of reduced visibility on both the Talbot order and the orientation of the sample and obtained maps of three parameters and their anisotropies that characterize the unresolvable anisotropic microstructures in the sample. The maps indicated that the anisotropy of the sample's visibility contrast mainly originated from the anisotropy of the microstructure elements' average size. Our method directly provides structural information on unresolvable microstructures in real space, which is only accessible through the ultra-small-angle x-ray scattering measurements in reciprocal space, and is expected to be broadly applied to material, biological, and medical sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photon Hanbury-Brown-Twiss interferometry for noncentral heavy-ion collisions

Currently, the only known way to obtain experimental information about the space-time structure of a heavy-ion collision is through two-particle momentum correlations. Azimuthally sensitive Hanbury-Brown-Twiss (HBT) intensity interferometry can complement elliptic flow measurements by constraining the spatial deformation of the source and its time evolution. Performing these measurements on photons allows us to access the fireball evolution at earlier times than with hadrons. Using ideal hydrodynamics to model the space-time evolution of the collision fireball, we explore theoretically various aspects of two-photon intensity interferometry with transverse momenta up to 2 GeV, in particular the azimuthal angle dependence of the HBT radii in noncentral collisions. We highlight the dual nature of thermal photon emission, in both central and noncentral collisions, resulting from the superposition of QGP and hadron resonance gas photon production. This signature is present in both the thermal photon source function and the HBT radii extracted from Gaussian fits of the two-photon correlation function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring type Ia supernova angular-diameter distances with intensity interferometry

This paper investigates the potential of intensity interferometry, based on the Hanbury Brown-Twiss effect, for measuring supernova sizes and distances. With optimized telescope positioning, observing strategy, and advancements in single-photon detection technology, this method can provide precise angular size measurements of supernovae with apparent magnitudes as bright as 12 mag. For type Ia supernovae, this limiting brightness corresponds to a local volume extending to redshift z∼0.004 and an anticipated discovery rate of approximately 1 event per year. The combination of angular size data with known physical dimensions enables accurate distance determination. Multiple telescope pairs at different relative positions allow tomographic mapping of the ejecta structure while reducing distance uncertainties. As type Ia supernovae serve as standardizable candles for measuring the Universe’s expansion history, combining intensity interferometry distances with the supernova Hubble diagram facilitates measurements of the Hubble constant H0.

cosmological parameters↗

Experimental demonstration of a displacement noise free interferometry scheme for gravitational wave detectors showing displacement noise reduction at low frequencies

This paper reports an experimental demonstration of partial displacement noise free laser interferometry in the gravitational wave detection band. The used detuned Fabry-Perot cavity allows the isolation of the mimicked gravitational wave signal from the displacement noise on the cavities input mirror. By properly combining the reflected and transmitted signals from the cavity a reduction of the displacement noise was achieved. Our results represent the first experimental demonstration of this recently proposed displacement noise free laser interferometry scheme. Overall, we show that the rejection ratio of the displacement noise to the gravitational wave signal was improved in the frequency range of 10 Hz to 10 kHz with a typical factor of {approx}60.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Realization of Decoherence-Free Subspace in Neutron Interferometry

A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Protein–ligand interactions investigated by thermal shift assays (TSA) and dual polarization interferometry (DPI)

The biophysical characterization of protein–ligand interactions in solution using techniques such as thermal shift assay, or on surfaces using, for example, dual polarization interferometry, plays an increasingly important role in complementing crystal structure determinations. Over the last decades, a wide range of biophysical techniques investigating protein–ligand interactions have become indispensable tools to complement high-resolution crystal structure determinations. Current approaches in solution range from high-throughput-capable methods such as thermal shift assays (TSA) to highly accurate techniques including microscale thermophoresis (MST) and isothermal titration calorimetry (ITC) that can provide a full thermodynamic description of binding events. Surface-based methods such as surface plasmon resonance (SPR) and dual polarization interferometry (DPI) allow real-time measurements and can provide kinetic parameters as well as binding constants. DPI provides additional spatial information about the binding event. Here, an account is presented of new developments and recent applications of TSA and DPI connected to crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiple-wavelength digital holographic interferometry using tunable laser diodes

Here we present multiple-wavelength digital holographic interferometry with a wide measurement range using laser diodes. Small wavelength differences can be easily realized by the wavelength tuning of laser diodes with injection current controls. A contour map of an object with a wide measurement range and a high sensitivity is demonstrated by combining a few contour maps with several measurement sensitivities. Synthetic wavelengths are calibrated using a known height difference. This alleviates the need to have high precise knowledge of the recording wavelengths. The synthetic wavelengths ranged from {approx}3 mm for high measurement sensitivity to {approx}4 cm for wide measurement range. An rms error of {approx}35 {mu}m for a {approx}1 cm height measurement is shown. The measured profile of holographic interferometry agrees with a standard stylus instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of longitudinal displacement using lateral shearing cyclic path optical configuration setup and phase shifting interferometry

We present a technique for the measurement of longitudinal displacement using a lateral shearing cyclic path optical configuration (CPOC) setup and phase shifting interferometry. In the technique, a plane mirror mounted on a linear translation stage, placed slightly away from the focal plane of a lens, introduces a longitudinal focal shift to the incident focusing beam. The resulting spherical wavefront emerging from the lens is sheared into two orthogonally polarized beams using the CPOC setup. By applying polarization phase shifting interferometry (PPSI), the longitudinal focal shift of the beam focus is calculated by determining the slope of the optical path difference variation between the sheared beams. Similarly, the additional focal shift introduced due to longitudinal translation of the mirror, by an unknown amount, is determined using PPSI. Half of the difference between the two longitudinal focal shifts measured gives the longitudinal displacement of the mirror. The technique can be used for an extended range of distance measurement. The novelty of the technique is the introduction of CPOC for the distance measurement. The advantages of the technique compared to other related methods are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Disk Physical Conditions of 48 Persei Constrained by Contemporaneous Hα Spectroscopy and Interferometry

We utilize a multi-step modeling process to produce synthetic interferometric and spectroscopic observables, which are then compared to their observed counterparts. Our extensive set of interferometric observations of the Be star 48 Per, totaling 291 data points, were obtained at the Navy Precision Optical Interferometer from 2006 November 07 to 23. Our models were further constrained by comparison with contemporaneous Hα line spectroscopy obtained at the John S. Hall Telescope at the Lowell Observatory on 2006 November 1. Theoretical spectral energy distributions, SEDs, for 48 Per were confirmed by comparison with observations over a wavelength regime of 0.4–60 μm from Touhami et al. and Vieira et al. Our best-fitting combined model from Hα spectroscopy, Hα interferometry, and SED fitting has a power-law density fall off, n, of 2.3 and an initial density at the stellar surface of ρ{sub 0}=1.0×10{sup −11} g cm{sup −3} with an inclination constrained by Hα spectroscopy and interferometry of 45{sup ∘}±5{sup ∘}. The position angle for the system, measured east from north, is 114° ± 18°. Our best-fit model shows that the disk emission originates in a moderately large disk with a radius of 25 R {sub *}, which is consistent with a disk mass of approximately 5 × 10{sup 24} g or 3 × 10{sup −10} M {sub *}. Finally, we compare our results with previous studies of 48 Per by Quirrenbach et al. and find agreement, whereas our disk size does not agree with Delaa et al., based on a much smaller visibility set.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of systematic errors in lateral shearing interferometry for EUV optical testing

Lateral shearing interferometry (LSI) provides a simple means for characterizing the aberrations in optical systems at EUV wavelengths. In LSI, the test wavefront is incident on a low-frequency grating which causes the resulting diffracted orders to interfere on the CCD. Due to its simple experimental setup and high photon efficiency, LSI is an attractive alternative to point diffraction interferometry and other methods that require spatially filtering the wavefront through small pinholes which notoriously suffer from low contrast fringes and improper alignment. In order to demonstrate that LSI can be accurate and robust enough to meet industry standards, analytic models are presented to study the effects of unwanted grating and detector tilt on the system aberrations, and a method for identifying and correcting for these errors in alignment is proposed. The models are subsequently verified by numerical simulation. Finally, an analysis is performed of how errors in the identification and correction of grating and detector misalignment propagate to errors in fringe analysis.

36 MATERIALS SCIENCE↗

Coda-wave interferometry analysis of time-lapse VSP data for monitoring geological carbon sequestration

Injection and movement/saturation of carbon dioxide (CO2) in a geological formation will cause changes in seismic velocities. We investigate the capability of coda-wave interferometry technique for estimating CO2-induced seismic velocity changes using time-lapse synthetic vertical seismic profiling (VSP) data and the field VSP datasets acquired for monitoring injected CO2 in a brine aquifer in Texas, USA. Synthetic VSP data are calculated using a finite-difference elastic-wave equation scheme and a layered model based on the elastic Marmousi model. A possible leakage scenario is simulated by introducing seismic velocity changes in a layer above the CO2 injection layer. We find that the leakage can be detected by the detection of a difference in seismograms recorded after the injection compared to those recorded before the injection at an earlier time in the seismogram than would be expected if there was no leakage. The absolute values of estimated mean velocity changes, from both synthetic and field VSP data, increase significantly for receiver positions approaching the top of a CO2 reservoir. Our results from field data suggest that the velocity changes caused by CO2 injection could be more than 10% and are consistent with results from a crosswell tomogram study. This study demonstrates that time-lapse VSP with coda-wave interferometry analysis can reliably and effectively monitor geological carbon sequestration.

54 ENVIRONMENTAL SCIENCES↗