Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION EXCHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

FY25 Ion Exchange Processing for the West Area Risk Management (WARM) Project

The West Area Risk Management (WARM) Project was established to enable near-term retrieval and pretreatment of tank waste from Hanford’s 200 West Area and to support deployment of an ion exchange (IX) system capable of producing cesium-depleted supernate suitable for offsite treatment and disposal. The WARM experimental campaign was designed to provide key data for design and operational planning of the 200 W IX system, which plans to utilize crystalline silicotitanate (CST) as the active media for cesium removal. This report documents a comprehensive FY25 experimental campaign designed to produce key technical data required for design and operational planning of the WARM IX system. Testing includes assessing Cs and Sr breakthrough performance in a 4-column system, Cs capacity batch contact testing, phosphate precipitation assessments, reduced-hydroxide feed displacement evaluation, and Sr speciation impacts on Sr removal. The experimental results provide detailed trends in Cs and Sr loading behavior, breakthrough performance across a 4-column staged IX system, distribution profiles within CST beds, and projections of operational flowrates relative to Waste Acceptance Criteria (WAC) limits. Batch contact testing established equilibrium partitioning behavior for the S1–S5 simulants and characterized how matrix chemistry influenced Cs sorption onto CST. Additionally, further evaluations on waste matrix as it pertains to precipitation potential were also determined. Collectively, these datasets support engineering design choices for WARM system throughput and pretreatment planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adsorption Equilibrium, Kinetics, and Column Breakthrough Data of Acetic Acid, Butyric Acid, and Lactic Acid on IRN-78 Ion-exchange Resin at Initial pH ~3 – 7 and Temperature 25 – 55 °C

This work presents systematic aqueous-phase adsorption equilibrium, kinetics, and column breakthrough measurements with three key biointermediates that are common compounds in many bioprocesses. Adsorption equilibrium experiments were carried out with acetic acid, butyric acid, and lactic acid on a commercial ion-exchange resin, Amberlite IRN-78, at wide ranges of acid concentration (8-500 mmol/L), initial pH (similar to 3-7), and temperature (25-55 degrees C), simulating the effluent characteristics from different fermenter operations. The kinetics and column breakthrough experiments were conducted at an initial pH of 6 and a concentration of 200 mmol/L. The equilibrium study shows a higher loading at the initial pH < pK(a) and a lower loading at the initial pH > pK(a). Overall removal varies between 16 and 99% depending on the initial pH, temperature, and organic acid concentration and type. The study further indicates monolayer adsorption at the equilibrium pH > 10 and multilayer adsorption at the equilibrium pH < 6. The thermodynamic modeling of adsorption isotherm data was carried out using Langmuir and Freundlich isotherms. IRN-78 presents fast adsorption kinetics as the maximum loading was attained in <= 10 min and nearly the same breakthrough time for all three organic acids involved in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ether Cleavage Decreases the Ion Exchange Capacity of Anion Exchange Membranes

Anion exchange membranes (AEMs) are integral to fuel cells and water electrolysis systems but suffer from poor durability under alkaline conditions. Ether cleavage is an important failure pathway of poly(arylene ether)-based AEMs that compromises both mechanical stability and ion transport. While this degradation pathway is often studied in terms of polymer fragmentation, the role of newly formed hydrophilic groups has been largely overlooked. Here, we show that polymer scission leads to reduced mechanical rigidity, while the introduction of hydrophilic groups partially mitigates this loss. Under alkaline conditions, phenoxide groups formed during ether cleavage neutralize the polymer cations, leading to a previously unreported loss of ion exchange capacity (IEC). This IEC loss mechanism exacerbates the reduction in ionic conductivity, emphasizing the severity of ether cleavage as a degradation pathway. Recognizing that ether cleavage introduces significant chemical changes beyond polymer fragmentation provides critical insights into its interplay with other degradation mechanisms, such as the direct reduction of cationic sites by E2 and S N 2, and provides molecular-level interpretations for the concurrent effects of polymer scission and increased hydrophilicity on membrane performance.

crystal cleavage↗

Mechanism of Lithium Ion Exchange Into Spinel Manganese Oxide

Lithium manganese oxide (LMO) is an effective absorbent for lithium recovery from brines, characterized by its high adsorption capacity, excellent regeneration performance, and selectivity. Here, this study investigates the mechanisms of material degradation during lithium loading and unloading in LMO, employing a combination of time‐resolved Raman spectroscopy, X‐ray diffraction, and X‐ray photoelectron spectroscopy. Key findings reveal that the A 1g vibrational mode wavenumber shifts from 635 cm −1 at the onset of lithium ion exchange to 656 cm −1 after 12 min, indicating local symmetry loss and manganese (Mn) loss during lithium intercalation. The proposed lithium exchange mechanism involves initial occupation of tetrahedral interstitial voids, followed by migration into interstitial sites between Mn octahedral sites. Computational modeling suggests that the loss of symmetry in MnO cubane‐like groups occurs as lithium migrates, significantly affecting the Raman spectra. Importantly, the study demonstrates that after 100 cycles of lithium/hydrogen loading, a 24% loss in Mn is observed, which correlates with decreased structural stability; however, the structural integrity of LMO is enhanced when subjected to multiple cycles without complete loading. Here, these insights contribute to the understanding of LMO's performance in lithium recovery applications and highlight potential strategies to optimize its use in future technologies.

15 GEOTHERMAL ENERGY↗

Evaluation and Certification of Ambersorb 4652 for use in Activated Carbon Ion Exchange Filters for the International Space Station

In order to reduce the infiltration of dimethylsilanediol (DMSD) and other organosilicon containing species through the Multifiltration Beds (MF Beds), an alternate activated carbon was found to replace the obsolete Barnabey Cheney 580-26 activated carbon. The carbon that removed the most organosilicon compounds in testing1 was a synthetic activated carbon named Schunk 4652 which later became Ambersorb 4652. Since activated carbon has a large capacity for iodine (I2), and is used in the Activated Carbon Ion Exchange (ACTEX) filters on the International Space Station (ISS), testing was performed on the Ambersorb 4652 carbon to determine the effectiveness of the material for use in ACTEX filters to remove iodine. This work summarizes the testing and the certification of Ambersorb 4652 for use in the ACTEX filters for the ISS.

Adam, Niklas↗

Adsorption Equilibrium, Kinetics, and Column Breakthrough Data for Aqueous Solutions of Binary-Acid and Ternary-Acid Mixtures of Acetic Acid, Butyric Acid, and Lactic Acid on IRN-78 Ion-Exchange Resin at Initial pH Levels of ∼3–7 and at 25–55 °C

This work is part of an effort to develop thermophysical property data and models supporting adsorptive process development for organic acid separation from a dilute aqueous solution of fermentation broth. It presents systematic experimental measurements for aqueous-phase adsorption equilibrium, kinetics, and column breakthrough for three binary-acid aqueous mixtures (acetic acid + lactic acid, butyric acid + lactic acid, and acetic acid + butyric acid) and one ternary-acid aqueous mixture (acetic acid + butyric acid + lactic acid) on Amberlite IRN-78 ion-exchange resin. The equilibrium measurements covered broad ranges of the initial acid concentration (100–400 mmol/L), initial pH (∼3–7), and temperature (25–55 °C). The equilibrium data for the binary-acid and ternary-acid aqueous mixtures indicate selective adsorption of lactic acid at initial pH levels of ∼3 and 4, while acetic acid and butyric acid are selectively adsorbed at initial pH levels of 5, 6, and 7. The subsequent kinetics and column breakthrough experiments were performed at 200 mmol/L with equimolar ratios, an initial pH of 6, and 25 °C. In conclusion, the measurements provide essential data sets for rigorous thermodynamic modeling and process simulation of adsorptive separation processes for organic acid separation from fermentation broth.

Adsorption↗

Ion-Exchange Membrane-Centric Durability Testing and Degradation Characterization for Industry-Relevant CO 2 Reduction

Electrochemical CO 2 reduction is a promising conversion process for producing value-added fuels and chemicals from electricity and CO 2 as a sustainable carbon feedstock to domestically produce fuels and chemicals from industrial waste. Having reached industrially viable performance metrics with small-scale CO 2 electrolysis cells, the field must now increasingly focus on extending the device durability of large stacks to achieve equivalent metrics for 35,000+ hours to decrease maintenance and capital costs. Reported device lifetimes have increased in recent years, with the longest stability studies for CO, ethylene, and formic acid production being published in 2024–2025 with operation times of 4500, 1000, and 5200 h, respectively. Unfortunately, significant extension of the device durability is still required. Here, we provide an overview of ion-exchange membranes (IEMs) and provide insight into the variety of degradation mechanisms that must be overcome to enable the community to meet durability targets. In an effort to accelerate the extension of device lifetimes, we propose a general approach for characterizing CO 2 electrolysis cell degradation before and after durability testing to better elucidate the mechanisms and failure modes of IEMs in zero-gap cells. Furthermore, we encourage the adoption of operando characterizations in tandem with accelerated stress and durability tests, postulating that their combined applications will be increasingly valuable. We hope that this perspective motivates future durability studies to evaluate degradation across the entire electrolysis cell.

09 BIOMASS FUELS↗

Critical role of polymer-ceramic ion exchange for high conductivity composite electrolytes

Polymer-ceramic composites offer a path to enhance the transport and mechanical properties of solid electrolytes. However, an in-depth understanding of the extent and role of ion transport along and across polymer-ceramic interfaces in these systems is lacking. We have recently shown that Li-conducting Li 0.11 Na 0.24 K 0.02 La 0.43 TiO 2.82 (LMTO) nanorods can be prepared by a molten flux method, and the addition of 30–50 weight (wt.)% LMTO to a bis[(trifluoromethyl)sulfonyl]imide-vinyl ethylene carbonate-based single-ion conducting (SIC) polymer electrolyte leads to a two-fold enhancement in Li-ion conductivity, from 1.4 to 3.0 × 10 −5 S/cm at 30 °C. In the present study, we use NMR methods to identify the Li-ion transport pathways and determine the timescale of chemical exchange between the SIC polymer and LMTO ceramic components. Tracer exchange NMR indicates preferential transport through the polymer or polymer-interfacial regions, and exchange spectroscopy (EXSY) and a new isotope exchange method reveal negligible Li exchange between the SIC polymer and LMTO ceramic up to several days. Here, LMTO nanorods act as a passive filler. Our results further highlight that significant (e.g., 10- or 100-fold) conductivity enhancements in composite electrolytes can only be achieved 1) with ionically-conductive fillers, and 2) when both the ceramic and polymer components actively participate in long-range transport. For this, fast interfacial ion exchange is needed. In conclusion, this leads us to introduce a critical interfacial ion exchange time to evaluate whether a filler actively contributes to conduction in a composite electrolyte, and screen for promising polymer-ceramic pairings to accelerate the development of high conductivity solid electrolytes.

Battery, Solid electrolyte↗

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion exchange selectivity for cross-linked polyacrylic acid

The ion separation factors for 21 common metal ions with cross-linked polyacrylic acid were determined as a function of pH and the percent of the cross-linked polyacrylic acid neutralized. The calcium ion was used as a reference. At a pH of 5 the decreasing order of affinity of the ions for the cross-linked polyacrylic acid was found to be: Hg++, Fe+++, Pb++, Cr+++, Cu++, Cd++, Al+++, Ag+, Zn++, Ni++, Mn++, Co++, Ca++, Sr++, Ba++, Mg++, K+, Rb+, Cs+, Na+, and Li+. Members of a chemical family exhibited similar selectivities. The Hg++ ion appeared to be about a million times more strongly bound than the alkali metal ions. The relative binding of most of the metal ions varied with pH; the very tightly and very weakly bound ions showed the largest variations with pH. The calcium ion-hydrogen ion equilibrium was perturbed very little by the presence of the other ions. The separation factors and selectivity coefficients are discussed in terms of equilibrium and thermodynamic significance.

May, C. E.↗

Ion-exchange chromatography separates activities synthesizing and degrading fructose 2,6-bisphosphate from C3 and C4 leaves but not from rat liver

Fructose-6-phosphate,2-kinase and fructose-2,6-bisphosphatase were separated on the basis of charge from leaves of C3 (spinach, lettuce, and pea) and C4 (sorghum and amaranthus) plants but not from rat liver--a tissue known to contain a bifunctional enzyme with both activities. [2-32P]Fructose 2,6-bisphosphate binding experiments also suggest that the major forms of these activities reside on different proteins in leaves.

NASA Discipline Exobiology↗

Channel waveguides in glass via silver-sodium field-assisted ion exchange

Multimode channel waveguides have been formed in sodium aluminosilicate glass by field-assisted diffusion of Ag(+) ions from vacuum-evaporated Ag films. The two-dimensional refractive index profiles of the waveguides were controlled by varying the diffusion time, the diffusion temperature, and the electric field strength. Estimates of the diffusion rate through a strip aperture were obtained, assuming the electric field was strong 120-240 V/mm. The maximum change in refractive index in the sodium aluminosilicate glasses was estimated near 65 percent of the change in soda-lime silicate glass. The physical properties of the glasses are given in a table.

Forrest, K.↗