Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

Structure and magnetic properties of irradiated Fe/Fe oxide core-shell nanoclusters

A cluster deposition method was used to produce a film of loosely aggregated particles of Fe-Fe3O4 core-shell nanoclusters with an 8 nm iron core size and 2 nm oxide shell thickness. The film of particles on a silicon substrate was irradiated with 5.5 MeV Si2+ ions to a fluence of 1016 cm-2 near room temperature, and computer simulations based on the SRIM (Stopping and Range of Ions in Matter) code show that the implanted Si species stops near the film-substrate interface. The ion irradiation creates a structural change in the film with corresponding chemical and magnetic changes. X-ray diffraction shows that the core size and chemistry stay the same but the shell becomes FeO that grows to a thickness of 17 nm. Helium ion microscopy shows that the previously separate particles have densified into a nearly continuous film. Major loop magnetic hysteresis measurements show a decrease in saturation magnetization that we attribute to the presence of the antiferromagnetic (AFM) FeO shell. First-order reversal curve measurements on the irradiated film performed with a vibrating sample magnetometer show that the AFM shell prevents the particles from interacting magnetically, leading to low coercivity from the iron core and little bias field from the core interactions. These results, and others reported previously on different compositions (Fe3O4 or FeO+Fe3N nanoclusters), show that the ion irradiation behavior of nanocluster films such as these depends strongly on the initial nanostructure and chemistry.

Environmental Molecular Sciences Laboratory↗

Key mechanistic features of swelling and blistering of helium-ion-irradiated tungsten

In this study, helium-ion-induced swelling and blistering of single-crystal tungsten is investigated using a Helium Ion Microscope for site-specific dose-controlled irradiation (at 25 keV) with analysis by Helium Ion Microscopy, Atomic Force Microscopy and Transmission Electron Microscopy (cross-sectioning by Focused Ion Beam milling). We show that the blister cavity forms at a depth close to the simulated helium peak and that nanobubbles coalesce to form nanocracks within the envelope of the ion stopping range, swelling the blister shell. These results provide the first direct experimental evidence for the interbubble fracture mechanism proposed in the framework of the gas pressure model for blister formation.

36 MATERIALS SCIENCE↗

High-efficiency single-junction p-i-n GaAs solar cell on roll-to-roll epi-ready flexible metal foils for low-cost photovoltaics

We demonstrate the fabrication and characterization of high-efficiency, single-junction p-i-n GaAs solar cells, on flexible metal foil with epi-ready buffer via roll-to-roll fabrication. Single-junction p-i-n GaAs solar cells were fabricated using metal–organic chemical vapor deposition (MOCVD). Furthermore, an efficiency greater than 13% was obtained at 1 sun, which is the highest reported efficiency on GaAs photovoltaics directly deposited on metal tapes. This exceeds our previously reported study showcasing 11.5% efficiency on single-junction p-n solar cell structure. Improved morphology of p-i-n structure compared with p-n is explained by atomic force microscopy (AFM), scanning electron microscopy (SEM), and helium ion microscopy (HIM) measurements. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis showed reduced Zn diffusion in p-i-n cell compared with the p-n cell. We attribute the improvement in efficiency of p-i-n cells on flexible metal tapes to the quality of the junction, surface morphology, controlled diffusion of species within the active layers, and increase in absorption due to the optimized intrinsic layer thickness.

14 SOLAR ENERGY↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Surface science analysis of GaAs photocathodes following sustained electron beam delivery

Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power Free Electron Lasers (FEL). Photocathode quantum efficiency (QE) degradation is due to residual gasses in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes, which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include Helium Ion Microscopy (HIM), Rutherford Backscattering Spectrometry (RBS), Atomic Force Microscopy (AFM) and Secondary Ion Mass Spectrometry (SIMS). In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the Continuous Electron Beam Accelerator Facility (CEBAF) photoinjector and one unused, were also analyzed using Transmission Electron Microscopy (TEM) and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but shows evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.

36 MATERIALS SCIENCE↗

Metal-dielectric interactions

Metal direlectric surface interactions and dielectric films on metal substrates were investigated. Since interfacial interaction depends so heavily on the nature of the surfaces, analytical surface tools such as Auger emission spectroscopy, X-ray photoelectron spectroscopy and field ion microscopy were used to assist in surface and interfacial characterization. The results indicate that with metals contacting certain glasses in the clean state interfacial, bonding produces fractures in the glasses while when a film such as water is present, fractures occur in the metal near the interface. Friction forces were used to measure the interfacial bond strengths. Studies with metals contacting polymers using field ion microscopy revealed that strong bonding forces could develop being between a metal and polymer surface with polymer transferring to the metal surface in various ways depending upon the forces applied to the surface in contact. With the deposition of refractory carbides, silicides and borides onto metal and alloy substrates the presence of oxides at the interface or active gases in the deposition plasma were shown to alter interfacial properties and chemistry. Auger ion depth profile analysis indicated the chemical composition at the interface and this could be related to the mechanical, friction, and wear behavior of the coating.

Buckley, D. H.↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Oxygen Adsorption, Subsurface Oxygen Layer Formation and Reaction with Hydrogen on Surfaces of a Pt–Rh Alloy Nanocrystal

The oxygen adsorption and its catalytic reaction with hydrogen on Pt–Rh single crystals were studied at the nanoscale by Field Emission Microscopy (FEM) and Field Ion Microscopy (FIM) techniques at 700 K. Both FEM and FIM use samples prepared as sharp tips, apexes of which mimic a single nanoparticle of catalyst considering their similar size and morphology. Oxygen adsorption on Pt-17.4 at.%Rh samples leads to the formation of subsurface oxygen, which is manifested in the field emission (FE) patterns: for O2 exposure of ~3 Langmuir (L), {113} planes appear bright in the emission pattern, while for higher oxygen doses, i.e. 84 L, the bright regions correspond to the high index planes between the {012} and {011} planes. Formation of subsurface oxygen is probably accompanied by a surface reconstruction of the nanocrystal. The subsurface oxygen can be effectively reacted off by subsequent exposure of the sample to hydrogen gas at 700 K. The hydrogenation reaction was observed as a sudden, eruptive change of the brightness seen on the FE pattern. This reaction resulted in the recovery of the initial field emission pattern characteristic of a clean tip, with {012} facets being the most visible. It was shown that the oxygen accumulation-reduction process is completely reversible. The obtained results indicate that the presence of subsurface species must be considered in the description of reactive processes on Pt–Rh catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Resolution Multimodal Chemical Imaging Platform for Organics and Inorganics

Chemical analysis at the nanoscale is critical to advance our understanding of materials and systems from medicine and biology to material science and computing. Macroscale-observed phenomena in these systems are in the large part driven by processes that take place at the nanoscale and are highly heterogeneous. Therefore, there is a clear need to develop a new technology that enables correlative imaging of material functionalities with nanoscale spatial and chemical resolutions that will enable us to untangle the structure–function relationship of functional materials. As such, here, we report on the analytical figures of merit of the newly developed correlative chemical imaging technique of helium ion microscopy coupled with secondary ion mass spectrometry (HIM-SIMS) that enables multimodal topographical/chemical imaging of organic and inorganic materials at the nanoscale. In HIM-SIMS, a focused ion beam acts as a sputtering and ionization source for chemical analysis along with simultaneous high-resolution surface imaging, providing an unprecedented level of spatial resolution for gathering chemical information on organic and inorganic materials. In this work, we demonstrate HIM-SIMS as a platform for a next-generation tool for an in situ material design and analysis capable of down to 8 nm spatial resolution chemical imaging, layered metal structure imaging in depth profiling, single graphene layer detection, and spectral analysis of metals, metal oxides, and polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment

With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulations of secondary electron emission due to ion beam milling

We present a Monte Carlo simulation study of secondary electron emission resulting from focused ion beam milling of a copper target. The basis of this study is a simulation code which simulates ion induced excitation and emission of secondary electrons, in addition to simulating focused ion beam sputtering and milling. This combination of features permits the simulation of the interaction between secondary electron emission, and the evolving target geometry as the ion beam sputters material. Previous ion induced SE Monte Carlo simulation methods have been restricted to predefined target geometries, while the dynamic target in the presented simulations makes this study relevant to image formation in ion microscopy, and chemically assisted ion beam etching, where the relationship between sputtering, and its effects on secondary electron emission, is important. We focus on a copper target, and validate our simulation against experimental data for a range of: noble gas ions, ion energies, ion/substrate angles and the energy distribution of the secondary electrons. We then provide a detailed account of the emission of secondary electrons resulting from ion beam milling; we quantify both the evolution of the yield as high aspect ratio valleys are milled, as well as the emission of electrons within these valleys that do not escape the target, but which are important to the secondary electron contribution to chemically assisted ion induced etching.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Refined tip preparation by electrochemical etching and ultrahigh vacuum treatment to obtain atomically sharp tips for scanning tunneling microscope and atomic force microscope

A modification of the common electrochemical etching setup is presented. The described method reproducibly yields sharp tungsten tips for usage in the scanning tunneling microscope and tuning fork atomic force microscope. In situ treatment under ultrahigh vacuum (p {<=}10{sup -10} mbar) conditions for cleaning and fine sharpening with minimal blunting is described. The structure of the microscopic apex of these tips is atomically resolved with field ion microscopy and cross checked with field emission.

36 MATERIALS SCIENCE↗