Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ion beam probing of electrostatic fields

The determination of a cylindrically symmetric, time-independent electrostatic potential V in a magnetic field B with the same symmetry by measurements of the deflection of a primary beam of ions is analyzed and substantiated by examples. Special attention is given to the requirements on canonical angular momentum and total energy set by an arbitrary, nonmonotone V, to scaling laws obtained by normalization, and to the analogy with ionospheric sounding. The inversion procedure with the Abel analysis of an equivalent problem with a one-dimensional fictitious potential is used in a numerical experiment with application to the NASA Lewis Modified Penning Discharge. The determination of V from a study of secondary beams of ions with increased charge produced by hot plasma electrons is also analyzed, both from a general point of view and with application to the NASA Lewis SUMMA experiment. Simple formulas and geometrical constructions are given for the minimum energy necessary to reach the axis, the whole plasma, and any point in the magnetic field. The common, simplifying assumption that V is a small perturbation is critically and constructively analyzed; an iteration scheme for successively correcting the orbits and points of ionization for the electrostatic potential is suggested.

Persson, H.↗

Fluorinated Electrolytes for 5-V Li-Ion Chemistry: Probing Voltage Stability of Electrolytes with Electrochemical Floating Test

A series of electrolyte formulations containing fluorinated cyclic carbonates and fluorinated linear carbonates with LiPF6 has been evaluated as electrolyte solvents for high-voltage Li-ion batteries. The anodic stability of the new electrolytes on fully charged spinel LiNi0.5Mn1.5O4 (LNMO) cathode was examined by electrochemical floating tests. The effects of fluorine substitution on the cyclic and linear carbonate, ratio of cyclic vs. linear carbonate, and LiPF6 concentration on the electrolyte oxidation stability were investigated. Based on this study, the floating test proved to be an effective tool for identification of stable electrolyte materials.

5-V LiNi0.5Mn1.5O4 cathode↗

The early archaean crustal history of West Greenland as recorded by detrital zircons

The isotope systematics of some of the oldest samples on Earth from both Greenland and Australia was discussed. The antiquity was confirmed of the 4.1 to 4.2 Ga zircons from Western Australia; the model Lu-Hf age of these zircons, as measured with the ANU ion probe is 4.14 + or - 0.24 Ga, although the oldest preserved rock units there are anorthosites with a Lu-Hf model age of about 3.73 Ga. U-Pb ion probe ages of detrital zircons ranging between 2.87 and 3.89 Ga from an Akilia association quartzite was reported, whose age of deposition is probably around 3.8 Ga. It was argued that the younger age in this range are discordant because of late Pb-loss, probably associated with a high grade metamorphic event at about 3.6 Ga. It was also argued that the earliest crust in West Greenland and elsewhere is about 3.9 Ga, but in some places, such as Western Australia, crustal evolution took place much earlier, perhaps starting as far back as 4.3 Ga. This would account for the presence in that terrane of abundant K rich granitoid, the paucity of tonalitic and trondhjemitic materials, and the existence of Eu anomalies in early Archean sediments.

Kinny, P. D.↗

Simulations of the Ion Current to a Probe in Plasma with Allowance for Ionization and Ion–Neutral Collisions: II. Cylindrical Probe

The ion current to a cylindrical probe is considered with allowance for volume ionization, ion–neutral collisions, and the ion orbital moment. A model based on the molecular dynamics method and applicable in a wide range of plasma parameters (r{sub p}/λ{sub D}= 0.01–100, r{sub i}/λ{sub D}= 0.002–200, ν{sub i}/ω{sub 0i}= 0.01–0.05, and T{sub i}/T{sub e} = 0−0.01) is proposed A convenient representation of the dependence of the relative ion current density on the Langmuir coefficient β{sup 2} and a technique for determining the plasma density from simulation results are offered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The DCU laser ion source

Laser ion sources are used to generate and deliver highly charged ions of various masses and energies. We present details on the design and basic parameters of the DCU laser ion source (LIS). The theoretical aspects of a high voltage (HV) linear LIS are presented and the main issues surrounding laser-plasma formation, ion extraction and modeling of beam transport in relation to the operation of a LIS are detailed. A range of laser power densities (I{approx}10{sup 8}-10{sup 11} W cm{sup -2}) and fluences (F=0.1-3.9 kJ cm{sup -2}) from a Q-switched ruby laser (full-width half-maximum pulse duration {approx}35 ns, {lambda}=694 nm) were used to generate a copper plasma. In ''basic operating mode,'' laser generated plasma ions are electrostatically accelerated using a dc HV bias (5-18 kV). A traditional einzel electrostatic lens system is utilized to transport and collimate the extracted ion beam for detection via a Faraday cup. Peak currents of up to I{approx}600 {mu}A for Cu{sup +} to Cu{sup 3+} ions were recorded. The maximum collected charge reached 94 pC (Cu{sup 2+}). Hydrodynamic simulations and ion probe diagnostics were used to study the plasma plume within the extraction gap. The system measured performance and electrodynamic simulations indicated that the use of a short field-free (L=48 mm) region results in rapid expansion of the injected ion beam in the drift tube. This severely limits the efficiency of the electrostatic lens system and consequently the sources performance. Simulations of ion beam dynamics in a ''continuous einzel array'' were performed and experimentally verified to counter the strong space-charge force present in the ion beam which results from plasma extraction close to the target surface. Ion beam acceleration and injection thus occur at ''high pressure.'' In ''enhanced operating mode,'' peak currents of 3.26 mA (Cu{sup 2+}) were recorded. The collected currents of more highly charged ions (Cu{sup 4+}-Cu{sup 6+}) increased considerably in this mode of operation.

43 PARTICLE ACCELERATORS↗

Recognizing the Effects of Terrestrial Contamination on D/H Ratios in Shergottite Phosphates

Hydrogen isotope ratios in shergottite phosphate minerals have been investigated by SIMS in the meteorites Queen Alexandra Range (QUE) 94201 and Los Angeles. We have also collected electron probe data on these phosphates in order to characterize the phosphate minerals and attempt to document any potential hydrogen isotopic differences between chlor-apatite and whitlockite. In the section of Los Angeles we studied (748), we found both chlor-apatite and whitlockite, but in the section of QUE 94201,38 studied, we found only whitlockite. In both meteorites, D/H ratios (expressed in units of delta D (sub SMOW) vary, from terrestrial values up to approximately 5400%o in QUE 94201, and to approximately 3800%o in Los Angeles. We have carefully examined the ion probed pits with high-resolution FE-SEM. In most cases where the D/H ratios are low, we have iden-tified cracks that instersect the ion probe pit. These cracks are not visible in the optical microscope attached to the SIMS instument, making them impossible to avoid during SIMS data collection. We contend that the low ratios are a function of substantial terrestrial contamination, and that similar contamination is a likely factor in previously published studies on D/H ratios in martian phosphates. Here we highlight the difficulty of attempts to constrain the martian mantle D/H ratio using phosphate data, given that both terrestrial contamination and martian mantle hydrogen will move phosphate D/H ratios in the same direction, toward lower values. We note that our data include some of the most deuterium-rich values ever reported for martian phosphates. It is clear that some of our measurements are only minimally or totally uncontaminated, but the question arises, are intermediate values diminished because of true martian variability, or do they reflect contamination?

Ross, D. K.↗

Multidiagnostic analysis of ultrafast laser ablation of metals with pulse pair irradiation

Copper targets are irradiated in the ablation regime by pairs of equal, time-delayed collinear laser pulses separated on a timescale going from {approx_equal}2 ps to {approx_equal}2 ns. The ablation plume is characterized by ion probe diagnostic, fast imaging, and temporally and spatially resolved optical emission spectroscopy. The variation in the ablation efficiency with the delay between the pulses is analyzed by measuring the ablation crater profile with a contact profilometer. The second laser pulse modifies the characteristics of the plasma plume produced by the first pulse and the ablation efficiency. The different mechanisms involved in double pulse ultrafast laser ablation are identified and discussed. The experimental findings are interpreted in the frame of a simple model of the interaction of the second pulse with the nascent ablation plume produced by the first pulse. This model yields consistent and quantitative agreement with the experimental findings predicting the observed experimental trends of the ablation depth reduction and ion yield increase with the delay between the pulses, as well as the characteristic timescale of the observed changes. The possibility of controlling the characteristics of the plumes produced during ultrafast laser ablation via an efficient coupling of the energy of the second pulse to the various ablation components produced by the first pulse is of particular interest in ultrafast pulsed laser deposition and microprobe analyses of materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗

Tomographic study of ion tracks by ion energy loss spectroscopy

Ion energy loss spectroscopy is suggested to determine the shape of the (latent, etched and filled) ion tracks in polymers using ion probes of various beam sizes. For a milli-probe, it can be considered as a one-dimensional tomography of many identical (rotationally symmetric) objects. For a micro-probe, the technique can be understood as a micro-tomography of the single ion track. In both cases, the ion energy loss spectroscopy requires monoenergetic ions with a low intensity (< 10{sup -3} s{sup -1}) and a well defined angular beam set-up. Here we present a study of the possible use of the ion milli-and micro-probes in a tomographic study of the ion track 3D geometry and its evolution during chemical etching.

36 MATERIALS SCIENCE↗

Z-Pinch Discharge in Laser Produced Plasma

A fast coaxial electrical discharge, with relatively low current, was used to produce a Z-pinch effect in a laser produced aluminum plasma. The ion flux in the laser plasma was monitored with a Langmuir ion probe. The line density in the plasma column was controlled by using an aperture to select the portion of the laser plasma which enters the discharge cell. The Z-pinch dynamics were recorded using time-resolved imaging of the visible self-emission; the plasma was pinched to about one-third of the initial radius. Both the laser and Z-pinch plasmas were diagnosed using time-and space-resolved spectroscopy; substantial heating was observed. The measured behaviour of the pinch was compared with predictions of the slug model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Perovskite Nanoparticles as Halide Reservoirs in Catalysis and as Spectrochemical Probes of Ions in Solution

The ability of cesium lead halide (CsPbX 3 ; X = Cl – , Br – , I – ) perovskite nanoparticles (P-NPs) to participate in halide exchange reactions, to catalyze Finkelstein organohalide substitution reactions, and to colorimetrically monitor chemical reactions and detect anions in real time is described. With the use of tetraoctylammonium halide salts as a starting point, halide exchange with the P-NPs was performed to calibrate reactivity, stability, and extent of ion exchange. Also, the exchange of CsPbI 3 with Cl – or Br – causes a significant blue-shift in absorption and photoluminescence, whereas reacting I – with CsPbBr 3 causes a red-shift of similar magnitudes. With the high local halide concentrations and the facile nature of halide exchange in mind, we then explored the ability of P-NPs to catalyze organohalide exchange in Finkelstein like reactions. Results indicate that the P-NPs serve as excellent halide reservoirs for substitution of organohalides in nonpolar media, leading to not only different organohalide products, but also a complementary color change over the course of the reaction, which can be used to monitor kinetics in a precise manner. Finally, the merits of using P-NP as spectrochemical probes for real time assaying is then expanded to other anions which can react with, or result in unique, classes of perovskites.

36 MATERIALS SCIENCE↗

SIMS chemical analysis of extended impacts on the leading and trailing edges of LDEF experiment AO187-2

The Long Duration Exposure Facility (LDEF) Experiment AO187-2 consisted of 237 capture cells, 120 on the leading edge and 117 on the trailing edge. Each cell was made of polished Ge plates covered with 2.5 micron thick mylar foil at 200 microns from the Ge. Although all leading edge cells and 105 trailing edge cells had lost their plastic covers during flight, optical and electron microscope examination revealed extended impacts in bare cells from either edge that apparently were produced by high velocity projectiles while the plastic foils were still in place. Detailed optical scanning yielded 53 extended impacts on 100 bare cells from the trailing edge that were selected for SIMS chemical analysis. Lateral multi-element ion probe profiles were obtained on 40 of these impacts. Material that can be attributed to the incoming projectiles was found in all analyzed extended compact features and most seem to be associated with cosmic dust particles. However, LDEF deposits are systematically enriched in the refractory elements Al, Ca, and Ti relative to Mg and Fe when compared to IDP's collected in the stratosphere and to chondritic compositions. These differences are most likely due to elemental fractionation effects during the high velocity impact but real differences between interplanetary particles captured on LDEF and stratospheric IDP's cannot be excluded. Recently we extended our studies to cells from the leading edge and the covered cells from the trailing edge. The 12 covered cells contain 20 extended impact candidates. Ion probe analysis of 3 yielded results similar to those obtained for impacts on the bare cells from the trailing edge. Optical scanning of the bare leading edge cell also reveals many extended impacts (42 on 22 cells scanned to date), demonstrating that the cover foils remained intact at least for some time. However, SIMS analysis showed elements that can reasonably be attributed to micrometeoroids in only 2 out of 11 impacts. Eight impacts have residues dominated by Al and one dominated by Ti, indicating a preponderance of orbital debris in leading edge impacts.

Amari, S.↗

Spatially resolved chemical imaging of individual atmospheric particles using nanoscale imaging mass spectrometry: Insighs into particle origin and chemistry

Knowledge of the spatially-resolved composition of atmospheric particles is essential for differentiating between their surface versus bulk chemistry, understanding particle reactivity and the potential environmental impact. We demonstrate the application of nanometer-scale secondary ion mass spectrometry (Cameca NanoSIMS 50 ion probe) for 3D chemical imaging of individual atmospheric particles without any sample pre-treatment, such as the sectioning of particles. Use of NanoSIMS depth profile analysis enables elemental mapping of particles with nanometer spatial resolution over a broad of range of particle sizes. We have used this technique to probe spatially resolved composition of ambient particles collected during a field campaign in Mexico City. Particles collected during this campaign have been extensively characterized in the past using other particle analysis techniques and hence offer a unique opportunity for exploring the utility of depth resolved chemical imaging in ambient particle research. 1 Particles examined in this study include those collected during a pollution episode related to urban waste incineration as well as background particles from the same location prior to the episode. Particles from the pollution episode show substantial intra-particle compositional variability typical of particles resulting from multiple emission sources. In contrast, the background particles have relatively homogeneous compositions with enhanced presence of nitrogen, oxygen and chlorine at the particle surface. The observed surface enhancement of nitrogen and oxygen species is consistent with the presence of surface nitrates resulting from gas-particle heterogeneous interactions and is indicative of atmospheric ageing of the particles. The results presented here illustrate 3D characterization of ambient particles for insights into their chemical history.

Environmental Molecular Sciences Laboratory↗

In Situ Probing of Ion Ordering at an Electrified Ionic Liquid/Au Interface

Charge transport at the interface of electrodes and ionic liquids is critical for the use of the latter as electrolytes. In this study, a room-temperature ionic liquid, 1-ethyl-2,3-dimethylimidazolium bis(trifluoromethanesulfonyl)imide (EMMIM TFSI), is investigated in situ under applied bias voltage with a novel method using low-energy electron and photoemission electron microscopy. Changes in photoelectron yield as a function of bias applied to electrodes provide a direct measure of the dynamics of ion reconfiguration and electrostatic responses of the EMMIM TFSI. Finally, long-range and correlated ionic reconfigurations that occur near the electrodes are found to be a function of temperature and thickness, which, in turn, relate to ionic mobility and different configurations for out-of-plane ordering near the electrode interfaces, with a critical transition in ion mobility for films thicker than three monolayers.

36 MATERIALS SCIENCE↗

Probing specific ion effects at air-aqueous dibutyl phosphate interfaces using vibrational sum frequency generation spectroscopy

Molecular properties at air–liquid and liquid–liquid interface hold the key to many processes involving molecular transport across phase boundaries from aerosol formation to carbon cycling and material separation using solvent extraction techniques. Using dibutyl phosphate (DBP) as a representative for partially aqueous soluble surfactants, the specific ion effect (SIE) of the Hofmeister series cations Cs + , Na + , Li + , and Mg 2+ on the partition and interaction between surfactant molecules and water molecules in the air–aqueous interface are investigated using vibrational sum frequency generation spectroscopy and surface tension measurements. In the presence of 1 mM and 1M bulk aqueous phase ionic strength salt concentrations, fundamental qualitative relationships are observed for the salting out of DBP relative to bulk aqueous phase nitrate salt concentrations and the specific cations species. At 1 mM ionic strength, the interfacial charge and hence the interfacial potential modulates the electrostatic interactions; in particular, the counter cations partially screen the negatively charged interface induced by the DBP in a direct Hofmeister order. At 1M ionic strength, the electric field at the interface or interfacial potential is effectively neutralized, and the counter cations promote the partitioning of DBP to the interface depending on their specific interaction with the DBP head group and metal ion hydration properties. The present results lay a foundation to study SIEs of heavier metals on hydrophobic-aqueous DBP interfaces.

Louie, Christina [Washington State University, Pul↗