Methods and approaches to dosimetry

The development of a dosimetric system capable of determining energy depositions in tissue regions that are smaller than a few 100 nanometers is projected. These objectives are met by evaluation of the data produced by a macro-subsystem and a micro-subsystem. Both systems are in essence multiple ionization chambers that are normally operated in a gated pulse mode. The macro-system yields absorbed radiation dose as a function of location in a phantom of the human trunk when it operates in the dose mode; it registers only those sections as a signal in which the primary particle or any of its secondaries have passed, in the pulse mode. The function of the micro-system is to provide detailed information of the track structure by determining lateral energy spread due to delta ray formation or other secondary particle production.

Rossi, H. H.

Dose and linear energy transfer spectral measurements for the supersonic transport program

The purpose of the package, called the high altitude radiation instrumentation system (HARIS), is to measure the radiation hazard to supersonic transport passengers from solar and galactic cosmic rays. The HARIS includes gaseous linear energy transfer spectrometer, a tissue equivalent ionization chamber, and a geiger meuller tube. The HARIS is flown on RB-57F aircraft at 60,000 feet. Data from the HARIS are reduced to give rad and rem dose rates measured by the package during the flights. Results presented include ambient data obtained on background flights, altitude comparison data, and solar flare data.

Philbrick, R. B.

Experimental active and passive dosimetry systems for the NASA Skylab program

Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

Schneider, M. F.

Calibration of radiation detectors in the ultraviolet region between 972 and 2500 A

The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better.

Mcclenahan, J. O.

A liquid xenon radioisotope camera.

A new type of gamma-ray camera is discussed that makes use of electron avalanches in liquid xenon and is currently under development. It is shown that such a radioisotope camera promises many advantages over any other existing gamma-ray cameras. Spatial resolution better than 1 mm and counting rates higher than one million C/sec are possible. An energy resolution of 11% FWHM has recently been achieved with a collimated Hg-203 source using a parallel-plate ionization chamber containing a Frisch grid.

Zaklad, H.

Calculation of energy deposition distributions for simple geometries

When high-energy charged particles pass through a thin detector, the ionization energy loss in that detector is subject to fluctuations or straggling which must be considered in interpreting the data. Under many conditions, which depend upon the charge and energy of the incident particle and the detector geometry, the ionization energy lost by the particle is significantly different from the energy deposited in the detector. This problem divides naturally into a calculation of the energy loss that results in excitation and low-energy secondary electrons which do not travel far from their production points, and a calculation of energy loss that results in high-energy secondary electrons which can escape from the detector. The first calculation is performed using a modification of the Vavilov energy loss distribution. A cutoff energy is introduced above which all electrons are ignored and energy transferred to low energy particles is assumed to be equivalent to the energy deposited by them. For the second calculation, the trajectory of the primary particle is considered as a source of secondary high-energy electrons. The electrons from this source are transported using Monte Carlo techniques and multiple scattering theory, and the energy deposited by them in the detector is calculated. The results of the two calculations are then combined to predict the energy deposition distribution. The results of these calculations are used to predict the charge resolution of parallel-plate pulse ionization chambers that are being designed to measure the charge spectrum of heavy nuclei in the galactic cosmic-ray flux.

Watts, J. W., Jr.

Isotopic composition of heavy cosmic rays

The mean isotopic composition was measured of even-charge cosmic ray elements with 14 equal to or less than 26 near 0.8 GeV/N using a balloon-borne ionization-chamber/Cerenkov-counter detector system. The experimental method makes use of the geomagnetic field as a magnetic spectrometer. Results indicate that the most abundant isotopes at the cosmic ray source are Si-28, S-32, and Ca-40, like the solar system; but Fe-54, unlike the solar system.

Maehl, R. C.

Absolute photon-flux measurements in the vacuum ultraviolet

Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

Samson, J. A. R.

Mean isotopic composition of cosmic rays with 12 less than Z less than or equal to 26 at 2.7 to 3.0 GV

Results are presented from a high-altitude balloon flight in September 1972 near 3-GV geomagnetic cutoff. The detector is a combination of ionization chambers and a Lucite Cerenkov counter with a charge resolution of 0.34 charge units. Following the technique described by Lund et al. (1971), use is made of the geomagnetic rigidity cutoff and measured momentum-per-nucleon spectra of individual elements to determine values of A/Z for even Z elements of 16 less than or equal to Z less than or equal to 26 relative to A/Z of silicon.

Maehl, R. C.

Energy spectra of individual cosmic-ray elements with 12 less than or equal to Z less than or equal to 28

Results are presented from a high-altitude balloon flight in September 1972 of a detector using ionization chambers and a Lucite Cerenkov counter. Relative abundances of elements of 14 less than or equal to Z less than or equal to 30 are presented, as are energy spectra for individual elements between 0.8 and 1.6 GeV/N. A difference between the low- and high-energy relative abundances of iron and iron-secondaries is found, as well as a sharp fall-off in the Fe/Si ratio below 1 GeV/N.

Israel, M. H.

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.

Radiation measuring instrumentation

Four radiation measuring instruments were developed. These are: (1) improved detector probe, (2) neutron spectrometer--dosimeter, (3) portable ultraviolet spectro-radiometer; and (4) pocket ionization chamber radiation dosimeter. A brief description of each of these devices is presented.

Piltingsrud, H. V.

Structure and dynamics of a solar flare - X-ray and XUV observations

Results are presented for an analysis of X-ray and XUV emission from the solar flare that occurred on September 5, 1973. X-ray emission was monitored by ionization chambers aboard the Solrad 9 satellite, and the XUV emission in the wavelength range 170-345 A was recorded by a slitless objective-grating spectroheliograph on Skylab. The physical parameters of the flare plasma, including temperature, density, volume, and magnetic-field configuration, are evaluated. A geometrical loop model is used to determine the volumes of the various emitting regions. The structure of the flare in the rise and decay phases is examined in detail, and conclusions about the effect of various dynamic processes in the flare plasma are made. A major finding is that continued energy release is required well into the flare decay phase. In the rise phase, energy is apparently released only along a small portion of a loop, and in the decay phase apparently throughout most of its length.

Dere, K. P.

The impact of gas-surface reactions on mass spectrometric measurements of atomic nitrogen

The paper presents a simplified model of the ion source chemistry, explains several details of the data reduction method used in obtaining atomic-nitrogen (N) densities from OSS data, and discusses implications of gas-surface reactions for the design of future satellite-borne mass spectrometers. Because of various surface reactions, N appears in three different forms in the ion source, as N, NO, and NO2. Considering the rather small spin modulation of NO and NO2 in the semi-open ionization chamber used in the OSS instrument, it is not surprising that these reaction products have not been previously identified in closed source instruments as a measure of the presence of atomic nitrogen. Warmup and/or outgassing of the ion source are shown to drastically reduce the NO2 concentration, thereby making possible reliable measurement of ambient N densities.

Engebretson, M. J.

Photoabsorption cross sections of CH3F, CHF3, CH3Cl, and CF2Cl2 from 175 to 760 A

The study of fluorinated and chlorinated hydrocarbons is of great interest because of their suspected effect on the ozone layer in the atmosphere. Using synchrotron radiation as a continuum background, the present study measures photoelectrically the photoabsorption cross sections of CH3F, CHF3, CH3Cl, and CF2Cl2 in the 175-760 A (70.8-16.3 eV) region, using a double ionization chamber. The absolute absorption cross sections and a tentative interpretation of the observed discrete structures are presented.

Wu, C. Y. R.

Study of sulfur-containing molecules in the EUV region. I - Photoabsorption cross section of SO2

Using synchrotron radiation as a continuum background, the absorption cross sections of SO2 have been measured using a double ionization chamber. The cross sections range from 10 to a maximum value of 56 Mb in the 175-760 A region. A possible window resonance series was observed and tentatively assigned to a Ryberg series converging to the (6a sub 1) to the -1st ion state. From the fluorescence excitation function the vibrational progressions of the SO2(+) ion states have been measured and found in good agreement with those observed from photoelectron spectroscopy. The same correspondence between peaks in the fragment fluorescence excitation function and the photoelectron spectrum suggests that these ion states of SO2 are dissociative in nature.

Wu, C. Y. R.

The UH-nuclei cosmic ray detector on the third High Energy Astronomy Observatory

The third High Energy Astronomy Observatory satellite (HEAO-3) carries a particle telescope for the detection of highly charged cosmic ray nuclei. These nuclei, which have Z equal to or greater than 28, are much rarer than the lower charged nuclei in the cosmic radiation. As a consequence, this particle telescope was required to have a large collecting area as well as an ability to resolve individual elements. This paper describes the telescope, composed of large area parallel plate ionization chambers, multiwire ion chamber hodoscopes and a Cherenkov radiation detector. The resulting telescope has a total geometry factor of 59,000 sq cm sr and is capable of measuring the charges of nuclei in the range Z = 14-120.

Binns, W. R.