Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Deuterium retention in MeV ion-irradiated beryllium

Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.

36 MATERIALS SCIENCE↗

Advanced Test Reactor In-Canal Ultrasonic Scanner: Experiment Design and Initial Results on Irradiated Plates

An irradiation test device has been developed to support testing of prototypic scale plate type fuels in the Advanced Test Reactor. The experiment hardware and operating conditions were optimized to provide the irradiation conditions necessary to conduct performance and qualification tests on research reactor type fuels for the RERTR program. The device was designed to allow disassembly and reassembly in the ATR spent fuel canal so that interim inspections could be performed on the fuel plates. An ultrasonic scanner was developed to perform dimensional and transmission inspections during these interim investigations. Example results from the AFIP-2 experiment are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast Electron Dynamics in Gold in the Presence of Laser Excited Surface Plasma Waves

Surface plasmon excitation with ultrashort intense laser pulses enhances efficiently laser absorption in metals and creates local high fields and non-equilibrium hot electrons population that have attractivity for numerous applications such as the development of intense sources of high-energy particles or photons and in the fast ignitor scheme in the framework of inertial fusion. In this context, the knowledge of the dynamics of relaxation of the collective electrons behavior is of importance. Using gold grating, we have investigated electrons relaxation in the presence of laser excited surface plasmon waves using a multiple-wavelengh femtosecond pump-probe technique. The results yield evidence of longer relaxation time in the presence of the collective excitation than that of individual electronic states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric field and temperature effects in irradiated MOSFETs

Electronic devices exposed to ionizing radiation exhibit degradation on their electrical characteristics, which may compromise the functionality of the device. Understanding the physical phenomena responsible for radiation damage, which may be specific to a particular technology, it is of extreme importance to develop methods for testing and recovering the devices. The aim of this work is to check the influence of thermal annealing processes and electric field applied during irradiation of Metal Oxide Semiconductor Field Effect Transistors (MOSFET) in total ionizing dose experiments analyzing the changes in the electrical parameters in these devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of 3D diamond detectors for detector applications at ultra high luminosity facilities

During this project our group has succeeded in producing and measuring a number of 3D diamond devices. We have worked with manufacturers and shown that poly-crystalline CVD (pCVD) diamond can be grown reliably with a 5% uniformity in industry. We have produced 3D diamond devices and scaled up the production technology from roughly 100 cells on a device to 4000 cells on a device. We have increased the column yield from 92% to 99%. We have reduced the cell size from our safe initial choice 150μm x 150μm cells to the HL-LHC size of 50μm x 50μm cells. We have reduced the column diameter from 6-10 μm to 2.6 μm. In beam tests we have quantified the amount of charge each 3D device yields for minimizing ionizing particles and compared this to that produced by a planar diamond device. Very recently, we produced the first 3D diamond pixel devices read out with both ATLAS and CMS pixel electronics, tested them in particle beams at CERN and PSI. Finally we have successfully tested the first irradiated 3Ddiamond device after a fluence of 3.5 x 10 15 800 MeV p/cm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband enhancement of infrared absorption in microbolometers using Ag nanocrystals

High performance microbolometers are widely sought for thermal imaging applications. In order to increase the performance limits of microbolometers, the responsivity of the device to broadband infrared (IR) radiation needs to be improved. In this work, we report a simple, quick, and cost-effective approach to modestly enhance the broadband IR response of the device by evaporating Ag nanocrystals onto the light entrance surface of the device. When irradiated with IR light, strong fields are built up within the gaps between adjacent Ag nanocrystals. These fields resistively generate heat in the nanocrystals and underlying substrate, which is transduced into an electrical signal via a resistive sensing element in the device. Through this method, we are able to enhance the IR absorption over a broadband spectrum and improve the responsivity of the device by ∼11%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Atoms-to-devices models for post-irradiation annealing kinetics in III-V semiconductors

Understanding atomic displacement damage and propagating this understanding into validated defect-aware radiation damage models is a critical step toward achieving predictive, atoms-to-systems assessment of radiation vulnerabilities of microelectronics. These models are essential for evaluating the performance and reliability of nuclear stockpile components or space-based electronics (satellites). The goal of this project was to bridge a fundamental science gap between defect spectroscopies and atomistic modeling of radiation-induced defects on the one hand, and simulations of device response on the other hand, to develop predictive defect-aware damage models for high-fidelity device simulations of radiation-damaged III-V semiconductors.

36 MATERIALS SCIENCE↗

Influence of exposure to 980 nm laser radiation on the luminescence of Si:Er/O light-emitting diodes

Erbium (Er) codoping with oxygen (O) in Si is a well-known method for producing electroluminescent material radiating at 1.54 {mu}m through a 4f shell transition of Er{sup 3+} ions. In this work the influence of exposure to 980 nm radiation on the electroluminescence (EL) of reverse biased Si:Er/O light-emitting diodes (LEDs), which give a strong room temperature 1.54 {mu}m intensity, is presented and discussed. All the device layers, including Er/O doped Si sandwiched between two Si{sub 0.82}Ge{sub 0.18} layers, have been grown on silicon on insulator substrates using molecular beam epitaxy and processed to fabricate edge emitting Si:Er/O waveguide LEDs. Electromagnetic mode confinement simulations have been performed to optimize the layer parameters for waveguiding. The temperature dependence of the 1.54 {mu}m EL intensity exhibits an abnormal temperature quenching with a peak near -30 deg. C, and at -160 deg. C it has decreased by a factor of 5. However, irradiating the devices with a 980 nm laser gives an enhancement of the 1.54 {mu}m EL intensity, which is more dramatic at low temperatures (e.g., -200 deg. C) where the quenched EL signal is increased up to almost the same level as at room temperature. The enhancement of the EL intensity is attributed to the photocurrent generated by the 980 nm laser, reducing the detrimental avalanche current.

36 MATERIALS SCIENCE↗

Distinctive features of fluorescence and waveguides in magnesium aluminate spinel crystals driven by structural discrepancy

Transparent polycrystalline ceramics are of significant importance for a wide range of scientific and industrial applications. Developing a deeper understanding of their thermodynamic behavior is essential for achieving their maximum output performance in technological applications. This study provides a systematic investigation into the thermal excitation-induced fluorescence kinetics and waveguide characteristics of Magnesium Aluminate Spinel (MgAl 2 O 4 ) single crystals, with a focus on the intricate relationship between structure and properties. High-temperature extreme environments through irradiation with swift heavy ions 645.0 MeV Xe and 352.8 MeV Fe ions were created; the atomic deposition energy threshold (E th ) associated with disorder morphologies was assessed between 0.91 and 0.99 eV atom –1 . The track prediction model was developed to support the theoretical prediction of track formation. Electronic energy loss (E ele ) disrupts the balance of the initial structure through the thermal spike effect, leading to the formation of absorption-related F and F + color centers. These defects enhance photoluminescence in the visible spectrum and result in an effective modulation of the intrinsic bandgap. Moreover, as ion beams penetrate into the material, the uneven damage distribution induces the formation of waveguide structures. In conclusion, these findings provide valuable insights into the fabrication of functional devices through irradiation technologies and the structural changes of MgAl 2 O 4 at high temperatures within extreme environments.

36 MATERIALS SCIENCE↗

Effect of 100MeV oxygen ion irradiation on silicon NPN power transistor

The radiation response of npn Bipolar junction transistor (BJT) has been examined for 100 MeV O{sup 7+} ion. Key electrical properties like Gummel characteristics, dc current gain and capacitance-voltage of 100MeV O{sup 7+} ion irradiated transistor were studied before and after irradiation. The device was decapped and the electrical characterizations were performed at room temperature. Base current is observed to be more sensitive than collector current and gain appears to be degraded with ion fluence, also considerable degradation in C-V characteristics is observed and doping concentration is found to be increased along with the increase in ion fluence.

36 MATERIALS SCIENCE↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

Ultra-high Photoresponsivity in Suspended Metal-Semiconductor-Metal Mesoscopic Multilayer MoS 2 Broadband Detector from UV-to-IR with Low Schottky Barrier Contacts

The design, fabrication, and characterization of ultra-high responsivity photodetectors based on mesoscopic multilayer MoS 2 is presented, which is a less explored system compared to direct band gap monolayer MoS 2 that has received increasing attention in recent years. The device architecture is comprised of a metal-semiconductor-metal (MSM) photodetector, where Mo was used as the contact metal to suspended MoS 2 membranes. The photoresponsivity R was measured to be ~1.4 × 10 4 A/W, which is > 10 4 times higher compared to prior reports, while the detectivity D* was computed to be ~2.3 × 10 11 Jones at 300 K at an optical power P of ~14.5 pW and wavelength λ of ~700 nm. In addition, the dominant photocurrent mechanism was determined to be the photoconductive effect (PCE), while a contribution from the photogating effect was also noted from trap-states that yielded a wide spectral photoresponse from UV-to-IR (400 nm to 1100 nm) with an external quantum efficiency (EQE) ~10 4 . From time-resolved photocurrent measurements, a decay time τ d ~ 2.5 ms at 300 K was measured from the falling edge of the photogenerated waveform after irradiating the device with a stream of incoming ON/OFF white light pulses.

36 MATERIALS SCIENCE↗

Quantum Sensing of Insulator‐to‐Metal Transitions in a Mott Insulator

Nitrogen vacancy (NV) centers, optically active atomic defects in diamond, have attracted tremendous interest for quantum sensing, network, and computing applications due to their excellent quantum coherence and remarkable versatility in a real, ambient environment. Taking advantage of these strengths, this paper reports on NV-based local sensing of the electrically driven insulator-to-metal transition (IMT) in a proximal Mott insulator. The resistive switching properties of both pristine and ion-irradiated VO 2 thin film devices are studied by performing optically detected NV electron spin resonance measurements. These measurements probe the local temperature and magnetic field in electrically biased VO 2 devices, which are in agreement with the global transport measurement results. In pristine devices, the electrically driven IMT proceeds through Joule heating up to the transition temperature while in ion-irradiated devices, the transition occurs nonthermally, well below the transition temperature. Here, the results provide direct evidence for nonthermal electrically induced IMT in a Mott insulator, highlighting the significant opportunities offered by NV quantum sensors in exploring nanoscale thermal and electrical behaviors in Mott materials.

McLaughlin, Nathan J.↗

Sandia National Laboratories FY20 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY20 the Energetic Neutrons campaign increased the number and complexity of experiments, continued collaborations with external organizations, and generated knowledge that supports SNL’s National Security mission. In FY20 the Energetic Neutrons campaign was executed by an early career team led by a new PI. The SNL team members were trained to take over new responsibilities during the shot day to increase the number and complexity of experiments in the campaigns. Also, in FY20 for the first time the Energetic Neutrons campaign had a graduate student contributing with pre and post-irradiation characterizations at SNL of the semiconductor devices irradiated at OMEGA. In FY20 SNL collaborated with the Air Force Nuclear Weapons Center (AFNWC) and supported experiments related to radiation effects in semiconductor devices. SNL also gave the opportunity to ride along to Los Alamos National Laboratory and multiple scientists from MIT and LLE. SNL continued using the last two generations of the Neutron Effects Diagnostics (NEDs) to field active and passive experiments but also redesigned the latest generation of the NEDs to accommodate larger components and improve the vacuum sealing as shown in figure 1a. The redesigned NEDs allowed SNL to perform active tests of a high voltage (HV) PCB for the first time at OMEGA; where signals before, during and after the irradiation were recorded. The HV PCB installed in one of the SNL NEDs is shown in figure 1b where a 3D-printed nosecone was used to check for mechanical and electrical interference. Passive irradiations of multiple components were followed up with leakage current, gain measurements and radiation-induced defect characterization.

42 ENGINEERING↗

SU-E-T-55: A Novel Applicator for High Dose Rate Brachytherapy Treatments of Ocular Conjunctiva

Purpose: To evaluate the clinical feasibility of IntraBeam intra operative kV irradiation beam device for ocular conjunctiva treatments. The Intra-Beam system offers a 4.4 mm diameter needle applicator, that is not suitable for treatment of a large surface with limits access. We propose an adaptor that will answer to this clinical need and provide initial dosimetry. Methods: The dose distribution of the needle applicator is non uniform and hence not suitable for treatment of relatively large surfaces. We designed an adapter to the needle applicator that will filter the X-rays and produce a conformal dose distribution over the treatment area while shielding surfaces to be spared. Dose distributions were simulated using FLUKA is a fully integrated particle physics Monte Carlo simulation package. Results: We designed a wedge applicator made of Polythermide window and stainless steel for collimating. We compare the dose distribution to that of the known needle and surface applicators. Conclusion: Initial dosimetry shows feasibility of this approach. While further refinements to the design may be warranted, the results support construction of a prototype and confirmation of the Monte Carlo dosimetry with measured data.

60 APPLIED LIFE SCIENCES↗

Simple model of the indirect compression of targets under conditions close to the national ignition facility at an energy of 1.5 MJ

The possibility of the analysis and interpretation of the reported experiments with the megajoule National Ignition Facility (NIF) laser on the compression of capsules in indirect-irradiation targets by means of the one-dimensional RADIAN program in the spherical geometry has been studied. The problem of the energy balance in a target and the determination of the laser energy that should be used in the spherical model of the target has been considered. The results of action of pulses differing in energy and time profile (“low-foot” and “high-foot” regimes) have been analyzed. The parameters of the compression of targets with a high-density carbon ablator have been obtained. The results of the simulations are in satisfactory agreement with the measurements and correspond to the range of the observed parameters. The set of compared results can be expanded, in particular, for a more detailed determination of the parameters of a target near the maximum compression of the capsule. The physical foundation of the possibility of using the one-dimensional description is the necessity of the closeness of the last stage of the compression of the capsule to a one-dimensional process. The one-dimensional simulation of the compression of the capsule can be useful in establishing the boundary behind which two-dimensional and three-dimensional simulation should be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗