Soot Nanostructure: Using Fringe Analysis Software on High Resolution Transmission Electron Microscopy of Carbon Soot

Using high resolution transmission electron images of carbon nanotubes and carbon particles, we are able to use image analysis program to determine several carbon fringe properties, including length, separation, curvature and orientation. Results are shown in the form of histograms for each of those quantities. The combination of those measurements can give a better indication of the graphic structure within nanotubes and particles of carbon and can distinguish carbons based upon fringe properties. Carbon with longer, straighter and closer spaced fringes are considered graphite, while amorphous carbon contain shorter, less structured fringes.

King, James D.↗

Implementation of a Pulsed-Laser Measurement System in the National Transonic Facility

A remotely-adjustable laser transmission and imaging system has been developed for use in a high-pressure, cryogenic wind tunnel. Implementation in the National Transonic Facility has proven the system suitable for velocity and signal lifetime measurements over a range of operating conditions. The measurement system allows for the delivery of high-powered laser pulses through the outer pressure shell and into the test section interior from a mezzanine where the laser is free from environmental disturbances (such as vibrations and excessive condensation) associated with operation of the wind tunnel. Femtosecond laser electronic excitation tagging (FLEET) was utilized to provide freestream velocity measurements, and first results show typical data that may be obtained using the system herein described.

Reese, Daniel T.↗

TPSAS-NF1676L-31770-DND

HREBSD (high resolution electron backscatter diffraction) is a scanning electron microscope based diffraction technique that measures stress, elastic strain and dislocation density in crystalline materials with a spatial resolution on the order of tens of nanometers. This information represents a glut of quantitative data that may be directly incorporated in microscale crystal plasticity models. However, concerns over the accuracy of HREBSD make integration of microscopy data with material models problematic. This presentation addresses a number of issue concerning the accuracy of HREBSD, including pattern center error, cross-correlation error and random noise. Additionally, a computational framework is presented that allows for rapid, non-deterministic calibration of material models. Finally, several tests cases are presented where HREBSD is cross-validated with other diffraction techniques: X-ray diffraction, electron channeling contrast imaging and transmission electron microscopy. The accuracy of HREBSD, when incorporating these new techniques, is sufficient to measure local stress to below 10 MPa and to detect individual dislocations.

Timothy J Ruggles↗

Coded aperture imaging with uniformly redundant arrays

The paper discusses uniformly redundant arrays (URA) as applied to coded aperture imaging. The URA system offers the high-transmission characteristics of random arrays as well as a flat sidelobe advantage. The high-transmission yields the imaging of very low-intensity sources and the flat sidelobes provide the suppression of inherent noise which obscures low-contrast sources. Simulations have shown that the URA with shot and background noise produces a better reconstructed object than random arrays without shot or background noise. The URA also offers an arrangement which involves a mosaic of basic URA patterns forming a circular correlation of the object on the picture plane. Thus the information needed to reconstruct the object is contained in an area equal to that of the basic aperture pattern. This smaller required detector is important in applications including X-ray astronomy.

Fenimore, E. E.↗

Combining image-processing and image compression schemes

An investigation into the combining of image-processing schemes, specifically an image enhancement scheme, with existing compression schemes is discussed. Results are presented on the pyramid coding scheme, the subband coding scheme, and progressive transmission. Encouraging results are demonstrated for the combination of image enhancement and pyramid image coding schemes, especially at low bit rates. Adding the enhancement scheme to progressive image transmission allows enhanced visual perception at low resolutions. In addition, further progressing of the transmitted images, such as edge detection schemes, can gain from the added image resolution via the enhancement.

Greenspan, H.↗

FTIR Spectroscopic Characterization Of II-VI Semiconductors

Combination of commercial Fourier-transform infrared (FTIR) spectrometer with computer and special-purpose software constitutes highly automated facility for acquisition and processing of infrared transmission or reflection spectral image data. Intended principally to acquire transmission spectra of some compounds of elements in groups II and VI of periodic table. System used to characterize specimens of II/VI alloy semiconductors grown by directional solidification and quenching. Transmission-edge maps helpful in studies of flows, gradients of temperature, and coefficients of diffusion in solidifying melts. Data acquired by system include optical characteristics, and they both verify and complement data obtained by such other techniques as measurements of density and x-ray-dispersion analysis.

Perry, G. L. E.↗

Software Graphical User Interface For Analysis Of Images

CAMTOOL software provides graphical interface between Sun Microsystems workstation and Eikonix Model 1412 digitizing camera system. Camera scans and digitizes images, halftones, reflectives, transmissives, rigid or flexible flat material, or three-dimensional objects. Users digitize images and select from three destinations: work-station display screen, magnetic-tape drive, or hard disk. Written in C.

Leonard, Desiree M.↗

Digital compression algorithms for HDTV transmission

Digital compression of video images is a possible avenue for high definition television (HDTV) transmission. Compression needs to be optimized while picture quality remains high. Two techniques for compression the digital images are explained and comparisons are drawn between the human vision system and artificial compression techniques. Suggestions for improving compression algorithms through the use of neural and analog circuitry are given.

Adkins, Kenneth C.↗

Laser-enhanced synthesis and processing of diamond films from liquid hydrocarbons

We report synthesis of diamond films by pulsed laser irradiation on copper substrate immersed into liquid benzene. It is envisaged that carbon released from benzene at the liquid-solid interface is converted into diamond as a result of rapid quenching from a high temperature. The diamond crystallites were characterized using high resolution transmission electron microscopy imaging and electron diffraction techniques. Growth of thicker diamond films by subsequent chemical vapor deposition has been investigated by transmission and scanning electron microscopy techniques. Thin diamond film deposited during liquid phase provided seed for diamond growth during subsequent chemical vapor deposition.

Singh, Jogender↗

Potential end-to-end imaging information rate advantages of various alternative communication systems

Various communication systems were considered which are required to transmit both imaging and a typically error sensitive, class of data called general science/engineering (gse) over a Gaussian channel. The approach jointly treats the imaging and gse transmission problems, allowing comparisons of systems which include various channel coding and data compression alternatives. Actual system comparisons include an Advanced Imaging Communication System (AICS) which exhibits the rather significant potential advantages of sophisticated data compression coupled with powerful yet practical channel coding.

Rice, R. F.↗

End-to-end imaging information rate advantages of various alternative communication systems

The efficiency of various deep space communication systems which are required to transmit both imaging and a typically error sensitive class of data called general science and engineering (gse) are compared. The approach jointly treats the imaging and gse transmission problems, allowing comparisons of systems which include various channel coding and data compression alternatives. Actual system comparisons include an advanced imaging communication system (AICS) which exhibits the rather significant advantages of sophisticated data compression coupled with powerful yet practical channel coding. For example, under certain conditions the improved AICS efficiency could provide as much as two orders of magnitude increase in imaging information rate compared to a single channel uncoded, uncompressed system while maintaining the same gse data rate in both systems. Additional details describing AICS compression and coding concepts as well as efforts to apply them are provided in support of the system analysis.

Rice, R. F.↗

Real-time transmission of full-motion echocardiography over a high-speed data network: impact of data rate and network quality of service

With high-resolution network transmission required for telemedicine, education, and guided-image acquisition, the impact of errors and transmission rates on image quality needs evaluation. METHODS: We transmitted clinical echocardiograms from 2 National Aeronautics and Space Administration (NASA) research centers with the use of Motion Picture Expert Group-2 (MPEG-2) encoding and asynchronous transmission mode (ATM) network protocol over the NASA Research and Education Network. Data rates and network quality (cell losses [CLR], errors [CER], and delay variability [CVD]) were altered and image quality was judged. RESULTS: At speeds of 3 to 5 megabits per second (Mbps), digital images were superior to those on videotape; at 2 Mbps, images were equivalent. Increasing CLR caused occasional, brief pauses. Extreme CER and CDV increases still yielded high-quality images. CONCLUSIONS: Real-time echocardiographic acquisition, guidance, and transmission is feasible with the use of MPEG-2 and ATM with broadcast quality seen above 3 Mbps, even with severe network quality degradation. These techniques can be applied to telemedicine and used for planned echocardiography aboard the International Space Station.

NASA Discipline Cardiopulmonary↗

Optical performance of synthetic aperture telescope configurations

The diffraction-limited performances of synthetic aperture configuration arrays of four telescopes, used for coherent imaging or beam transmission, are calculated and compared. The optical performance of phased telescope arrays was found to be more sensitive to rms piston errors than to rms tilt errors. Image degradation due to pupil mapping errors imposes tight tolerances upon the structural integrity of the telescope. One part in 10,000 pupil mapping error limits the field-of-view to approximately 30 arcsec. Field curvature of the independent telescopes provides a fundamental limit to the field-of-view for phased arrays made up of two-mirror telescopes. These field-of-view limitations may profoundly affect target acquisition, tracking, or imaging applications.

Harvey, J. E.↗

The synchronous meteorological satellite /SMS/ system.

The responsibilities of the National Aeronautics and Space Administration (NASA) and Department of Commerce (DOC) pertaining to SMS are described in this paper. A description of the program objectives, payload, and spacecraft subsystems, is included along with an abbreviated description of the SMS ground system. Particular interest is directed towards the visible and infrared spin-scan radiometer (VISSR) as it will be the prime sensor and its performance directly effect the mission objectives. Also, of significant importance is the description of the communications subsystem since transmission and retransmission of image data, data relay, and data collection platform (DCP) transmissions play such a major role in the system. The conclusion is established that the current plans form a workable system for providing timely, high-quality day and night imaging of the earth's weather.

Burr, P. T.↗

Active-Pixel Image Sensors With Programmable Resolution

Active-pixel image sensors with programmable resolution proposed for use in applications in which speed and efficiency of processing of image data enhanced by providing those data at varying resolutions. Such applications include modeling of biological vision, stereoscopic range-finding, recognition of patterns, tracking targets, and progressive transmission of compressed images. In target-tracking application, sensor initially forms low-resolution image from which area of interest identified, then sensor set at high resolution for examination of identified area. Outputs of contiguous pixels combined. Sensor of this type made to act as though it comprised fewer and larger pixels.

Kemeny, Sabrina E.↗

Cable and Line Inspection Mechanism

An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

Terence J Ross↗

Cable and line inspection mechanism

An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

Ross, Terence J.↗

Satellite Hyperspectral Imaging Simulation

Simulation of generic pushbroom satellite hyperspectral sensors have been performed to evaluate the potential performance and validation techniques for satellite systems such as COIS(NEMO), Warfighter-1(OrbView-4) and Hyperion(EO-1). The simulations start with a generation of synthetic scenes from material maps of studied terrain. Scene-reflected radiance is corrected for atmospheric effects and convolved with sensor spectral response using MODTRAN 4 radiance and transmissions calculations. Scene images are further convolved with point spread functions derived from Optical Transfer Functions (OTF's) of the sensor system. Photon noise and etectorr/electronics noise are added to the simulated images, which are also finally quantized to the sensor bit resolution. Studied scenes include bridges and straight roads used for evaluation of sensor spatial resolution, as well as fields of minerals, vegetation and manmade materials used for evaluation of sensor radiometric response and sensitivity. The scenes are simulated with various seasons and weather conditions. Signal-to-noise ratios and expected performance are estimated for typical satellite system specifications and are discussed for all the scenes.

Zanoni, Vicki↗