Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SNIa Cosmology Analysis Results from Simulated LSST Images: From Difference Imaging to Constraints on Dark Energy

Abstract The Vera Rubin Observatory Legacy Survey of Space and Time (LSST) is expected to process ∼10 6 transient detections per night. For precision measurements of cosmological parameters and rates, it is critical to understand the detection efficiency, magnitude limits, artifact contamination levels, and biases in the selection and photometry. Here we rigorously test the LSST Difference Image Analysis (DIA) pipeline using simulated images from the Rubin Observatory LSST Dark Energy Science Collaboration Data Challenge (DC2) simulation for the Wide-Fast-Deep survey area. DC2 is the first large-scale (300 deg 2 ) image simulation of a transient survey that includes realistic cadence, variable observing conditions, and CCD image artifacts. We analyze ∼15 deg 2 of DC2 over a 5 yr time span in which artificial point sources from Type Ia supernova (SNIa) light curves have been overlaid onto the images. The magnitude limits per filter are u = 23.66 mag, g = 24.69 mag, r = 24.06 mag, i = 23.45 mag, z = 22.54 mag, and y = 21.62 mag. The artifact contamination levels are ∼90% of all detections, corresponding to ∼1000 artifacts deg –2 in g band, and falling to 300 deg –2 in y band. The photometry has biases <1% for magnitudes 19.5 < m < 23. Our DIA performance on simulated images is similar to that of the Dark Energy Survey difference-imaging pipeline on real images. We also characterize DC2 image properties to produce catalog-level simulations needed for distance bias corrections. We find good agreement between DC2 data and simulations for distributions of signal-to-noise ratio, redshift, and fitted light-curve properties. Applying a realistic SNIa cosmology analysis for redshifts z < 1, we recover the input cosmology parameters to within statistical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact x-ray sources for mammographic applications: Monte Carlo simulations of image quality

Thomson scattering x-ray sources can provide spectral distributions that are ideally suited for mammography with sufficient fluence rates. In this article, the authors investigate the effects of different spectral distributions on the image quality in simulated images of a breast mammographic phantom containing details of different compositions and thicknesses. They simulated monochromatic, quasimonochromatic, and polychromatic x-ray sources in order to define the energy for maximum figure of merit (signal-difference-to-noise ratio squared/mean glandular dose), the effect of an energy spread, and the effect of the presence of higher-order harmonics. The advantages of these sources with respect to conventional polychromatic sources as a function of phantom and detail thickness were also investigated. The results show that the energy for the figure of merit peak is between 16 and 27.4 keV, depending on the phantom thickness and detail composition and thickness. An energy spread of about 1 keV standard deviation, easily achievable with compact x-ray sources, does not appreciably affect the image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the soil moisture prediction accuracy of a space radar using simulation techniques

Image simulation techniques were employed to generate synthetic aperture radar images of a 17.7 km x 19.3 km test site located east of Lawrence, Kansas. The simulations were performed for a space SAR at an orbital altitude of 600 km, with the following sensor parameters: frequency = 4.75 GHz, polarization = HH, and angle of incidence range = 7 deg to 22 deg from nadir. Three sets of images were produced corresponding to three different spatial resolutions; 20 m x 20 m with 12 looks, 100 m x 100 m with 23 looks, and 1 km x 1 km with 1000 looks. Each set consisted of images for four different soil moisture distributions across the test site. Results indicate that, for the agricultural portion of the test site, the soil moisture in about 90% of the pixels can be predicted with an accuracy of = + or - 20% of field capacity. Among the three spatial resolutions, the 1 km x 1 km resolution gave the best results for most cases, however, for very dry soil conditions, the 100 m x 100 m resolution was slightly superior.

Ulaby, F. T.↗

Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system

Purpose: Undertaking observer studies to compare imaging technology using clinical radiological images is challenging due to patient variability. To achieve a significant result, a large number of patients would be required to compare cancer detection rates for different image detectors and systems. The aim of this work was to create a methodology where only one set of images is collected on one particular imaging system. These images are then converted to appear as if they had been acquired on a different detector and x-ray system. Therefore, the effect of a wide range of digital detectors on cancer detection or diagnosis can be examined without the need for multiple patient exposures. Methods: Three detectors and x-ray systems [Hologic Selenia (ASE), GE Essential (CSI), Carestream CR (CR)] were characterized in terms of signal transfer properties, noise power spectra (NPS), modulation transfer function, and grid properties. The contributions of the three noise sources (electronic, quantum, and structure noise) to the NPS were calculated by fitting a quadratic polynomial at each spatial frequency of the NPS against air kerma. A methodology was developed to degrade the images to have the characteristics of a different (target) imaging system. The simulated images were created by first linearizing the original images such that the pixel values were equivalent to the air kerma incident at the detector. The linearized image was then blurred to match the sharpness characteristics of the target detector. Noise was then added to the blurred image to correct for differences between the detectors and any required change in dose. The electronic, quantum, and structure noise were added appropriate to the air kerma selected for the simulated image and thus ensuring that the noise in the simulated image had the same magnitude and correlation as the target image. A correction was also made for differences in primary grid transmission, scatter, and veiling glare. The method was validated by acquiring images of a CDMAM contrast detail test object (Artinis, The Netherlands) at five different doses for the three systems. The ASE CDMAM images were then converted to appear with the imaging characteristics of target CR and CSI detectors. Results: The measured threshold gold thicknesses of the simulated and target CDMAM images were closely matched at normal dose level and the average differences across the range of detail diameters were -4% and 0% for the CR and CSI systems, respectively. The conversion was successful for images acquired over a wide dose range. The average difference between simulated and target images for a given dose was a maximum of 11%. Conclusions: The validation shows that the image quality of a digital mammography image obtained with a particular system can be degraded, in terms of noise magnitude and color, sharpness, and contrast to account for differences in the detector and antiscatter grid. Potentially, this is a powerful tool for observer studies, as a range of image qualities can be examined by modifying an image set obtained at a single (better) image quality thus removing the patient variability when comparing systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scale effects: HCMM data simulation. Usage of filtering techniques for scaling-up simulations

Image reduction used to simulate increase in altitude of an acquisition platform is equivalent to data smoothing, and can be achieved either by neighborhood averaging or by filtering techniques. The averaging approach is limited for accurate simulation. A filtering method is described which was based on the hypothesis that all changes due to altitude increase can be represented by a point spread function. Determination of the scale function and factor are discussed as well as implementation of the filtering. Filtering can be either in the spatial or frequency domain. In the spatial domain, filtering consists of the convolution of the image with the weights mask, and then of the declination of the points according to the appropriates scale factor. A simulation of an aircraft day image in the infrared channel is examined.

Digennaro, V.↗

Image Collection Simulation Using High-Resolution Atmospheric Modeling

A new method is described for simulating the passive remote sensing image collection of ground targets that includes effects from atmospheric physics and dynamics at fine spatial and temporal scales. The innovation in this research is the process of combining a high-resolution weather model with image collection simulation to attempt to account for heterogeneous and high-resolution atmospheric effects on image products. The atmosphere was modeled on a 3D voxel grid by a Large-Eddy Simulation (LES) driven by forcing data constrained by local ground-based and air-based observations. The spatial scale of the atmospheric model (10–100 m) came closer than conventional weather forecast scales (10–100 km) to approaching the scale of typical commercial multispectral imagery (2 m). This approach was demonstrated through a ground truth experiment conducted at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. In this experiment, calibrated targets (colored spectral tarps) were placed on the ground, and the scene was imaged with WorldView-3 multispectral imagery at a resolution enabling the tarps to be visible in at least 9–12 image pixels. The image collection was simulated with Digital Imaging and Remote Sensing Image Generation (DIRSIG) software, using the 3D atmosphere from the LES model to generate a high-resolution cloud mask. The high-resolution atmospheric model-predicted cloud coverage was usually within 23% of the measured cloud cover. The simulated image products were comparable to the WorldView-3 satellite imagery in terms of the variations of cloud distributions and spectral properties of the ground targets in clear-sky regions, suggesting the potential utility of the proposed modeling framework in improving simulation capabilities, as well as testing and improving the operation of image collection processes.

54 ENVIRONMENTAL SCIENCES↗

Simulating realistic imaging conditions for in situ liquid microscopy

In situ transmission electron microscopy enables the imaging of biological cells, macromolecular protein complexes, nanoparticles, and other systems in a near-native environment. In order to improve interpretation of image contrast features and also predict ideal imaging conditions ahead of time, new virtual electron microscopic techniques are needed. A technique for virtual fluid-stage high-angle annular dark-field scanning transmission electron microscopy with the multislice method is presented that enables the virtual imaging of model fluid-stage systems composed of millions of atoms. The virtual technique is exemplified by simulating images of PbS nanoparticles under different imaging conditions and the results agree with previous experimental findings. General insight is obtained on the influence of the effects of fluid path length, membrane thickness, nanoparticle position, defocus and other microscope parameters on attainable image quality.

Atomistic model↗

Simulation of a tangential soft x-ray imaging system

Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential SXR camera diagnostics are planned for the DIII-D and NSTX tokamaks to elucidate the static edge magnetic structure during the application of 3D perturbations. To support the design of the proposed diagnostics, a synthetic diagnostic model was developed using the CHIANTI database to estimate the SXR emission. The model is shown to be in good agreement with the measurements from an existing tangential SXR camera diagnostic on NSTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discriminating Accretion States via Rotational Symmetry in Simulated Polarimetric Images of M87

In 2017 April, the Event Horizon Telescope observed the shadow of the supermassive black hole at the core of the elliptical galaxy Messier 87. While the original image was constructed from measurements of the total intensity, full polarimetric data were also collected, and linear polarimetric images are expected in the near future. We propose a modal image decomposition of the linear polarization field into basis functions with varying azimuthal dependence of the electric vector position angle. We apply this decomposition to images of ray traced general relativistic magnetohydrodynamics simulations of the Messier 87 accretion disk. Furthermore, for simulated images that are physically consistent with previous observations, the magnitude of the coefficient associated with rotational symmetry, β2, is a useful discriminator between accretion states. We find that at 20 μas resolution, $| {\beta }_{2}| $ is greater than 0.2 only for models of disks with horizon-scale magnetic pressures large enough to disrupt steady accretion. We also find that images with a more radially directed electric vector position angle correspond to models with higher black hole spin. Our analysis demonstrates the utility of the proposed decomposition as a diagnostic framework to improve constraints on theoretical models.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-30: Benchmark Image-Based TCP Calculation for Evaluation of PTV Margins for Lung SBRT Patients

Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVF formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

Beam Characterization at the Neutron Radiography Facility

The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Instrumental and observational requirements for space-based imaging of magnetospheric emissions

Simulated images of extreme ultraviolet (EUV) emissions from energetic outflowing ions have been constructed to study techniques for remotely sensing the dynamic behavior of hot plasmas in the near-Earth environment. These calculations include realistic assumptions about the energetic ion outflow from high latitudes and take into account the effects of cold plasmaspheric and ionospheric ions. The energetic ion outflow is determined from a statistical study based on five years of measurements from the Energetic Ion Composition Spectrometer on Dynamics Explorer 1. The simulated images change significantly with viewing geometry and certain spacecraft locations are clearly favorable for observing emissions from energetic ions. For example, for a near equatorial orbit, viewing locations greater than 9 Earth radii are required to observe outflowing ions above the cold plasmaspheric background. We will discuss other important considerations for magnetospheric imaging including the sensitivity requirements of the detector. In particular, we consider the performance of multi-layer optics for EUV wavelengths.

Robinson, R. M.↗

Simulation of Grazing-Incidence Synchrotron White Beam X-ray Topographic Images of Micropipes in 4H-SiC and Determination of Their Dislocation Senses

Detailed comparison has been drawn between synchrotron white beam X-ray topographic images of micropipes in 4H-SiC, recorded using pyramidal plane reflections in grazing-incidence geometry, and images simulated using the ray-tracing method. The simulations were carried out with and without the influence of surface relaxation effects. The images simulated in the absence of surface relaxation effects appear as white elliptical shaped features, canted to one side or other of the g-vector (depending on the dislocation sense), surrounded by a dark contrast perimeter which thickens at both ends of the major axis and which exhibits two fold symmetry axes parallel to the major and minor axes. On the other hand, on the images simulated taking into account the effects of surface relaxation, the features are again canted to one side or other of the g-vector (depending on the dislocation sense) but do not exhibit the same symmetry in that one of the sides of the oval shape is flattened (along the major axis) and the distribution of intensity around the perimeter no longer possesses the two fold symmetry axes parallel to the major and minor axes. While the details of the distribution of the dark perimeter contrast observed on the recorded images are not so easy to correlate with the simulated distributions, the sense of cant of the roughly elliptical white features on the observed images can be easily correlated with the simulations. Since the sense of cant has the same behavior as a function of dislocation sense for simulations carried out with and without surface relaxation, this provides a high level of confidence that the sense of cant of these features can be readily used to determine the senses of the micropipes.

43 PARTICLE ACCELERATORS↗

A comparison of digitally simulated holographic images with actual holographic images

In making digitally generated holograms the digital computer and its associated plotting equipment degrade the quality of the hologram. It is necessary then to study the computer generated hologram in terms of these degradations. A computer simulated optical processor allows the results to be observed via computer simulated images. This research reports a method for optimizing the computer image reconstruction and compares these images with optically produced holographic images. The versatility of the simulated optical processor is illustrated by several spatial filtering and hologram reconstructions.

Calhoun, M. D.↗

Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in terms of the noise power at the peak height and +/−1.2% in terms of the spatial frequency at the peak height. The magnitudes of the noise measured for 12 different combinations the phantom size, tube current, and reconstruction kernel for the simulated and real low-dose images were very similar, with differences of 0.1 to 4.7%. Thep value for a statistical testing of the difference in the noise magnitude ranged from 0.99 to 0.11, showing that there was no difference statistically between the noise magnitudes of the real and simulated low-dose images using our method. The strength and pattern of the streak noise in an anthropomorphic phantom was also consistent with expectations. Conclusions: A novel reduced-dose CT simulation technique was developed which uses only CT images while not requiring raw sinogram data. Our method can provide realistic simulation results under reduced-dose conditions both in terms of the noise magnitude and the textual appearance. This technique has the potential to promote clinical research for patient dose reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging infrared: Scene simulation, modeling, and real image tracking; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

Various papers on scene simulation, modeling, and real image tracking using IR imaging are presented. Individual topics addressed include: tactical IR scene generator, dynamic FLIR simulation in flight training research, high-speed dynamic scene simulation in UV to IR spectra, development of an IR sensor calibration facility, IR celestial background scene description, transmission measurement of optical components at cryogenic temperatures, diffraction model for a point-source generator, silhouette-based tracking for tactical IR systems, use of knowledge in electrooptical trackers, detection and classification of target formations in IR image sequences, SMPRAD: simplified three-dimensional cloud radiance model, IR target generator, recent advances in testing of thermal imagers, generic IR system models with dynamic image generation, modeling realistic target acquisition using IR sensors in multiple-observer scenarios, and novel concept of scene generation and comprehensive dynamic sensor test.

Triplett, Milton J.↗