Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fine precipitation scenarios of AlZnMg(Cu) alloys revealed by advanced atomic-resolution electron microscopy study Part I: Structure determination of the precipitates in AlZnMg(Cu) alloys

Although they are among the most important precipitation-hardened materials for industry applications, the high-strength AlZnMg(Cu) alloys have thus far not yet been understood adequately about their underlying precipitation scenarios in relation with the properties. This is partly due to the fact that the structures of a number of different precipitates involved in electron microscopy in association with quantitative image simulations have to be employed; a systematic study of these hardening precipitates in different alloys is also necessary. In Part I of the present study, it is shown that there are five types of structurally different precipitates including the equilibrium η-phase precipitate. Using two state-of-the-art atomic-resolution imaging techniques in electron microscopy in association with quantitative image simulations, we have determined and clarified all the unknown precipitate structures. It is demonstrated that atomic-resolution imaging can directly suggest approximate structure models, whereas quantitative image analysis can refine the structure details that are much smaller than the resolution of the microscope. This combination is crucially important for solving the difficult structure problems of the strengthening precipitates in AlZnMg(Cu) alloys. - Highlights: Part I: • We determine and verify all the key precipitate structures in AlMgZn(Cu) alloys. • We employ aberration-corrected scanning transmission electron microscopy (STEM). • We use aberration-corrected high-resolution TEM (HRTEM) for the investigations. • We obtain atomic-resolution images of the precipitates and model their structures. • We refine all precipitate structures with quantitative image simulation analysis. Part II: • The hardening precipitates in AlZnMg alloys shall be classified into two groups. • Two precipitation scenarios coexist in the alloys. • The precipitation behavior of such an alloy depends on the alloy's composition. • Very detailed phase/structure transformations among the precipitates are revealed.

36 MATERIALS SCIENCE↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

PICS: SIMULATIONS OF STRONG GRAVITATIONAL LENSING IN GALAXY CLUSTERS

Gravitational lensing has become one of the most powerful tools available for investigating the “dark side” of the universe. Cosmological strong gravitational lensing, in particular, probes the properties of the dense cores of dark matter halos over decades in mass and offers the opportunity to study the distant universe at flux levels and spatial resolutions otherwise unavailable. Studies of strongly lensed variable sources offer even further scientific opportunities. One of the challenges in realizing the potential of strong lensing is to understand the statistical context of both the individual systems that receive extensive follow-up study, as well as that of the larger samples of strong lenses that are now emerging from survey efforts. Motivated by these challenges, we have developed an image simulation pipeline, Pipeline for Images of Cosmological Strong lensing (PICS), to generate realistic strong gravitational lensing signals from group- and cluster-scale lenses. PICS uses a low-noise and unbiased density estimator based on (resampled) Delaunay Tessellations to calculate the density field; lensed images are produced by ray-tracing images of actual galaxies from deep Hubble Space Telescope observations. Other galaxies, similarly sampled, are added to fill in the light cone. The pipeline further adds cluster member galaxies and foreground stars into the lensed images. The entire image ensemble is then observed using a realistic point-spread function that includes appropriate detector artifacts for bright stars. Noise is further added, including such non-Gaussian elements as noise window-paning from mosaiced observations, residual bad pixels, and cosmic rays. The aim is to produce simulated images that appear identical—to the eye (expert or otherwise)—to real observations in various imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of physical image characteristics and phenomenon of edge enhancement by phase contrast using equipment typical for mammography

A technique called phase contrast mammography (PCM) has only recently been applied in clinical examination. In this application, PCM images are acquired at a 1.75x magnification using an x-ray tube for clinical use, and then reduced to the real size of the object by image processing. The images showed enhanced object edges; reportedly, this enhancement occurred because of the refraction of x rays through a cylindrical object. The authors measured the physical image characteristics of PCM to compare the image characteristics of PCM with those of conventional mammography. More specifically, they measured the object-edge-response characteristics and the noise characteristics in the spatial frequency domain. The results revealed that the edge-response characteristics of PCM outperformed those of conventional mammography. In addition, the characteristics changed with the object-placement conditions and the object shapes. The noise characteristics of PCM were better than those of conventional mammography. Subsequently, to verify why object edges were enhanced in PCM images, the authors simulated image profiles that would be obtained if the x rays were refracted and totally reflected by using not only a cylindrical substance but also a planar substance as the object. So, they confirmed that the object edges in PCM images were enhanced because x rays were refracted irrespective of the object shapes. Further, they found that the edge enhancements depended on the object shapes and positions. It was also proposed that the larger magnification than 1.75 in the commercialized system might be more suitable for PCM. Finally, the authors investigated phase-contrast effects to breast tissues by the simulation and demonstrated that PCM would be helpful in the diagnoses of mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microscopic Understanding of Fischer-Tropsch Synthesis on Ruthenium

Total energy calculations and scanning tunneling microscope (STM) image simulations were conducted in an effort to interpret new experimental images of CO and H adsorbed on the closepacked surface of ruthenium metal. The images are remarkable in suggesting that the adsorbed species are intermixed, plausibly accounting for the superior catalytic activity of this metal in forming hydrocarbons. Insight was gained over the short duration of the project, but a more accurate method of simulating images will be required before contact between theory and experiment points to a final result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Transmission Electron Microscopy on an Absolute Contrast Scale

A fully quantitative approach to high-resolution transmission electron microscopy requires a satisfactory match between image simulations and experiments. While almost perfect agreement between simulations and experiments is routinely achieved on a relative contrast level, a huge mutual discrepancy in the absolute image contrast by a factor of 3 has been frequently reported. It is shown that a major reason for this well-known contrast discrepancy, which is often called Stobbs-factor problem, lies in the neglect of the detector modulation-transfer function in image simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lateral Diffusion Estimation in Fully Depleted Thick CCD Using Flat Field Image Analysis

In thick fully depleted CCDs charge carrier transport from the back window to the gates is accompanied by charge diffusion. Lateral diffusion smooths out density variations of the incoming photon flux by redistributing charges spatially. This creates short range positive correlations in recorded amplitudes. Pixel-to-pixel amplitude variations can also be caused by pixel size and quantum efficiency variations. Pixel size variations result in short range negative correlations. Our study shows that the characteristic diffusion width can be extracted from flat field data. The study was performed on fully depleted, thick CCDs produced in a technology study for the Large Synoptic Survey Telescope (LSST). Data were taken in the laboratory at bias voltages between -5 and -40 V. To increase statistical accuracy, images taken in identical conditions were co-added after base line subtraction and master files were produced. A flat field image simulator was developed for statistical comparison of simulated and measured images. Results on diffusion, pixel response variations, data features, analysis and modeling techniques are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEMImageNet training library and AtomSegNet deep-learning models for high-precision atom segmentation, localization, denoising, and deblurring of atomic-resolution images

Abstract Atom segmentation and localization, noise reduction and deblurring of atomic-resolution scanning transmission electron microscopy (STEM) images with high precision and robustness is a challenging task. Although several conventional algorithms, such has thresholding, edge detection and clustering, can achieve reasonable performance in some predefined sceneries, they tend to fail when interferences from the background are strong and unpredictable. Particularly, for atomic-resolution STEM images, so far there is no well-established algorithm that is robust enough to segment or detect all atomic columns when there is large thickness variation in a recorded image. Herein, we report the development of a training library and a deep learning method that can perform robust and precise atom segmentation, localization, denoising, and super-resolution processing of experimental images. Despite using simulated images as training datasets, the deep-learning model can self-adapt to experimental STEM images and shows outstanding performance in atom detection and localization in challenging contrast conditions and the precision consistently outperforms the state-of-the-art two-dimensional Gaussian fit method. Taking a step further, we have deployed our deep-learning models to a desktop app with a graphical user interface and the app is free and open-source. We have also built a TEM ImageNet project website for easy browsing and downloading of the training data.

25 ENERGY STORAGE↗

Novel usage of deep learning and high-performance computing in long-baseline neutrino oscillation experiments

Mención Internacional en el título de doctorDeep-learning methods are playing a crucial role in numerous scientific and industrialapplications. Over the past two decades, these techniques have helped in the collection,reconstruction, and analysis of large data samples in particle physics experiments. Themain topic of this PhD research is the study of deep-learning techniques in long-baselineneutrino oscillation experiments. Neutrinos are mysterious light elementary particles,and their investigation is essential to shed light on some of the remaining open questionsin physics. The work presented here describes an algorithm based on a convolutionalneural network developed to provide highly accurate and efficient selections of electronneutrino and muon neutrino interactions in the Deep Underground Neutrino Experiment(DUNE). With this algorithm, the electron neutrino (antineutrino) selection efficiencypeaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between2-5 GeV. The selection efficiency for muon neutrino (antineutrino) interactions is foundto have a maximum of 96% (97%) and exceeds 90% (95%) efficiency for reconstructedneutrino energies above 2 GeV. When considering all electron neutrino and antineutrinointeractions as signal (both those appearing from oscillations and those intrinsic tothe beam), a selection purity of 90% is achieved. These event selections are criticalto maximise the sensitivity of the experiment to CP-violating effects, key to furtherunderstand the matter-antimatter asymmetry of the Universe.In high-energy physics experiments, deep learning has also been explored for producingfast simulations and physically-motivated manipulations of simulated images. Some ofthose simulations, such as the light production and detection, are very computationallyexpensive and require novel methods to produce the necessary samples while controllingthe varied underlying physics model parameters. To do so, we invented the model-assistedgenerative adversarial network (MAGAN), first validated on simple generic case studiesand then successfully applied to the DUNE photon-detector simulation.Moreover, we also developed graph neural networks for 3D-voxel classification ofambiguities and optical crosstalk for a different particle physics experiment, most preciselyfor the proposed SuperFGD. This novel 3D-granular plastic-scintillator neutrino detectorwill be used to upgrade the near detector of the T2K neutrino oscillation experiment, and our method reports efficiencies and purities of 94-96% per event in the classificationof particle track voxels.Due to the growth and complexity of deep neural networks, researchers have beeninvestigating techniques to train those networks in a more computationally-efficient way.Many efforts have been made by the community to optimise deep-learning models byparallelising or distributing their training computation across multiple devices. In thisthesis, we study an approach based on data locality for those neural networks that cannotbenefit from scaling their computation due to a significant bottleneck in the data I/O.The research also includes a detailed study on the performance of deep neural networkson hardware accelerator boards.Los métodos de aprendizaje profundo son cada vez más utilizados en numerosas aplicacionescientíficas e industriales hoy en día. Durante las dos últimas décadas, estastécnicas se han empleado en la recolección, reconstrucción y análisis de la gran cantidadde datos generados por experimentos de física de partículas. El tema principal de estatesis doctoral es el uso de estos modelos de aprendizaje profundo en experimentos defísica de neutrinos, en concreto en los experimentos de larga distancia DUNE y T2K. Losneutrinos, partículas fundamentales neutras, de las más ligeras del Universo, pueden serclave para explicar algunas de las cuestiones todavía sin resolver en física fundamental.Entre las diferentes contribuciones que esta tesis ha hecho a su estudio, cabe destacar eldesarrollo de un algoritmo basado en una red de neuronas convolucional para seleccionarcon gran eficiencia y precisión las interacciones de neutrinos electrónicos y muónicos enel Deep Underground Neutrino Experiment (DUNE). La eficiencia de selección obtenidapara neutrinos (antineutrinos) electrónicos alcanza un máximo del 90% (94%) y supera el85% (90%) para neutrinos con energías reconstruidas en el rango 2-5 GeV. La selección deneutrinos (antineutrinos) muónicos tiene una eficiencia máxima del 96% (97%) y excedeel 90% (95%) para neutrinos con energías reconstruidas de más de 2 GeV. Considerandocomo señal todas las interacciones de neutrinos y antineutrinos electrónicos (procedentestanto de oscilaciones como intrínsecos en el haz inicial), se logra una pureza en la seleccióndel 90%. Dichas selecciones de eventos son fundamentales para maximizar la sensibilidaddel experimento a los efectos de violació...

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Verified Lifting to Optimize Legacy Stencil Codes (Final Project Report)

This project investigated new techniques for compiling stencil and stencil-like computations. Stencils computations are commonly found in applications such as image processing, physical simulations, image processing, and machine learning. In recent years, many high-performance domain-specific languages (DSLs) have been proposed to optimize stencil computations. To leverage such DSLs, however, existing codes often need to be rewritten. Such rewriting is manual, labor intensive, and error-prone. To alleviate such issues, this project investigated the application of program synthesis and artificial learning techniques to enable stencil computations to automatically leverage new high-performance DSLs. Rather than constructing syntax driven rules, verified lifting uses program synthesis to search for a target code fragment to compile the given input code into. In addition, it also searches for a proof that validates how the found target code fragment preserves the semantics of the original input. Thus, the target code fragment is guaranteed to be semantically equivalent to the input.

97 MATHEMATICS AND COMPUTING↗

Imaging Enhanced Simulation Validation for Directed Energy Deposition Additive Manufacturing (Final CRADA Report – NFE-22-09107)

Directed Energy Deposition (DED) is a welding-based metal Additive Manufacturing (AM) process that relies on the programmed rastering of an electric arc or laser induced weld pool to construct a component in a layerwise fashion. The induced complex thermal field and uneven thermal contraction depends on the printed geometry and scan pattern, and as such, accumulated residual stresses and distortions are complex and difficult to predict. Several prior works have resulted in tools to combat this issue; ANSYS has developed a thermoplastic simulation package targeting DED AM, and ORNL has developed an in-situ imaging sensor package ‘Stereo Correlated Optical and Pyrometric System’ (SCOPS) that can spatially monitor temperature and full field strain. In this CRADA, these tools are compared in order to validate the results and complimentarily address the weaknesses in each other.

36 MATERIALS SCIENCE↗

Atomic bonding effects in annular dark field scanning transmission electron microscopy. I. Computational predictions

Annular dark field scanning transmission electron microscopy (ADF-STEM) image simulations were performed for zone-axis-oriented light-element single crystals, using a multislice method adapted to include charge redistribution due to chemical bonding. Examination of these image simulations alongside calculations of the propagation of the focused electron probe reveal that the evolution of the probe intensity with thickness exhibits significant sensitivity to interatomic charge transfer, accounting for observed thickness-dependent bonding sensitivity of contrast in all ADF-STEM imaging conditions. Because changes in image contrast relative to conventional neutral atom simulations scale directly with the net interatomic charge transfer, the strongest effects are seen in crystals with highly polar bonding, while no effects are seen for nonpolar bonding. Although the bonding dependence of ADF-STEM image contrast varies with detector geometry, imaging parameters, and material temperature, these simulations predict the bonding effects to be experimentally measureable.

42 ENGINEERING↗

Simulating NMIS Imaging and Fission-Mapping Measurements

The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high resolution electron microscopy

The last two decades have seen dramatic advances in the resolution of the electron microscope brought about by the successful correction of lens aberrations that previously limited resolution for most of its history. Here we briefly review these advances, the achievement of sub-Ångstrom resolution and the ability to identify individual atoms, their bonding configurations and even their dynamics and diffusion pathways. We then present a review of the basic physics of electron scattering, lens aberrations and their correction, and an approximate imaging theory for thin crystals which provides physical insight into the various different imaging modes. Then we proceed to describe a more exact imaging theory starting from Yoshioka’s formulation and covering full image simulation methods using Bloch waves, the multislice formulation and the frozen phonon/quantum excitation of phonons models. Delocalization of inelastic scattering has become an important limiting factor at atomic resolution. We therefore discuss this issue extensively, showing how the full-width-half-maximum is the appropriate measure for predicting image contrast, but the diameter containing 50% of the excitation is an important measure of the range of the interaction. These two measures can differ by a factor of 5, are not a simple function of binding energy, and full image simulations are required to match to experiment. The Z-dependence of annular dark field images is also discussed extensively, both for single atoms and for crystals, and we show that temporal incoherence must be included accurately if atomic species are to be identified through matching experimental intensities to simulations. Finally we mention a few promising directions for future investigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system

Purpose: The scanning beam digital x-ray system (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis in multiple planes. This system could be used for image guidance during lung nodule biopsy. However, the reconstructed images suffer from strong out-of-plane artifact due to the small tomographic angle of the system. Methods: The authors propose an out-of-plane artifact subtraction tomosynthesis (OPAST) algorithm that utilizes a prior CT volume to augment the run-time image processing. A blur-and-add (BAA) analytical model, derived from the project-to-backproject physical model, permits the generation of tomosynthesis images that are a good approximation to the shift-and-add (SAA) reconstructed image. A computationally practical algorithm is proposed to simulate images and out-of-plane artifacts from patient-specific prior CT volumes using the BAA model. A 3D image registration algorithm to align the simulated and reconstructed images is described. The accuracy of the BAA analytical model and the OPAST algorithm was evaluated using three lung cancer patients’ CT data. The OPAST and image registration algorithms were also tested with added nonrigid respiratory motions. Results: Image similarity measurements, including the correlation coefficient, mean squared error, and structural similarity index, indicated that the BAA model is very accurate in simulating the SAA images from the prior CT for the SBDX system. The shift-variant effect of the BAA model can be ignored when the shifts between SBDX images and CT volumes are within ±10 mm in the x and y directions. The nodule visibility and depth resolution are improved by subtracting simulated artifacts from the reconstructions. The image registration and OPAST are robust in the presence of added respiratory motions. The dominant artifacts in the subtraction images are caused by the mismatches between the real object and the prior CT volume. Conclusions: Their proposed prior CT-augmented OPAST reconstruction algorithm improves lung nodule visibility and depth resolution for the SBDX system.

60 APPLIED LIFE SCIENCES↗