Search NASA⌕ Search

SEARCH · Search NASA

Results for “In-Core Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Assessment of sensor technologies for advanced reactors - 250

This paper provides an assessment of sensor technologies and a determination of measurement needs for advanced reactors (AdvRx). It is a summary of a study performed to provide the technical basis for identifying and prioritizing research targets within the instrumentation and control (I and C) Technology Area under the Department of Energy's (DoE's) Advanced Reactor Technology (ART) program. The study covered two broad reactor technology categories: High Temperature Reactors and Fast Reactors. The scope of 'High temperature reactors' included Gen IV reactors whose coolant exit temperatures exceed about {approx}650 deg. C and are moderated (as opposed to fast reactors). To bound the scope for fast reactors, this report reviewed relevant operating experience from US-operated Sodium Fast Reactor (SFR) and relevant test experience from the Fast Flux Test Facility (FFTF). For high temperature reactors the study showed that in many cases instrumentation have performed reasonably well in research and demonstration reactors. However, even in cases where the technology is 'mature' (such as thermocouples), HTGRs can benefit from improved technologies. Current HTGR instrumentation is generally based on decades-old technology and adapting newer technologies could provide significant advantages. For sodium fast reactors, the study found that several key research needs arise around (1) radiation-tolerant sensor design for in-vessel or in-core applications, where possible non-invasive sensing approaches for key parameters that minimize the need to deploy sensors in-vessel, (2) approaches to exfiltrating data from in-vessel sensors while minimizing penetrations, (3) calibration of sensors in-situ, and (4) optimizing sensor placements to maximize the information content while minimizing the number of sensors needed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In-core flux sensor evaluations at the ATR critical facility

Flux detector evaluations were completed as part of a joint Idaho State University (ISU) / Idaho National Laboratory (INL) / French Atomic Energy commission (CEA) ATR National Scientific User Facility (ATR NSUF) project to compare the accuracy, response time, and long duration performance of several flux detectors. Special fixturing developed by INL allows real-time flux detectors to be inserted into various ATRC core positions and perform lobe power measurements, axial flux profile measurements, and detector cross-calibrations. Detectors initially evaluated in this program include the French Atomic Energy Commission (CEA)-developed miniature fission chambers; specialized self-powered neutron detectors (SPNDs) developed by the Argentinean National Energy Commission (CNEA); specially developed commercial SPNDs from Argonne National Laboratory. As shown in this article, data obtained from this program provides important insights related to flux detector accuracy and resolution for subsequent ATR and CEA experiments and flux data required for bench-marking models in the ATR V&V Upgrade Initiative.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PREDICTIVE MODELING OF ACOUSTIC SIGNALS FROM THERMOACOUSTIC POWER SENSORS (TAPS)

Thermoacoustic Power Sensor (TAPS) technology offers the potential for self-powered, wireless measurement of nuclear reactor core operating conditions. TAPS are based on thermoacoustic engines, which harness thermal energy from fission reactions to generate acoustic waves by virtue of gas motion through a porous stack of thermally nonconductive material. TAPS can be placed in the core, where they generate acoustic waves whose frequency and amplitude are proportional to the local temperature and radiation flux, respectively. TAPS acoustic signals are not measured directly at the TAPS; rather, they propagate wirelessly from an individual TAPS through the reactor, and ultimately to a low-power receiver network on the vessel’s exterior. In order to rely on TAPS as primary instrumentation, reactor-specific models which account for geometric/acoustic complexities in the signal propagation environment must be used to predict the amplitude and frequency of TAPS signals at receiver locations. The reactor state may then be derived by comparing receiver signals to the reference levels established by predictive modeling. In this paper, we develop and experimentally benchmark a methodology for predictive modeling of the signals generated by a TAPS system, with the intent of subsequently extending these efforts to modeling of TAPS in a liquid sodium environmen

thermoacoustics, wireless in-core radiation detect↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. For this reason, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). The goal of this research is to characterize magnetostrictive and piezoelectric transducer survivability during irradiation, enabling the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). As such, this test will be an instrumented lead test and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers.

harsh-environment sensors↗

A potential emerging issue concerning repair welding of out-of-core PWR components involving tritium exposure and 3 He retention

This paper identifies a potential but previously unrecognized risk of helium-induced embrittlement and cracking during repair welding of out-of-core pressurized water reactor (PWR) components exposed to tritium-contaminated coolant. While previous weldability concerns centered on 4 He accumulation in neutron-irradiated alloys located within the in-core or near-core regions, new measurements show that 3 He generated by tritium decay can accumulate in out-of-core components. Because hydrogen isotopes readily diffuse to grain boundaries and become trapped there, significant 3 He generation at grain boundaries may lead to cracking during weld repairs. Initial data from far-below-core PWR flux thimble tubes confirm the presence of 3 He levels above known cracking thresholds for repair welds. In conclusion, these findings indicate that out-of-core regions should be considered when defining safe weld repair windows in reactors operating for 60–100 years.

Extended PWR lifetimes↗

A Data-driven approach to Core Power distribution reconstruction in a Nuclear Reactor

This report presents the initial development of a data-driven approach for reconstructing the core power distribution in a nuclear reactor (power shape synthesis) using ex-core sensors. Traditional techniques rely on deploying a large number of detectors throughout the reactor core. However, this approach is not feasible for innovative reactor concepts like Advanced Reactors and Microreactors. First, the tight lattice pitch, designed to maximize power density, limits the space available for sensors. Secondly, the harsh operating conditions are not compatible with commercially available detectors. The method proposed in this work integrates high-fidelity modeling with data-driven techniques to accurately reconstruct power distribution across various reactor types, thereby reducing the reliance on in-core sensors. Purdue University Reactor One (PUR-1) was selected as the test case. The CAD model representing the latest configuration of the PUR-1 core was imported into the OpenMC simulation framework, and the model was built. Additionally, the previously developed MCNP6 model was updated. The two models were assessed against the data collected during an experimental campaign conducted in July 2024. Thirty gold foils were placed in three Irradiation Assemblies in PUR-1 core. Using the measured activity of the irradiated foils, the neutron flux at different core locations was estimated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 . The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric transducer and two magnetostrictive transducers have demonstrated reliable operation under irradiation. The irradiation is ongoing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN ADVANCED ULTRASONIC WAVEGUIDE CONCEPT FOR SPATIALLY DISTRIBUTED MONITORING OF IN-CORE TEMPERATURES

Critical process temperatures in a reactor core are conventionally measured using either resistance temperature detectors or thermocouples, both of which exhibit performance degradation at the temperature ranges of advanced reactors. Ultrasonic thermometry (UT) has long been offered as an alternative, potentially robust measurement option. With emerging interest in advanced reactors and a trend toward extracting more information from the core and the connected heat transport systems, UT is again considered a potential measurement method. Conventionally, acoustic waveguides employ simple notches at a measurement point to reflect incident waves. However, this approach results in rapid attenuation of acoustic energy as the wave crosses notches, as some fraction of its energy is reflected while the rest is transmitted. This research addresses this fundamental issue. This paper reports on the development of an ultrasonic waveguide concept that exploits the constructive interference of wave dynamics. The waveguide uses acoustic filters at the measurement zones that exhibit very high transmittance or reflectance as a function of interrogation frequency. Preliminary results will be discussed.

Cetiner, Nesrin↗

Calculation of neutron and gamma fluxes in support to the interpretation of measuring devices irradiated in the core periphery of the OSIRIS Material Testing Reactor

Technological irradiations carried out in material testing reactors (MTRs) are used to study the behavior of materials under irradiation conditions required by different types of nuclear power plants (NPPs). For MTRs, specific instrumentation is required for the experiment monitoring and for the characterization of irradiation conditions, in particular the flux of neutrons and photons. To measure neutron and photon flux in experimental locations, different sensors can be used, such as SPNDs (self-powered neutron detectors), SPGDs (self-powered gamma detectors) and ionization chambers. These sensors involve interactions producing ultimately a measurable electric current. Various sensors have been recently tested in the core periphery of the OSIRIS reactor (located at the CEA-Saclay center) in order to qualify their responses to the neutron and the photon flux. One of the key input data for this qualification is to have a relevant evaluation of neutron and gamma fluxes at the irradiation location. The objective of this work is to evaluate the neutron and the gamma flux in the core periphery of the OSIRIS reactor. With this intention, specific neutron-photonic three-dimensional calculations have been performed and are mainly based on the TRIPOLI-4{sup R} three-dimensional continuous-energy Monte Carlo code, developed by CEA (Saclay Center) and extensively validated against reactor dosimetry benchmarks. In the case of the OSIRIS reactor, TRIPOLI-4{sup R} code has been validated against experimental results based on neutron flux and nuclear heating measurements performed in ex-core and in-core experiments. In this work, simultaneous contribution of neutrons and gamma photons in the core periphery is considered using neutron-photon coupled transport calculations. Contributions of prompt and decay photons have been taken into account for the gamma flux calculation. Specific depletion codes are used upstream to provide the decay-gamma sources required by TRIPOLI-4 calculations. In this paper, the neutron-photonic calculation scheme used for the neutron-gamma flux evaluation in the OSIRIS core periphery will be first detailed. Then, a comparison of calculated and measured values of neutron and gamma fluxes will be introduced. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Core Status of Fukushima Daiichi Nuclear Power Plant

There were some events and phenomena that occurred which have been deemed specific to the Fukushima Daiichi NPP. The primary issues were as follows: - Direct steam leakage from the reactor pressure vessels (RPVs) to the dry-wells through the gaskets of the safety relief valves and/or due to creep damage of the main steam line, and damage of the in-core monitor guide tubes due to buckling. - Direct corium leakage from the RPVs to the pedestal floors through the melt portions of the in-core monitor housings. - Alternative water injection by the fire trucks with large amount of leakages through the branch lines. - Partial load operation of the Reactor Core Isolation Cooling system and the High Pressure Coolant Injection system. - Gas leakage from the primary containment vessels to the reactor buildings due to over pressure than the design maximum value. - Thermal stratification in the suppression pool resulting in incomplete steam condensation in the pool. The accident progressions were analyzed with the newly developed physical models for the above issues. And also considering the qualitatively estimated core status based on the plant parameters measured after the accident, the current core status was assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Criticality Benchmarking of the Oregon State TRIGA Reactor Using the MCNP Burn Option

Neutronic analyses of the Oregon State TRIGA Reactor (OSTR) have historically been performed using a thoroughly validated MCNP model. This model was originally created in 1997 in support of boron neutron capture therapy (BNCT) research, when the core still utilized highly-enriched uranium (HEU) fuel. The OSTR core was converted to low-enriched uranium (LEU) in the fall of 2008. To more accurately represent the converted state of the core, the MCNP model was modified to incorporate fuel material information from the fuel manufacturer (AREVA). In previous versions of the model, the fuel elements were assumed to have a uniform isotopic composition. Chemical analysis from AREVA provided far more resolved material information, allowing for increased fidelity in the representation of the fuel. The model was also updated to ENDF/B-VII.1 cross section libraries as the previous model utilized ENDF/B-VI. The primary impetus for the update of the MCNP model was the desire to have a more accurate assessment of criticality conditions of the OSTR. The OSTR utilizes three core configurations which are defined by the contents of the B1 grid position. If fuel resides in B1, this is designated as the 'normal' core. Otherwise, there are two aluminum in-core irradiation tubes (ICITs) that can be placed in B1. There is an unlined tube, designated simply as the ICIT, and there is a cadmium-lined tube, designated as the CLICIT. Table 1 contains a summary of the results of a series of MCNP criticality calculations which used the original 'fresh fuel' isotopics from the fall of 2008 in conjunction with critical rod height data from December 2013. Calculations were performed at 15 W, which is where the daily core excess measurements are taken, and at 1 MW, which is the current full-power level at the OSTR. The k-effective values indicate that the fresh fuel material cards are highly inaccurate and over-predict the criticality by at least $1.20 in every core configuration (based on a β{sub eff} value of 0.0075), thus it was desired to perform a depletion calculation to obtain more accurate fuel information. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resonance Self-shielding Impact on Neutron Spectrum Determination for Missouri S and T Reactor

Neutron Activation Analysis is a useful technique for characterizing the neutron flux at nuclear facilities. It involves irradiating samples to produce unstable isotopes, which enables qualitative and quantitative analyses of unknown samples. In the process, samples are bombarded with neutrons; new elements then become radioactive isotopes due to absorption of neutrons. These emit different amounts of gamma energy during the decay process, and gamma rays are counted using HPGe. Each reaction product has a known half-life and cross-section, and by measuring the amount of gamma radiation energy emitted from a radioactive isotope, it is possible to identify the isotope and activity. However, the neutron spectrum is not precise or representative of the actual neutron environment because of the self-shielding effect. This occurs with large samples that have large cross-sections or thicknesses in the resonance range of the neutron flux spectrum. Several methods have been used to mitigate this problem, such as thinning or diluting alloys samples, calculating the self-shielding factor for each material, and generating a corrected library for the unfolding procedure code. The Missouri University of Science and Technology Reactor (MSTR) is a pool-type research reactor that operates up to 200 kW. It uses light-water for both moderation and natural convective heat removal. The reactor core consists of 15 fuel elements positioned in a 9 x 6 aluminum grid plate, with four elements used for reactor power control. The fuel element is 19.75% low enriched uranium in 18 curved fuel plates. The reactor has seen various configurations starting with configuration designation 101W and subsequent reconfiguration increases the numeric designation by 1. The current configuration, 120W, was implemented in 2010. The new configuration provides more in-core locations for activation experiments and uses more fuel elements than previous ones. One of the irradiation locations in the MSTR core is the source holder. It is desired to improve the documentation of neutronic characteristics of the MSTR which are cardinal to experiments supported by the facility. One of these characteristics is the neutron spectrum at various locations in the reactor. Successful efforts yielded the neutron spectrum at a known location through the unfolding of the activity of irradiated foils. The purpose of this current study is to investigate the impact of resonance self-shielding of some of the activated foils on the determined spectrum.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Analysis of Damage to MPFDs Caused by Reactor Pulses

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. The TREAT reactor is designed to produce large, transient fluxes that replicate the effects of a wide variety of accident conditions on an irradiated fuel sample. Peak powers generated during short pulses approach 20 GW with a neutron flux of approximately 10{sup 17} n cm{sup -2} s{sup -1}. As part of the restart effort, new vehicle designs are being explored for sample irradiation, including the Static Environment Rodlet Transient Test Apparatus (SERTTA) and variants. As part of the SERTTA designs, micro-pocket fission detectors (MPFDs) are being explored for localized flux measurements before, during, and after transient operations. These detectors are also being considered as part of future, core-wide instrumentation for the TREAT reactor. However, the high fluxes associated with the pulses in the TREAT core present certain thermodynamic concerns given their intensity and the amount of energy they will release within the MPFDs within such a short amount of time. Assuming each fission that occurs in a MPFD results in a fission fragment depositing 85 MeV of energy in the substrate on average and each MPFD has 0.5 μg of natural uranium deposited on it, a 100 ms long pulse in the TREAT reactor at 1017 n cm{sup -2} s{sup -1} flux will produce approximately 4.6 x 10{sup 6} fissions in an MPFD. This pulse deposits 6.3 x 10{sup -5} J in the substrate over a 100 ms duration. That amount of energy is sufficient to melt roughly 33% of the Pt under the UO{sub 2} deposition or a circular spot with a diameter of approximately 860 μm. Of course, the above estimate makes a number of simplifying assumptions and ignores heat transfer, but does serve to illustrate the point that this rapid heating effect could be detrimental to the integrity and life of these in-core MPFDs. To study how these layers are affected by large transient neutron fluxes, five samples were prepared, pre-analyzed, and then subjected to a pulse in the central thimble of the Kansas State University TRIGA Mark II reactor to a peak power of 1.58 GW. After being allowed to decay to safer radiation levels, the sample substrates and coatings were inspected using scanning electron microscopy (SEM) to identify any changes to their surface morphology. Indeed, certain changes were found and are discussed in greater detail in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MITR RELAP5 Model Validations at Steady States and Transients

The Massachusetts Institute of Technology Reactor (MITR-II) is a 6 MW university research reactor designed primarily for experiments using neuron beams and in-core irradiation facilities, and education. The objective of this study is to validate the MITR RELAP5 model, which includes the reactor core, primary coolant loop, secondary coolant loop and heat exchanger models. Two sets of operational data were collected for validation. Steady-state data for 1 MW, 3 MW, 5.5 MW was obtained in the first test. The continuous startup transient data and the cooling tower outlet coolant temperature reduction obtained during the second test. The five steady-state conditions and two transient conditions were calculated by the RELAP5. The reactor power and cooling tower outlet temperature were used as boundary conditions while the reactor core inlet temperature and outlet temperature were calculated. A comparison was made between the modeling results and the temperature measurements. The results show that the MITR RELAP5 modeling results are in good agreement with measurement data for both steady-state and transient conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗